CyAn : 11 Parameter Desktop Flow Cytometer



Similar documents
Introduction to flow cytometry

These particles have something in common

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer

Introduction to Flow Cytometry

Cell Cycle Tutorial. Contents

Introduction to Flow Cytometry

FlowSight. Flow cytometry with vision

1. Instrument Layout pg Summit Overview pg Data Storage and Data Files pgs Saving Data pg Start Up pg 8

Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement

BD FACSComp Software Tutorial

COMPENSATION MIT Flow Cytometry Core Facility

BD FACSDiva TUTORIAL TSRI FLOW CYTOMETRY CORE FACILITY

INSIDE THE BLACK BOX

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

Introduction to Flow Cytometry -- BD LSR II. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size

Boundary-breaking acoustic focusing cytometry

Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking

APPLICATION INFORMATION

FACS Laboratory. BD LSRs Operator Training. Training Guide.

Instructions for Use. CyAn ADP. High-speed Analyzer. Summit G June Beckman Coulter, Inc N. Harbor Blvd. Fullerton, CA 92835

CyFlow Space Your flexible flow cytometer

CyFlow SL. Microbiology. Detection and Analysis of Microorganisms and Small Particles

Instrument Characterization and Performance Tracking for Digital Flow Cytometers

Analyzer Experiment setup guide for LSRII and Canto s

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

Three Rules for Compensation Controls

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy.

Immunophenotyping peripheral blood cells

powerful. Intuitive. Customizable. The new star of benchtop flow cytometry

Science is hard. Flow cytometry should be easy.

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

EDF Extended Depth of Field

Spherotech, Inc Irma Lee Circle, Unit 101, Lake Forest, Illinois

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping

Hoechst HSC Staining and Stem Cell Purification Protocol (see Goodell, M., et al. (1996) J Exp Med 183, )

Principles of Flowcytometry

Flow cytometry basics fluidics, optics, electronics...

Standard Operating Procedure

LSR II Users Guide Stanford Shared FACS Facility 06/10/13

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and

Introduction to Flow Cytometry:

FLOW CYTOMETRY: PRINCIPLES AND APPLICATIONS. By: Douaa Moh. Sayed

Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose

Below is a list of things you should be aware of before you schedule your sort.

Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer

Immunophenotyping Flow Cytometry Tutorial. Contents. Experimental Requirements...1. Data Storage...2. Voltage Adjustments...3. Compensation...

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE


Easy to use. Compact. Flexible. Sorting Chip

Technical Bulletin. Standardizing Application Setup Across Multiple Flow Cytometers Using BD FACSDiva Version 6 Software. Abstract

UCHC Guide to CellQuest Pro. FACS Calibur instruments

Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis

HIGH PERFORMANCE FLOW CYTOMETER FOR EVERYONE

MACSQuantify Software guide. Basics of flow cytometric analysis and software guide. Version 1 EN Original instructions

Flow Cytometry. flow cytometer DNA apoptosis ph

Uses of Flow Cytometry

Technical Bulletin. An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee

Supplementary Material. Free-radical production after post-thaw incubation of ram spermatozoa is related to decreased in vivo fertility

Partec PAS. Your Flow Cytometer.

CyAn ADP with Summit Software User Guide

Flow Cytometry A Basic Overview

FACSCanto RUO Special Order QUICK REFERENCE GUIDE

BD FACSCanto Flow Cytometer. Efficient Easy Powerful

UCHC Guide to FACS DiVa. LSR II instruments

GETTING STARTED. 6. Click the New Specimen icon.

Flow Data Analysis. Qianjun Zhang Application Scientist, Tree Star Inc. Oregon, USA FLOWJO CYTOMETRY DATA ANALYSIS SOFTWARE

A Basic Guide. Institute of Medical Biology, University of Southern Denmark. Ungated Gate 1 (= R1) Gate 4 (=R4) Gate3 (=R3) Gate 2 (= R2) R3 R4

Lab 2. Isolation of mononuclear cells from peripheral blood and separation into subpopulations

Standardization, Calibration and Quality Control

Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility

Flow Cytometry 101. Jodi Moore, PhD Jan 2012 Goldenson 113

Compensation Controls Data Visualization Panel Development Gating Quantum Dots

How to operate the BD FACSCanto flow cytometer

Compensation in Flow Cytometry

Fluorescence Compensation. Jennifer Wilshire, PhD

Islet Viability Assessment by Single Cell Flow Cytometry

Small-Particle Analysis

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

BD LSR II and FACSDiVa Software. Dr. Jens Fleischer, Basel Dr. Norbert Leclere,, Berlin

EdU Flow Cytometry Kit. User Manual

Setting up and calibration of a flow cytometer for multicolor immunophenotyping

flow cytometry reinvented

Cytometry without limits

BD CellQuest Pro Software Analysis Tutorial

BD FACSVerse. Simply brilliant

FRET Basics and Applications an EAMNET teaching module

International Beryllium Conference, Montreal, Canada March 10, 2005

Bacterial Detection and Live/Dead Discrimination by Flow Cytometry

Granulocytes vs. Agranulocytes

BD FC Beads 8-Color Kit for BD OneFlow Assays

Application Note 10. Measurement of Cell Recovery. After Sorting with a Catcher-Tube-Based. Cell Sorter. Introduction

Flow Cytometry Protocols

Institut für Experimentelle Immunologie und Bildgebung

--Verity Software House, ModFit for Proliferation offers online tutorials

Transcription:

CyAn : 11 Parameter Desktop Flow Cytometer

Cyan ADP 3 excitation lines 488nm, 635nm, and UV or violet 11 simultaneous parameters FSC, SSC, and 7-9 colors with simultaneous width, peak, area, and log on each High Throughput >50,000 events/sec analysis rate Desktop footprint

Cyan ADP Optical layout

Spatially separated laser Lines reduced crosstalk Cyan ADP

Cyan ADP Which fluorochromes can we detect? 488nm 2-3 lasers: 488nm, 635nm and 405nm 635nm 405nm

Cyan ADP Easy to Change Filters & Dichroics

Cyan ADP - Control Cyan ADP controlled by the Summit Software 1. Fluidics 2. Lasers 3. PMTs 4. Trigger and Threshold

Cyan ADP - Control 1.Fluidics Sheath management system (SMS) 20-24hours sample run time Event Rate- Fully modifiable Backflush Debubble Both software control panel and LEDs on the SMS provide fluid level status information to the user Automated fluidics startup/shutdown and clean/rinse

Cyan ADP - Control Summit Software 2. Lasers Instrument control panel Turn Lasers On and Off Control Laser Shutters

Cyan ADP - Control 3, 4. PMTs, trigger and threshold CyAn Parameter Panel Edit the Parameter Names Updated in real-time Change the Voltage on the PMT s Change the Lin, Log, Peak or Integral Setting Change the Gain on Linear Settings Change the Threshold

Cyan ADP - Software Summit Software Windows platform Powerful data analysis both during and after acquisition Full Control of All Instrument Parameters Ability to Save an Application Protocol Layout Compensation Settings Parameter Names Voltages, Gains, Lin/Log Free Summit Offline

Cyan ADP - Software Boolean gates Overlays Subtraction Normalisation Multiple Sample Analysis Zoom Gate limits and Filters

Cyan ADP - Software Drag and Drop 9 x 9 Compensation Matrix Compensation pre- and postacquisition Help function Smoothing/Contours Colours/Fonts Exportable Read/Write all FCS formats

Cyan ADP - Applications Multicolour immunophenotyping Rare event detection High speed immunophenotyping Small Particle analysis Signal Transduction DNA/cell cycle analysis

Cyan ADP Multicolour immunophenotyping 7-Color Staining Panel Monoclonal Antibodies: CD45 FITC Pan Leukocytes CD56 PE NK marker CD3 PE-TR T cells CD14 PE-Cy5 Monocytes CD4 PE-Cy7 T helper CD19 APC B cells CD8 APC-Cy7 T Suppressor/Cytotoxic Preparation: The cell preparation was carried out on human blood, using the Dako Uti-Lyse kit.

Cyan ADP - Mutlicolour immunophenotyping 256 SSC vs. FSC SSC vs. CD3 PE-TR 256 Eosinophils 192 192 SSC 128 Granulocytes Monocytes Lymphocytes SSC 128 T - Lymphocytes 64 64 R6 0 0 64 128 192 256 FSC Debris Leukocyte Populations 0 10 0 10 1 10 2 10 3 10 4 CD 3 PE-TR Comp

Cyan ADP Multicolour immunophenotyping CD14 PE-Cy5 vs. CD45 FITC 10 4 SSC vs. CD45 FITC 256 Monocytes R2 10 3 192 CD14 PE-Cy5 Comp Neutrophils 10 2 R9 R3 R11 Eosinophils Lymphocytes SSC 128 Lymphocytes 10 1 64 R4 R1 10 0 10 0 10 1 10 2 10 3 10 4 CD 45 FITC Comp 0 10 0 10 1 10 2 10 3 10 4 CD 45 FITC Comp Basophils Leukocyte Populations

Cyan ADP Multicolour immunophenotyping CD19 Positive Lymphocytes APC positive (FL8) Excitation: 635 nm B Cells Detection: 665/20 BP In this donor, 13.0% of the lymphocytes are B cells. B and T cell populations CD 19 APC Comp 10 4 10 3 10 2 CD19 APC vs. CD3 PE-TR R12 R13 Gated on Lymphocytes CD 19 APC Comp Natural Killer cells CD19 APC vs. CD56 PE 10 4 R11 R12 10 3 10 2 Gated on Lymphocytes NK cells R14 R15 R13 R14 10 1 10 1 10 0 100 101 102 103 104 CD 3 PE-TR Comp T Cells 10 0 100 101 102 103 104 CD 56 PE Comp CD3 Positive Lymphocytes PE-TR positive (FL3) Excitation: 488 nm Detection: 619/20 BP In this donor, 74.1% of the lymphocytes are T cells. CD56 Positive Lymphocytes PE positive (FL2) Excitation: 488 nm Detection: 575/25 LP In this donor, 0.36% of the lymphocytes are NK.

Cyan ADP Rare event detection Rare event detection High Speed detection of Antigen (EBV) specific tetramers from whole blood (less than 0.1% total blood cells), with very low background CONTROL EBV+

Cyan ADP High speed analysis High Speed Immunophenotyping 1 x 10 6 cells/ml 500,000 events 8 min 18 sec 5 x 10 6 cells/ml 500,000 events 1 min 38 sec 50 x 10 6 cells/ml 500,000 events 10 seconds

Cyan ADP Small particle analysis Small particle analysis 10 4 10 3 Bacteria spores, 0.8 µm Fungus, 5 µm Advantage of distinguishing different species of bacteria by light scatter One customer is even looking at levels of bacteria & yeast in wine [2469] 125.0% (SSC) 10 2 10 1 Bacteria spores, 0.5 µm Bacteria, 1-2 µm 10 0 10 0 10 1 10 2 10 3 10 4 [2165] 106.3% (FSC)

Cyan ADP Signal transduction CFP/YFP FRET Transfected cells CFP only Transfected cells YFP only Transfected cells FRET FSC v SSC gate

Cyan ADP - DNA cell viability and cycle analysis DNA Dyes 488 Excited Propidium Iodide (PI) 7-AAD UV Excited DAPI Hoechst 635 Excited DRAQ5 CyAn provides great flexibility as to which laser is used for your DNA measurement