Operating Instructions



Similar documents
Operating Instructions

Operating Instructions

Table of Contents. Inductive Loop Vehicle Detector Applications

The Basics of Loop Vehicle Detection

Operating Instructions. UL325 Compliant Non-monitored

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

FACTORY AUTOMATION. Manual Laying loops for Loop detector LC10-1 and LC10-2

Single Channel Loop Detector

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

MANAGEMENT SOLUTION (P.A.M.S.)

Water Leak Detection System

PART 1 - INTRODUCTION...

TS93 EMR T/PT/TDE. Surface applied door closer

SMART SENSOR COLLECTION

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

Guideline Laser Series

PERF10 Rubidium Atomic Clock


MCR1900 Media Converter 19-Slot Chassis

OPL BASIC. Dosing System for Professional Laundry machines. Contents

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

AC-115 Compact Networked Single Door Controller. Installation and User Manual

USER MANUAL V5.0 ST100

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810

Product Specification instalert Rapid Messenger Variable Message Sign

INTREPID Perimeter Intrusion Detection System

Perimeter Security System

SDX Submersible Depth Transmitter User Manual

Manual Ranging MultiMeter

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Electric Heat Tracing INSTALLATION PROCEDURES

How To Read A Pipe From A Sensor

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

Technical Overview Add-on Sensors - Smoke Alarm. Get yours direct at:

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

ACL 395 Resistivity Meter

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Troubleshooting accelerometer installations

APOLLO Gate Operators, Inc.

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

HERZ-Thermal Actuators

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

NEW SERVICE INSTALLATION STEPS. Common Slow Downs. Other Necessary Steps

Contents. Document information

INSTALLATION INSTRUCTIONS

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

12 Volt 30 Amp Digital Solar Charge Controller

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

RY2 miniature industrial relays

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

AC-DC Converter Application Guidelines

i ChatterBox! Motorcycle Security

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

1993 ACCESSORIES & EQUIPMENT Volkswagen Instrument Panels. Volkswagen; EuroVan, Passat

Manual for Fire Suppression & Methane Detection System

TECH SUPPORT NORTH SEMORAN BLVD ORLANDO FL32807

Shunt lock function 3066

Home Security Alarm System

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

BroadBand PowerShield. User Manual

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

YSmart Technology Co.,Ltd

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

TrueAlarm Fire Alarm Systems

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

Series 510 Submersible Level Transmitters

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Digi-Motor Installation Guide

GTR-128/GTR-129 Motorcycle/ Vehicle Tracker Quick Start Guide

LOXONE 12 Channel Amplifier

LocoNet, the Digitrax Difference

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

TAC1 Telephone Entry System Installation and Programming Manual

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

ADM1TE 5/30A DIN rail single phase two wire energy meter

PagePac PAGEPAL V

INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200

Model 201 Wiegand Touchpad Reader Installation Guide

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

Part Number:

Transcription:

CS101 CarSense Vehicle Motion Detector Operating Instructions

CAUTIONS AND WARNINGS Never use the CS101 as a safety reversing or presence detection system. The CS101 requires that a vehicle be moving for detection. This product is an accessory or part of a system. Always read and follow the manufacturer s instructions of the equipment before connecting this product. Comply with all applicable codes and safety regulations. Failure to do so may result in damage, injury or death. DO NOT INSTALL PROBE IN HOT ASPHALT PROVIDE AN EARTH GROUND CONNECTION USING GROUND ROD PER INSTALLATION INSTRUCTIONS DO NOT EXCEED POWER SUPPLY VOLTAGE RATING 41VDC or 29VAC ALLOW 5 MINUTES AFTER POWER UP FOR STABILIZATION CS101 is sensitive to metal objects that move through its field, including bicycles, horses, small vehicles or metal in shoes. Reduce the sensitivity as required to eliminate detection. In areas with high pedestrian traffic, the probe may be buried up to 24 deep to prevent triggering the detector by the metal in shoes. CS101 Operating Instructions 2

PRODUCT OVERVIEW The CS101 is a compact vehicle motion detector that operates by detecting changes in the earth s magnetic field that occur near the probe. These changes are produced by the movement of ferrous materials such as cars or trucks within the probe s range. The CS101 uses the CS101 series direct burial probes placed adjacent to a roadway or buried in a concrete or asphalt roadway. The probe features a 12ft. detection range that is dependent on the speed and size of the vehicle. The probe is available in a wide variety of cable lengths. The CS101 features adjustable sensitivity and output on time. A green LED is indicates that power is applied to the unit while a red LED indicates detection. The output consists of form C relay contacts (N.O, N.C., C). The CS101 may be used as a free exit sensor in both commercial and residential applications. The detector is not for use as a presence detector. When presence detection is needed, use the EMX D-TEK series detectors and inductive loop. Specifications Range sensitivity Sensitivity adjustment Output on time adjustment Surge protection Relay output configuration Relay contact rating Detect indicator Power indicator Power Standby current Detection current Operating temperature CS101 housing material CS101 dimensions (L x W x H) CS101 weight Probe housing material Probe dimensions (L x Dia.) Probe cable 12 ft. @ 5mph min. speed Dependent on mass and speed 0.5 6 seconds Probe input circuitry protected by surge suppressors Form C (SPDT) 1A @ 24VDC, 1A @ 120VAC Red LED Green LED 9 41VDC or 6 29VAC and 110VAC Model 2.5mA 50mA -40 C 82 C (-40 F 180 F) 0 95% relative humidity Polycarbonate 3.35 (84mm) x 1.6 (41mm) x 2.2 (55mm) 0.25 lbs. (113g) PVC water-tight 17 (432mm) x 1 (25mm) 3-wire, shielded, direct burial CS101 Operating Instructions 3

OPERATION After allowing a 5-minute stabilization time the CS101 is ready for use. It is possible that the detector will cycle during the power up stabilization period, this is normal. The CS101 relay contacts provide the means of indicating to the gate operator or other external equipment, that a vehicle has been detected. Since the CS101 is designed to detect motion it is not suitable for use as a presence detector. The green LED on the CS101 front panel indicates that power is applied to the unit and should always be on. The red LED on the front panel indicates detection and the activation of the output relay. The sensitivity adjustment allows the installer to set the system sensitivity for reliable operation. Rotate the adjustment counter-clockwise for minimum sensitivity and clockwise for maximum sensitivity. The output delay adjustment controls how long the output remains activated upon detection; minimum is approximately ½ second while maximum is approximately 6 seconds. Sensitivity is a function of speed and mass; the slower a vehicle is moving, the closer the vehicle must pass the probe to trigger the detector. CONTROLS AND INDICATORS CS101 Operating Instructions 4

INSTALLATION GUIDELINES POWER SUPPLY Do not exceed 41VDC or 29VAC. Power requirements are 9 41 VDC or 6 29 VAC PROBE STANDARD INSTALLATION BURY PROBE 8 12 DEEP HIGH PEDESTRIAN TRAFFIC BURY PROBE 24 DEEP CS101 is sensitive to metal objects that move through its field, including bicycles, horses, small vehicles or metal in shoes. Reduce the sensitivity as required to eliminate detection. In areas with high pedestrian traffic, the probe may be buried up to 24 deep to prevent triggering the detector by the metal in shoes. Do not install the Probe or lead wire near or parallel to: Low voltage lighting wires Telephone lines or intercom systems Electric motors or control relays Overhead power lines and transformers or underground power lines Cell phone towers, TV towers or communications links Moving metal flagpoles, fences, gates or horses with metal shoes Do not mount on any moving surface such as bridges or walkways may vibrate under traffic Underground water lines Probes are available in various cable lengths, when possible select the appropriate cable length for the installation. If it is necessary to extend the cable length, use a high quality lead-in cable suitable for direct burial, and a high quality, watertight cable splice to prevent moisture from entering the cable causing false triggering. A splice kit (Part no. 3M SPLICE KIT) and lead-in wire is available from EMX. All splices must be waterproof. When there is a high incidence of damage from burrowing animals or other potential damaging activities, it is recommended that the cable be placed in plastic conduit (1 ½ I.D.) to prevent damage to the cable. Damage to the cable jacket may allow moisture to enter the cable causing false triggering. When placing the probe in plastic conduit, use foam or tape to assure that the probe does not move or vibrate. It is recommended that the conduit be sealed to prevent water from collecting in the conduit. The probe must always be installed in such a way that it remains completely motionless. Any movement will cause the probe to trigger. CS101 module The detector is sensitive to minute changes in the magnetic field around the probe. Power lines, transformers, and other electrical devices located in the vicinity of the probe that produce transients could cause disturbances in the magnetic field that may result in triggering the detector. Avoid installation of the probe near these devices. The detector sensitivity is a function of mass and speed. A larger, fast moving vehicle will be detected at a greater distance than a smaller, slow moving vehicle. With this in mind, consider the distance of the probe to normal residential traffic, truck traffic, railroad, etc. As a general rule, probe distance to a road way should be a minimum of 40 while probe distance to a railway should be a minimum of 100. CS101 Operating Instructions 5

IMPORTANT: EARTH GROUND CONNECTION The CS101 contains transient protection devices to guard the sensitive electronic circuitry from damage and false triggering due to electrical transients caused by lightening or other sources. Always provide a good earth ground. A 5ft copper rod or cold water pipe provides a sufficient earth ground connection. Both the probe shield and PIN 6 of the CS101 must be connected to this earth ground. PROBE INSTALLATION ADJACENT TO ROADWAY Please read INSTALLATION GUIDLINES prior to installation. When the detector is set to maximum sensitivity (full clock-wise on the sensitivity adjustment) detection distance is approximately 12ft at a speed of 5mph. At higher speeds, 10-15mph, detection distance can exceed 12ft. 1. Prior to permanent installation adjacent to the roadway, place the probe in the desired location; connect the probe to the CS101 and power, output contact and earth ground to the intended equipment. Both the probe shield and PIN 6 of the CS101 must be connected to the earth ground (reference EARTH GROUND CONNECTION in the INSTALLATION GUIDELINES section). 2. Place the probe parallel to the roadway (driveway) in the desired location. 3. Apply power and allow 5 minute warm-up for system stabilization. 4. Set sensitivity to minimum and delay to maximum. 5. Drive the vehicle past the probe at a typical speed and to the far side of the roadway. 6. Repeat this step while gradually increase the sensitivity until the system detects the vehicle. 7. Bury the probe approximately 8-12 deep or 24 deep (see INSTALLATION GUIDELINES) at this location and repeat the previous sensitivity check (step 2-5), adjust the sensitivity as necessary to detect the vehicle. A higher sensitivity setting than required to detect the vehicle makes the system more vulnerable to triggering from unintended sources such as movement of other objects in the sensitive area or other electrical disturbances. Typical Installation CS101 Operating Instructions 6

PROBE INSTALLATION IN A ROADWAY Please read INSTALLATION GUIDLINES prior to installation. DO NOT INSTALL IN HOT ASPHALT When the detector is set to maximum sensitivity (full clock-wise on the sensitivity adjustment) detection distance is approximately 12ft at a speed of 5mph. At higher speeds, 10-15mph, detection distance can exceed 12ft. 1. The probe should be positioned in the center of the roadway, perpendicular to the direction of traffic. Place the probe in plastic conduit to prevent damage to probe and cable. Probe should be located at approximately 2 depth in concrete or asphalt. The probe may be located prior to paving, or a cut may be made in the pavement for installation. No rebar should be above the probe. 2. Once the probe is installed, connect the probe to the CS101 and power, output contact and earth ground to the intended equipment. Both the probe shield and PIN 6 of the CS101 must be connected to the earth ground (reference EARTH GROUND CONNECTION in the INSTALLATION GUIDELINES section). 3. Apply power and allow 5 minutes warm-up for system stabilization. 4. Set sensitivity to minimum and output delay to maximum (approximately 6 seconds). 5. Drive the vehicle over the probe at a typical speed and each side of the roadway. 6. Repeat this step while gradually increase the sensitivity until the system detects the vehicle. A higher sensitivity setting than required to detect the vehicle makes the system more vulnerable to triggering from unintended sources such as movement of other objects in the sensitive area or other electrical disturbances. Troubleshooting Symptom False triggering Possible solutions Possible cause Electrical disturbances Damaged probe cable Moisture in the probe cable Movement in the probe s environment 1. Verify that the earth ground connection to the CS101 and the probe shield is secure. If the connection is not secure, reconnect to the earth ground and retest the system. 2. Inspect the area around the probe for any metal object that may move such as signs or fences. 3. Disconnect the probe wires and see if the false triggering continues. If the false triggering stops, check the probe as outlined below. If the false triggering continues, disconnect the power and temporarily connect a 9V battery to the CS101 and reconnect the probe. Wait 5 minutes for the system to stabilize. If the false triggering stops, consider using a separate power supply for the CS101 such as a 120VAC to 12V power converter (min. 100ma). Re-connect the probe and test the system. 4. If the false triggering continues, inspect the area around the probe to see if any metallic objects may be subject to any movement. These may include fences, flagpoles, signs, etc. Other possible causes are electrical power lines, electric motors and high power lighting. Checking the probe If the false triggering stops when the probe is disconnected and other possible causes have been ruled out, then the likely cause is damage to the probe cable. CS101 Operating Instructions 7

A gross check may be performed on the probe as follows: 1. Disconnect the probe wires from the CS101. 2. Using a DVM set to measure ohms, verify that the resistance is 950 ohms +/- 10% the black and red wires. If not, then the probe/cable is defective. 3. Set the DVM to measure a minimum of 20 megohms and check the resistance between the red wire and the shield wire. Verify that the meter indicates open (infinity). Repeat this measurement on the black wire to the probe shield wire. If either measures a value, then there is moisture or damage to the probe and it must be replaced. Symptom No output (but red LED indicates detection) Possible cause Bad connection Failed relay Checking the CS101 output contacts 1. Disconnect the output contacts from the operator. 2. Connect a DVM, set to read ohms, to the COM and N.O. contacts. 3. The DVM should read open (infinity). Move a metal tool over the length of the probe, verify that the red LED turns on and that the DVM reads less than 10 ohms. Symptom No detection Possible cause Minimum 5 mph Bad connection Faulty power connection Failed relay 1. Check to see if the detection LED turns on, if so, check the relay output and related connections. 2. Verify that the green LED is on, if not, check the supply voltage using a DVM. Verify the voltage is 9 41VDC or 6-29 VAC. CS101 Operating Instructions 8

Wiring diagram LD-11B Socket Base Pin no. Description 1 Power + (9 to41vdc or 6-29VAC) or 110 VAC model 2 Power ground (9 41VDC common or 6-29VAC) or 110 VAC model 3 RELAY 1 - N.O. (relay, normally open contact) 4 RELAY 1 - Common (relay common contact) 5 RELAY 1 - N.C. (relay, normally closed contact) 6 Probe shield wire Earth ground (provides connection for transient and noise suppression devices) (reference EARTH GROUND CONNECTION in the INSTALLATION GUIDELINES section) 7 Probe (red wire) 8 Probe (black wire) 9 RELAY 2 - N.O. (relay, normally open contact) 10 RELAY 2- Common (relay common contact) 11 RELAY 2 - N.C. (relay, normally closed contact) CS101 Operating Instructions 9

Ordering information XC101-LV XC101-110 CarSense Vehicle motion detector, 9 41VDC and 6 29 VAC CarSense Vehicle motion detector, 110 VAC Accessories LD-11B Socket base, black, 11-pin, DIN rail mount (1 included) LD-11 Socket base, gray, 11-pin, DIN rail mount HAR-11 Connector, 11-pin, free-hanging with 36 wire harness 240-56857 Power convertor, 110VAC to 12VDC PROBE-50 PROBE-100 PROBE-150 PROBE-XXX CS 101 direct burial probe, 50 ft. lead-in wire CS 101 direct burial probe, 100 ft. lead-in wire CS 101 direct burial probe, 150 ft.lead-in wire CS 101 direct burial probe, enter required lead-in wire length (ft.) Warranty CS101 Operating Instructions 10

BLANK CS101 Operating Instructions 11

4564 Johnston Parkway Cleveland, Ohio 44128 United States of America WEB http://www.emxinc.com Technical Support Telephone (216) 834-0761 E-mail technical@emxinc.com Sales Telephone (216) 518-9888 Fax (216) 518-9884 Email salessupport@emxinc.com Revision 1.5 07/10/2013 CS101 Operating Instructions 12