1701/22 FieldMonitor Management Interface Module



Similar documents
3500/22M Transient Data Interface

3500/40M Proximitor* Monitor

3500/62 Process Variable Monitor

3500/25 Enhanced Keyphasor*Module

3500/93 System Display

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

and Accelerometers

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Low Frequency Velocity Sensor

Dynamic Pressure Charge Amplifier

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Velomitor Piezo-velocity Sensor

Provides one channel for Ethernet over existing

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

DeltaV SISnet Repeater

Foxboro Evo Process Automation System

Redundancy Module QUINT-DIODE/40

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

TrueAlarm Fire Alarm Systems

Provides one channel for Ethernet over existing

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Description. Dimensions. Features. precision works better

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

CompactLogix Power Supplies Specifications

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

MACTek Corporation. USB HART Interface. Users Manual

Proximity Transmitters and Seismic Vibration Transmitters

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

How To Power A Schen

Rosemount 333 HART Tri-Loop

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Waveguide Access Point WGA631. Product Guide

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

Differential-Hall-Effect based Sensors Series A5S

Rosemount 333 HART Tri-Loop

DeltaV Control Network Hardware

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Power Supplies 3. SDN-P DIN Rail Series

NI USB-5681 RF Power Meter Specifications

Unidirectional Transmitter/ Receiver Units Introduction

CompactRIO crio-9052

Telephone- and leased line modem for industrial applications TD-36

Adjustment functions for both span and shift have been incorporated

M-series MD Plus Controller

3300 XL 8mm Proximity Transducer System Bently Nevada* Asset Condition Monitoring

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

NAFEM Gateway User s Manual For Watlow part numbers NGW , NGW , NGWC , NGWC

Quick Installation Guide. EtherFast 10/100M Switch. Model No.: SP624R.

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

Moxa EtherDevice Switch

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

R&S ZNBT8 Vector Network Analyzer Specifications

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

NetScanner System. Toronto: , Montreal: , Toll Free: ,

Part Number Revision A, January Monitoring System Rack Configuration and Utilities Guide

Long Range Ethernet Extender

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

S-series SQ Controller

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

Indoor / Outdoor Antenna

PCS0100en Persy Control Services B.V. Netherlands

DMX2PWM 9 Channel Dimmer Setup Manual

1900/65A General Purpose Equipment Monitor

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

The quadrature signals and the index pulse are accessed through five inch square pins located on 0.1 inch centers.

ZC-24DO CANopen I/O Module: 24 Digital Outputs

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

KNX Panasonic Air Conditioners

Current Probes. User Manual

NETWORK ENABLED EQUIPMENT MONITOR

1900/65A General Purpose Equipment Monitor

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

GEU Port Gigabit Switch

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Plena Two-zone Call Station. Installation and User Instructions PLE-2CS

LIEBERT VNSA Installation Sheet

ORION TELECOM NETWORKS INC. T1

Transcription:

1701/22 FieldMonitor Management Interface Module Bently Nevada Asset Condition Monitoring Description The 1701/22 FieldMonitor Management Interface Module (FMIM) is a highlyintegrated module that provides the information interface to software that manages machine performance. The module captures data values and waveform files under transient, alarm and steady state conditions and provides this information to Data Manager 2000 machine management, Machine Condition Manager 2000 decision support software, and System 1 software (starting with version 4.0). The module inserts directly into the 1701 terminal base on the machine skid to form one management node. It provides the data interface for up to 8 channels of monitor data. It can then interconnect with additional management nodes to form a distributed machinery management data collection system. The module draws its power from the 1701 system, accepts transducer signals pre-wired in the terminal base, and communicates using an Ethernet local area network. Page 1 of 7

Specifications Inputs Dynamic signal Static signal Network signal Inter-module signals Outputs Status LED TX/RX LED Conditioned Keyphasor Digitally sampled waveform passed from monitors via terminal base. Overall amplitude and gap values are passed digitally from monitors via terminal base. 9-pin D series female connector for Ethernet connection. 9-pin Euro terminal for Keyphasor signals between nodes. Connector accepts wire gauges from 16 to 26 AWG. Tri-color LED indicates status of power, Keyphasor transducer, configuration, and module by combinations of color and flash rate. Tri-color LED indicates status of Ethernet link and transmission by combination of color and flash rate. See Keyphasor Signal topic below. Signal Conditioning - Specified at +25 C (+77 F). Direct Gap 1X, 2X Amplitude Range Refer to the monitor data sheet for direct specifications Refer to the monitor data sheet for gap specifications Accuracy Filter Response 1X, 2X Phase Range Accuracy Filter Response Minimum Amplitude Not 1X Range 1X Rejection Accuracy Same as Direct value ± 0.5 % FS, (20 to 60000 cpm) Constant Q filter. Q = 11. Stopband begins at ± 0.14 times the center frequency. Minimum rejection in stopband is 57 db. Filter settles in 19 shaft revolutions (100% settled) 0 to 359 degrees ±1 degree (100 mv minimum amplitude at 60000 cpm) Constant Q filter. Q = 11. Stopband begins at ± 0.14 times the center frequency. Minimum rejection in stopband is 57 db. Filter settles in 19 shaft revolutions (100% settled) Phase is marked invalid for signal amplitudes less than 5.4 mv. Same as Direct value Constant Q notch filter. Q = 2.98. Stopband begins at 0.97 and 1.03 times the center frequency (1X). Minimum rejection in stopband is 30.45 db ± 3% Page 2 of 7

Line length Frequency Range 30.4 m (100 ft.) maximum Keyphasor Signal Conditioning Transducer Input Speed range Speed Accuracy Voltage range Duty Cycle Minimum Amplitude Hysteresis range Error detection 7.2 Hz to 15.8 times speed (32X sample rate) 7.2 Hz to 31.8 times speed (64X sample rate) 7.2 Hz to 63.8 times speed (128X sample rate) 20 to 60000 cpm ±0.01% FS (7 Vpp square wave input) 0 to 24 Vdc Greater of 1% or 50 µs 0.5 Vpp (square wave) 0.2 V to 2 V (0.1 V increments) Not OK for voltage more positive than 1 Volt, data invalid for greater than ±25% period changes between shaft revolutions. Conditioned Input Voltage: Common mode range Dynamic Data Synchronous Waveforms Sample rate Length Filter Response Asynchronous Waveforms Differential pulse. High greater than +0.8 V. Low less than 0.8 V. -7 V to +12 V Software selectable. 128 samples / revolution (20 to 15000 cpm). 64 samples / revolution (20 to 30000 cpm). 32 samples / revolution (20 to 60000 cpm). 1024 samples. No anti-alias filters on synchronous path. Phase reference Conditioned Output Voltage Software selectable for leading edge of notch or projection. Fixed width differential pulse. High +1.5 V minimum, +5 V maximum. Frequency Spans Length Software specified 50, 100, 200, 500, 1000, 2000, 5000, 10000, 20000 Hz corresponds to sample rates of 128, 256, 512, 1280, 2560, 5120, 12800, 25600, 51200 Hz respectively. 1024 samples. Low 1.5 V minimum, -5 V maximum. Filter Response. Page 3 of 7

Module attenuates frequencies outside of the configured frequency span 80 db minimum. Coast-down captures data in both increasing and decreasing directions. Noise Floor Alarm Buffer Less than 0.002 V pp Data Buffers: Note: Static records consist of one value for each of the conditioned outputs (direct, gap, 1X and 2X amplitude and phase and Not 1X) along with status; dynamic records consist of 1 synchronous and 1 asynchronous waveform: Delta Time Buffer Capacity: Capture interval Transient (RPM based) Buffer Quantity Capacity RPM capture Interval Maximum capture rate Trigger modes 320 static records and 32 waveform records. (Module takes waveforms within 4 seconds after the even minute.) Static records every 4 seconds. waveforms every 40 seconds (10:1 ratio). 2 independent identical buffers 320 static records and 32 waveform records. (40 static and 4 time based waveform records just prior to buffer trigger, 280 static and 28 waveform records are posttrigger rpm based.) 1 to 60000 rpm. 50 records/second. Startup captures data in increasing rpm direction only. Capacity Update rate Trigger modes Ethernet Signals Baud Rate Protocol Interface Cable length Connection General Dimensions (H x W X L) Weight Power Consumption 40 static records and 4 waveform records. Static records every 4 seconds, waveforms every 40 seconds (10:1 ratio). A waveform is taken at the time of the alarm buffer trigger. Alert or danger alarm event in monitor or by software command. 10 Mbps fixed rate TCP/IP with BNC proprietary message content. Interface conforms to ISO/IEC 8802-3 1996 (formerly IEEE 802.3) 100 m (328 ft) maximum 9-pin female D style connector. 173 x 22 x 114 mm (6.8 x 0.9 x 4.5 in) 0.45 kg (1 lbm.) 2.3 W (maximum over temperature range) Page 4 of 7

Mounting Environmental Limits Operating Temperature: Keyphasor slot of 1701 terminal base, fastened with 2 6-32 captive screws. -20 C to +70 C (-4 F to +158 F). Hazardous Area Approvals North America 24 Vdc power source to the 1701/10-power supply is approved to the Low Voltage Directive. Ex na IIC T4 Class I, Zone 2 Storage Temperature: Operating or storage humidity: Vibration: Shock: -40 C to +85 C (-40 F to +185 F). 95%, non-condensing. 2 g s (10 to 500 Hz) Certification Number European/ATEX Class I, Div 2 Groups A, B, C, D Per drawing # 139255 CSA 1166985 CE Approvals EMC Directives: EMC Standards Low Voltage Directive: 6-inch drop to plywood surface (installed in terminal base). FMIM has the CE mark and is approved for installation within the European Union and EEA regions. FMIM has been designed and tested to meet the listed directives. This product is tested to meet Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) and the listed standards, in whole or in part, documented in a technical construction file. EN50081-2EMC Generic emission standard, Part 2, Industrial environment. EN50082-2EMC Generic immunity standard, Part 2, Industrial environment. FMIM meets Council Directive 73/23/EEC Low Voltage when the Brazil II 3G EEx na [L] IIC T4 LCIE 00ATEX6016X II 1/3 G EEx na[ia] ia IIC T4 LCIE 00ATEX6017X Br-Ex na [nl] IIC T4 MC, AEX-8304-X Page 5 of 7

Ordering Information FieldMonitor Management Interface Module 1701/22-AXX A: Approvals Data Manager 2000 Software 2700/01-AXX 0 1 Division 2/Zone 2 Data Acquisition Software 2700/03-AXX with Modification 145001-XX Display Software with FMIM Incorporation A: Type of purchase 0 1 Initial Purchase 0 2 Revision/Updates 145001-XX = 0 1 through 1 2 for the corresponding number of FMIMs System 1Software For System 1 option information go to www.geenergy.com/system1 Ethernet Cable Teflon -jacketed, screened twisted-pair (ScTP) cable with one 9-pin D-sub and one RJ-45 connector suitable for 10Base-T Ethernet applications in industrial environments. 141976-AXXX-BXX A: Length B: Insulation 0 1 0 10 foot cable (3.05 m) 0 2 5 25 foot cable (7.62 m) 0 5 0 50 foot cable (15.2 m) 1 0 0 100 foot cable (30.4 m) 2 5 0 250 foot cable (76.2 m) 0 1 Teflon insulation DC Powered Industrial Ethernet Hub 02200233 DIN rail mounted industrialrated 4-port hub powered from +24 Vdc power source. Page 6 of 7

Figures and Tables Note: All dimensions shown in millimetres (inches) unless noted otherwise. 1. Inter-module Keyphasor Connector 2. Status LEDs 3. DB-9 Ethernet Connector Figure 1: Mechanical Outline of the FieldMonitor Management Interface Module Bently Nevada, Data Manager, Machine Condition Manager, System 1 and Keyphasor are trademarks of General Electric Company. Teflon is a trademark of E.I. dupont de Nemours and Company. Copyright 2000. Bently Nevada LLC. 1631 Bently Parkway South, Minden, Nevada USA 89423 Phone: 775.782.3611 Fax: 775.215.2873 www.ge-energy.com/bently All rights reserved. Page 7 of 7