TS510 & TS500. Installation & User Guide. Compatible Equipment



Similar documents
9452/9453 Installation and User Guide

500r+ Installation and User Guide

9448 Installation and User Guide

ACTIVE 5 ENGINEERING MANUAL

TS590. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT 0 ESC

CONTENTS 4. HOW TO UNSET THE PANEL...7

Accenta/Optima. Engineer s Manual. Honeywell Security. 8SP399A - Accenta mini panel with remote LCD keypad and communicator outputs.

UNSET TAMPER FINAL EXIT

Intruder alarm system Engineering Information

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

How To Set A Timer On A Gg System

Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

User.QXD 09/05/00 14:47 Page 1 Gardtec /582 User Instructions

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panels. Issue 12

SECURIT 800L+ CONTROL PANEL

XR1. Intruder alarm system Operating Instructions. Unset system indications. Set System indication

Intruder alarm system Operating Instructions

User s Information Guide R1A

ACP10 10 Zone Intruder Alarm System

HARDWIRED CONTROL PANELS

USER GUIDE HARDWIRED CONTROL UNIT

SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL

User Guide Veritas 8/Veritas 8Compact/Veritas R8 INS036-5

i 70 Installation Manual V1.04 Contents Grade 2 Wireless Intruder Alarm System YOUR SECURITY IS OUR PRIORITY Installation Instructions 2

AC-115 Compact Networked Single Door Controller. Installation and User Manual

IMPORTANT USER INFORMATION

SECURIT 800L+ CONTROL PANEL

INSTALLATION MANUAL CONTENTS

AUTODIALLER / QUICKDIALLER - SA132

IDS X-Series User Manual D Issued July 2012

Intruder alarm system Engineering Information

Speech Dialler Engineering Information

Security System User Guide

Galaxy 2 Series. User Guide. Honeywell Security

Users Guide to Keypad Functions

How To Program An Autodialer

Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

Solution-16 Operators Manual ISSUE 1.60

Master User Guide Premier Elite 24/48/88/168/640

Using your LED Plus keypad

astec Integrated Alarm System USER GUIDE

Auto Dialer. Manual E-921APQ E-921GPQ

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

Installation and Programming Guide

SD1+ Speech Dialler. Installation and Programming Guide. Programming

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

D200+ Auto-Dialler Installation/Operators Manual

SD2. Speech Dialler. Installation and Operator s Manual

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide

SECURITY SYSTEM NOTES

NESS D Zone Control Panel and Dialler OWNER S MANUAL

Control/Communicator Installation Manual

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

CA60 Plus Software Version 3.1 User Manual May 2000

Secure Keypads for access control

FIREDEX Conventional Fire Panels

Speech Dialler Engineering Information

Security System Installation and Programming Guide

Master User Guide Premier Elite Series

Digital Keypad Use s Manual

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

HILLS Series LED Code Pad User Manual

Solution 862 Operators Manual. Issue 1.00

tattletale User Guide Consumer unit version P a g e

NetworX NX-6V2. LED Keypad User Manual

Solution 880 Operators Manual ISSUE 1.10

EURO User Manual. Castle Care-Tech 2012 (RINS1531) Issue 2. Page 1

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

MATRIX 6/816. Control Panel with Remote Keypads Software Version 1.34 USER MANUAL RINS545-7

USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT

LW A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets

ALARM SYSTEM USER GUIDE

SECURITY SYSTEM NOTES

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panels with Integrated Communicator INS159-9

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

Vision Security System OWNER MANUAL V-LCD1

1R / 4-BUTTON SERIES

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

Microprocessor Home Security System

AD-01 Slave Auto Dialer. Owner s Manual

Automatic Telephone Dialer TD-101(W)

ICP-CC488. Installation Guide ICP-CC488 Control Panel

Diamond + User Manual. Wireless Alarm System. Default codes: User code: 1234 Master Manager Code: 2222

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

!"#$%&"'()**+),-+)).( /'0%1##1%&"'(21'$1#( ISSUE 1.40

Programming & Installation PIEZO WARNING. EN : 2009 EN : 2008 EN : 2005 Security Grade 2 Environmental Class II RINS1347-2

SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS

ICP-CP500. User's Guide ICP-CP500 Codepads

WIRELESS HOME ALARM SYSTEM (WHA1)

PA4. 4 Zone Wired Intruder Alarm System. Installation & Operating Manual. MAINS CLEAR 24Hr. Zone 1 Zone 2 Zone 3 Zone 4

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

USER INSTRUCTIONS CONTENTS

ADEMCO LYNXR-I Security Systems

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Transcription:

Installation & User Guide Compatible Equipment TS510 REM - Remote Keypad 9040 - Loudspeaker DC54/58 - Digital Communicator SD1+ - Speech Dialler 496525 Issue A 1 of 10 TS510 and TS500

Overview Introduction This installation manual is intended to help you install the TS510 as quickly and easily as possible. It is therefore very important to read the manual thoroughly before starting any work. This is particularly significant if it is your first TS510 installation. The TS500 was the predecessor to the TS510. The differences between the two panels are noted throughout this guide. Specification 5 Programmable Zones with individual Tamper circuits, plus fixed PA and Exit Terminator Outputs for Bell, Strobe and 16 Ohm Loudspeaker Optional Remote Keypad (1 only) and Keyswitch Plug-on digicom DC3 or plug-on interface (TS500/510.IF) for connection to digicoms DC3, Redcare STU, Paknet etc. Conforms to BS4737: Part 1: 1986 Input Voltage: Panel DC Current: REM DC Current: Current Available: Battery Capacity: Dimensions: Weight Panel Remote Keypad Weight Keypad Environment: 24 + 10% 50Hz 30mA, 100mA in alarm 10mA 750mA MAX (AUX + Bell Current) 12V, 2.6/3.2Ahr (batteries not supplied) W x H x D 260 x 213 x 85mm 1.5Kg 125 x 127 x 32mm 200g 0-55 C (INDOORS) VOLUME CONTROL BATTERY REVERSAL INDICATOR PCB CLIP 1 2 3 4 5 POWER TAMPER CALL ENGR PA EXIT AUX FUSE B1 (1A) ACCESS TO TAMPER SPACE FOR BATTERY NOVRAM BELL FUSE F2 (1A) 123 456 789 FUNCTION 0 UNSET Figure 1 - TS510 Assembly Layout TS510 & TS500 2 of 10 496525 Issue A

System Wiring TS510 & TS500 All ZONE and TAMPER inputs are linked out prior to despatch from the factory. Remove these links from those zones which are to be used, but leave the links in unused zones. The EXIT TERMINATOR link MUST BE REMOVED even if this facility is not used, otherwise all programmed information will be lost on total power loss (mains and battery). PLANNING AND INSTALLING THE WIRING:- 1. Ensure that the mains cable, circuit cables and telecom cables are kept separate, and that mains cable enters the housing as near to the fused terminal block as possible. 2. Ensure that the circuit, tamper and remote keypad cables are not routed adjacent to AC or RF cabling and are not run in multicore cables with bells or sounders. 3. Insulation testing should only be carried out when the cable under test is disconnected from electronic circuitry at both ends. NOTE: TS500 Aux TMP = Main & Bell TMP OP1 OP2 = WLK TST = SW 12V 4K7 2K2 2K2 ALM TAMP 2K2 (2200) OHMS RED RED RED END OF LINE RESISTOR ALM TAMP TO ZONE MOVEMENT DETECTOR WIRED END OF LINE +12V ALARM TAMPER 4K7 2K2 AC IN + AUX 12V - ZONE 1 TAMP 1 ZONE 2 4K7 (4700) OHMS YELLOW VIOLET RED SHUNT RESISTOR MAGNETIC CONTACT WIRED DOUBLE POLE Alarm Tamper TAMP2 ZONE3 TAMP 3 ZONE 4 Normally Open Keyswitch Normally Open Pushbutton TAMP 4 ZONE 5 Normally Closed P.A. Button ALARM TAMPER TAMP 5 EXIT TERM KEYSW/ F. EXIT P.A. AUX TMP STROBE - S.A.B/SIREN + -VE TAMPER RETURN +12 V - VE STROBE TRIGGER -VE BELL TRIGGER BELL TR - O/P1 O/P2 + H/O - STB - TRG - L/S+ 16 0HM LOUDSPEAKER Fig 2 SAMPLE Wiring Diagram (showing Double Pole and End of Line Resistor wiring) 496525 Issue A 3 of 10 TS510 & TS500

Remote Keypad Digital Communicator Up to 4 remote keypads (order code: TS510 REM), can be fitted, these are supplied with an interface which plugs onto the main panel PCB. The connections from the panel to the Remote Keypad require a five core cable (max length 50m). Assuming that the control panel covers have been removed, the cable is in place and that the mains supply and backup battery have been disconnected, installation is as follows: 1. Connect the cable to the interface connections A, B, C etc, and then carefully locate the interface in the slot at the bottom of the panel PCB. Replace the right hand cover assembly. 2. Separate the remote keypad cover assembly from the base by releasing the clips on the top and bottom of the housing. Place the base on the wall where it is required and mark the screw positions. Remove the base then drill and plug the wall. Fix the base to the wall. The DC3 is an 8 channel plug-on digital communicator specifically designed to operate with Menvier Security control panels, and is supplied with a lead for connection directly onto the main panel PCB. The unit has its own installation and programming instructions which must be referred to before proceeding with installation. The digital communicator is mounted behind the right hand lid assembly as appropriate. CAUTION: The mains supply and backup battery must be disconnected before connecting the DC3 to the main PCB. Other communication devices such as the DC28 Digicom, RedCARE STU, Pakent Interface Card etc. may be connected to the TS510 by using an optional interface card (TS510.IF). This is also supplied with its own installation instructions which should be referred to before proceeding with installation. Fig. 4 shows the TS510.IF connections when plugged onto the TS510 PCB. (See page 5) 3. Taking care not to damage the PCB assembly, connect the terminal blocks on the remote keypad to the cable, ensuring that the connections through to the control panel interface card are A to A, B to B etc. 4. Carefully re-attach the front cover assembly to the base ensuring that the cable is clear of the spring on the tamper switch, and the cover is securely clipped to the base. Finally re-connect the mains supply and test the operation of the remote keypad. 5. If more than 1 remote keypad is to be used, connections may be in a star or daisy chain configuration. NOTE: TS500 only compatible with TS500 REM. NOTE: TS500 only, link (LKI). If open the remote keypad will have full functions if closed you can only use remote keypad to set, part set and unset. NOTE: TS500 Only one remote keypad can be fitted TS510 & TS500 4 of 10 496525 Issue A

TS510 Digital Communicator Wiring TS500 Digital Communicator Wiring DC 3 CHANNELS 1=FIRE 2=PA 3 = ALARM 4 = SET/UNSET 5 = ENGINEER-ON-SITE TO DC. 3 DIGI INTERFACE REMOTE INTERFACE DC 3 CHANNELS 1=FIRE 2=PA 3=ALARM 4 =SET/UNSET 5 =ENGINEER-ON-SITE SPARE, PINS OR SHORTING LINK TO DC. 3 DIGI INTERFACE REMOTE INTERFACE TO REMOTE KEYPAD TO REMOTE KEYPAD Fig 3 DC3 and TS510.REM Connections Fit the DC3 connector to the TS510 plug as shown. Fig 5 DC3 and TS500.REM Connections Fit the DC3 connector to the TS500 plug after removing the polarity pin from socket 4. Ensure that the connector is fitted with the wings pointing away from the TS500 PCB, and the shorting link (or 2 spare pins) are above the connector. TERMINAL BLOCKS (top to bottom) TERMINAL BLOCKS (top to bottom) LINE FAULT (+ve Applied in Line Fault) 12V 8=FAULT 7 = DET RESET 6 = SW 12V 5 = ENGINEER - ON - SITE 4=SET/UNSET 3=ALARM 2=PA 1 = FIRE LF 12V 8 7 6 5 4 3 2 1 DIGI INTERFACE REMOTE INTERFACE LINE FAULT (+ve applied during line fault) 12V 8=SOUNDERON 7=BELLON 6=PARTSET 5 = ENGINEER - ON - SITE 4=SET/UNSET 3=ALARM 2=PA 1 = FIRE LF 12V 8 7 6 5 4 3 2 1 DIGI INTERFACE REMOTE INTERFACE TO REMOTE KEYPAD TO REMOTE KEYPAD Fig4 TS510.IF and TS510.REM Connection Fit the TS510.IF to the panel plug taking care to ensure that correct alignment is made and that no pins are visible. Fig 6 TS500/510.IF and TS500.REM Connections Remove the shorting link (if fitted) from the top 2 pins of the DIGI INTERFACE connector. Fit the TS500/510.IF to the panel plug taking care to ensure that correct alignment is made and that no pins are visible. 496525 Issue A 5 of 10 TS510 & TS500

Defaults ENGINEER CODE = 1234 OPTIONS 1: (NOT APPLICABLE TO TS500) MASTER USER CODE = 5678 Bell output is SAB LAST EXIT ZONE = ZONE 1 Alarm cleared on reset ACCESS ZONE = ZONE 2 Audible P.A. EXIT TIME = 30 secs. P.A. audible in line fault ENTRY TIME = 30 secs. Fire output signals during Full Set only BELL DURATION = 20 min. Output 1 is WALK TEST BELL DELAY = 0 min. Output 2 is SW12V REMOTE RESET REF = 004 KEY SW/F.EXIT input is full set keyswitch Set inhibited on mains fail OPTIONS 2: (NOT APPLICABLE TO TS500) Exit Terminator chimes Exit Terminator disabled Timed exit set Auto rearm User reset Key Functions Engineer s Reset 1. Enter Engineer code default 1234. The CALL ENGR LED will illuminate. You are now in Engineer mode. Bell Test/Walk Test Please refer to user function numbers 1 & 2 respectively. 2. Press 0 twice to return to unset. Loading Defaults 1. Power down panel mains and battery. 2. Wire in a small piece of cable across two terminals for exit terminator. 3. Power up battery and mains. 4. Enter 1234 and remove link. 5. The panel is now back to Factory Default Programming. TS510 & TS500 6 of 10 496525 Issue A

Engineers Programming ENTER ENGINEER CODE AND THE [CALL ENGR] LED WILL ILLUMINATE TOGETHER WITH THAT OF THE ZONE WHICH CREATED THE LAST ALARM. IF THE [CALL ENGR] LED FLASHES, THE LAST ALARM OCCURRED WITH A LINE FAULT PRESENT. OPTION DEFAULTS ARE SHOWN IN BOLD. To program any of the zones (1 to 5) as standard NIGHT circuits, simply ensure that they are not programmed as Last Exit, Access or Fire. To program any of the zones (1 to 5) as LAST EXIT circuits, press [1]. If any of the Zone LED s are ON, then these are already programmed with this option. To change zones simply enter the zone number, which will toggle the zone LED on/off. Once the setting is correct press [0] (END) and listen for the confirmation tone. LAST EXIT ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF DEFAULT = ZONE 1 ONLY To program any of the zones (1 to 5) as ACCESS circuits, press [2], If any of the Zone LED s are ON, then these are already programmed with this option. To change zones simply enter the zone number, which will toggle the zone LED on/off. Once the setting is correct press [0] (END) and listen for the confirmation tone. ACCESS: ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF DEFAULT = ZONE 2 ONLY To program any of the zones (1 to 5) as FIRE circuits, press [3]. If any of the Zone LED s are ON, then these are already programmed with this option. To change zones simply enter the zone number, which will toggle the zone LED on/off. Once the setting is correct press [O] (END) and listen for the confirmation tone ON ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF NO DEFAULT ZONES EXIT TIME: Press [4] and 3 zone LED s will light, indicating that a 3 digit exit time (in secs) is required, Once complete the confirmation tone will be heard. e.g. for 30 secs. enter 030 EXIT TIME DEFAULT = 030 SECS S ENTRY TIME: Press [5] and 3 zone LED s will light, indicating that a 3 digit entry time (in secs) is required, Once complete the confirmation tone will be heard e.g. for 30 secs. enter 030 ENTRY TIME BELL DURATION: DEFAULT = 030 SECS Press [6] [1] and 3 zone LED s will light, indicating that a 3 digit bell duration time (in mins) is required. Once complete, the confirmation tone will be heard. e.g. for 20 mins, enter 020. BELL DUR. BELL DELAY: BELL DELAY S m DEFAULT = 020 MINS Press [6] [2] and 3 zone LED s will light, indicating that a 3 digit bell delay time (in mins) is required. Once complete the confirmation tone will be heard. e.g. for 5 mins, enter 005 OPTIONS: 63-69 Not applicable to TS500 SIGNALLING OPTIONS: OFF m DEFAULT = 000 MINS Press [6] [3] and combination of zone LED s will light, each showing a different setup: BELL IS NO AUDIBLE PA NOT ON SAB ALARM PA AUDIBLE ABORT ON L.F BELL IS SCB SIGNALLING OF FIRE: ALARM ABORT SILENT PA PA SILENT ON LF NOT Press [6] [4] and combination of zone LEDs will light, each showing a setup: ON = FIRE UNSET PARTSET PARTSET FULL SET NOT SIGNALLED A B IN: ON/OFF ON/OFF ON/OFF ON/OFF NOT 496525 Issue A 7 of 10 TS510 & TS500

OUTPUT 1: Press [6] [5] and one of the following LEDs will light, showing which function is indicated by Output 1: ON WALK TEST SW12V DTR RESET ALARM NOT ON/OFF ON/OFF ON/OFF ON/OFF NOT OUTPUT 2: Press [6] [6] and one of the following LEDs will light, showing which function is indicated by Output 2: ON FAULT SW 12V DTR RESET PA NOT ON/OFF ON/OFF ON/OFF ON/OFF NOT KEYSWITCH FINAL EXIT: Press [6] [7] and one of the following LEDS will light, showing how the keyswitch input will operate. FULL SET PART SET PART SET FINAL NOT ON ON/OFF A ON/OFF B ON/OFF EXIT ON/OFF NOT VIEW EVENT LOG: Pressing [6] [8] will allow the event log to be viewed. Pressing [8] displays the last event whilst pressing numbers other than [9] and [0] displays earlier events in order, with [1] being the oldest event. To exit the routine, press [0]. SYSTEM SETTING OPTIONS: Press (6) [9] to select the system setting options. ENGINEER CODE: Press [7] and 4 zone LEDs will light indicating that a 4 digit engineer code is required. Once entered, re-enter the code for confirmation and listen for the confirmation tone. ENGR CODE REMOTE RESET CODE: OPTIONS: DEFAULT = 1234 Press [8] and 3 zone LEDs will light, indicating that a 3 digit code must be entered. Enter your code and listen for the confirmation tone. RESET NO. DEFAULT = 004 Press [9] and a combination of zone LEDs will light, each showing a different setup. To change any option, simply enter the number for the options required. Once the settings are correct, press [0] and listen for the confirmation tone. ON OFF ET/F EXIT SILENT ET/F EXIT CHIMES FINAL EXIT SET TIMED EXIT E.T. ENABLED E.T. DISABLED ENGINEER RESET USER RESET 3 REARMS 0 REARMS NOTE: Whilst in engineer mode, tampers are inhibited. To monitor tampers return the panel to the UNSET condition. NOTE: OPTIONS: No.5 on TS500 LED ON = AUTO RE-ARM, LED OFF = MANUAL RE-ARM ON OFF SET ALLOWED WITH MAINS FAILURE SET DISALLOWED WITH MAINS FAILURE RISING ENTRY AND EXIT TONES CONTINUOUS ENTRY AND EXIT TONES SET ALLOWS WITH LINE FAULT SET DISALLOWED WITH LINE FAULT NOT NOT NOT NOT TS510 & TS500 8 of 10 496525 Issue A

User Functions SETTING THE SYSTEM 1. Enter your passcode - the (UNSET) light will flash. 2. Wait 5 secs until the (FUNCTION) light goes out and the exit tone will start. Leave via the designated exit route, closing the door. 3. The system is set when the exit tone stops and the two tone confirmation tone is heard. NOTES: A) If the exit tone continues and (if fitted) the strobe light on the bell box is flashing the system has not set and you must re-enter the premises, re-enter the passcode and start again. B) If you change your mind whilst setting the panel and wish to unset it again press (0) (END) or wait until the (FUNCTION) light goes out and re-enter your passcode. PART SET THE SYSTEM 1. Enter your passcode - the (UNSET) light will flash 2. Press [7] (OMIT A) OR [9] (OMIT B) as appropriate - the zones omitted will flash. 3. After a pause the exit tone will start. 4. The system is part set when the exit tone stops. The following options may be accessed by entering the USER 1 passcode IN REVERSE ORDER (eg for passcode 5678 - enter 8765) followed within 5 seconds by the function key you require. These facilities are not available to User 2 who is restricted to Set, Part-set and Unset activities. NOTE: TS500 enter code in forwards and not in reverse for following functions Testing Sounders tone will start - press [1] (BELL TEST) immediately. 2. All panel lights illuminate followed by 5 second sequential activations of internal sounders, external sounders and strobe (if fitted). 3. Panel returns to [UNSET] condition on completion of testing. Testing Detectors tone will start - press [2] (WALK TEST) immediately. 2. Activate selected detectors or door contacts and smoke detectors if fitted. 3. Zone light illuminates and two tone sounder is heard for each device activated. 4. Press [0] (END) to complete test - [UNSET] will illuminate. Change User 1 Passcode tone will start - press [4] (USER 1) immediately 2. Four zone lights illuminate and 15 seconds is allowed to commence entry of the new code. 3. Enter new passcode extinguishing the four zone lights. 4. Four zone lights illuminate again. 5. Repeat new passcode (as confirmation). 6. Two tone confirmation sound heard - new passcode accepted - [UNSET] will illuminate. Change User 2 Passcode tone will start - press [6] (USER 2) immediately. 2. Four zone lights illuminate and 15 seconds is allowed to commence entry of the new code. 3. Enter new User 2 passcode extinguishing the four zone lights. 4. Four zone lights illuminate again. 5. Repeat new User 2 passcode (as confirmation). 6. Two tone confirmation sound heard - new User passcode accepted - [UNSET] will illuminate. Selecting Chime With the system unset you may wish to be alerted when door contacts or detectors are activated. You can set nominated devices to CHIME : tone will start - press [5] (CHIME) immediately. 2. Any zones set to chime will illuminate. 3. To add or delete chime zones press the relevant zone number within 15 seconds. 4. Zone lights indicate status (LIT=CHIME, UNLIT=NORMAL). 5. When satisfied press [0] (END). 6. Two tone confirmation sound heard - [UNSET] will illuminate. Change Part Set Areas If you wish to re-arrange your part-set areas: tone will start - press [7] (OMIT A) OR [9] (OMIT B) immediately as required. 2. Zone lights flashing indicate those zones omitted 3. To add or delete omit zones press the relevant zone number within 15 seconds. 4. Zone lights indicate status 496525 Issue A 9 of 10 TS510 & TS500

(FLASHING=OMITTED, UNLIT=NORMAL) 5. When satisfied press [0] (END). 6. Two tone confirmation sound heard - [UNSET] will illuminate. Fault finding [CALL ENGR] flashing Indicates there is a telephone line problem if you are connected to a monitoring station. Check telephone and call engineer. [CALL ENGR] illuminated Try re-set procedures or call engineer. [TAMPER] illuminated or flashing The panel sounder will probably be bleeping and a zone light: may be flashing. 1. Enter passcode to stop sounder 2. Check detection devices in zone indicated 3. If you can correct the fault do so and then enter your passcode and press [0] (END). System returns to UNSET 4. If fault cannot be remedied - call your engineer. (PA) illuminated 1. Manually reset Panic button with the key provided 2. Enter your passcode - PA indicator on 3. Enter your passcode and press [0] (END). [POWER] light out This will occur if there is a mains failure or power cut when the system will switch to reserve battery power for about 8 hours. If the power cut persists the system will go into alarm. If this happens enter your passcode to unset the system and call your engineer. TS510 & TS500 10 of 10 496525 Issue A