WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING



Similar documents
Window Installation Instructions

Sun Windows General Information Sun New Construction Window Installation Instructions

Clad Direct Glaze Window Installation Instructions

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

Tundra Series Windows January 2016

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

Basement Window Installation Guide Hopper and Sliding

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

INSTALLATION INSTRUCTIONS for Vinyl Windows without Nailing Fin (JII011) ImPOrTANT INFOrmATION & GlOssAry. rough OPeNINGs

INSTALLATION INSTRUCTIONS for Vinyl Patio Doors with Integral Nailing Fin (JII006)

4 5/16 Subframe Installation

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

Installation Guide for Andersen Architectural Wood Inswing Entry Doors

INSTALLATION INSTRUCTIONS for Premium Pocket Windows (JII022) IMPoRtaNt INFoRMatIoN & glossary. safety & HaNdlINg

WELCOME. Recommended Window Installation. 1.5 credits Minnesota Department of Labor and Industry

Installation Guide for Andersen Architectural Clad Outswing Commercial Doors

Brick Veneer Construction

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW

SERIES 238 WINDOWS. NOTE: Read instructions completely before attempting any installation.

INSTALLATION INSTRUCTIONS for Vinyl Patio Doors without Nailing Fin (JII015) IMPORTANT INFORMATION AND GLOSSARY

INSTALLATION INSTRUCTIONS for Swinging French and Patio Doors (JII105)

March 14, Installation of Bay, Bow and Garden Windows

300mm. 2mm MIN GAP. PLACE 100mm X 100mm. SO THAT IT IS 38mm INTO

Installation Instructions For Slider Casement Air Conditioners

DE Frame with C Series Sidelight

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

GreenGuard Housewrap Installation Guide

SLIDING PATIO DOOR INSTALLATION INSTRUCTIONS USING FRAME SCREWS

WINDOW INSTALLATION GUIDE

Replacement Installation Instructions

New Construction Stud Frame Vinyl Window Installation Guide

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS WINDOWS

AAMA Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

Installation Instructions

Vinyl Greenhouse Window Page 2 of 6 New Contruction Installation Instructions

Important Information for Installer & Homeowner

All-Season Sunroom Sliding Glass Door Installation Instructions

INSTALLATION OF A BAY WINDOW

Installer Training and Certification Overview

Installation Window Building In Details

PANELIZED HOME INSTALLATION GUIDELINE

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

Installation Instructions

WINDOW PANNING AND TRIMS

Packaged Terminal Air Conditioner Wall Sleeve Installation

DuPont Flashing Systems Installation Guidelines

450 SERIES SLIDING GLASS DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS

InsulView Window Installation Instructions

IMPORTANT! READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION. Step 1:

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

Barewood Octagon and Elongated Windows Installation Instructions

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Vinyl, Brick and Stone Claddings

Installing Window and Door Mouldings

Cable Support System Guide for Andersen Bow, Bay, and Box Projecting Window Units

Introduction...COMB-2 Design Considerations and Examples...COMB-3

The WANZ Guide to Window Installation

Active and Passive Sash Replacement

Installation Instructions

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Stone Veneer or Lap Siding, e.g. Fiber Cement and Wood/Cedar

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Premier & Deluxe 3-Season Room Sliding Glass Door

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

DuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Residential Single Family Houses Using Vinyl, Brick and Stone Claddings VERSION 10/13

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Hinge Replacement & Hinge and Hardware Adjustment Guide for Andersen Frenchwood Hinged Patio Doors Manufactured Before November 2005

How to Install UnderDeck The Original.

Angle Bay Window & Bow Window Installation Instructions

How To Repair A Boat Landing Deck With A Boat Bed

Sash Replacement Guide

Window Sill Details for Effective Drainage of Water

Calvert USA, Inc. Attic Stairs

Chapter 9: INSTALLING ROOFING

Installation Instructions

Residential Roofing Guide

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

Casement/Awning Window Parts Reference Catalog

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

H-Stud Area Separation Wall System

ISSUE 2. Installation Guide

The WANZ Guide to Window Installation

UNIVERSAL ASSEMBLY INSTRUCTIONS FOR VERSATUBE BUILDINGS CONTRACTOR SERIES 2 X 4 FRAMES

Classic Products, Inc. ClickLock Standing Seam Installation Manual

FAQs. 19. Does the sub floor need to be level before I install my new direct-to-stud bathtub or shower base?

Housewrap Errors. By Steve Easley

2.9 WINDOW & DOOR BUCKS

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

WINDOW REPAIR MANUAL & REFERENCE GUIDE

Optimum Windows Reliant Installation Manual

The Illustrated Guide to Installing Vinyl Windows VERSION 7.1

application instructions

Transcription:

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

IMPORTANT NOTICES AND INFORMATION Read these instructions in their entirety prior to installing windows. Any local building code requirements supersede these recommended installation instructions. Building design, construction methods, building materials and site conditions unique to your project may require an installation method different from these instructions, and additional care. Remove shipping blocks and related staples prior to installation. For Typical Wood Frame Construction: These instructions were developed and tested for use with typical wood frame wall construction in a wall system designed to manage water, with a weather resistant barrier applied prior to the window installation. These instructions are not to be used with other construction methods. PRECAUTIONS AND SAFETY: Do not work alone. It is recommended that at least two people work together to avoid personal injury or damage when working with windows. Use caution when handling glass. Broken or cracked glass can cause serious injury. Wear necessary protective gear (gloves, clothing, goggles, etc.). Secure tools, ladders or scaffolding. Follow equipment manufacturers operation instructions, warnings and cautions. Secure and properly support the unit until completely fastened. Materials Required Tools Required 2 Canada and U.S.A. 1.800.563.9367 International 204.326.6446 High impact shims (sloped, shim pack or Horseshoe Shims by Glazelock or equal) 1 1/2" (38 mm) #8 screws (stainless steel) OSI TeQ Foam for interior cavity seal OSI TeQ Flash Self Adhered Flashing 100' rolls (minimum 6" width on sill and minimum 4" on jambs and head). Check your code requirements Approximately 1-2 (depending on unit sizes) tubes of OSI TeQ Seal Sealant Tape measure Level Square Hammer Stapler Screwdrivers Scissors or utility knife Screw gun OSI TeQ Foam Applicator Caulk gun J Roller

exploded view to demonstrate sequence 1. verify the rough opening Measure the rough opening and the window to determine that the size is correct. Recommended rough opening is between 3/4" (19mm) - 1" (25mm) larger than the window width and height. Ensure that the rough opening is plumb, level and square, and the walls in the opening are not twisted. a) 1 1/2" (38 mm) solid blocking is required at the sill and sides of the opening. b) Ensure proper header is in place before installation. c) Make necessary corrections. 2. WRB should be applied per manufacturers instructions Cut out Weather Resistant Barrier with a complete box cut of the opening. Weather Resistant Barrier should NOT be brought into the rough opening. Create a temporary flap at the head of the opening by cutting the Weather Resistant Barrier on a 45 degree angle. Temporarily tape the flap up out of the way to allow for window installation and head flashings. 3 Cut back the Weather Resistant Barrier approximately 1 1/2"exposing the sheathing at the sides only. This will create a direct contact seal between the window flange and sheathing. www.loewen.com

3. Create TeQ Flash Sill Pan Cut a 4"x 6" rectangular TeQ Flash flashing. Fold the piece in half. Cut both corners leaving appox 1 1/2" in the center (see #3) Install these tightly in the corners to flash and seal the corner joints. This must be done allowing for tight adhesion into the corners with no air bubbles. I Cut a length of TeQ Flash flashing, using the formulas, at least 12" wider than the rough opening. Center the flashing left to right. Then set into the rough sill the same depth of the window or greater. With a utility knife, cut the flashing from the corner down the flashing that will expose the previously installed corner guard. (see drawing) Roll out and smooth with J roller. International 204.326.6446 4. set shims and level the sill condition Level the sill condition by first performing a "dry run" with the level and high impact PVC shims. Use high impact, Glazelock Shims or equal. After shims are determined to be level on the sill, proceed to set shims with OSI TeQ Seal under the shim and over the shim as shown in drawing 4 Shims should be placed on the sill 4" (100mm) from each end and at every mull. Make sure shim is placed in proper depth and not under the jamb extension. If shims are left in place then make sure they don't protrude past the interior window frame. Canada and U.S.A. 1.800.563.9367 Important: In a future step, the TeQ Foam being applied under the window needs to be a continuous seal at the sill with no protruding shims.

5. Prepare the window for installation Apply a heavy 3/8" OSI Teq Seal over the flange holes. On the bottom flange, leave a 2"void approx 2" from either end and under every mull joint. This will allow a drainage path for incidental moisture. Window must be installed before sealant dries. 3/8" DIAMETER BEAD OF SEALANT 6. set the unit and secure Two or more people may be required to accomplish this step. Set the window from the exterior into the rough opening Center the window in the rough opening and apply a 1 1/2" screw through the top corner of the flange. Shim the unit plumb square and level before applying a screw through every other flange hole. (do not angle or over tighten the screws). Apply shims 4" (100mm) from bottom and top, and one at the center. Operate the unit once it is completely fastened. 5 www.loewen.com

7. apply TeQ Flash at Jambs and at head After the window has been fastened, Teq Flash should be applied to the jambs and head. Use the formula for proper flashing lengths. Use a J roller or equal to push out all air pockets to ensure good adhesion. If at any time the flashing does not stick due to cold wet substrates, it is permissible to secure the flashing with a tack hammer and staples. FLASHING LENGTHS AND CUT FORMULAS Sill Flashing = RO W + 12" Jamb Flashing = RO H + (2 x flashing width) - 1" Head Flashing = RO W + (2 x flashing width) + 2" Legend RO = rough opening RO H = rough opening vertical (height) RO W = rough opening horizontal (width) 8. cut and install both flexible & rigid head flashing Appropriate head flashing must be applied to top of the unit. 6 Canada and U.S.A. 1.800.563.9367 International 204.326.6446 Apply a healthy bead of Teq Seal to both sides of the rigid head flash and fasten with 1 1/2" screws. Note: This step is not necessary if window unit has an integral drip cap fasten by the factory.

9. fold down top flap of weather resistant barrier Remove the previously applied tape holding the flap of the WRB at the head. Allow the flap to lay flat over the head flashing. Apply slices of OSI TeQ Flash over the diagonal cuts made in the WRB. Ensure that the entire cut is covered. 10. seal and insulate the interior cavity The rough opening should have enough tolerance to accept OSI Teq Foam for insulating purposes. From the interior, insert the nozzle of the applicator into the rough opening, hold the tip of the nozzle 1" (25mm) from the exterior window flange and apply a minimum 2" (50mm) bead of foam around the entire unit. NOTE : After the foam has set you may fill the entire rough opening cavity with OSI Teq Foam or fiber glass insulation. 11. window critical interface Exterior Facade should allow for 3/8" void at the perimeter of the window frame. This will allow for backer rod and high quality sealant at this critical interface. OSI Quad is highly recommended. 7 Apply backer rod in such a way to avoid puncturing backer rod. Punctured backer rod can off gas and cause sealant bubbling. Backer rod should be slightly larger than the void and fit snug into the void. Insert 3/8" and 10 mm backer rod into the space around the window. Provide at least 3/8" (10mm) clearance between the backer rod and the exterior face of the window. Backer rods add shape and depth for the sealant line. www.loewen.com

Henkel Corporation 26235 First Street Westlake, Ohio 44145 Customer Relations: 1-800-624-7767 This warranty is made solely on behalf of Henkel and not on behalf of any retail lumberyard establishment. Henkel Corporation 2010/33475

9 www.loewen.com

Call 1.800.563.9367 for the dealer nearest you. International 204.326.6446 www.loewen.com E-mail: info@loewen.com Distributed by Loewen Inc. in the U.S. and C.P. Loewen Enterprises Ltd. in Canada and internationally. Trademarks owned by C.P. Loewen Enterprises Ltd. Used under license. 2006 C.P. Loewen Enterprises Ltd. All rights reserved. SW-COC-1739 Recycled Paper Printed in Canada September 2006 P1015A