GREISINGER electronic GmbH



Similar documents
T0118 T2118 T3118. Instruction Manual

Electronic Pressure Switch EDS 300

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Duct Humidity Transmitter

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

GAE953 Electrical Alarm Unit 19" with Indicator

RRV934. Multi-controller. Synco living

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Digital input modules

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

UM-X Field display for continous level sensors

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Drayton Digistat +2RF/+3RF

Operating instructions IV / 2007

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

3M Wrist Strap and Footwear Tester 740. User s Guide

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Modular I/O System Analog and Digital Interface Modules

Elektromotoren und Gerätebau Barleben GmbH

Analog Command Value Card Type VT-SWKA-1

Hand-held thermometer Model CTH7000

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

Instruction Manual. T3111 T3111L T3111P T3111Ex

MOUNTING AND OPERATING INSTRUCTIONS

Electronic Pressure Switch EDS 3000

Infrarot-Bewegungsmelder IP44

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

INSTRUCTION MANUAL. SIGNAL AMPLIFIER 4-20 ma

Redundancy Module QUINT-DIODE/40

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Instruction Manual Copy Adapter "CPAD-C1A" "CP Fuji Electric Systems Co., Ltd. INR-SI a-EU Rev

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

SOUND LEVEL METER 94405

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Instruction Manual Differential Pressure Transmitter

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

HERZ-Thermal Actuators

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Analog signal converters CC-E I/I Current / current isolators

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Quick Connect. quick - simple - efficient.

ATL Fuel Level Sender Probes

Safety technique. Emergency stop module BO 5988 safemaster

How To Use An Ams 5812 Pressure Sensor With A Usb Starter Kit

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

3 740 Wrist strap + shoe tester

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

ST Series POWER SUPPLIES USER INSTRUCTIONS

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Combi B Alarm box. Mounting instructions

Digital display DA 48

HCR3.2/.. Chipcard reader HOTEL SOLUTION

AC-115 Compact Networked Single Door Controller. Installation and User Manual

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Multi-Protocol decoder with Load regulation

Rosemount 333 HART Tri-Loop

TCR easy Plus Alarm. Operating Instructions

Model SRMD Setra Remote Monitoring Display

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Inwall 4 Input / 4 Output Module

Model 201 Wiegand Touchpad Reader Installation Guide

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

MINI MCR-SL-R-UI(-SP)

ABB Drives. User s Manual HTL Encoder Interface FEN-31

User Manual THR840DUK Digital Thermostat

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Getting started with

Air damper actuators

CO2 Alarm. Operation. Application

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

is then retained absolutely without interruption.

EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Mounting Instructions. Torque Transducer. A en

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

4-Channel Thermometer / Datalogger

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Transcription:

T38.0.0X.6C-03 CO2 - Transmitter Operating Manual GT10 - CO2-1R GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 Tel.: +49 9402 / 9383-0, Fax: +49 9402 / 9383-33, email: info@greisinger.de

T38.0.0X.6C-03 Page 2 of 7 Content 1. Intended use... 3 2. General advice... 3 3. Safety instructions... 3 4. Disposal notes... 3 5. Installation... 4 5.1 Dimensions... 4 5.2 Elbow-type plug installation instruction... 4 5.3 Assignment of elbow-type plug... 4 6. Operation... 5 6.1 Display functions... 5 6.2 Error an System messages... 5 7. Configuration... 6 7.1 Description of configuration parameter:... 6 8. Specification... 7

T38.0.0X.6C-03 Page 3 of 7 1. Intended use CO2 gas is outweigh than air (rel. density = 1.52). The suggested mounting level is near the floor. Range of application: Air conditioning Ambient air Carbon dioxide in green house etc. 2. General advice Read through this document attentively and make yourself familiar to the operation of the device before you use it. Keep this document in a ready-to-hand way in order to be able to look up in the case of doubt. 3. Safety instructions This device was designed and tested considering the safety regulations for electronic measuring devices. Faultless operation and reliability in operation of the measuring device can only be assured if the General Safety Measures and the devices specific safety regulation mentioned in this user s manual are considered. 1. Faultless operation and reliability in operation of the measuring device can only be assured if the device is used within the climatic conditions specified in the chapter Specifications. 2. By faulty handling of the interface adapter a damage of the device cannot be excluded. Likewise a damage of your attached device is possible. In such case we cannot assume any warranty. The manufacturer will not assume any warranty for damages to other devices resulting by use of the interface adapter. 3. Standard regulations for operation and safety for electrical, light and heavy current equipment have to be observed, with particular attention paid to the national safety regulations. 4. When connecting the device to other devices (e.g. the PC) the interconnection has to be designed most thoroughly, as internal connections in third-party devices (e.g. connection of ground with protective earth) may lead to undesired voltage potentials. 5. The device must be switched off and must be marked against using again, in case of obvious malfunctions of the device which are e.g.: visible damage no pre-scripted working of the device storing the device under inappropriate conditions for longer time When not sure, the device should be sent to the manufacturer for repairing or servicing. 6. Attention: Do not use this product as safety or emergency stopping device or in any other application where failure of the product could result in personal injury or material damage. Failure to comply with these instructions could result in serious injury and material damage. 4. Disposal notes The device must not be disposed in the regular domestic waste. Send the device directly to us (sufficiently stamped), if it should be disposed. We will dispose the device appropriate and environmentally sound.

T38.0.0X.6C-03 Page 4 of 7 5. Installation 5.1 Dimensions 5.2 Elbow-type plug installation instruction To mount the connection cable (3-, or 4-wire depending on type of device) the elbow-type plug screw has to be loosened and the coupling insert has to be removed by means of a screw driver at the position indicated (arrow). Pull out connection cable through fitting and connect to the loose coupling insert as described in the wiring diagram. Replace loose coupling insert onto the pins at the transducer housing and turn cover cap with fitting in the direction desired till it snaps on (4 different starting positions at 90 intervals). Re-tighten the screw at the angle plug. 5.3 Assignment of elbow-type plug 3 3 1 A / V Uv 1 2 V Uv 3-wire-connection (ma or voltage) 4-wire-connection (voltage) 1 = signal + 1 = signal + 3 = supply voltage +Uv 2 = signal (4) = supply voltage -Uv 3 = supply voltage +Uv signal - (4) = supply voltage Uv Note: terminal 2 and 4 are connected in the device. The type current or voltage output is set by works and cannot be changed.

T38.0.0X.6C-03 Page 5 of 7 6. Operation 6.1 Display functions Currently measured values: During normal operation the CO2 display value is displayed in ppm. Min- / Max-value memory: Watch min values (Lo): press shortly once display changes between Lo- und Min-values Watch max values (Hi): press shortly once display changes between Hi- und Max-values Restore current values: press or once again current values are displayed Clear min values: press for 2 seconds Min values are cleared. The display shows shortly CLr (Clear) Clear max values: press for 2 seconds Max values are cleared. The display shows shortly CLr (Clear) After 10 seconds the currently measured values will be displayed again. Min- / Max- Alarm: Whenever the measured value is exceeding or undershooting the alarm-values that have set, the alarmvalue and the measuring value will be displayed alternating. AL.Lo AL.Hi the lower alarm boundary is been reached or is undershot. the upper alarm boundary is been reached or is exceeded. 6.2 Error an System messages Display Description Possible fault cause Remedy Err.1 Measuring range exceeded Wrong signal. Take care for fresh air. Err.7 System fault Error in device. Disconnect from supply and Err.9 Sensor error Sensor defective. reconnect. If error remains return device to manufacturer. Er.11 Calculation not possible 8.8.8.8 Segment test Calculation variable Check temperature. missing or invalid. The transducer performs a display test for 8 seconds after power up. After that it will change to the display of the measuring.

T38.0.0X.6C-03 Page 6 of 7 7. Configuration In the configuration the device parameters can be changed. The jumper has be set, p.r.t. figure right-hand side. To set or remove jumper, the housing cover has to be removed. Ex works the jumper is set. To change parameters press SET (Taste 1) four seconds, than the parameters selection is started with the first parameter (display shows da.lo ). By pressing SET the desired parameter is selected, the editing of the parameter values happens via key (key 3) or (key 2). Pressing SET again (after editing the parameter values) returns to the parameter selection. Pressing SET again after the last parameter finishes the configuration, stores the changes and the instrument returns to the normal mode. 7.1 Description of configuration parameter: a) 'da.lo': Display at zero output (output scaling) Enter the display value at which the output should have 4mA (or 0V). b) 'da.hi': Display at maximum output (output scaling) Enter the value at which the output should have 20mA (or 1 / 10V). c) 'DA.Er': Preferred state of output Display Preferred state of the analog output Annotation Lo In case of failure inactive Output signal = <3,7 ma or 0 V Hi In case of failure active Output signal = >23 ma or >10.5 V (or >1.1 V) d) 'AL.Hi': Upper boundary of alarm At Al.Hi the boundary is set from which max. alarm will be given. Selectable range: AL.Lo... 2001 e) 'AL.Lo': Lower boundary of alarm At Al.Lo the boundary is set from which min. alarm will be given. Selectable range: -1... AL.Hi f) 'A.dEL': Alarm delay The value at A.dEL declares the alarm delay in minutes. If the jumper is removed from the shown contacts, the configuration is inaccessible, values are protected. g) 'OFFS': Offset of CO 2 -measuring The offset of the measuring will be shifted by this value, the input is in ppm. (calculation: see by scale) Selectable range: -200... +200 ppm or off : offset is deactivated (0 = ex works) h) 'SCAL': Scale correction of CO 2 -measuring The scale of the measuring is changed by this value. Selectable range: -10.00...+10.00 or off : scale is deactivated (0 = ex works) The adjusting by offset and scale is intended to be used to compensate deviations of the measuring. It is recommended to keep the scale correction deactivated ( off ). The display value is given by following formula: CO2-display = measured value offset With a scale correction the formula changes: CO2 display = (meas. value - offset) * (1 + scale correction/100) Jumper

T38.0.0X.6C-03 Page 7 of 7 8. Specification Measuring range: standard 0... 2000 ppm CO 2 option: / 5000 0... 5000 ppm CO 2 Accuracy: (at 20 C, 1013 mbar) Display: standard ± 50 ppm ± 2 % of measuring value option: / 5000 ± 50 ppm ± 3 % of measuring value Add. Output signal: ± 0.2 % FS Temperature dependence: typ. 2 ppm CO 2 / C (0-50 C) Response time: t 63 < 180 s Sampling rate: ca. 15 s Output signal: Please refer to type plate, free saleable. Scaling: By entering display values for 4 ma (or 0 V) and 20 ma (or 1 V/ 10 V) output Connection: 4-20 ma (3-wire) Voltage (3- or 4-wire) Auxiliary energy: Uv = 12-30 V DC, max. 600 ma (at 4-20 ma, 0-1 V) (supply voltage) Uv = 18-30 V DC, max. 600 ma (at 0-10 V) or refer to type plate Reverse voltage 50 V permanent protection: Warm up time: < 5 min. (time to reach specification values) Permissible burden: R A < 200 Ohm (at 4-20 ma) Permissible load: R L > 3000 Ohm (at 0-1 V or 0-10 V) Adjusting: via keypress by editing offset and scale Display: 10 mm high, 4-digit LC-display Min-/Max- Value Memory: min and max measured values are stored Ambient conditions of electronics: Nominal temperature: 25 C Operating condition: -10 to 50 C 5 to 95 %RH. (non-condensing) 850-1100 hpa Storage condition: -25 to 60 C 5 to 95 %RH. (non-condensing) 700-1100 hpa Housing: ABS (IP20) Dimensions: 82 x 80 x 55 mm (H x W x D) without elbow-type plug. Mounting: With holes for wall mounting (in housing - accessible after cover has been removed). Mounting distance: 50 x 70 mm, max shaft diameter of mounting screws are 4 mm. Electrical connection: Elbow-type plug (P65), max wire cross section: 1.5 mm², wire/cable diameter from 4.5 to 7 mm. EMC: The devices correspond to the essential protection ratings established in the regulations of the council for the approximation of legislation for the member countries regarding electromagnetic compatibility (2004/108/EG). In accordance with EN61326 +A1 +(appendix A, class B), additional errors: < 1% FS. Note: When connecting long leads adequate measures against voltage surges have to be taken.