Performance prediction of a centrifugal pump working in direct and reverse mode using Computational Fluid Dynamics



Similar documents
FLUID FLOW ANALYSIS OF CENTRIFUGAL FAN BY USING FEM

The Design & Analysis of a Low NPSH Centrifugal Pump Featuring a Radial Inlet and Axial Inducer Using STAR-CCM+

Turbulence Modeling in CFD Simulation of Intake Manifold for a 4 Cylinder Engine

Keywords: CFD, heat turbomachinery, Compound Lean Nozzle, Controlled Flow Nozzle, efficiency.

Compatibility and Accuracy of Mesh Generation in HyperMesh and CFD Simulation with Acusolve for Torque Converter

University Turbine Systems Research 2012 Fellowship Program Final Report. Prepared for: General Electric Company

Using CFD to improve the design of a circulating water channel

Lecture 6 - Boundary Conditions. Applied Computational Fluid Dynamics

Engineering & Expertise Hydraulic modeling. Computational fluid dynamics

GEOMETRIC, THERMODYNAMIC AND CFD ANALYSES OF A REAL SCROLL EXPANDER FOR MICRO ORC APPLICATIONS

Multiphase Flow - Appendices

ME6130 An introduction to CFD 1-1

Relevance of Modern Optimization Methods in Turbo Machinery Applications

Part IV. Conclusions

Pushing the limits. Turbine simulation for next-generation turbochargers

AN EFFECT OF GRID QUALITY ON THE RESULTS OF NUMERICAL SIMULATIONS OF THE FLUID FLOW FIELD IN AN AGITATED VESSEL

3. Prescribe boundary conditions at all boundary Zones:

COMPUTATIONAL ANALYSIS OF CENTRIFUGAL COMPRESSOR WITH GROOVES ON CASING

Experimental and Numerical Investigation of Blades Slots on Rotating Stall Phenomenon in Centrifugal Blower

CFD software overview comparison, limitations and user interfaces

Application of CFD Simulation in the Design of a Parabolic Winglet on NACA 2412

COMPUTATIONAL FLUID DYNAMICS (CFD) ANALYSIS OF INTERMEDIATE PRESSURE STEAM TURBINE

Computational Modeling of Wind Turbines in OpenFOAM

Steady Flow: Laminar and Turbulent in an S-Bend

A. Hyll and V. Horák * Department of Mechanical Engineering, Faculty of Military Technology, University of Defence, Brno, Czech Republic

Rapid Design of an optimized Radial Compressor using CFturbo and ANSYS

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

CFD ANALYSIS OF CONTROLLABLE PITCH PROPELLER USED IN MARINE VEHICLE

How To Model A Horseshoe Vortex

Module 6 Case Studies

ADVANCED TOOL FOR FLUID DYNAMICS- CFD AND ITS APPLICATIONS IN AUTOMOTIVE, AERODYNAMICS AND MACHINE INDUSTRY

OPTIMISE TANK DESIGN USING CFD. Lisa Brown. Parsons Brinckerhoff

Platform Technology for Computational Fluid Dynamics Supporting Design of System Products

NUMERICAL ANALYSIS OF WELLS TURBINE FOR WAVE POWER CONVERSION

Aerodynamic Department Institute of Aviation. Adam Dziubiński CFD group FLUENT

AUTOMOTIVE COMPUTATIONAL FLUID DYNAMICS SIMULATION OF A CAR USING ANSYS

CFD ANALAYSIS OF FLOW THROUGH A CONICAL EXHAUST DIFFUSER

Express Introductory Training in ANSYS Fluent Lecture 1 Introduction to the CFD Methodology

Laminar Flow in a Baffled Stirred Mixer

GT ANALYSIS OF A MICROGASTURBINE FED BY NATURAL GAS AND SYNTHESIS GAS: MGT TEST BENCH AND COMBUSTOR CFD ANALYSIS

Lecture 11 Boundary Layers and Separation. Applied Computational Fluid Dynamics

CFD Analysis of a Centrifugal Pump with Supercritical Carbon Dioxide as a Working Fluid

Chapter 3.5: Fans and Blowers

FAN PROTECTION AGAINST STALLING PHENOMENON

Effect of Pressure Ratio on Film Cooling of Turbine Aerofoil Using CFD

Simulation of Flow Field and Particle Trajectories in Hard Disk Drive Enclosures

PUTTING THE SPIN IN CFD

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

CFturbo Modern turbomachinery design software

Introduction of Duplex Pump HPD71+71 and Short-Stroke Pump HPV

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

CFD MODELLING OF TOP SUBMERGED LANCE GAS INJECTION

A Comparison of Analytical and Finite Element Solutions for Laminar Flow Conditions Near Gaussian Constrictions

Engineering & Expertise Designing Pump Sumps

Flow Physics Analysis of Three-Bucket Helical Savonius Rotor at Twist Angle Using CFD

O.F.Wind Wind Site Assessment Simulation in complex terrain based on OpenFOAM. Darmstadt,

NUMERICAL SIMULATION OF GAS TURBINE BLADE COOLING FOR ENHANCEMENT OF HEAT TRANSFER OF THE BLADE TIP

TWO-DIMENSIONAL FINITE ELEMENT ANALYSIS OF FORCED CONVECTION FLOW AND HEAT TRANSFER IN A LAMINAR CHANNEL FLOW

Keywords: Heat transfer enhancement; staggered arrangement; Triangular Prism, Reynolds Number. 1. Introduction

A Simplified 3d Model Approach in Constructing the Plain Vane Profile of A Radial Type Submersible Pump Impeller

A Parallel Disc Device for studying corrosion under intense flow conditions

Abaqus/CFD Sample Problems. Abaqus 6.10

DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING

GAMBIT Demo Tutorial

Simulation of Fluid-Structure Interactions in Aeronautical Applications

Design and Analysis of Engine Cooling Fan

Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial

NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES

Finite Element Analysis for Acoustic Behavior of a Refrigeration Compressor

FLUID MECHANICS. TUTORIAL No.7 FLUID FORCES. When you have completed this tutorial you should be able to. Solve forces due to pressure difference.

A Swirl Generator Case Study for OpenFOAM

Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchanger

Performance Comparison of a Vertical Axis Wind Turbine using Commercial and Open Source Computational Fluid Dynamics based Codes

Introduction to CFD Analysis

MEL 807 Computational Heat Transfer (2-0-4) Dr. Prabal Talukdar Assistant Professor Department of Mechanical Engineering IIT Delhi

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope

The calculation of train slipstreams using Large-Eddy Simulation techniques

Machine Design II Prof. K.Gopinath & Prof. M.M.Mayuram. Module 2 - GEARS. Lecture 17 DESIGN OF GEARBOX

CFD Analysis of Swept and Leaned Transonic Compressor Rotor

Customer Training Material. Lecture 2. Introduction to. Methodology ANSYS FLUENT. ANSYS, Inc. Proprietary 2010 ANSYS, Inc. All rights reserved.

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

Navier-Stokes Equation Solved in Comsol 4.1. Copyright Bruce A. Finlayson, 2010 See also Introduction to Chemical Engineering Computing, Wiley (2006).

Initial Design and Optimization of Turbomachinery with CFturbo and optislang

Design and testing of a high flow coefficient mixed flow impeller

Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati

Wind effects on roof-mounted solar photovoltaic arrays: CFD and wind-tunnel evaluation

Set up and solve a transient problem using the pressure-based solver and VOF model.

Chapter 8: Flow in Pipes

DESIGN AND FLOW VELOCITY SIMULATION OF DIFFUSER AUGMENTED WIND TURBINE USING CFD

Introduction to CFD Analysis

THERMAL STRATIFICATION IN A HOT WATER TANK ESTABLISHED BY HEAT LOSS FROM THE TANK

CFD Analysis of a butterfly valve in a compressible fluid

A TEST RIG FOR TESTING HIGH PRESSURE CENTRIFUGAL COMPRESSORS MODEL STAGES AT HIGH REYNOLDS NUMBER

Computational Fluid Dynamics Research Projects at Cenaero (2011)

CFD Application on Food Industry; Energy Saving on the Bread Oven

Numerical investigation of aerodynamic action on track vicinity within the electric locomotive operation

Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).

Centrifugal Pump Handbook

Comparative Analysis of Gas Turbine Blades with and without Turbulators

Transcription:

European Association for the Development of Renewable Energies, Environment and Power Quality (EA4EPQ) International Conference on Renewable Energies and Power Quality (ICREPQ 10) Granada (Spain), 23rd to 25th March, 2010 Performance prediction of a centrifugal pump working in direct and reverse mode using Computational Fluid Dynamics R. Barrio 1, J. Fernández 2, J. Parrondo 1 and E. Blanco 1 1 Departamento de Energía E.P.S.I.G., Universidad de Oviedo Campus de Viesques s/n, 33271 Gijón (Spain) Phone: +34 985 18 22 84, Fax: +34 985 18 20 98, E-mail: barrioraul@uniovi.es 2 Departamento de IMEM Escuela de Ingenierías Industriales, Universidad de Extremadura Avda. de Elvas s/n, 06071 Badajoz (Spain) Phone: +34 924 28 96 11, Fax: +34 924 28 96 01, E-mail: ffrancos@unex.es Abstract. The operation of centrifugal pumps as centripetal turbines can be useful to produce cheap energy in rural zones or developing nations. However, the optimum coupling between the flow and the geometry of the machine cannot be kept in reverse working conditions, and hence the flow instabilities are expected to be much higher. This paper presents a numerical investigation on the unsteady flow in a commercial centrifugal pump operating in direct (pump) and reverse (turbine) mode. Numerical simulations were conducted for several flow rates to investigate the properties of the global flow within the machine. The numerical model was additionally used to estimate the radial load on the impeller, as a function of flow rate, for both modes of operation. Key words Centrifugal pump; CFD simulations; reverse running; unsteady flow; radial load. 1. Introduction Centrifugal pumps can extract energy from a flow of water to supply power to a generator [1], thus operating as centripetal turbines. This mode of operation can be advantageous to produce cheap energy in rural zones or developing nations. The geometry of the pumps is usually designed to get an optimum coupling between the impeller and the volute at the so-called nominal flow rate [2]. In this situation, the flow matches suitably the geometry of the machine, and thus the flow instabilities are reduced to a minimum. In contrast, these optimum coupling conditions cannot be kept when the pump operates in reverse mode at the same flow rate. When operating as a centripetal turbine, it is observed that the point of maximum efficiency shifts towards a higher flow rate than that corresponding to direct (pump) mode. Additionally, and due to the shape of the efficiency characteristic (which is quite flat for high flow rates), it is recommended that the operating flow rate in reverse mode will be greater than the design flow rate of the pump [3]. In consequence, the flow instabilities and the radial unbalance generated when working as a centripetal turbine are expected to be much higher. The Computational Fluid Dynamics (or CFD) programs are gaining in importance for the design and analysis of fluid turbomachinery. The numerical analysis usually implies full 3D simulations to account for turbulent effects, secondary flows, and unsteady phenomena. For the particular case of centrifugal pumps, it is known that the unsteady nature of the flow generates an unsteady interaction with the volute that affects the performance of the machine [4]. This interaction brings about pressure pulsations that generate an unsteady load on the mechanical parts [4-6], thus constituting one of the major sources of vibration and hydraulic noise [7]. This paper presents a numerical investigation on the performance of a commercial centrifugal pump operating in direct and reverse mode. The numerical calculations were carried out with the code FLUENT. The dependence of the numerical predictions in regard to grid and time step size was checked first. The model was subsequently validated with experimental data of global performance characteristics and, once validated, it was used to investigate the global flow and also to estimate the radial thrust on the impeller as a function of flow rate. 2. Numerical model The model was developed for a conventional centrifugal pump with volute casing. The impeller has an eye diameter of 52 mm, outer diameter of 200 mm and seven blades of logarithmic profile. The width at the outlet of

the impeller is 0.0169 m and the blade outlet angle is 29 deg. The minimum radial gap between the impeller and volute tongue is 17% of outer radius. The nominal performance values (pump mode) are φ = 0.011 for flow rate and ψ = 0.16 for head. The non-dimensional specific speed is n s = 0.42. Fig. 1 presents a picture of the numerical model showing the surface mesh. The walls of the casing and also the inlet duct are removed in order to show the geometry of the impeller. The mesh is unstructured and constituted by tetrahedral cells in the impeller and volute and by prismatic cells in the inlet and outlet duct. The total number of cells was established in about 8 10 5 after a grid dependence analysis. The maximum cell skew resulted to be 0.85. Fig. 1. Global view of the pump surface mesh. The numerical calculations were carried out with the commercial code FLUENT by the finite volume method. This code was used to solve the full unsteady Reynoldsaveraged Navier-Stokes equations together with the standard k-epsilon model plus standard wall functions to simulate turbulent effects. The boundary conditions imposed in pump mode were a constant total pressure at the inlet and a variable static pressure at the outlet. In turbine mode, a constant total pressure at the inlet and a constant static pressure at the outlet were chosen. These boundary conditions avoid the definition of a fixed velocity profile at the inlet and outlet sections, and thus they allow for some flow rate pulsation, which is a feature of real pumps. Second order discretizations were used for the convection and diffusion terms. The SIMPLE algorithm established the pressure-velocity coupling. The relative motion between the impeller and the stationary zones of the domain was imposed by defining a grid interface at each fluid region. A sliding mesh technique, which is supported in FLUENT, uses an interpolation routine to exchange data of the cells at both sides. The simulations were carried out first using a frozenrotor interface (i.e. for a relative angular position of the impeller). Once steady convergence was achieved, the resulting velocity and pressure fields were used as initial conditions for the unsteady calculations. The time step size used for the calculations was established in 1.65 10-4 seconds after a time dependence analysis, with resulted in a total of 224 time steps per impeller revolution (i.e. a change of 1.6 deg in the impeller position between two consecutive time steps). The number of iterations in each time step was adjusted to reduce the scaled residuals below 10-5. At least 5 impeller revolutions were required to achieve unsteady convergence, in the sense that the flow variables became periodic when considering one full revolution. 3. Experimental contrast The calculations were performed for five flow rates in each mode of operation. The predictions from the numerical model were subsequently validated with experimental data collected at laboratory. The laboratory tests were carried out using a hydraulic rig that permitted the pumping of the water from and to a reservoir of big dimensions. The magnitude of flow rate was obtained with an electromagnetic flow-meter with an estimated precision of ±0.8%. Two piezorresistive pressure transducers installed at the inlet and outlet duct were used to calculate the head with an estimated precision of ±1%. The tests were carried out at a constant speed of 1750±1 rpm. An auxiliary pump, connected in series with the test pump, was used for the reverse running tests to supply the flow rate and head required. This pump was driven by a motor controlled by a frequency converter. The experimental flow-head characteristic in direct (pump) and reverse (turbine) mode of operation and the predictions obtained from the numerical model are shown in Fig. 2. As observed, the general trend of the curves is suitably predicted by the model, showing a negative slope with flow rate for direct mode and a positive slope for reverse mode. It is also seen that the numerical predictions are in very good agreement with the experimental values, showing maximum (relative) errors less than 4%. Head coefficient, ψ 0.6 0.5 0.4 0.3 0.2 0.1 0 0 0.005 0.01 0.015 0.02 0.025 0.03 Flow coefficient, φ Pump (exp.) Turbine (exp.) Pump (num.) Turbine (num.) Fig. 2. Flow-head characteristic in direct and reverse mode. 4. Analysis of global flow Once validated, the numerical model was used to investigate the global flow in the machine for both modes of operation. Fig. 3 presents an instantaneous contour

map of the static pressure at the near-tongue region, obtained at impeller mid-span, for the 60%, 100%, and 130% of pump rated flow. The relative velocity vectors are also included in the figure. It is observed that the static pressure increases continuously along the impeller passageways from the inner to the outer region as energy is transmitted due to the impulse of the blades. The pressure reaches higher values at the lowest flow rate while decreasing with increasing flow rates, as expected for a centrifugal pump (see Fig. 2). A low pressure region is noted near the tongue for the 60% flow rate. This region is located between the tongue and the impeller, as can be seen in the top image. In contrast, the highest flow rate (130% of rated) shows a low pressure region close to the exit duct and, additionally, a high pressure region between tongue and impeller. The flow progresses smoothly through this volute region at nominal flow rate. observed that there is a region located near the blade pressure side (dashed circle) where the flow reverses direction, thus constituting a re-circulating bulk of fluid. This recirculation provokes a pressure drop that changes pressure direction in the last portion of the blade (i.e. there is a higher pressure on the suction side than on the pressure side). In consequence, this blade does not transmit energy to the fluid in its last portion when passing near the tongue. Fig. 4. Instantaneous map of static pressure at the near-tongue region and relative velocity vectors for three test flow rates (reverse mode of operation). Fig. 3. Instantaneous map of static pressure at the near-tongue region and relative velocity vectors for three test flow rates (direct mode of operation). The relative velocity vectors show that there is a good guidance of the flow along the passageways for medium and high flow rates, showing streamlines adhered to the blade walls. At the lowest flow rate, in contrast, it is Fig. 4 presents equivalent results for similar flow rates of those shown in Fig. 3. In the present case, however, the pump operates in reverse mode (centripetal turbine). As noted, the pressure diminishes from the outer to the inner section of the impeller due to the continuous transmission of energy from fluid to blades. The net head across the impeller increases with increasing flow rates, as expected for a centripetal turbine (see characteristics of Fig. 2). While the pressure seems quite uniform at the tongue region for the 60% flow rate, it can be seen that there is a

low pressure region between the impeller and the tongue for the two higher flow rates. The analysis of the relative velocity vectors shows that the guidance of the flow across the passageways is not as adequate as it was previously in pump mode. Thus, it can be noted that the predicted nominal flow rate presents the best guidance among the results shown in Fig. 4 but, nonetheless, a small re-circulating region can be observed near the trailing edge of the blades (pressure side). This region increases in magnitude and it extends further down the inner section of the impeller at 60% flow rate, thus causing the incoming fluid to move closer to the suction side of the blades, as observed in the top image of Fig. 4. At 140% flow rate, the increasing angle of the incoming fluid causes the re-circulating region to move closer to the suction side of the blades, as noted in the bottom image of Fig. 4. This region extends almost to the middle of the passageway length and it shifts the fluid stream towards the pressure side of the blades. 5. Radial load on the impeller The numerical model was used finally to estimate the radial load on the impeller as a function of flow rate. This was done by storing the unsteady flow computations along one blade passage period. The resulting radial load was calculated by means of a full integration of the instantaneous pressure and shear stress distribution on all the impeller surfaces in each of the time steps. Fig. 5 presents the average magnitude of the radial load on the impeller when operating in direct (top) and reverse (bottom) mode for all the test flow rates. As observed, the average load in pump mode shows a minimum magnitude at nominal flow rate while increasing for off-design conditions. Its magnitude is especially high at low flow rates and, in particular, at the 20% flow rate. It is also noted in top of Fig. 5 that the force vector moves towards the fourth quadrant when operating above rated conditions, as expected for a centrifugal pump. Additionally, Fig. 5 shows an average radial load in turbine mode that increases continuously with flow rate. This average load for φ < φ N, however, is not higher than the maximum radial load obtained in pump mode. Thus, it can be concluded that an excessive radial load is not to be expected when the pump operates in reverse mode at moderate flow rates. In contrast, it is seen in Fig. 5 that the load on the impeller increases significantly for reverse operation above rated conditions. Finally, this figure also indicates that the point of application of the force on the impeller is always located at the third quadrant. The previous figure presented the magnitude of the average radial load on the impeller. However, the results shown in Figs. 3 and 4 suggest that the impeller can be also under the influence of an unsteady (or pulsating) radial load. This unsteady load is caused by the sudden change in pressure experienced by the blades when they pass in front of the volute tongue. Fig. 5. Average radial load on the impeller as a function of flow rate in direct (top) and reverse (bottom) mode. The maximum amplitude of the unsteady radial load is presented in Fig. 6 for both modes of operation as a function of flow rate. This amplitude was obtained after subtracting the average value of Fig. 5 from the numerical calculations. As observed, the unsteady load in pump mode follows a similar trend to that previously seen in Fig. 5: it shows a minimum magnitude at nominal flow rate and increasing amplitudes for off-design conditions (especially at the lowest flow rate). It can be also appreciated that the unsteady load can reach a magnitude up to 30% of the average value. The trend of the maximum unsteady load in turbine mode also resembles that of Fig. 5, showing increasing amplitudes with increasing flow rates. However, the unsteady amplitude obtained in this mode of operation for moderate flow rates (i.e. for φ < φ N ) results similar or even lower than that estimated in pump mode. In contrast, it is seen in Fig. 6 that the unsteady amplitude in turbine mode is well above the maximum value predicted

in pump mode for flow rates higher that the rated one. Additionally, it can be appreciated that the maximum unsteady load in reverse mode can reach a magnitude of about 25% of the average value when operating at medium and high flow rates. Head coefficient, ψ 0.012 0.01 0.008 0.006 0.004 0.002 0 pump turbine 0 0.005 0.01 0.015 0.02 0.025 Flow coefficient, φ Fig. 6. Maximum amplitude of the unsteady radial load as a function of flow rate. 6. Conclusions The operation of a centrifugal pump working in direct mode and as a centripetal turbine was investigated using a commercial CFD code. The simulations were carried out for five flow rates in each mode of operation after testing the dependence of the numerical predictions with respect to grid and time step size. The predictions were validated with laboratory tests, which showed a good agreement between the experimental and numerical flowhead characteristic. The numerical model was subsequently used to investigate the global flow in both modes of operation and, additionally, to estimate the radial load on the impeller as a function of flow rate. When operating as a turbine, it was observed that the flow only matched the geometry of the impeller at nominal conditions while developing re-circulating regions of fluid at low and high flow rates. These regions of fluid located either near the pressure side of the blades (flow rates below rated) or near the suction side (high flow rates). The analysis of the flow also revealed the presence of a low pressure region located between the impeller and the tongue. The predictions of the radial load showed a minimum radial thrust near design conditions in pump mode and an increasing magnitude with flow rate in reverse mode of operation. The magnitude of the total radial load (steady and unsteady components) resulted lower than the maximum total load in pump mode for operating below turbine rated conditions. In contrast, the total thrust on the impeller was found to increase well above this maximum load for flow rates above turbine nominal flow rate. Thus, and considering the usual operation range in centripetal turbines, it can be concluded that the mechanical design of the machine and of the shaft bearings must be carefully undertaken if a usual operation in reverse mode is to be expected. Acknowledgement The authors gratefully acknowledge the financial support of the Ministerio de Educación y Ciencia (Spain) under Project DPI2009-14455. References [1] C.P. Kittredge, Centrifugal pumps used as hydraulic turbines, J. Eng. for Power, 1961, series A, pp. 74-77. [2] B. Neumann, The interaction between geometry and performance of a centrifugal pump, Mechanical Engineering Publications Limited, London (1996). [3] J. Fernández, E. Blanco, J. Parrondo, M.T. Stickland, and T.J. Scalon, Performance of a centrifugal pump running in inverse mode, J. Power and Energy, 2004, 218(4), pp. 265-271. [4] K. Majidi, Numerical Study of Unsteady Flow in a Centrifugal Pump, J. Turbomach., 2005, 127(2), pp. 363-371. [5] R. Byskov, C.B. Jacobsen, N. Pedersen, Flow in a Centrifugal Pump Impeller at Design and Off-Design Conditions Part II: Large Eddy Simulations, J. Fluids Eng., 2003, 125 (1), pp. 73-83. [6] M. Zhang and H. Tsukamoto, Unsteady Hydrodynamic Forces due to Rotor-Stator Interaction on a Diffuser Pump With Identical Number of Vanes on the Impeller and Diffuser, J. Fluids Eng., 2005, 127(4), pp. 743-751. [7] R. Dong, S. Chu, J. Katz, Effect of Modification to Tongue and Impeller Geometry on Unsteady Flow, Pressure Fluctuations and Noise in a Centrifugal Pump, J. Turbomach., 1997, 119 (3), pp. 506-515.