EuroSynth FracRak Comparisons



Similar documents
AU-110 racking guide NBXPN: 023

ASKING FOR ASSISTANCE

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

PROXIMITY CARD READERS C-10, C-20, C60, C70

Customized Server Cabinets

About the HotWire Slot Standalone Shelf

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

SERVER ROOM CABINET INSTALLATION CONCEPTS

DIGITUS Network & Server Cabinets. UNIQUE Series

Rack Installation Instructions

SYSTEM 45. C R H Electronics Design

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

TrueAlarm Fire Alarm Systems

Relay mounting systems

Cabinets 101: Configuring A Network Or Server Cabinet

Vision Engravers and Routers PRE-Installation Guide Vision Engraving & Routing Systems

EGSTON Standard E2xFxWx 12W

Rack Systems Solutions

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

Allen-Bradley HP AC Line Filter Kit

HP UPS R1500 Generation 3

DELTA3-1. Delta 3 Data Centre Rack Solution

SD. Flat roof. Rack Mounting. Installation instructions (2010/11) AU

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

New XUY roller sensors

Altistart. 01 Soft Start The starting solution. For single-phase and three-phase asynchronous motors 3 to 85 Amps 1/4 to 75 HP (0.

Description. Dimensions. Features. precision works better

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

19" Open Rack for Network and Cabling Management

InstaPATCH ZERO Solution Guide

Distributing Power to Blade Servers

DCF Optimized Rack System

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Cooktop Low-Profile Ventilation Hoods

SYSTEM 4C. C R H Electronics Design

APPLICATION NOTE. Basler racer Migration Guide. Mechanics. Flexible Mount Concept. Housing

16/32 Channel 1U Rack Mount CCTV Power Supply

PD-300 SERIES 2 X 20 LCD CUSTOMER DISPLAY Rev. C0

BLADE S-MAX Cabinet for Blade Server

Installation. Basic Rack Power Distribution Unit for Blade Servers

Contents. Document information

Knürr Smaract. Knürr Smaract. CompactRack

BROWACOM PRODUCTS. Our web-pages can be found from:

omega.com ΩOMEGA RS232 Multi-Drop FMA1600-MDB Multi-Drop Box

FIELDPOINT BUS EXTENDER CABLE

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

Power distribution in data centres

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

PCIeBPMC (PCI/PCI-X Bus Compatible) Bridge based PCIe and PMC Compatible Adapter Carrier Front View shown with 1 installed fans model # PCIeBPMC-FAN2

Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc.

Version 3.0 Technical Brief

Edition Perfect combination 9 Power supplies Electronic P Edition kaging www clear order..biz information in the catalogue

ZC-24DO CANopen I/O Module: 24 Digital Outputs

I. Introduction 02. Specifications 02 Accessories 02 Features 03. II. Installation Instructions 06

ATX Specification. Version 2.2

Experiment 5. Strain Gage Measurements

Installation Instructions

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

MAGNETIC CARD READER DESIGN KIT TECHNICAL SPECIFICATION

SOLAR MODULES SOLARFLEX Polska Grupa Inwestycje Ekologiczne Sp. z o.o. PRODUCTS LINE of SOLARFLEX Price list

MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION

Supporting Cisco Switches In Hot Aisle/Cold Aisle Data Centers

To reduce the risk of electrical shocks, fire, and related hazards:

ADC Structured Cabling Solutions

PS 155 WIRELESS INTERCOM USER MANUAL

Server Chassis and Triplet Hardware v1.0

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

How To Mount An Ecosa Series Solar Panel

SMEMA Surface Mount Equtpment Manufacturers Association

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

Horizontal Mini Blinds Installation Guide

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

Amplifier: AMP Feature Summary

Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications

Serial ATA to Serial ATA

AIR CONDITIONING SYSTEMS

MPR-Systems. Mini Power Racks 1200 W W

Home Cabling Installation Guide

Installation GUIDE IMPORTANT: KEEP THIS MANUAL AND THE PRODUCT ID LABEL IN A SAFE PLACE

PS6500 Storage Arrays Rack Mount Instructions

ZONIT POWER DISTRIBUTION SYSTEM ORDER CATALOG

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

DVI DA2 and DVI DA 4 User Guide

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

Installing Cisco TelePresence MX200 G2 - Wheel Base

Installation Instructions For Slider Casement Air Conditioners

Secure your IT equipment with confidence... secure with NetClosure

T1 Backhaul Connectivity Solution All Products :: Application Note

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Core-NC210: i5 NUC Industrial Computer

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Transcription:

A summation of the major differences between the EuroSynth and FracRak systems. This documents attempts to cover the major differences between these 2 popular `mini modular systems and the pros and cons of building a unit that incorporates modules from both systems. Revision 1.01 February 27 th 2015. 1 of 6

Mechanical Differences Although both systems are designed to be compliant with the industry standard 3U rack height for Euro-Rack systems, there are some differences I the actual implementation between them. While FracRak front panels utilise the full 3U height of the Euro-Rack, Euro-Synth front panels incorporate a protective lip in to the mounting rails which affords the front panels top and bottom edges from being damaged. As a result EuroSynth front panels are approximately 4mm shorter than FracRak panels. This also leads to the vertical separation of the mounting holes being different. Consequently, EuroSynth and FracRac front panels are not interchangeable In this picture of a FracRak you can see the 2 mounting rails at the top and bottom of the case. The FracRak panel extends fully over these thus achieving the full 3U panel height. In this picture of a EuroSynth you can see that the panel is bordered top and bottom by a small lip. This lip is actually part of the mounting rails and provides a `frame in which the panel is mounted As a result it is generally recommended that a mixed modular system employ multiple racks with each rack being assigned to one family. This results in a much neater solution and requires no mechanical modifications to any modules that are installed. 2 of 6

Electrical Differences In general, EuroSynth systems use +/-12VDC power rails while FracRak uses +/-15VDC. In many cases you can mix modules on the different power rails. The main points to be aware of are:- 12V modules on 15V power rails 1. Any onboard regulators in the module may run slightly warmer. This should not normally be a problem as most module designs will ensure adequate cooling is provided for the regulators over a reasonably wide range of input voltages. 2. Some modules derive internal reference voltages/currents from the power rails. Increasing the power rails will also result in the reference signals being increased and this could affect the overall operation of the module. It may be necessary to re-calibrate the module or even modify the relevant components 3. If a module uses components that are rated to a maximum of 12V then their operation at higher voltages could cause a failure of that component. 15V modules on 12V power rails 1. Any onboard regulators will need to be checked to ensure that they are receiving adequate input voltage for the regulator to maintain correct and proper regulation. This should only really affect regulators providing outputs in excess of 9VDC. 2. Some modules derive internal reference voltages/currents from the power rails. Decreasing the power rails will also result in the reference signals being decreased and this could affect the overall operation of the module. It may be necessary to re-calibrate the module or even modify the relevant components. As mentioned in the Mechanical Differences section, it is generally recommended to use separate racks for the different systems and this would also apply to the power supplies. Although this does increase the cost of the overall system, it does ensure that all modules remain completely unmodified and simplifies the management of modules when moving them around as you do not need to consider if the module is suitable and/or has been modified. The range of control/signal voltages required both as inputs to and outputs from a module tend to vary slightly within the different systems. Some systems may require, say, a 0V to +5V control voltage to achieve full range control of a function whereas other systems may require 0V to +10V. In the case where 15V modules are run on 12V power rails, the maximum achievable output range may be attenuated slightly by the reduced power rails. It will depend upon the modules being used, what they are connected to and what adjustments are provided that will determine if this will be a problem. As many large systems utilise modules from 2 or more systems, they have, usually, already addressed the need to match signal levels and so this problem is usually controllable. You should also check with the relevant module suppliers to determine if modifying them affects any warranty you may have on the module. One final point here is that the different systems also tend to use different power connectors and cables. Again, this is easily addressed with system specific racks in a system. If you intend, however, to opt for mixed systems within a rack then you will also need to consider providing custom power-patch cables that will allow the different modules to be connected to common power supplies. It is also worth mentioning that the PAiA series of modules are designed for +/18V power rails as they have onboard regulators that generate the required +/-12V. This does mean that (a) they will work quite happily in FracRak systems utilising +/-15V rails as the regulators only need a round 2.5V headroom for guaranteed regulation. Also, by bypassing the onboard regulators, the modules can be run directly from a system running on +/-12V rails. (Thanks to John McMillan for this tippet). 3 of 6

Interfacing Differences In addition to the mechanical and electrical differences already discussed, there is the question of the connections between the various systems. The smaller modules tend to use either 3.5mm (1/8 ) jacks or 4mm banana plugs. Patch cables can be made that allow signals from one system to be patched in to a different system but this does result in a reasonable increase in the number of cables that need to be carried. This problem increases further when larger module formats are added which tend to use 6.35mm (1/4 ) jacks. Depending upon the type of patch cable used and the configuration of the module, most 3.5mm patch leads use a screened cable allowing the ground conenction on one system to be automatically conencted to the ground of another system when inter-patched (*). 4mm banana plugs only support a single wire, so when patching between multiple systems it is ncessary to provide a common ground connection between the systems. The use of screened or non-screened patch leads is generally of no importance when patching within a single system as, assuming compliant module and power supply design has been applied, a ground reference is alerady established within the system Connecting multiple grounded patch leads between 2 or more systems may lead to ground-loops 4 of 6

Mechanical Details Both EuroSynth and FracRak utilize industry standard 19 racks as the basic frames for their systems. The structure of the mounting rails differs slightly between these systems with the FracRak system utilizing a flatfronted mounting rail that allows the front panel to extend to the upper and lower limits of the rack. The drawing to the right is from Blacet and details the basic dimensions for a typical FracRak module. The drawing below is from Doepfer and details the basic dimensions for a EuroSynth module FracRak module front panels are all 3U high (1U = 1.75 inch = 1.75" = 44.45mm, 3U = 133.4 mm) while EuroSynth module front panels are 128.5 mm. The width of the front panels is measured in HP (HP = horizontal pitch, 1 HP = 5.08 mm or 1/5 inch or 1/5"). The actual width of a front panel is usually a few tenths of a mm less than the calculated value to allow some tolerance to assemble the panels side-by-side. The original rack system has a usable width of 84 HP (= 426.4 mm), however there is now a trend to go for wider systems allowing for more flexibilty in module layout and achieving, in general, a lower cost per HP for a system. Currently widths of 104HP, 126HP and 168HP are supported but in practise any desired width is achievable. EuroSynth modules can come in any multiple of 1HP widths whereas FracRak modules tend to use just a few standard fixed widths. 5 of 6

EuroSynth EuroRack We have used the term EuroSynth when referring to EuroRack modules because although EuroSynth modules are mechanically compliant with the EuroRack standard, EuroSynth modules use a 3mm fixing screw while EuroRack uses 2.5mm (as does FracRak). 6 of 6