HIGH PRESSURE FEEDWATER HEATER REPAIR



Similar documents
Heat Exchanger Thin Film Foul Release Applications Corrosion Resistant Protective Coatings Grit Blast Surface Prep of Tubular Equipment

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

Oil and Gas Pipeline Design, Maintenance and Repair

CURRENT EXPERIENCE IN TYPICAL PROBLEMS AND FAILURES WITH BOILER PIPING COMPONENTS AND SUPPORTS

TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE:

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

TITANIUM FABRICATION CORP.

TUBE-TO-TUBESHEET JOINTS: THE MANY CHOICES ABSTRACT KEYWORDS. Seal welding, tube-to-tubesheet welds, heat exchanger, mock-up, tube expansion

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

Seamless stainless tubes for hydraulic and instrumentation systems

Selecting TEMA Type Heat Exchangers

Steam System Best Practices Condensate System Piping

Portable leak detection instrument improves heat rate at electric power plant. By Terrence O'Hanlon, CMRP Reliabilityweb.com

North American Stainless

C. starting positive displacement pumps with the discharge valve closed.

World Class Water Chemistry By Accident? BRO Chemistry Session 8/5/2014

FIELD PERFORMANCE OF

Tube Damage Mechanism and Analysis in Feed Water Heaters

QUADRANT SR- Thermal Oxidizer Process Design & Environmental Control Benefits for the Sand Coating Industries

NFPA31FuelOilPiping 1 Revised

JIS G3472 Electric Resistance Welded Carbon Steel Tubes for Automobile Structural Purposes

This will also provide you with the knowledge to insure long life for your Investment

Specification for Rotary Drill Stem Elements

Condition Assessment Services. Put our team of specialists to work for you

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

Trouble shooting guide

A World Class Manufacturer of Induction Bends

ATI 2205 ATI Technical Data Sheet. Duplex Stainless Steel GENERAL PROPERTIES. (UNS S31803 and S32205)

Standard Recommendations for Pressure Part Inspection During a Boiler Life Extension Program

I. STEAM GENERATION, BOILER TYPES

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

James M. Pleasants Company

Float and Thermostatic Traps Series H, C and X

DOCUMENTATION FOR QUALIFICATION SYSTEM

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

GEOTHERMAL POWER PLANTS IN JAPAN ADOPTING RECENT TECHNOLOGIES

Backup Fuel Oil System Decommissioning & Restoration Plan

TYPE E Main Valve Sizes 3 /8 through 12

Munchkin Heat Exchanger Maintenance

DIESEL EFFECT PROBLEM SOLVING DURING INJECTION MOULDING

System Assessment Capabilities for Fossil Fuel Power Stations

Crevice Corrosion on Stainless Steel Propeller Shafts

Application Guide. Compensators Hose Assemblies Expansion Joints FLEX-WELD INCORPORATED FLEX-WELD.COM. Manufactured By:

Field Welding Inspection Guide

DEGASSED CATION CONDUCTIVITY MEASUREMENT

Petrochemical Refinery Maintenance. Complete Maintenance Solutions

49 CFR 192 Transportation of Natural and Other Gas By Pipeline: Minimum Federal Safety Standards

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

Trouble Shooting. Pump

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

The soot and scale problems

VACUUM REFRIGERATION SYSTEMS

GENERAL RUBBER LINING PRINCIPLES

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD

The Suitability of CRA Lined Pipes for Flowlines Susceptible to Lateral Buckling SUT Global Pipeline Buckling Symposium, February 2011

Weld Cracking. An Excerpt from The Fabricators' and Erectors' Guide to Welded Steel Construction. The James F. Lincoln Arc Welding Foundation

Tubing Data. Contents. Tubing Selection. Tubing Handling. Tubing Material. Tubing Outside Diameter Hardness. Tubing Wall Thickness

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

GE Oil & Gas. Air cooled heat exchangers Robust and reliable for all loads and applications

DESIGN STANDARDS SECTION

10 Nuclear Power Reactors Figure 10.1

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

Boiler & Pressure Vessel Inspection discrepancies and failures

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

EJECTOR AIR REMOVAL SYSTEMS ENGINEERING DATA BULLETIN # PVS ARS PAGE 1 OF 5

Defining Quality. Building Comfort. Heating and Cooling Coils

ENGINE COOLING SYSTEM

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

5.2. Vaporizers - Types and Usage

3D Conjugate Heat Transfer Analysis of the Next Generation Inner Reflector Plug for the Spallation Neutron Source

Evaluate, Clean, and Tune Guidance

Boiling Water Reactor Systems

Wall Thinning Trend Analyses for Secondary Side Piping of Korean NPPs

ASME Packaged Indirect Fired Water Heater

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

Turbine Modernization Projects at Susquehanna and Salem Nuclear Plants Maximize Performance at Current and Future Uprate Steam Conditions

How To Clean Up A Reactor Water Cleanup

Heating Water by Direct Steam Injection

Peach Bottom Atomic Power Station, Units 2 and 3 Renewed Facility Operating License Nos. DPR-44 and DPR-56 NRC Docket Nos.

Measuring the Condition of Prestressed Concrete Cylinder Pipe

POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Equipment Performance Monitoring

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Commercial Semi-Instantaneous Water Heaters

Ultrasonic Reference Blocks

Hose Clamps & Fittings

Contents and Nomenclature

Specification for Pipe Coating Repairs Offshore

RISK BASED INSPECTION (RBI)

Transcription:

HIGH PRESSURE FEEDWATER HEATER REPAIR B. W. Helton II Tennessee Valley Authority 1101 Market Street Chattanooga, Tennessee 37402 Peter Tallman CTI Industries Inc. 200 Benton Street Stratford, Connecticut 06615 Prepared for presentation at the EPRI Feedwater Heater Technology Symposium October 9-11, 2001 Birmingham, Alabama

HIGH PRESSURE FEEDWATER HEATER REPAIR B. W. Helton II Tennessee Valley Authority 1101 Market Street Chattanooga, Tennessee 37402 Peter Tallman CTI Industries Inc. 200 Benton Street Stratford, Connecticut 06615 Abstract In late 1988 and early 1989, two of the four high pressure feedwater heaters at each of the three generating units at the Tennessee Valley Authority's (TVA) Thomas H. Allen Fossil Plant were replaced. In the Fall of 1997, after 8 1/2 years of service, a significant number of tubes failed suddenly in the two Allen unit 3 replacement heaters. Within a 14 month period, one of the unit 3 replacement heaters had 97 tube failures and the other had 171 failures. The mode of these tube failures was determined to be stress corrosion cracking (SCC) initiated at a tube roll transition located within the tubesheet. In order to prevent continued progression of tubing damage and to restore failed tubes to service, TVA employed CTI Industries to install stainless steel inserts in the inlet and outlet ends of each tube in the affected heaters. This paper discusses the failures, investigative techniques, probable root causes, and corrective measures evaluated and implemented to extend the service life of high pressure feedwater heaters at TVA's Allen Fossil Plant.

Introduction TVA is a federally owned and operated electric power company serving the Tennessee Valley. TVA s total net electric power generating capability is approximately 28,000 megawatts from a combination of fossil-fired, nuclear, hydroelectric, combustion turbine, and pumped storage plants. TVA's Allen Fossil Plant, located in Memphis Tennessee, was designed and constructed by Burns and Row Inc. for Memphis Light Gas and Water. The plant was placed into service in 1956, was purchased by TVA in 1984 and is an integral part of the TVA system. The Allen plant has three identical subcritical generating units. Each unit has a B&W coal fired wet bottom steam generator which produces 2,000,000 pounds of steam per hour to drive a Westinghouse tandem compound triple exhaust 'turbogenerator set at a rated capacity of 250,000 kw. Figure 1 depicts the steam/water cycle. The feedwater heating system for the Allen units includes a single string of three low pressure heaters, one deareating heater, and four high pressure heaters. The heaters are numbered #1 through #8. Heaters #1 through #3 are low pressure, heater #4 is a deaerator, and #5 through #8 are high pressure heaters with # 8 being the highest pressure. The system design includes capability to isolate each high pressure heater individually from extraction steam and to bypass feedwater around each heater individually. However, as with many facilities of this vintage, good isolation is not always achievable and depends on the condition of isolation equipment at any given time. The original #5 and #6 heaters, manufactured by the American Locomotive Co., were replaced on all 3 units between December 1988 and June1989, with replacement heaters designed and manufactured by Southwestern Engineering Company. The replacement heaters are closed, horizontal U tube, three zone, (desuperheating, condensing, and subcooling) heaters with full access channels. The U-tubes are SB-168-400 drawn and stress relieved Monel, 5/8" OD x.060" wall tubing. The tubesheets are 10" thick carbon steel with Monel overlay machined to 1/4" thickness. The tubes are roller expanded inside the tubesheets and welded to the Monel overlay. Table 1 is a technical specification sheet for feedwater heaters #5 and #6. Chronology of Tube Failures and Diagnostic Efforts In October 1997 plant maintenance personnel plugged 28 leaking tubes in the Allen unit 3 feedwater heater #6. Prior to that date and since the initial operation of the replacement heaters in March 1989, there had been a total of 5 tube failures.

During a planned unit 3 maintenance outage in November 1997, pressure testing, eddy current examination, and borescope inspections revealed that tubes in both the #5 and #6 feedwater heaters had failed and were leaking at locations inside the tube sheets. The leaking tubes appeared to be randomly distributed throughout the tube bundle with inlet and outlet tube ends affected. In each of the 12 failed tubes in the #5 heater and in 3 tubes that had been plugged the month before in the #6 heater, the leaks were located with a borescope. This was accomplished by pressurizing the heater (to approximately 100 psig), applying soap solution to the inside of the tubes, and observing the bubble formations with the borescope. A special eddy current probe, designed to detect circumferential cracks and to minimize the response to conditions that are radially symmetrical, was used to inspect the tubes. Since no calibration standards were available for the conditions encountered, an eddy current pattern recognition scheme was developed based on comparisons between tubes where leaks could be observed with the borescope and others believed not to be damaged. By use of this method the leaks in all 12 failed tubes in the #5 heater and in the three unplugged failed tubes in the #6 heater were detected. Similar damage that had not progressed through wall in other tubes in both heaters was also detected using the procedure. The special probes were obtained from the EPRI NDE Center in Charlotte, North Carolina and are described briefly in figure 2. A number of Inlet and outlet tube ends from various locations within the tube bundle were inspected in both the #5 and # 6 heaters using the developed eddy current procedure. Eight percent of the nonleaking tube ends inspected in the #5 heater and five percent of those in the #6 heater exhibited eddy current signals characteristic of the damage observed in the tubes which were known to have failed. All damage detected was at precisely the same location in each tube. Upon completion of the inspections a failed section of one of the #5 heater tubes was removed for laboratory examination. Microscopic examination of the sample revealed the damage to be SCC at a tube roll transition. As indicated in figures 3 and 4, tube failure rates in both the #5 and #6 heaters increased during the months following the initial failures. Figures 3 and 4 are tube sheet plots showing the location of failed tubes in each heater. Description of Failures, Failure Mechanisms and Root Causes All the tube damage identified in the Allen unit 3 heaters #5 and #6 was located within the tube sheet at precisely 8 7 / 8 inches from the clad face of the tubesheet. Figure 7 is a sketch of the tube and tube sheet cross section depicting the location of failures and cracks. Microscopic examination of the retrieved failed section of tube revealed the damage to be longitudinal SCC at a tube roll transition. Borescope examinations performed after the initial discovery of the problem revealed that the failed tubes each had from one to three longitudinal cracks, all located precisely at the roll transition 8 7 / 8 inches from the clad face of the tubesheet.

SCC can occur when a susceptible material with high tinsel stress levels is subjected to a corrosive chemical environment. One of the specific primary causes of the Allen feedwater heater tube wall SCC is believed to be high residual stress levels at the channel end transitions of the tube rolls located at the shell side face of the tubesheets. The tube rolls in these heaters are unique to those in other high pressure heaters in the TVA Fossil System. Most TVA heater tubes are step rolled inside the tubesheets with the first roll starting near the feedwater side face of the tubesheet. As depicted by figure 7, the tube ends in the Allen #5 and #6 heaters have two distinct rolled areas separated by approximately 6 inches of tubing that is not rolled. It appears that when the smaller of the two rolls in each tube end was made the tubing may have been overly stressed by the operator end of the expander rolls. Most roller expanders available for installing tubes inside thick tubesheets are designed to step roll the tubes. This means that the operator or back end of the expander rolls are not typically tapered as much as the front ends. When tubes are step rolled care must be taken to overlap each roll so the operator ends of the tube expander rolls don t leave the tube wall deform and with high levels of residual stress. Overlapping successive rolls inside thick tubesheets ensures that the back ends of the expander rolls do not stress portions of the tube which have already been expanded by the previous roll step. Another primary cause of any SCC problem, given a susceptible material and sufficient tinsel stresses, is a conducive chemical environment. Inspection of the heater venting systems and a review of venting and feedwater treatment practices at the Allen plant provided no specific indication that heater shell side or waterside chemistry would have contributed to the problem. Ammonia, that can cause SCC in Monel, is present in the feedwater, but chemistry records indicate no unusually high concentrations. There was no evidence that concentrations of chlorides or other chemical species conducive to SCC of Monel had been introduced. Evaluation of Options for Restoring Heater Reliability and Function If the root causes of the tube failures could be eliminated or controlled and the failed and damaged tubes recovered or repaired, heater reliability and function could be restored. Elimination or reduction of the contributing tensile stresses would require that the tube ends be stress relieved. Options considered where: Use of high temperature steam from one of the Allen generating units Application of heat from electric resistance heating devices similar to those used for weld pre and post heat treatment Peening the tube IDs with grit or beads Re-expansion of the tubes at the tube roll transition where the SCC was occurring inside the tubesheets,

After careful consideration it was concluded that none of these methods would eliminate problems resulting from small undetected cracks in the tube. For this reason stress relieving was not considered a viable option for mitigation of the cracking problem. Elimination of the corrosive chemical environment was also not considered an endeavor likely to have an appreciable affect on the tube failures. Even though water chemistry was properly controlled, tubes continued to fail over a considerable period of time. It was thought likely that whatever constituents were causing the damage were concentrated inside many already developed cracks from which it would not be possible to effectively remove them. Damage Repair and Prevention While reasonable measures would be taken to prevent future detrimental chemical contamination of the feedwater heaters, none of the failure causes could be sufficiently eliminated or reduced to prevent continuing tube failures. Neither could the elimination of causes restore function to failed tubes or prevent premature failure of already badly damaged tubes. A number of alternatives for prevention of additional tube failures and restoration of function to failed tubes were evaluated. These included weld repair of failed and cracked tubes and installation of tube inserts by hydraulic or explosive expansion. Weld repair of failed and cracked tubes was investigated as an option. It was learned that tooling with which weld repairs could be made inside tubing with inside diameters of only 0.5 inch was not commercially available. While it appeared possible to have such tooling developed it clearly would not be a cost effective option because of the considerable expense for such development. Installation of tube inserts by hydraulic expansion was also evaluated as an option for restoration of tube function and reliability. This restoration technique was developed in the mid 1970 s to restore service life to heat exchanger tubes with various types of damage near the tube ends. Inlet end erosion and SCC are damage mechanisms which can be countered with this technique as are localized pitting, crevice corrosion, impingement and grooving which might occur near tube ends. The technique makes use of thin-walled metallic inserts, fabricated with a flair at one end and I.D. chamfer at the other end, which are expanded into the existing tube ends. Such inserts are also variously referred to as I.D. tube shields, or sleeves.

Figure 8 is a cross section sketch of a tube insert and figure 9 is a cross section sketch of an installed insert, tube, and tubesheet. The intent of insert installation in the Allen heaters would be to bridge degraded sections of the original tubes with a material which would preserve or restore the integrity of the tubes and tube to tube sheet joints. It would also be necessary that the insert installation not lead to other problems such as SCC of the original tube at or near the insert. TVA had two primary concerns regarding the installation of inserts in heat exchanger tubing. One was that the expansion of inserts into the existing tubing might induce additional excessive stresses and thereby promote further SCC. The other was that leak paths might develop between the OD of the inserts and the I.D. s of the existing tubing and that very small leaks through these paths might grow over time to unacceptable rates. Review of the application of this technique for rehabilitating feedwater heaters at other utilities indicated that function and reliability of the Allen feedwater heater tubes could be restored by the hydraulic expansion of inserts. In addition to having been demonstrated to be a successful option, installation of tube inserts by hydraulic expansion was also determined to be the most cost effective. Explosively expanded inserts was evaluated and also considered to be a viable option for recovering tube function and reliability. This method is considerably more expensive than hydraulic expansion and for the Allen feedwater heaters it was not considered to provided any significant advantage over hydraulic expansion. For TVA the decisive difference between the two methods was cost. According to budgetary estimates received, the explosive expansion method would have been approximately five (5) times the cost of hydraulic method. Implementation of solution Upon evaluation of the various alternatives considered it was TVA s decision to have metallic tube inserts fabricated and install by hydraulic expansion in the Allen unit 3 feedwater heater #5 & #6 tube ends. CTI Industries was contracted to fabricate and install the inserts and the installation was performed in September 1999, during a scheduled maintenance outage. The inserts were fabricated from 304 Stainless Steel seamless tubing, 0.485 inch OD, 0.020 inch wall thickness. Figures 9 depivts the as installed insert, tube, and tubesheet. In preparation for installation the heaters were opened and checked for additional tube failures which were documented. All the tube plugs were removed from previously failed tubes. To ensure reasonable cleanliness at the tube ID and insert interface, TVA cleaned each tube end to a depth of two feet using a portable pressure washer and blew each tube dry with station service air. At that point CTI Industries arrived on site to install the inserts. CTI wire brushed each tube end I.D., blew each end clear with compressed air, took ID measurements to determine expansion requirements, and placed inserts into each tube end.

The inserts were expanded with a hydroswage mandrel. The mandrel was coupled to a strain volume control hydroswage pump which was preset to achieve full length expansion of the insert. A hybrid expansion was then accomplished by roller expanding each insert at two areas within the tubesheet to torque controlled settings and also at the shell side end by mechanical settings. Finally the insert ends were flared to conform to the contour of the flared end of each tube. Upon completion of the installation the heater shells were pressurized to 100 psig and a leak check was made at the tube sheets using a soap solution. Conclusion During a short planned maintenance outage in March of 2000, the Allen unit 3 high pressure heater #5 was opened because of suspected tube leaks. Upon pressurizing the heater, to 100 psig, eight (8) tubes were found to be leaking. Seven of the leaks were determined to be from locations at the U bends. One tube was observed to have a very small leak from the shell side end of one of the inserts. This leak would not have been detected had the heater not been inspected because of the significant leaks found in the tubes which had failed at the U bends. By the installation of inserts TVA was successful in recovering 310 tubes in the #5 and #6 high pressure heaters at Allen unit 3. After the SCC problems were initially encountered with these two heaters, the same problem began to plague the #5 and #6 heaters at Allen unit 1. During a maintenance outage in March of 2000, CTI Industries installed inserts in all the tube ends of the unit 1 heater #6. Current plans are to have CTI install inserts in the #5 heater on that unit at the next available opportunity.

287,536 kw 1,230,584 # COND H2 COOLER SECT 1 OIL COOLER AIR EJECTOR 1,232,454 # CLAND CONDENSER ALLEN FOSSIL PLANT, UNITS 1-3 HEAT BALANCE 1,015,000 # 90,216 # SECT 2 HTR 1 7.60 P 1,322,580 # 1,388,771 45,081 # 65,260 # HTR 2 HTR 3 15.51 P 37.3 P SECT 3 SECT 4 CONDENSATE PUMP 48,065 # 2,000,000 # STEAM CHEST STEAM 1,572,872 # GENERATOR 221,093 # HTR 8 HTR 7 HTR 6 HTR 5 479.8 F 397.9 F 342.7 F B.F. PUMP 1,572,872 # HTR 4 854.3 F 67.9 P 163,245 # 687.2 F 82,714 # 833.3 F 1112 P 565.3 P 228.0 P 124.4 P 487.3 F 405.4 F 350.2 F 221,093 # 384,338 # 467,052 # 51,962 # 680.2 F 306.7 F 314.2 F 519,014 # 2,000,000 # Figure 1.

TVA Allen Fossil Plant - Unit 3 High Pressure Feedwater Heater Specifications Feedwater Heaters No. 5 No. 6 Manufacturer : Southwestern Engineering Co. Type : Horizontal U-Tubes Design Operating Steam Inlet Temperature : F 680 833 Design Operating Drain Inlet Temperature : F 350 405 Design Operating Feedwater Inlet Temperature : F 307 343 Design Operating Drain Outlet Temperature : F 314 350 Design Operating Feedwater Outlet Temperature : F 343 398 Design Operating Shell Pressure : psia 122 228 Design Temperature, Shell Side Skirt : F 750 890 Design Temperature, Shell : F 400 450 Design Temperature, Tube Side : F 400 450 Design Shell Pressure : psig 150 300 Test Shell Pressure : psig 225 450 Design Tube Side Pressure : psig 3,700 Test Tube Side Pressure : psig 5,550 Design Operating Tube Side Velocity : ft. / sec 8.25 7.67 Number of "U" tubes : 765 824 Tube Material : Monel SB-163-400 DSR Tube OD : in. 0.625 Average Tube Wall : in. 0.060 Average Tube Wall - Three Inner Rows in. 0.063 0.064 Tube pitch : in. 0.8438 Tube straight Length : in. 391 450 Tube sheet material : SA-350-LF2 Tube sheet thickness : in. 10 1/4 Tube to Tube Sheet Joint : Welded & Rolled Tube Sheet Overlay : Monel 1/4 in. after machining Date of Heater Manufacture : 10/87 Table 1.

EDDY CURRENT CALIBRATION & INSTRUMENT SETTINGS COMPANY, SITE, UNIT: TVA, Allen Fossil Plant, Unit 3 COMPONENTS: High Press Feedwater Heaters 5 & 6, TUBES: 5/8 x.060" Monel INSPECTOR: Allen Gallaher, E.T. Level III DATE: 11/14/97 MIZ- 17 Channel INSPECTION PROBE F1 F2 Size 0.46 Frequency ( KhZ ) 50 12.5 Frequency ( KhZ ) 20-200 Diff. / Abs. C1 C1 Type C1 Phase 240 195 Manufacturer AECL Gain FO FF CHANNEL: 12 1/2 khz 90 o CRACK GOOD TS AREA 0 o 180 o CRACK ALL CAL. TUBE DEFECTS CRACK 270 o The Carter C1 eddy current probe is designed to detect circumferential cracks and to minimize response to conditions that are radially symmetrical such as tubesheet presence and the change in ID at tube expansion rolls. With no calibration standards available for these conditions a pattern recondition procedure was developed by comparing signals from failed tubes where leaks where observed visually with those from other tubes where no leaks were evident. The probe was obtained from the EPRI NDE Center in Charlotte, North Carolina. Figure 2

25% 180 TVA - ALLEN FOSSIL PLANT - UNIT 3 HP FEEDWATER HEATER # 5 - FAILED TUBES VS TIME 160 20% 140 FAILED TUBES 120 100 80 CUMULATIVE FAILURES 15% 10% FAILED TUBES 60 40 20 INITIAL OPERATION OF HEATER 5% 0 1/88 1/89 1/90 1/91 1/92 1/93 1/94 1/95 1/96 1/97 1/98 1/99 1/00 0% Figure 3. 200 25% 180 TVA - ALLEN FOSSIL PLANT - UNIT 3 HP FEEDWATER HEATER # 6 - FAILED TUBES VS TIME 160 20% 140 CUMULATIVE FAILURES FAILED TUBES 120 100 80 15% 10% FAILED TUBES 60 40 20 INITIAL OPERATION OF HEATER 5% 0 1/88 1/89 1/90 1/91 1/92 1/93 1/94 1/95 1/96 1/97 1/98 1/99 1/00 0% Figure 4.

TUBE SHEET / TUBE CROSS SECTION (MIN.) 1/8" 1 1/4" TUBE SHEET 2 1/4" 1/2" TUBE SEAL WELD CLADDING LOCATION OF CRACKS 10 1/4" Figure 7. TUBE INSERT CROSS SECTION 15" MATERIAL : O.D. : WALL THICKNESS : LENGTH : 304 SS 0.485 in. 0.020 in. 15 in. Figure 8. ube Sheet / Tube / Cross Section sert Cross Section 1 1/4" (MIN.) 1/8" TUBE SHEET / TUBE / INSERT / CROSS SECTION TUBE SHEET 2 1/4" 1/2" INSERT SEAL WELD TUBE CLADDING LOCATION OF CRACKS 15" 10 1/4" Figure 9.

Plugged Tube # # # ) ) ) ) ) ) ) ) ) ##)#)))))))##))))# ))))))))))))))#)))))) )) )))))))))))))))##) )# #))#)#)))#))#)))))))))))))) )#))))#))))))))))))))))))))) ))###))#)))))))))))))))#))##))) ))))))#))))))))))))#)#)))))))) ))))))))))))))))#)))))))))))))))) ))))))))))))###)###)))##)))#)#))## ))######)#)#)#))#))#)###))#))))###### )))))))))))))))))))))))))))#))#))))))) ))))))))))#))))))))))))#))))))))))))))) )#####)#)###)#)))#)##))##))))))))))))))) )))))))))))))))))))))))#))#)))))))))))) )))))))))))))))))))))###)))))))))))))))) ))))#)#)#)))))))#)#)))))))))))))))))))))) ))#######)#######))))#)))#)))))#)##)#### #)))))##)#))# )######)))))#)) ))))))))))#)) )#))#))#)#)) )))))))))#)))) ##)))))####) )))))))))#)## #)##)))#))))))) ))))))))))))) )))))))))))) )))))))))))))) ))#))))))))) )))))))))))) ))))))) ))))))) )))))))))))) )))))))))))) ))))))) ))))))) )))))))))))) )))))))))))) )))))))))))))) ))#))))))))) )))))))))#)## #)##)))#))))))) ))))))))))))) )#))#))#)#)) )))))))))#)))) ##)))))####) #)))))##)#))# )######)))))#)) ))))))))))#)) ))#######)#######))))#)))#)))))#)##)#### ))))#)#)#)))))))#)#)))))))))))))))))))))) )))))))))))))))))))))###)))))))))))))))) )))))))))))))))))))))))#))#)))))))))))) )#####)#)###)#)))#)##))##))))))))))))))) ))))))))))#))))))))))))#))))))))))))))) )))))))))))))))))))))))))))#))#))))))) ))######)#)#)#))#))#)###))#))))###### ))))))))))))###)###)))##)))#)#))## ))))))))))))))))#)))))))))))))))) ))))))#))))))))))))#)#)))))))) ))###))#)))))))))))))))#))##))) )#))))#))))))))))))))))))))) #))#)#)))#))#)))))))))))))) )) )))))))))))))))##) )# ))))))))))))))#)))))) ##)#)))))))##))))# ##))))))))) Allen Fossil Plant Unit 3 HP Feedwater Heater #5, Sept. 99 Figure 5. Plugged Tube # ) ) ) ) ) ) ) ) ) ) ))))))))))))))))) ) )))))))))))))))))) ) ))))))))))))))))))))))))) )))))))))))))))))))))))))) ))))))))))))))))))))))))))))) )))))))))))))))))##))))))))))) ))))))#)))))))))#))#####)))))#) )))))))))))))))#######))######)))) ))##))##)#))))))#)))))))))))##))))) ##)##))))))))#)))))))##))#)))##))))) #)####)#))))))#)))))))##)#)))#))#)))### ))))))))))))))#))#))########)########))) )))##))))))))))))))))#############))))))) ))##)##)))##))#)))))))#))))))#)##))#))#))# ))))###)))))))))))))##)#)###)#)))#))))))) )#))))###)#))#)#))##))))))))###)))#)##)#)) #))))))##)#))))))))))))))))))))#))))))))))) ))))))))))))) )))))))#)))))) ))))))))))))) ##))))))))))) #)))))))#)))))) )#))))))##)#) )))))))#))))) )))##)))#)#)#) )))#)#))#)))) )))))#))#)#))) )#))))))))))))) )#)))))))))))) )))))))))))) ))##)))))))))) ))#))#))#))) ))##))##)))#) ))##)))#))))))) ))####))))#)) ))##))##)))#) ))##)))#)#))))) ))))####))))# )))))))))))) ))##)))))))))) ))#))#))#))) )))))#))#)#))) )#))))))))))))) )#)))))))))))) )))))))#))))) )))))))#)))))) ))##)))#)#)#) ##))))))))))) #)))))))#)))))) )#))))))##)#) ))))))))))))) )))))))))))))) ))))))))))))) #))))))##)#))))))))))))))))))))#))))))))))) )#))))###)#))#)#))##))))))))###)))#)##)#)) ))))###)))))))))))))##)#)###)#)))#))))))) ))##)##)))##))#)))))))#))))))#)##))#))#))# )))##))))))))))))))))#############))))))) ))))))))))))))#))#))########)########))) #)####)#))))))#)))))))##)#)))#))#)))### ##)##))))))))#)))))))##))#)))##))))) ))##))##)#))))))#)))))))))))##))))) )))))))))))))))#######))######)))) ))))))#)))))))))#))#####)))))#) )))))))))))))))))##))))))))))) ))))))))))))))))))))))))))))) )))))))))))))))))))))))))) ))))))))))))))))))))))))) ) )))))))))))))))))) ) ))))))))))))))))) )))))))))) Allen Fossil Plant Unit 3 HP Feedwater Heater #6, Sept. 99 Figure 6.