Technical Bulletin 141. Installation and Maintenance Cost Evaluation. by:



Similar documents
Technical Bulletin 144. Air Volume Conversions. by:

a division of Environmental Dynamics International 2015 Parts Catalog

Watts Pure Water Systems

General Purpose ph/orp Sensors

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

AIR PUMPS & ACCESSORIES

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

Server Chassis and Triplet Hardware v1.0

The Beginning Balance for Meal Plan #1 is: $ (Your daily average should be $2.96)

Aeration Efficiency Guide

Element D Services Heating, Ventilating, and Air Conditioning

Hanna delivers the technical and marketing expertise needed to produce a car wash that meets the car wash customer's expectations.

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

Excerpts from the Canadian National Building Code (NBC)

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Fiber Optic Cable Assemblies. Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable

Teksam Pipe Cast CV 2600

2. Division 05 Structural Steel Framing for steel framework requirements

Access Server Rack Cabinet Compatibility Guide

Injection Systems INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL SYSTEMS

WATER/WASTEWATER: ACHIEVING THE THREE LEVELS OF REDUNDANCY

Harness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

HENDERSON WHEEL & WAREHOUSE SUPPLY HEAVY DUTY STEEL TRUCK WHEEL CATALOG January 2013

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

6 Crankcase Ventilation

Flextray - Installation. Installation

Owner s Manual Gantry Cranes

Replacing Displacers with Guided Wave Radar

DCF Optimized Rack System

Innovative Products For Unique Applications. A Tradition of Excellence. Creative Engineering for Fluid Systems. Earthquake Proof Valves

Section A. GENERAL INFORMATION

Modifying the Yaesu FT-847 External MHz Reference Input

3.36 kw Solar PV Kit Pricing

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

ADVANCED LAGOON TREATMENT TECHNOLOGIES FOR WASTEWATER TREATMENT

Pole Data Sheets (CDN) INFRASTRUCTURE FOR LIFE

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual.

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

Service Parts Diagrams. For Model: UX60-SB600

Finding and Fixing Oil leaks on the LT5 Engine Marc Haibeck

Flow Measurement Options for Pipeline and Open Channel Flow

PRESSURE REDUCING CONTROL VALVE

8D.1 BALL ANGLE METER VALVES - 3/4" & 1" P B E B B B-24267

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

know-how Giant in distributing electricity for industry Prisma GK

Videoconferencing Room Guide

Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction Software Installation 2

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

Rackmount Intelligent Pressure Scanners

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

MUELLER FALLING FILM CHILLERS

Module 7. Plumber: Sink Installation

Water Treatment and Reverse Osmosis Systems

How To Replace A Lower Rail

BRUNS-PAK Presents MARK S. EVANKO, Principal

Using Portable Spot Air Conditioners in Industrial Applications

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

FiberOptix TM. AP Sensor Zeroing and Calibration Guide INTRA-AORTIC BALLOON PRODUCT SUPPORT HOTLINE. U.S. and Canada: IABP (4227)

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

The Unique Accelabar Flow Meter

I BEAM TRACK INSTALLATION

Saferand easierinstallation

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

Modular Studios From small, standard Voice-Over booths to large, custom-designed TV production studios

Powers Controls TH 192 S Single Temperature Room Thermostat

Green Thread Product Data

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

How To Replace A Reverse Osmosis Water Tank

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Design & Construction Standards, Revised January

EVAPCO ENGINEERING. Commercial HVAC. District Energy. Industrial Process. Industrial Refrigeration. Power

LIEBERT VNSA Installation Sheet

DATA CENTER RACK SYSTEMS: KEY CONSIDERATIONS IN TODAY S HIGH-DENSITY ENVIRONMENTS WHITEPAPER

Drum Dispensing Stations

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Submersion/Insertion Toroidal Sensor

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

Rack & Stack 123 TM. Enterprise Education Government Telecommunications Service Providers Tel:

INSTALLATION INSTRUCTIONS

Sealant. 30" Model No D: 17-7/8" TO 18-3/8" (454 to 466mm) W: 29-3/4" TO 30-1/4" (756 to 768mm) Under Countertop Installation

Simple Electrical Utility Cost Allocation Solutions

Steam Coil Installation, Operation and Maintenance

Oracle TimesTen In-Memory Database on Oracle Exalogic Elastic Cloud

Presented By: Justin Cira MTech Company. Your future, Condition Assessment and Sewer Asset Management tool

SAFETY SAFETY APPAREL 20,000 PSI

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007

FAAST. Fire Alarm Aspiration Sensing Technology

DOMESTIC WASTEWATER SYSTEMS

Welding Reels HANNAY REELS. For use for: Arc Welding Gas Welding Cutting Operations H-9422-W Rev. 5. The reel leader.

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

with installation dynafact boost GAUGE this manual is for use with systems

Transcription:

Technical Bulletin 141 Installation and Maintenance Cost Evaluation by: Environmental Dynamics International Published: 6/2005

BULLETIN BRIEF This Technical Bulletin and attached drawings illustrate the total system cost analysis comparison of alternate diffuser platforms, (tube, MiniPanel, disc, other). The industry recognizes three primary diffuser platforms (types), the disc, tube, and panel. EDI manufactures and supplies all three platforms to the industry. 1 A separate tube analysis is available on request. To allow an unbiased comparison of the characteristics and benefits of each platform only EDI diffuser systems will be analyzed and compared. Note: separate comparisons of benefits of one disc, tube or panel system versus a competitive system are also possible but beyond the scope of this general platform comparison. DISCLAIMER Technical Bulletins are presented as a service by Environmental Dynamics International headquartered in Columbia, Missouri USA. For additional more information regarding this particular bulletin or your specific aeration application contact Environmental Dynamics International by calling +1.573.474.9456, toll free at +1.877.EDI.AIR8 (877.334-2478), or via email at techbulletins@wastewater.com. 1 Only disc and MiniPanels shown in this example as each have similar performance based on equal AT/AD and equal air loading/sq m (ft 2 ) of membrane area. Tubes are not included in this analysis as the same AT/AD produces less SOTE. The same SOTE is available with tubes with significant increase in area of membrane. Tube systems have benefits on capital cost when same area of membrane but slightly reduced SOTE. 1

TECHNICAL BULLETIN 141 INSTALLATION AND MAINTENANCE COST EVALUATION All premium quality diffusers types (platforms) can give similar SOTE and mixing performance when properly applied and properly installed! EDI offers a full spectrum of diffuser platforms utilizing disc and MiniPanels to allow Customers, Engineers, and Market Partners to select diffuser platforms and develop systems optimized for each application. The following examples demonstrate the advantages/disadvantages comparison of three EDI diffuser platforms/configurations designed to offer similar performance/capacity. Examples selected show a typical layout drawing of each system with typical design, installation and operation data displayed for comparison. Items shown are key variables for evaluation of any diffuser platform. Considerable supplemental criteria are available from EDI on each of your projects to assist or reinforce your Diffuser Platform selection and design. For this typical example the analysis confirms the following: 1. MiniPanels, disc, or tubes can deliver the same SOTE. 2. All diffusers at same submergence. 3. Active diffuser area of each diffuser platform may vary (AT/AD) to match SOTE requirements. 4. Airflow stays constant. 5. Layout varies greatly. 6. Cost varies greatly. 7. Ease of installation ion and maintenance varies greatly. In addition to the economic comparison shown, there are many other variables that may be very important on any project. Partial List of Other Variables: Ease of Basin Drain and Clean Access for Operation and Maintenance Maximum Product In Basin Capacity Efficiency Strength of Materials and Systems Net Present Value (NPV) analysis of life cycle system cost EDI s Value Added Services will generally include an analysis of most variables for your reference. 2

All diffuser options presented compare two main cost items: Installation costs and maintenance costs. 1. Capital and Installation Cost a. System cost: the capital cost for the diffuser units, the piping, pipe supports, etc. b. Piping installation: time needed to install the piping system. c. Diffuser installation: time to install the diffuser units on the already installed piping system. 2. Maintenance Costs (Membrane Replacement) a. Membrane cost: the replacement cost for the diffuser membranes only. b. Maintenance time: the time needed to change membranes on this typical system. Please note: All installation and membrane replacement times are based on typical values from EDI and EDI Market Partner experience and may vary with the piping layout, experience, etc. Typical Disc Diffuser Platform (Case I) The EDI 9 inch (230 mm) disc platform shows a typical full grid disc system with either threaded as shown in Figure 1 or KlicLoc saddle mounted disc unit shown in Figure 2. 3

Figure 1 Figure 2 To achieve specified performances, a system active area diffuser (AD) of approximately 182.8 ft 2 (17 m 2 ) is required, i.e., 441 of the 9 inch (230 mm) discs are needed (AD = 0.409 ft 2 (0.038 m 2 ) per disc). Discs are mounted on 9 laterals with 49 discs each. To simplify the comparison of all options, all cost and time values of this full grid disc system are set to 100%. All other options will be compared to this 100% baseline disc diffuser grid reference. Optional Disc Diffuser Platform Model 8P (Case II) This is a special design with eight 9 inch (230 mm) diffusers mounted to create the Model 8P diffuser assemblies utilizing EDI special saddle mount which can typically be installed more efficiently. For details about this Model 8P diffuser type, see Figure 3 below. Figure 3 To achieve the same performance as the Case I disc arrangement, the same system AD of approximately 182.8 ft 2 (17 m 2 ) is also required. Use 56 of the Model 8P diffuser units with a total of 448 nine inch (230 mm) discs. Model 8P assemblies are mounted on 2 laterals with 28 Model 8P duplex units each lateral. 1. Capital and Installation Cost a. System Capital Cost: offers approximately 10% savings versus standard disc option. Cost of additional parts (saddle, etc.) are offset with cost savings because of less piping and fewer pipe supports. 4

b. Piping Installation Time: reduced with 2 laterals and a subheader to be installed instead of 9 laterals and a subheader at the full grid disc system. A 75% savings in time to install the piping system is typical. c. Diffuser Installation Time: 56 Model 8P duplex units can be installed much faster than 441 nine inch discs if the saddles and diffusers on the Model 8P are factory mounted. Factory assembled Model 8P units offer 80% installation savings. Total field installation of saddles and diffusers is approximately the same as standard disc arrangement, i.e., zero savings. 2. Maintenance Costs (Membrane Replacement) Membrane Cost and Time: As the EDI Model 8P system consists of approximately the same number of 9 inch discs as a full grid disc system, no savings are achieved versus standard grid system. EDI MiniPanel Diffuser Platform (Case III) The EDI MiniPanel system is a top only perforated tubular diffuser with 4.5 inches (122 mm) OD and 58 inch (1359 mm) membrane length. It combines the benefits of a disc or panel diffuser with all the benefits of a tube diffuser, i.e., simple piping, easy membrane change, low stress on the membrane, etc. For details about the MiniPanel diffuser refer Figure 4 below. Figure 4 To achieve the same performance as the Case I or Case II disc systems, the same AD of approximately 182.8 ft 2 (17 m 2 ) is also required. The MiniPanel diffuser units have AD = 2.54 ft 2 (0.236 m 2 ) per membrane = 5.08 ft 2 (0.472 m 2 ) per MiniPanel duplex unit with 36 units required. MiniPanels are mounted on 2 laterals and require only 18 MiniPanel duplex units each lateral. 5

1. Capital and Installation Cost a. System Capital Cost: because of the reduced number of diffusers and laterals, hardware cost savings of approximately 20% can be achieved compared to a full grid disc system. b. Piping Installation Time: same piping layout as the Model 8P system with same savings of approximately 75% versus typical disc grid configuration. c. Diffuser Installation Time: 36 MiniPanel duplex units are fully factory assembled and are even faster to install with approximately 95% savings. 2. Maintenance Costs (Membrane Replacement) a. Membrane costs are reduced versus discs at typical 20% savings. b. Membrane Replacement Time: Each MiniPanel membrane replaces approximately six 9 inch disc (230 mm) disc membranes. Major maintenance cost and time savings are achieved for membrane replacement with EDI MiniPanel system. Time savings of about 75% are typical. Combining all the cost and time saving benefits of the EDI MiniPanel system with the mechanical benefits the MiniPanel diffuser platform typically offers the most reliable and cost effective aeration solution. Refer to the chart below and subsequent figures 5-7 for more details. 6

Figure 5 Figure 6 7

Figure 7 8