PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS



Similar documents
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Digital input modules

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Telephone- and leased line modem for industrial applications TD-36

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Multifunction devices

Quick Connect. quick - simple - efficient.

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

DCS Input/Output Relay Card Series

Energy Management Energy Meter Type EM23 DIN

Contents. Document information

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Modular I/O System Analog and Digital Interface Modules

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

TrueAlarm Fire Alarm Systems

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

HCR3.2/.. Chipcard reader HOTEL SOLUTION

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

ZC-24DO CANopen I/O Module: 24 Digital Outputs

HERZ-Thermal Actuators

ADM1TE 5/30A DIN rail single phase two wire energy meter

TMS TANK MANAGEMENT SYSTEM

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

is then retained absolutely without interruption.

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Description. Dimensions. Features. precision works better

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

CONFIGURABLE SAFETY RELAYS

PCS0100en Persy Control Services B.V. Netherlands

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Rack mounted telephone- and leased line modem for industrial applications

Repeaters and Mimics Data Sheet

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Color Mark Sensor with Red or Green LED E3S-VS

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

STERILIZERS, LABORATORY DRYING OVENS

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Combi B Alarm box. Mounting instructions

RY2 miniature industrial relays

How To Use A Flowmeter

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Expandable with a safe bus system

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

CONFIGURABLE SAFETY RELAYS

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Remote Monitoring and REC 501 Control Unit Product Guide

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

instabus KNX / EIB System System E F G H

AIS750 Series Alarm Annunciator

API Marine. BMS Presentation. Ballast Measurement Systems

E-STOP relays, safety gate monitors

Product and functional description

Electronic Control Devices The European Product Catalogue 2007

BOS 73K... BOS 74K...

Talon and Talon SR User Manual

Process Alarm Solutions

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

L304 LED PUSHBUTTON SWITCH / DISPLAY INDICATOR INDICATEUR LUMINEUX A LED / BOUTON POUSSOIR

Speed Control Relays SX2

Turbine Flow Sensor Series VTR

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Safety technique. Emergency stop module BO 5988 safemaster

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

EMF/EMR. Holder/Release Devices with Integral Door Closers

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

T0118 T2118 T3118. Instruction Manual

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

12 Series - Time switches 16 A. Features

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Transcription:

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797 http:// www.ecm-france.com Electronic Control Measurement Inc 464 commercial drive BUDA 78610 - TEXAS (512) 2959752, Fax (512) 2959753

CAPELLA RANGE The CAPELLA range is a series of electronic modules intended for vehicle classification systems in toll-plaza lanes, and serve as the interface between the sensors and a data processing unit. These modules collect the information provided by the various types of sensors (electromagnetic loops, piezo-electric and resistive sensors, photo-electric cells, etc.). The CL module processes these signals, and provides a simple and comprehensive classification solution. Fitting and pre-wiring of the modules in a CPC case offers the possibility of a readyfor-use system. Characteristic of the range : Ease of Installation : Mounted on DIN rail, they are fitted with terminals for connecting up the sensors and PC links. the terminal layout of each module is indicated in diagram form on the front panel. Activation indicators ease maintenance operations. Modular : Users can select modules according to the required application configuration. Isolation - protection: Using a series of modules from the CAPELLA range guarantees galvanic isolation (1500V RMS) between the sensors, the power supply network and the PC links, thereby offering protection to equipment fitted further up line. Environment : Storage temperature : - 40 à + 80 C Operating temperature : - 25 à + 70 C Relative humidity <95% without condensation

CAPELLA RANGE CAPELLA BCL Electromagnetic loop detector. This provides either a calibrated pulse and/or a pulse proportional to the presence time of the vehicle. Frequency, sensitivity, and presence time can be set from the front panel. CAPELLA CP-2 Detector for two piezo-electric sensors. This generates a calibrated pulse per detected axle, overcoming problem of rebound and vibration. When an axle is detected, the output photo-coupler transistor conducts and the corresponding indicator lamp lights up. The unit operates from a 24 V DC supply. CAPELLA CR-2 Detector for two resistive sensors. This generates a pulse with a duration equal to the activation time of the sensor. when an axle is detected, the output photocoupler transistor conducts and the corresponding indicator lamp lights up. Operation if from a 24V DC supply..capella TOR-2 Detector for two '0 or 1' signal. This generates a pulse with a duration equal to the activation time of the input signal. A micro-switch enables the module to be used either in positive or negative logic. The lamp indicates an active input state (contact closed or transistor conducting). Operation is from a 24V DC supply. CAPELLA CL Classification module. This unit operates from a 24V DC supply. From the information coming from the CAPELLA detection modules (a maximum of 12 sensors), it provides the category of the vehicle detected both via an RS-232C link and a display. The unit also provides 'vehicle presence' information on a photocoupled output and on a green lamp. A red lamp indicates a classification error and its nature is given on the display. The three available '0 or 1' output as well as the vehicle categories can be changed to suit to the requirements of the customer. As an option, the RS-232C can be replaced by an RS-485 link.

CAPELLA CR-2 MODULE The CAPELLA CR-2 processes signals coming from two resistive sensors. It produces a pulse with a duration equal to the activation time of the sensor. When an axle is detected, the photocoupler output transistor conducts and the corresponding lamp lights up. Operation is from a 24V DC supply. CAPELLA CR-2 diagrams Electrical characteristics : Supply 24 V DC (+ 10%) Quiescent current : 7 ma Maximum current : 32 ma Photo-coupled outputs Galvanic isolation 1500 VRMS In front panel : Indicator "RES 1" (red), Indicator "RES 2" (red), active on detection of an axle. Dimensions in mm Dimensional characteristics : Size : See box. Fixation on a symmetrical DIN rail or Fixation using two M3 screws (75x60mm) Environmental characteristics Storage temperature : -40/+80 C Operating temperature : -25/+70 C < 95% RH without condensation

CAPELLA CP-2 MODULE The CAPELLA CP-2 processes signals coming from two piezo-electric sensors. This generates a calibrated pulse per detected axle, overcoming problems of rebound and vibration. When an axle is detected, the output photo-coupler transistor conducts and the corresponding indicator lamp lights up. The unit operates from a 24V DC supply. CAPELLA CP-2 diagrams Electrical characteristics : Supply 24 V DC (+ 10%) Quiescent current : 11,5 ma photo-coupled outputs Galvanic isolation1500 VRMS On front panel : Indicator "Piezo 1" (red), Indicator "Piezo 2" (red), active on detection of an axle. Dimensions in mm Dimensional characteristics : Size : See box. Fixation on a symmetrical DIN rail or Fixation using two M3 screws (75x60mm) Environmental characteristics : Storage temperature : 0/+80 C Operating temperature : -25/+70 C < 95% RH without condensation

CAPELLA TOR-2 MODULE. The CAPELLA TOR-2 processes two '0 or 1' signal (dry contact, open collector, photocoupler). It produces a pulse with a duration equal to the activation time of the input signal. A micro-switch enables the module to operate either in positive or negative logic. The lamp indicates an active input state (closed contact or transistor conducting). Operation is from a 24 VDC supply. CAPELLA TOR-2 diagrams Electrical characteristics : Supply 24 VDC (+ 10%) Quiescent current: 13 ma Maximum current : 35 ma photo-coupled outputs Galvanic isolation 1,500 VRMS On front panel : Indicator "AON 1" (red), Indicator "AON 2" (red), Micro-switch for selecting logic ( P = positive, N = négative ) Dimensions in mm Dimensional characteristics : Size: See box. Fixation on symmetrical DIN rail or Fixation using two M3 screws (75 x 60mm) Environmental characteristics : Storage temperature : -40/+80 C Operating temperature : -25/+70 C < 95% RH without condensation

CAPELLA BCL MODULE The CAPELLA BCL module is a vehicle detector operating from a electromagnetic loop. It is fitted in a IP40 plastic case for easy mounting on a DIN rail. Frequency, sensitivity and presence time settings are accessible from front panel. The loop is connected on front panel for easy maintenance test. Frequency setting High frequency Low frequency Output setting R switch NC contact NO contact Configuration Terminals Sensitivity S switch 00 0,64 % 01 0,16 % 10 0,04 % 11 0,01 % Presence time H switch 0 V : Ground 16 : Contact 1 (presence) 24 V : 24 V AC or DC 15 : Contact 1 (presence) 28 : Contact 2 (pulse) 25 : Contact 2 (pulse) Dimensions in mm 5 min Permanent Electrical characteristics : Supply : 24 V AC/DC +/- 10 % Power requirement : 1,5 W max. Output 1 & 2 : dry contact Automatic matching (25 à 800µH) Response time : 80 ms On front panel : Frequency setting (2) Sensitivity setting Presence time (5 min / permanent) Red light : "detection" Green light : - permanent : operating - blinking : calibration - turned off : loop fault Dimensional characteristics : Size : see box. Fixation on a symmetrical DIN rail Environmental characteristics : Operating temperature : -20/+80 C < 95% RH without condensation

CAPELLA CL MODULE The CAPELLA CL is the classification module of the CAPELLA range. It operates from a 24V DC supply. From the information coming from the CAPELLA detection modules (a maximum of 12 sensors), the unit may provide via serial link and display : - vehicle category (according to a user defined class definition table), - twined axle detection, - anomaly information, - trouble shooting information (detection of damaged sensors), - normal or reverse way detection, - secondary sensors activation report (e.g. height threshold cell). It also supplies 'vehicle presence' information on a photo-coupled output and on a green lamp. A red lamp indicates a classification anomaly. Three available '0 or 1' outputs can be varied to suit the customer requirements, as can the vehicle categories. As an option the RS- 232C can be replaced by an RS-485 link. Electrical characteristics : Power Supply : 24 Vcc (+ 10%) RS-232 or RS-485 serial link Galvanic insulation 1,500 VRMS 12 "0 or1" inputs and 4 "0 or 1" outputs Dimensional characteristics : Size : 140 x 84 x 58 mm Fixation on symmetrical DIN rail or On front panel : 'Vehicle presence' indicator (green) 'Anomaly' indicator (red) 2-digits LCD display 9-pin SUB D connector (serial link) Environmental characteristics : Storage temperature : -40/+80 C Operating temperature : -25/+70 C Fixation using two M3 screws (133 x 75 mm) < 95% RH without condensation

CAPELLA CPC CABINET Characteristics : Dimensions : 400 x 400 x 200 mm Fixation : 4 x M8 (450 x 300 mm) Protection index : IP55 Material : 1.5 mm mild steel sheet Shade : RAL 7032 Cabinet CPC-1A Cabinet CPC-2A The cabinet is in 1.5 mm-thick sheet steel coated with an epoxy/polyester paint in shade RAL 7032. It is fitted with a reversible door, invisible hinges, key locks and a cable-gland plate on its lower face. A door-locking assembly, wall fixing lugs and canopy are also proposed. The interior is fitted with a support grid for fixing the DIN rails to support the CAPELLA modules and the various other items of equipment. It is offered both with (CPC- 2A) and without (CPC-1A) a front inspection port. On request, supply can include fitting the modules in the cabinet, pre wiring (internal cabinet connections), addition of a 24 VDC supply from any type of mains power supply, etc. Door locking Wall fixing lugs Canopy