Installation Instructions



Similar documents
E2 Series Electric Furnaces

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

VS CONTROL PACK INSTALLATION INSTRUCTIONS

CoolWave r 2 Phase Control Board and Cable Replacement Kits

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Ducoterra Radiant Heating Panel Installation Manual

INSTALLER'S GUIDE. Supplementary Electric Heaters 18-GJ08D1-1. Table of Contents

Your safety and the safety of others are very important.

INSTALLATION & SERVICE MANUAL. Display Panel

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin / March 2013

Installation Instructions

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

Digi-Motor Installation Guide

Advantium 2 Plus Alarm

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Cooktop Low-Profile Ventilation Hoods

TECHNICAL MANUAL GDS8 & GHS8

Cooling Capacity CFM in. w.c. (125 Pa)

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

About the HotWire Slot Standalone Shelf

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

TYPE. MODEL B3200 Roof-Top Air Conditioner used with Mechanical Air Distribution Box INSTALLATION & OPERATING INSTRUCTIONS Air Conditioner

INSTALLATION INSTRUCTIONS

Installation Instructions

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Model. Roof-Top Air Conditioner CARAVAN MODEL B3200 TYPE INSTALLATION & OPERATING INSTRUCTIONS B3200


G670 Intermittent Pilot Ignition Controls

Vision Engravers and Routers PRE-Installation Guide Vision Engraving & Routing Systems

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Oil and Coolant Circulating Heating System. Model - OCSM

Installation and Operation Guide for PD4000 Series Power Control Center

Magnetic Starter - 30A, 120/240V Coils

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

Portable Air Conditioner

MCR1900 Media Converter 19-Slot Chassis

HP UPS R1500 Generation 3

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

INSTALLER S & OWNER S MANUAL

AU-110 racking guide NBXPN: 023

Three-Phase Electric Power Distribution for Computer Data Centers

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

OPL BASIC. Dosing System for Professional Laundry machines. Contents

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system


Installation Guide Content for P250xV-240 microinverters

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

Ceiling Mount Air Handler Manual

INSTALLATION MANUAL INSIDE PASSENGER COMPARTMENT. HFC 134a FOR EUROPEAN SPEC. / GENERAL SPEC. AIR CONDITIONING ENGLISH

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Installation Instructions For Slider Casement Air Conditioners

Installation Instructions

Air Conditioner B B

DC400 Dispensing Cutoff System

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

Your safety and the safety of others are very important.

Installation and Operation Guide for PD4100 Series Power Control Centers

ELECTRONICS G H I J K L M

HEAT WAVE DUCT KIT KIT #

Installation Instructions

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes

INTRODUCTION INTERLOCK KIT K-8110

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

HM-W536 Install Guide

Triac Printed Circuit Board Replacement

Installation and Operation Guide for PD5100 Automatic Transfer Switch

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Dehumidifier Users manual. For Models: DH45S DH65S

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Transcription:

H5HK Series Installation Instructions 3 Phase Electric Heater Kits 7.5 and 0 TON Package A/C Systems Description Installation of 08/40V and 480V H5HK 3 Phase Heater Kits in 7.5 and 0 TON Packaged Air Conditioners. These instructions are primarily intended to assist qualified individuals experienced in the proper installation of heating and/or air conditioning appliances. Some local codes require licensed installation/service personnel for this type of equipment. All installations must be in accordance with these instructions and with all applicable national and local codes and standards. Read these instructions thoroughly before starting the installation. Follow all precautions and warnings contained within these instructions and on the unit. Improper installation, service, adjustment, or maintenance can cause explosion, fire, electrical shock, or other conditions which may result in personal injury or property damage. Unless otherwise noted in these instructions, only factory authorized kits or accessories may be used when modifying this product.

GENERAL INFORMATION H5HK Heater Kits are approved for use in (*)P4SM Packaged Air Conditioners when applied and installed according to these instructions. See Table for approved H5HK/ air conditioner combinations. Refer to the National Electric Code (ANSI/NFPA 70) or in Canada the Canadian Electric Code Part (CSA C..) and applicable local codes for over-current protection and disconnect requirements. If any of the original wiring as supplied with the unit must be replaced, it must be replaced with material of the same gauge and temperature rating. ELECTRICAL SUPPLY! WARNING: To avoid the risk of electric shock, personal injury, or death, disconnect all electrical power to the unit before performing any maintenance or service. The unit may have more than one electrical power supply. If the unit was previously installed without electric heat, the existing supply wiring may not be sufficient to handle the increased load. See the unit ratings label in Table for minimum circuit ampacities and maximum over-current protection ratings. The units with installed electric heat may be supplied by a single circuit or dual circuits. Additional accessory kit is required if dual circuit installation is desired. See Table for accessory description and part number. INSTALLATION Before proceeding with the electrical connections, make certain that the voltage, frequency, and phase of the supply source are the same as those specified on the unit rating label. Also verify that the service provided by the utility is sufficient to handle the additional load imposed by this equipment. Remove the Element/Field Wiring Access Panel. CIRCUIT OPTIONS Units installed with electric heat may be wired for single or multiple circuit supply connections. Single Circuit - Units are factory ready for addition of heater kits. See unit rating label for Minimum Circuit Ampacity and Maximum Over Current Protection of supply wiring. Multiple Circuit - For Dual Electrical Supply connections see unit rating plate or Table, Electrical Data for proper high voltage wiring requirements. Use NORDYNE P/N-97468, 3 Pole Dual Circuit Adaptor for converting to dual supply connections. Refer to the instructions included with the 3 Pole Dual Circuit Adaptor kit Unit Unit Model Heater Kit Heater Kit Wiring Description (*)P4SM- Volts Model H5HK- Part # Kw Circuits Breakers Diagram 009Q-0 9743 9 0 Fig. 3 7.5 Ton 090C 08/40 08Q- 9744 7.4 Fig. 4 Package A/C 035Q- 9745 34.8 Fig. 5 3 Phase 090D 480 08S-0 9746 8 0 Fig. 6 035S-0 9747 34.8 0 Fig. 7 009Q-0 9743 9 0 Fig. 3 0 Ton 0C 08/40 08Q- 9744 7.4 Fig. 4 Package A/C 035Q- 9745 34.8 Fig. 5 3 Phase 0D 480 08S-0 9746 8 0 Fig. 6 035S-0 9747 34.8 0 Fig. 7 3 Pole Dual Circuit Adaptor Part No. 97468-0 Table. Accessories / Applications

6 Pin Plug Connector Control Contactor(s) Limit Switch Electric Heating Elements Location of Dual Circuit Terminal Board (Field Installed Kit) Sequencer(s) Circuit Breaker(s) (If Required) Factory Terminal Board Figure. Location of Typical Major Components for details on how to configure the adaptor for proper Cooling operation hookup. corner of element mounting panel using holes provided. NOTE: Circuit Breakers installed in the unit with the addition of heater kits are for short circuit protection of the internal heater element circuit wiring and NOT to serve as a disconnect. The circuit breakers DO NOT provide over-current protection of the supply wiring. Whether or not circuit breakers are used in the units, over-current protection must be provided at the branch circuit distribution panel and sized as shown on the unit rating label or Table and according to the National Electrical Code, Canadian Electrical Code, and applicable local codes. TERMINAL BLOCKS Approved H5HK heater kits are shipped ready to install using single circuit electrical supply and existing factory installed unit terminal block. If dual circuit supply is desired, follow instructions included in adaptor kit and install in lower left NOTE: Use of 3 pole adaptor is for Cooling circuit only. ELEMENT INSTALLATION! WARNING: Rooftop installations with vertical ducts must have an elbow installed in the supply duct so that the elements are not directly over a supply grille.! WARNING: Heaters may not function properly if elements are not installed per these instructions. 3

IMPORTANT: Application of H5HK-035Q and H5HK-035S in (*)P4SM-090 units. The three (3)- 60 Deg. F High Temperature Limits must be replaced with the three (3)- 0 Deg. F High Temperature Limits supplied with the kit on all 7.5 Ton package units. Ensure all wiring and connections are to unit wiring diagram when complete. Short cycling of equipment will occur if proper limits are not installed. Remove Element/Field Wiring Access panel. Determine the number of element close-off plates to be removed from mounting panel based on size of kit being installed. Set screws aside for later use and discard close-off plates. Install heater elements starting closest to the blower with high temperature limits located at the top of the assembly. Be careful not to damage heater element wires or ceramic element supports while inserting through panel opening. Ensure heater element support rods slide into the alignment holes in the back of the element housing box. Secure the element assembly to the mounting panel with the screws removed when removing the element close-off plates. CONTROL MOUNTING Electric Heater Kits without Circuit Breakers Models H5HK-009Q, -08S, and 035S only. Three pole control contactors locate on the element mounting panel above the factory installed terminal block. See Figure for location of the two () mounting holes required for kit power wiring to be of proper length. Mount contactor with screws provided in kit. Electric Heater Kits with Circuit Breakers H5HK-08Q and 035Q Models only. NOTE: Circuit Breakers supplied with the H5HK electric heater kits are for short circuitprotection of the heater element internal wiring and NOT to serve as a disconnect. Circuit Breakers supplied with the H5HK heater kits DO NOT provide over-current protection of the supply wiring. Over-current protection of the supply wiring must be provided at the distribution panel and sized as shown on the unit rating label or in Table of these instructions. Contactor/Circuit Breaker control panel is shipped fully assembled for mounting above the 4 factory installed terminal block using the six (6) mounting holes provided. See Figure for layout location and mount panel with screws provided in kit. ELEMENT POWER WIRING Elements are shipped with element power wiring ready for attachment to top terminals of the three (3) pole control contactors. Connect the two () w/wh, two () w/bk, and two () Yellow w/bk wires to the corresponding T, T, and T3 terminals of the contactor. NOTE: H5HK-035Q models only - 40 Volt, 35 Kw kits supplied with two sets of six (6) element power wires - the second set of wires will connect to the second or top right control contactor. Connect the two () w/wh, two () w/bk, and two () Yellow w/bk wires to the corresponding T, T, and T3 terminals of this second contactor. Complete the power wiring connections for all kits by attaching the supplied Black, Red, and Yellow or (Black with Yellow markings) from the bottom of the three (3) pole contactors on 009Q, -08S, and 035S models or from the bottom of the Circuit Breakers on 08Q and 035Q models. Connect Black, Red, and Yellow to Lines L,, and respectively. Refer to the specific detailed wiring diagram for all final connections. Make sure all connections are secure. NOTICE TO INSTALLER - Mark the appropriate box on the unit rating label with a permanent X to indicate which heater kit has been installed. Low Voltage Control Wiring Connect the heater kit six (6) pin plug connector to the units mating plug receptacle located in the upper right hand side of the heater element control compartment. Make sure the connection is secure. Complete the low voltage connections by joining the three (3) pin plug and receptacle connectors shipped as part of the heater kit assembly. Make sure the connection is secure. Wiring Diagrams - Wiring Diagrams are shipped with each H5HK Heater kit assembly. Attach the wiring diagram in plain view on the heater element mounting panel. Make sure surface is clean before applying.

AIRFLOW The maximum external static pressure (ESP) for the unit is listed on the unit rating label. The blower speed is preset at the factory for optimum operation in Heating and Cooling modes. It may be necessary for some applications to change the factory set speed. To change the blower speed see the Blower Speed section in the Installation Instructions shipped with the unit. If a lower blower speed is desired from the factory setting then the heater element high temperature limits must be checked for proper operation. Nuisance tripping and cycling of the limits may result with to little of airflow. Limit operation should be checked with return air temperatures between 7 F and 78 F. If a higher blower speed is desired from the factory then no other modifications are required. CLEARANCE All H5HK Electric Heater kits are approved for use in installations with zero-clearance to combustibles at any blower speed for both Horizontal and Downflow applications when installed according to these instructions and other instructions included with the unit and other approved accessories. Circuit Breaker Mounting Panel Holes (Qty. 6) Contactor Mounting Holes (Qty. ) Figure. Control Mounting Location 5

Heater Kit Electrical Data Single Circuit Minimum Rec. Wire Rec. Wire Maximum Unit Model Model Rated Circuit Gage Gage Over-Current (*)P4SM- Number H5HK- Volts Phase Kw Ampacity (60C Cu) (75C Cu) Rating 090C No Kit - - - - - - - - - 4. 4 6 60 7.5 Ton Package A/C 009Q 08/40 3 9 4. 4 6 60 08/30V, 3 Phase 08Q 08/40 3 7.4 60. 4 4 70 035Q 08/40 3 34.8.5 /0 0 090D No Kit - - - - - - - - -.0 0 30 7.5 Ton Package A/C 08S 480 3 8 30.9 8 8 40 460V, 3 Phase 035S 480 3 34.8 56. 4 6 60 0C No Kit - - - - - - - - - 6.3 3 90 0 Ton Package A/C 009Q 08/40 3 9 6.3 3 90 08/30V, 3 Phase 08Q 08/40 3 7.4 63.7 3 90 035Q 08/40 3 34.8 6.0 /0 0 0D No Kit - - - - - - - - - 7. 8 8 40 0 Ton Package A/C 08S 480 3 8 3.6 8 8 40 460V, 3 Phase 035S 480 3 34.8 57.8 4 6 60 Heater Kit Electrical Data Unit Model Rated Model (*)P4SM- Number H5HK- Volts Phase Kw 090C No Kit - - - - - - - - - 7.5 Ton Package A/C 009Q 08/40 3 9 08/30V, 3 Phase 08Q 08/40 3 7.4 035Q 08/40 3 34.8 090D No Kit - - - - - - - - - 7.5 Ton Package A/C 08S 480 3 8 460V, 3 Phase 035S 480 3 34.8 Multiple Circuits Circuit A (Cooling) Circuit B (Heating) Minimum Rec. Wire Rec. Wire Maximum Minimum Rec. Wire Rec. Wire Maximum Circuit Gage Gage Over-Current Circuit Gage Gage Over-Current Ampacity (60C Cu) (75C Cu) Rating Ampacity (60C Cu) (75C Cu) Rating 4. 4 6 60.0 5.3 4 6 60.0 4. 4 6 60.0 04.6 0.0.0 0 30.0 7. 0 0 30.0.0 0 30.0 5.3 4 6 60.0 0C No Kit - - - - - - - - - 0 Ton Package A/C 009Q 08/40 3 9 08/30V, 3 Phase 08Q 08/40 3 7.4 035Q 08/40 3 34.8 0D No Kit - - - - - - - - - 0 Ton Package A/C 08S 480 3 8 460V, 3 Phase 035S 480 3 34.8 6.3 3 90.0 04.6 0.0 7. 8 8 40.0 5.3 4 6 60.0 Table. Electrical Data 6

Figure 3. Wiring Diagram 9 kw, -Stage, 40 VAC NOTES:. If any of the original wire supplied with this unit must be replaced, it must be replaced with wiring material of the same gauge size and temperture rating.. The installation of this heater kit may require a change in the blower speed. See Installation Instructions for details. 3. Use copper conductors with minimum temperature rating of 60C for supply connections. Legend Field Wiring Factory Wiring: Low Voltage High Voltage 3 4 5 6 PLUG HOUSING, 6 PIN GRAY SEQUENCER M M M3 M4 UNIT TERMINAL BLOCK L GND CONTACTOR L T T T3 PLUG HOUSING, 3 PIN 3 CAP HOUSING, 3 PIN 3 70098A 7

8 Figure 4. Wiring Diagram 8 kw, -Stage, 40 VAC NOTES:. Circuit breakers may not be wired to heater kit by the factory, see Installation Instructions for wiring procedure.. If any of the original wire supplied with this unit must be replaced, it must be replaced with wiring material of the same gauge size and temperture rating. 3. The installation of this heater kit may require a change in the blower speed. See Installation Instructions for details. 4. Use copper conductors with minimum temperature rating of 60C for supply connections. 3 4 5 6 PLUG HOUSING, 6 PIN UNIT TERMINAL BLOCK L GND GRAY SEQUENCER M M M3 M4 CIRCUIT BREAKER CONTACTOR L T T T3 PLUG HOUSING, 3 PIN 3 CAP HOUSING, 3 PIN 3 Legend Field Wiring Factory Wiring: Low Voltage High Voltage 70099A

NOTES:. Circuit breakers may not be wired to heater kit by the factory, see Installation Instructions for wiring procedure.. If any of the original wire supplied with this unit must be replaced, it must be replaced with wiring material of the same gauge size and temperture rating. 3. The installation of this heater kit may require a change in the blower speed. See Installation Instructions for details. 4. Use copper conductors with minimum temperature rating of 60C for supply connections. 3 4 5 6 PLUG HOUSING, 6 PIN GRAY SEQUENCER SEQUENCER M M M3 M4 BROWN M3 M4 Legend Field Wiring Factory Wiring: Low Voltage High Voltage CIRCUIT BREAKER CONTACTOR L T T T3 PLUG HOUSING, 3 PIN CAP HOUSING, 3 PIN 3 3 UNIT TERMINAL BLOCK L CIRCUIT BREAKER CONTACTOR L T T T3 GND BROWN 7000A Figure 5. Wiring Diagram 35 kw, -Stage, 40 VAC 9

NOTES:. If any of the original wire supplied with this unit must be replaced, it must be replaced with wiring material of the same gauge size and temperture rating.. The installation of this heater kit may require a change in the blower speed. See Installation Instructions for details. 3. Use copper conductors with minimum temperature rating of 60C for supply connections. 3 4 5 6 GRAY SEQUENCER M M M3 M4 PLUG HOUSING, 6 PIN UNIT TERMINAL BLOCK L CONTACTOR L T T PLUG HOUSING, 3 PIN CAP HOUSING, 3 PIN 3 3 T3 GND Legend Field Wiring Factory Wiring: Low Voltage High Voltage 700A 0 Figure 6. Wiring Diagram 8 kw, -Stage, 480 VAC

NOTES:. If any of the original wire supplied with this unit must be replaced, it must be replaced with wiring material of the same gauge size and temperture rating.. The installation of this heater kit may require a change in the blower speed. See Installation Instructions for details. 3. Use copper conductors with minimum temperature rating of 60C for supply connections. PLUG HOUSING, 6 PIN 3 4 5 6 UNIT TERMINAL BLOCK L GRAY SEQUENCER M M M3 M4 CONTACTOR L T T SEQUENCER M3 M4 PLUG HOUSING, 3 PIN CAP HOUSING, 3 PIN 3 3 T3 GND Legend Field Wiring Factory Wiring: Low Voltage High Voltage 700A Figure 7. Wiring Diagram 35 kw, -Stage, 480 VAC

R REPLACEMENT PARTS LIST 496 Element Ass y - 3.0 kw 7560 Element Ass y - 5.8 kw 497 Element Ass y - 6.0 kw 3 49893 Element Ass y -.6 kw 3 3 6380 Sequencer, -pole, Blower Timing 6383 Sequencer, -pole, Aux. Timing 3 6650 Limit, -pole, 60 F (-0 Models) (3) 3 (3) 6650 Limit, -pole, 0 F (-090 Models) (3) (3) Not Shown 635 Circuit Breaker, 3-pole, 60 amp 6667 Contactor, 3-pole, 40A Res. 6888 Contactor, 3-pole, 50A Res. 3 INSTALLER: PLEASE LEAVE THESE INSTALLATION INSTRUCTIONS WITH THE HOMEOWNER R 707956A 707956A (Replaces 7079560) Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A. (3/00)