Electronic Pressure Switch EDS 300



Similar documents
Electronic Pressure Switch EDS 3000

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Pressure transmitter For general industrial applications Model A-10

Operating instructions Optical distance sensor O1D100 O1D / / 2012

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Inductive sensor NI10-M18-Y1X-H1141

Proportional pressure regulators VPPE

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Conductive Level Switch FK 2 Technical Data:

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Relative and absolute pressure switch type 529

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Digital display DA 48

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Electronic Pressure Monitoring New Products

ATL Fuel Level Sender Probes

Series 6000 Torque measured metal bellow coupling

Digital Pressure Measuring Instrument MDR480

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

UM-X Field display for continous level sensors

ACS-30-EU-EMDR-10-MOD

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

GREISINGER electronic GmbH

How To Make An Ultrasonic Sensor

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

Turbine Flow Sensor Series VTR

Series DFMT Digital Paddlewheel Flowmeter

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Features. Picture. Specifications

Givare NC-SRS 280 och 880

Combi B Alarm box. Mounting instructions

How To Read A Pipe From A Sensor

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

DALI RC BASIC SO. Control unit Operating instructions

MasterINTERFACE 39 Series - Relay interface modules

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Capacitive Prox E2K-X

Instruction Manual Differential Pressure Transmitter

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

crm+25/d/tc/e Extract from our online catalogue: Current to:

Technical Data. Dimensions

Cable Plug acc. to DIN EN , Form A

Electrical connection

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

38 Series - Relay interface modules A

W150: Miniature photoelectric switch series with completely integrated electronics

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Operating instructions Capacitive sensors

LED...A Q Series Sealed High-Intensity

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

REGTRONIC OPERATING INSTRUCTIONS

Liquid Level Limit Switch liquiphant T FTL 20

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Series 7500 Torque Sensor

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

PTU Series Transducer Digital Display Indicator User s Manual

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

psens Pressure Measurement

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

D. PARAMETER SPECIFICATION Measured Variable: Displacement

LCD Readout Digital Pressure Switch

HERZ-Thermal Actuators

Cross-beam scanning system to detect slim objects. 100 mm in

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

ADM1TE 5/30A DIN rail single phase two wire energy meter

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Hand-held thermometer Model CTH7000

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

MasterINTERFACE 39 Series - Relay interface modules

Transcription:

Electronic Pressure Switch EDS 300 User manual

Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5 5.1 Switching outputs...5 5.1.1 Switching point setting (SP)...5 5.1.2 Window function setting (WIN)...5 5.2 Analogue output...6 5.3 Setting the Switching Points and Hystereses...6 5.4 Setting ranges of the switching points and/or hystereses...6 6. Basic settings...7 6.1 Altering the basic settings...7 6.2 Summary of the basic settings...8 7. Programming enable...10 7.1 Altering the operating programming enable...10 7.2 Altering the main programming enable...10 8. Error messages...11 9. Technical specifications...12 10. Circuit diagram...13 11. Model code...14 12. Accessories...15 12.1 For electrical connection...15 12.2 For mechanical connection...15 13. Dimensions...16

Page 3 of 16 1. Functions of the EDS 300 Depending on the l, the unit offers the following functions: Display of the actual pressure, maximum value or a switching point. Switching the switching outputs according to the pressure and the pre-set switching parameters. Analogue output Menu for basic settings (adapting the EDS 300 to the particular application) Two different types of programming enable Three different output ls are available: EDS 300 with 1 switching output (1.2 A load capacity, no analogue output) EDS 300 with 2 switching outputs (1.2 A load capacity, no analogue output) EDS 300 with 1 switching output (1.2 A load capacity) and 1 analogue output (4...20 ma) 2. Mounting The EDS 300 can be mounted directly onto a hydraulic block via the pressure connection (7/16 SAE 4 female). When used in critical applications (e.g. strong vibrations or knocks) the pressure connection must be mechanically decoupled via a Minimess hose. Mounting clamps are available as an accessory (see point 12.2 "Accessories - for mechanical connection"). The electrical connection should be carried out by a qualified electrician according to the relevant regulations of the country concerned (VDE 0100 in Germany). The pressure switch housing must be earthed properly at the same time. When fitted into a hydraulic block it is sufficient if the block is earthed via the hydraulic system. In the case of Minimess hosemounting, the housing must be earthed separately. Additional assembly notes which, from experience, reduce the effect of electromagnetic interference: Make line connections as short as possible. Use screened lines (e.g. LIYCY 4 x 0.5 mm 2 ) The cable screening must be fitted by qualified personnel subject to the ambient conditions and with the aim of suppressing interference. Direct proximity to connecting lines of user units or electrical or electronic units causing interference must be avoided as far as possible.

Page 4 of 16 3. Operating keys on the membrane keypad HYDAC EDS 300 4-digit digital display SP1 PSI SP2 keys for setting switching points, switch-back points and additional functions 4. Digital display After switching on the supply voltage, the unit briefly displays EdS followed by the current pressure. 2 s In the basic settings the display can be altered. For example, the maximum value can be permanently displayed. This is the largest measured value which has been recorded since the unit was switched on or was last re-set. A switching point can likewise be permanently displayed or the display can be set to be dark. Depending on the setting, "TOP", "S.P. 1", "S.P. 2" or "OFF" appears briefly on the display following the switch-on message. The actual pressure can be displayed briefly by pressing the or the key. This causes the maximum value to be re-set. Notes: If the actual pressure exceeds the nominal pressure of the unit, it can no longer be displayed and the display begins to flash. If the actual pressure is below 1 % of the nominal range, then 0 is displayed.

Page 5 of 16 5. Output function 5.1 Switching outputs The EDS 300 has 1 or 2 switching outputs. The following settings can be made under the basic setting: 5.1.1 Switching point setting (SP) One switching point and one hysteresis can be set for each switching output. The respective output switches when the pre-set switching point is reached and switches back when the pressure falls below the switch-back point. The switch-back point is determined by the preset hysteresis (switch-back point = switching point minus hysteresis). Abbreviations: "S.P.1", "S.P.2" = switching point 1 or 2 "h.y.1", "h.y.2" = hysteresis 1 or 2 5.1.2 Window function setting (WIN) The window function enables a range to be monitored. For each switching output, in each case an upper and a lower switching value can be input which determine the range. The respective output switches when the pressure enters this range. Upon leaving the range, i.e. when the switch-back value has been reached, the output switches back. The lower switch-back value is just below the lower switching value (lower switching value minus three times the increment, see point 5.4). The upper switch-back value is just above the upper switching value (upper switching value plus three times the increment, see point 5.4). The area between switching and switch-back value forms a safety zone which prevents unwanted switching operations from occurring (e.g. triggered by pulsations from a pump). Example for switching output 1 (normally open function): P hi.1 plus 3xincrement hi.1 Off Safety zone On Switch-back valuet Switching value Lo.1 Lo.1 minus 3xincrement On Safety zone Off Switching value Switch-back value t ON Off Abbreviations: "hi.1", "hi.2" = High level 1 or 2 = upper switching value 1 or 2 "Lo.1", "Lo.2" = Low level 1 or 2 = lower switching value 1 or 2 Note: The window function only operates correctly (switching on and off), when all switching values (including the safety zone) are greater than 0 bar and lower than the nominal pressure range.

Page 6 of 16 5.2 Analogue output On specified ls, the EDS 300 provides one analogue output with a 4...20 ma signal. 5.3. Setting the Switching Points and Hystereses Press "" key "S.P.1" or "hi.1" is displayed Keep pressing the "" key until the required parameter is displayed (depending on the basic setting: "S.P.1", "h.y.1", "S.P.2", "h.y.2", "hi.1", "Lo.1", "hi.2" or "Lo.2"). After 2 seconds the actual setting flashes. Use the or the keys to alter the setting. Use the "" key to call up other parameters, if required, and alter the setting using the and the keys. If no keys are pressed for 3 seconds, the display changes back and the settings are saved. 2 s press key display set switching point until the required =smaller value parameter is =larger value reached. Notes: 3 s pressure display If "LOC" appears in the display when trying to alter the settings, programming is disabled. Corrective action: set programming enable to "ON" (see point 7 "Programming enable") If the or the key is held down during alteration, the value automatically advances. If a setting has been altered, "PRG" appears briefly in the display when the display is switched over. The new setting is then saved in the unit. 5.4 Setting ranges of the switching points and/or hystereses Measuring range in psi Switching point and/or upper critical value in bar Hysteresis and/or lower critical value in bar Increment * in psi -14.. 75-12.5.. 75.0-0.5.. 74.0 0.5 0.. 150 3.. 150 1.. 148 1 0.. 1000 15.. 1000 5.. 990 5 0.. 3000 45.. 3000 15.. 2970 20 0.. 6000 90.. 6000 30.. 5940 30 0.. 9000 150.. 9000 50.. 8900 50 * All ranges given in the table are adjustable by the increments shown.

Page 7 of 16 6. Basic settings In order to adapt the unit to a particular application, the function of the EDS 300 can be altered via several basic settings. These are combined in a menu. 6.1 Altering the basic settings Important note: when the menu is activated no switching operations are carried out. Switch off supply voltage or disconnect the unit from the supply voltage. 3 s press key and hold down. Switch on supply voltage (hold key down for 3s) display (release key) press key until the required menu point appears in the display. (for summary, see 6.2) 2 s Use or to alter setting, then select next menu point. To close the basic setting menu Call up the menu point "END", set to "YES", the EDS 300 returns to the normal display after 2 seconds. Note: If after about 50 seconds no keys have been pressed, the menu automatically closes down. Any changes which may have been made will not be saved.

Page 8 of 16 6.2 Summary of the basic settings Setting Display Setting range Switching switching output 1 (Sm 1) SP/ Win Presetting SP Switching output 1 operates in switching point / hysteresis function Switching output 1 operates in window function Switching direction switching output 1 (S 1) ON : normally open function. OFF : normally closed function. Switch-on delay switching output 1 (Ton 1) Time in seconds which must elapse, once the particular switching point has been reached or exceeded, before switching will occur. Switch-off delay switching output 1 (Toff 1) Time in seconds which must elapse, once the pressure has fallen below the particular switch-back point, before switching will occur. ON/ OFF ON 0.00..75s 0 0.00..75s 0 Switching output 2, as above Primary display (Primary) Display value which should remain permanently in the display: ACT. : base pressure Top : pressure peak value S.P.1 or S.P.2 :switching point 1 or 2 OFF : display dark (for function, see point 4 Digital display ) Calibration of sensor zero point (Calibrate) YES : The base pressure is saved as the new zero point. This is possible in the range +/- 3 % of the unit s nominal pressure range. new appears in the display when a calibration is carried out in the permissible range, otherwise Err is displayed. This function is useful for example if there is always a residual pressure in the system which should however be displayed as 0 bar. Please note: Following a zero point adjustment, for example, on a 600 bar unit, a pressure of up to 18 bar is displayed as 0 bar. Before any work is carried out on the hydraulic system, ensure that the system is depressurised. ACT/ Top/ S.P.1/ S.P.2/ OFF YES/ NO ACT NO

Page 9 of 16 Version number (Version) Display of the current software version (for reference only) To close basic settings (End) YES/ NO NO

Page 10 of 16 7. Programming enable The unit has 2 types of programming enable which must both be set to "ON" to change the settings. The operating programming enable can be set or removed during operation. It provides protection from unintentional alteration. A programming disable via the main programming enable has the effect that no change to the settings can be carried out during operation. This serves, for example, as a safety function or as protection against unauthorised alterations. 7.1 Altering the operating programming enable press both arrow keys simultaneously and hold down for 3 s 3 s display (release arrow keys) 3 s use or to alter setting, ON = programming possible OFF = programming disabled pressure display 7.2 Altering the main programming enable Switch off supply voltage or disconnect the unit from the supply voltage. 3 s press both arrow arrow keys simultaneously and hold down. Switch on supply voltage (hold keys down for 3 s) "main program state" display (release arrow keys) 3 s use ON or to alter setting, = programming possible OFF = programming disabled pressure display Note: If a setting has been changed "PRG" is displayed briefly when the display is switched over. The new setting is then saved in the unit.

Page 11 of 16 8. Error messages If an error is detected, then a corresponding error message appears which must be acknowledged by pressing any key. Possible error messages are as follows: E 01 The switching points and hystereses have been set in such a way that the resulting switch-back point is no longer within the permissible setting range. Corrective action: Correct the settings E 10 A data error has been detected in the saved settings. Possible causes are strong electromagnetic interference or a component fault. Corrective action: Check all the settings (programming enable, switching points, switch-back points and basic settings) and correct these if necessary. If the errors occur frequently, please contact Hydac Service. E 12 An error has been detected in the stored calibration data. Possible causes are strong electromagnetic interference or a component fault. Corrective action: Switch the unit off and on again. If the error message is still displayed, the unit must be returned to the manufacturer for recalibration or repair. E 20 A short-circuit has been detected on a switching output. Corrective action: Eliminate the short circuit.

Page 12 of 16 9. Technical specifications Input data:: Measuring ranges: -14.. 75; 150; 1000; 3000; 6000; 9000 psi Overload pressures: 150 % FS, max. 13000 psi Burst pressure: 300 % FS Output data: Accuracy (B.F.S.L.) display & analogue ± 0.5 % B.F.S.L. including linearity & hysteresis Repeatability: ± 0.5 % FS max. Temperature drift: zero point max. range max. ± 0.016 % / F ( ± 0.03 % / C) ± 0.016 % / F ( ± 0.03 % / C) Analogue output: 4.. 20 ma, ohmic resistance 400 Ω Switching outputs: Type: PNP transistor output Switching current: max. 1.2 A Switching cycles: 100 million Reaction time: approx. 10 ms Ambient conditions: Temperature range of medium: -13.. 176 F (-25.. + 80 C) Ambient temperature range: -13.. 176 F (-25.. + 80 C) Storage temperature range: -40.. 176 F (-40.. + 80 C) Compensated temperature range: 14.. 158 F (-10.. + 70 C) - mark: EN 61000-6-1 / -2 / -3 / -4 Vibration resistance: approx. 10 g / 0..500 Hz Shock resistance: approx. 50 g / 1ms Other data: Supply voltage EDS 356-1,2: Supply voltage EDS 356-3: 12.. 32 V DC 20.. 32 V DC Electrical connection: plug M12x1 Current consumption: approx. 100 ma (without switching output) Safety type: IP 65 Hydraulic connection: see l code Parts in contact with medium: stainless steel Material of housing: tube: stainless steel keypad housing: PA6.6 Gf30 Display: 4-digit, 7-segment LED, red Weight: approx. 300 g Note: FS (Full Scale) = relative to the full measuring range B.F.S.L. = Best Fit Straight Line

Page 13 of 16 10. Circuit diagram Model with 1 switching output + 20..32 12..32 V - 1 3 EDS 356-1 4 Imax. 1.2 A SP 1 Model with 2 switching outputs + 12 20..32 V - 1 EDS 356-2 3 Imax. 1.2 A 4 SP 1 Imax. 1.2 A 2 SP 2 Model with 1 switching output and 1 analogue output + 20..32 V - 1 EDS 356-3 3 Imax. 1.2 A 4 SP 1 2 I = 4..20 ma analogue RL

Page 14 of 16 11. Model code EDS 3 5 6 - X - XXXX - XXX Series EDS 3 = 300 Series Electronic Pressure Switch Mechanical connection 5 = SAE-4 female thread (7/16-20 UNF2B) Electrical connection 6 = M12x1 plug, 4 pole (connector not included) Output 1 = 1 Switching output 2 = 2 Switching outputs 3 = 1 Switching output an 1 Analog output Pressure ranges 0089 (-14..75); 0150; 1000; 3000; 6000; 9000 psi Modification number 400 = standard in psi 401 = vacuum in psi

Page 15 of 16 12. Accessories 12.1 For electrical connection 4-pole connector with flying leads, M12x1, 90 angled Ø 0.433 (11.0) All dimensions are in inches and (millimeters) 1.528 (38.8) 1.24 (31.5) M12x1 Ø 0.571 (14.5) 0.807 (20.5) 1.043 (26.5) Female interface 3 4 2 1 Wire colors: Pin 1: brown, Pin 2: white, Pin 3: blue, Pin 4: black Available types: ZBE 06-02: Female Screw-Lock Type 90 Connector (2 meter cord) ZBE 06-05: Female Screw-Lock Type 90 Connector (5 meter cord) 12.2 For mechanical connection ZBM 300 clamp for wall-mounting the EDS 300 (material: polypropylene) Mounting: Glue damping strips into the recesses of the base plate. Mount base plate, the top is indicated by "OBEN", "TOP" and 2 arrows. Insert EDS 300. Fit clip (only one possible position) and press hard on the cross-pieces until they engage. ZBM 310 clamp for wall-mounting the EDS 300 (material: polypropylene, aluminium AlSi12, steel) Mounting: Weld the steel base plate Mount EDS 300 in accordance with the drawing

Page 16 of 16 13. Dimensions HYDAC Technology Corporation Electronic Division 2260 City Line Road USA-Bethlehem, PA 18017 Phone.: (610) 266-0100 Fax: (610) 266-3540 E-mail: powerup@hydacusa.com