Study of porosity measurement using the computer tomograph



Similar documents
APPLICATION OF X-RAY COMPUTED TOMOGRAPHY IN SILICON SOLAR CELLS

CT for the production floor: Recent developments in Hard- and Software for industrial CT Systems

MODERN VOXEL BASED DATA AND GEOMETRY ANALYSIS SOFTWARE TOOLS FOR INDUSTRIAL CT

Proper Implementation of Industrial CT Scanning to Reduce Inspection Costs & Get to Production Faster. Jesse Garant, JG&A Metrology Center

Methods for analysis and visualization of industrial XCT data of fibre reinforced composites

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

CT Traceability - Prof. Wim Dewulf, Group T - KU Leuven

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

HIGH RESOLUTION X-RAY MICRO-CT OF ULTRA-THIN WALL SPACE COMPONENTS

3-D Printing Artificial Reservoir Rocks to Test Their Petrophysical Properties*

Development of High Speed Oblique X-ray CT System for Printed Circuit Board

ALGORITHM OF LAYER MODEL

On an equal level: CT measurements reach the accuracy of conventional tactile metrology

CT for non-destructive testing of plastic joints

Data. microcat +SPECT

ELEMENTS OF SOFTWARE INTEGRATION OF PRODUCTION SYSTEMS IN INDUSTRIAL PRODUCT CONTROL AND DIDACTICS 1. INTRODUCTION

High resolution X-ray CT as enabling technology for material research

Industrial X-ray for Nondestructive Testing Unrestricted Siemens AG All rights reserved

Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors

CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL

Checklist for the Qualification of Digital Detector Array Systems

The Basics of Scanning Electron Microscopy

THE ULTRASONIC TOMOGRAPHY TESTS OF CONCRETE IN FOUNDATION SLAB

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

Nanometer-scale imaging and metrology, nano-fabrication with the Orion Helium Ion Microscope

Who are we. Engineering & Quality. Elements & Moulds. Verification. Approx. 800 employees. Approx.330 employees. Approx. 26 employees.

Possibilities and Limits of Digital Industrial Radiology: - The new high contrast sensitivity technique - Examples and system theoretical analysis

Standard Test Method for Classification of Film Systems for Industrial Radiography 1

5-Axis Test-Piece Influence of Machining Position

Performance testing for Precision 500D Classical R/F System

AUTOMATED GENERATION OF 3D MODELS OF HYDRAULIC COMPONENTS ZAUTOMATYZOWANE GENEROWANIE MODELI 3D ELEMENTÓW HYDRAULICZNYCH

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Analysis of Blind Microvias Forming Process in Multilayer Printed Circuit Boards

Computed Tomography Resolution Enhancement by Integrating High-Resolution 2D X-Ray Images into the CT reconstruction

Automotive Applications of 3D Laser Scanning Introduction

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM

DENTAL Cone beam 3D X-RAY SYSTEM with

Reach Higher with Inspection Academy GE s Inspection Technologies Global Knowledge Center.

EASILY AUTOMATE CT INSPECTIONS AND ANALYSES

Series. X-ray Inspection.

VERIFICATION OF GEOMETRICAL ACCURACY OF SELECTIVE LASER MELTING (SLM) BUILT MODEL

MODERN 2D / 3D X-RAY INSPECTION -- EMPHASIS ON BGA, QFN, 3D PACKAGES, AND COUNTERFEIT COMPONENTS

APPLICATION OF SHAPE SENSITIVITY ANALYSIS IN NUMERICAL MODELLING OF SOLIDIFICATION PROCESS

INTRODUCTION. A. Purpose

Synthetic Sensing: Proximity / Distance Sensors

STUDY OF THE INFLUENCE OF SURFACE FORM ERRORS ON THE FITTING UNCERTAINTY IN COORDINATE MEASUREMENTS

VERIFICATION OF THEORETICAL PHONG MODEL IN REFLECTOR LESS SURVEYS

VGStudio MAX 2.2 THE MARKET S LEADING APPLICATION SOFTWARE FOR ANALYSIS AND VISUALIZATION OF INDUSTRIAL COMPUTER TOMOGRAPHY / VOXEL DATA

Technical summary X-LED MESH X-LED - Made by Carl Stahl

Piotr Tofiło a,*, Marek Konecki b, Jerzy Gałaj c, Waldemar Jaskółowski d, Norbert Tuśnio e, Marcin Cisek f

Automated Optical Inspection is one of many manufacturing test methods common in the assembly of printed circuit boards. This list includes:

SPINDLE ERROR MOVEMENTS MEASUREMENT ALGORITHM AND A NEW METHOD OF RESULTS ANALYSIS 1. INTRODUCTION

The Olympus stereology system. The Computer Assisted Stereological Toolbox

GEOMETRIC ACCURACY OF AIRCRAFT ENGINE BLADE MODELS CONSTRUCTED BY MEANS OF THE GENERATIVE RAPID PROTOTYPING METHODS FDM AND SLA

GLOBAL MANUFACTURING. ARAUJO, Anna Carla AUG, 2015 Mechanical Engineering Department POLI/COPPE/UFRJ

QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

Analysis of chaotic dynamics of the Ikeda system of fractional order

Infrared Viewers. Manual

Experimental study of beam hardening artefacts in photon counting breast computed tomography

DETERMINATION OF WOOD MOISTURE PROPERTIES USING CT- SCANNER IN A CONTROLLED ENVIRONMENT

Element Property Definition for the Space Satellite

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging

Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW

Volume visualization I Elvins

Solder joint inspection and analysis

Department of Aerospace Engineering Indian Institute of Science Bangalore

MEDICAL IMAGING 2nd Part Computed Tomography

View of ΣIGMA TM (Ref. 1)

Electron Microscopy 3. SEM. Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts

DIESEL EFFECT PROBLEM SOLVING DURING INJECTION MOULDING

Laue lens for Nuclear Medicine

X-ray Tomography in Industrial Metrology

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

Purchasing a cardiac CT scanner: What the radiologist needs to know

NetShape - MIM. Metal Injection Molding Design Guide. NetShape Technologies - MIM Phone: Solon Road FAX:

How To Design A 3D Print In Metal

Metal Injection Molding (MIM) of components made of Titanium and its alloys

Calibration of AFM with virtual standards; robust, versatile and accurate. Richard Koops VSL Dutch Metrology Institute Delft

X- and Gamma Ray Imaging Systems based on CdTe-CMOS Detector Technology

Multiphysics Software Applications in Reverse Engineering

Tuesday 20 May 2014 Morning

NON-DESTRUCTIVE METHODS. CE 165: Concrete Materials and Concrete Construction

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

Jorge E. Fernández Laboratory of Montecuccolino (DIENCA), Alma Mater Studiorum University of Bologna, via dei Colli, 16, Bologna, Italy

DESIGN AND EVALUATION OF PROBE WITH THREE DEGREE- OF-FREEDOM FOR NON-DESTRUCTIVE TEST USING THREE- DIMENSIONAL FINITE ELEMENT METHOD

The Focused Ion Beam Scanning Electron Microscope: A tool for sample preparation, two and three dimensional imaging. Jacob R.

Easy Quality Control with - PTW Equipment. Code of Practice - Quality control of X-ray equipment in diagnostic radiology

Optical Design for Automatic Identification

ENGINEERING METROLOGY

Spatio-Temporal Mapping -A Technique for Overview Visualization of Time-Series Datasets-

Vertical Cavity Surface Emitting Laser OPV300, OPV310, OPV310Y, OPV314, OPV314Y

Silicon PIN Photodiode

GPU-accelerated Computed Laminography with Application to Nondestructive

Ultrasonic Wave Propagation Review

Infrared Cameras Can Aid Building Inspectors in Detecting Roof Leaks, Water Damage, Mold and Other Moisture Related Problems

Transcription:

Study of porosity measurement using the computer tomograph Tomasz Kowaluk, Adam Woźniak Institute of Metrology and Biomedical Engineering, Warsaw University of Technology Abstract: This paper is concerned with performance of measurement of pore volume in aluminum cast. The experiments were carried out on a METROTOM 800 Carl Zeiss computer tomograph. Results coming from algorithm of automatic detection were compared against to the manual detection according to the ISO surface. Results have been analyzed using the VGStudio MAX software. Keywords: computer tomograph, porosity Introduction The idea of measurements consists of assembling threedimensional spatial object from multiple flat images resulting from the scanning of measured element in the selected angular position. The measured element is set on a rotary table that allows the movement, linear and angular positioning of the component. While the measured object is illuminated by an X-ray beam generated in the tube, the image detection is done at certain angular positions of rotary table on the detector array. Acquired images are processed by specialized software, producing a three-dimensional model of the measured element. While the measured objects absorb energy of X-rays during the measurements, the X-ray beam is therefore weakened and the difference in the intensity of radiation passing through the object is registered on the detector. The change of the intensity of the parallel beam of radiation of the same energy, during the transition through the measuring object is described by the dependency: I = I 0 e -μg [1], where: I intensity of radiation after passing through the object, I 0 initial intensity of radiation, m linear absorption coefficient of radiation, g thickness of the material. X-ray absorption of the tested object is proportional to the density and to the atomic structure of the material and wall thickness of the element [1]. The study was performed on a METROTOM 800 Carl Zeiss (fig. 1) computer tomograph. To the main assembly of computer tomographs the X-ray tube, the radiation detector and a system for positioning the measured element consisting of a rotary table and the linear guideways are included. The data obtained are processed by a separate computer. The computer tomograph METROTOM 800 is equipped with a constant X-ray tube with a power of 39 W (at maximum parameters 130 kv voltage and 300 μa current) and a detector with a resolution of 1536 1920 pixels. Main metrological parameters of the CT are summarized in tab. 1. Fig. 1. Computer tomograph METROTOM 800 Rys. 1. Tomograf komputerowy METROTOM 800 Tab. 1. Metrological parameters of the CT METROTOM 800 [2, 3] Tab. 1. Parametry metrologiczne tomografu komputerowego METROTOM 800 [2, 3] Measuring range: x-y plane: z Workpiece weight, max. Focal spot size, min. 2. The influence of the shape of the histogram on results 170 mm, 190 mm 4 kg 5 μm Geometric magnification (2D), max. 45 Geometric magnification (3D), max. 40 X-ray detector resolution X-ray detector Pixel size MPE E Maximum Permissible Error Error of indication 1536 1920 pixels 127 127 μm 4.5 + L/100 μm (L length of the measured distance mm) The study consisted of checking the obtained values of pore volume in aluminum cast. Theoretically, by measuring the elements which are made of one material in the histogram two peaks should be obtained, one for the air and second for the material. Ideal histogram is shown in fig. 2. Obtaining the ideal histogram allows the use of algorithms for automatic detection of the ISO surface (threshold between background and material). The effect of ISO surface settings are shown in fig. 3. On the left (fig. 3 is visible noise in the central part of the element aluminum casting (automatic algorithm). The settings change will remove noise (manual algorithm) which is shown in the fig. 3b. Changing the ISO value affects not only the removal of the outside noises in the measured element but also of the inside. 82

Tab. 2. The influence of the ISO value settings on results (automatic algorithm and manual setting) Tab. 2. Wpływ ustawienia wartości ISO na wyniki (algorytm automatyczny, ustawienia manualne) pore size Above 0.000 mm 3 Above 0.010 mm 3 ISO value automatic manual automatic manual volume of element mm 3 1016.776 1006.671 1016.877 1006.671 volume of pores mm 3 0.775 0.797 0.250 0.252 percentage of pores 0.0761 0.0791 0.0246 0.025 number of analyzed cross-sections 1455 1540 8 8 Fig. 2. Ideal histogram of grayscale value Rys. 2. Idealny histogram skali odcieni szarości Algorithms for calculation the volume of defects that occur inside of the elements are based on three levels of gray scale values (ISO surface, material and background). The most important is the value of the ISO surface. The software treats this value as a threshold between air and material. Voxels which values are less than ISO are treated as the air, while the values above the ISO are treated as the material. Changing the ISO value influence on the volume of the whole element as well as on detected defects that occur in the element. Table 2 shows the results of measurement of pore size for automatic as well as manual method of determining the ISO value. The user can decide what size of pores should be detected (by setting minimum and maximum volume of pores). It is possible to find the pores from 0 μm 3 to the entire volume of the CT measurement. The effect of the pores size settings are shown in fig. 4. Result of pore detection algorithm (only threshold) is shown in fig. 4 cross section of the aluminum cast with the defined ISO surface (white line which is a border of the material). As it was shown in the magnification, not all pores (black points on the screen) were correctly interpreted. Detected pores do not fill the entire surface determined by ISO line. Additionally, not all detected pores are included in the calculations. This is due to the fact that the algorithm cuts the entire volume of the object with a certain step then analyzes Fig. 3. 3D view of measuring element with the use: automatic algorithm, manual algorithm Rys. 3. Widok 3D elementu pomiarowego z zastosowaniem: algorytmu automatycznego, algorytmu ręcznego 3. Comparison of pore-detection algorithms The study compared two available in the VGStudio MAX software algorithms of pores detection. The first of available algorithms Only treshold based on the threshold and background value. The second algorithm default based on the void max and background value. Fig. 4. Visualization of the occurrence of the pores in aluminum cast: with no limits of pore size, above 0.010 mm 3 Rys. 4. Wizualizacja występowania porów w odlewie aluminiowym: bez ograniczeń wielkości porów, powyżej 0,010 mm 3 Pomiary Automatyka Robotyka nr 12/2012 83

the sections in which the defects are detected a limited number of cross-sections results that not all pores are analyzed. This approach allows to detect only the largest pores, but reduces significantly the time necessary for calculations (single calculation takes 10 minutes). To detect all pores occurring in the aluminum casting advanced algorithms (default and enhanced) must be used. Both algorithms are based on the same values (void max and background) and differ from each other in the number of runs. In the research default algorithms were used. In fig. 5 cross section of the aluminum cast with the defined ISO surface is shown. Fig. 6. Cross section view with marked errors of defects detection algorithm ( default algorithm) Rys. 6. Widok przekroju z zaznaczonymi błędami algorytmu wykrywania wad (algorytm default ) Tab. 3. The influence of the type of algorithm on the results Tab. 3. Wpływ typu algorytmu na wynik pore size Above 0.000 mm 3 Above 0.010 mm 3 algorithm default only threshold default only threshold Fig. 5. Cross section view with marked errors of defects detection algorithm (pores only threshold algorithm) Rys. 5. Widok przekroju z zaznaczonymi błędami algorytmu wykrywania wad (porów algorytm only threshold ) The same as it was previously shown in the magnification, not all pores (black points on the screen) are correctly interpreted. For this algorithm also not all detected pores are included in the calculations. This shows that even advanced algorithms do not detect all the pores. Although pores were closed by ISO surface, not all were analyzed. Operations for calculating the pore volume are performed in the computer s RAM. The advanced algorithm detects more pores but it needs much more time (8 12 hours). Table 3 shows the results obtained from the analysis using two algorithms ( default and only threshold ), depending on the size of the pores (above 0.000 mm 3 and above 0.010 mm 3 ). Depending on the selected algorithm, different values of volume of whole element and of pores in therein occurring are obtained. Changing the range (size) of detected pores in the algorithm parameters influences on changing of volume of the whole element in the case of algorithm default. For the algorithm Only threshold value of the volume of element remains the same. Advanced algorithm detects two orders of magnitude higher volume of pores than the algorithm Only threshold volume of element mm 3 964.653 1006.671 994.540 1006.671 volume of pores mm 3 42.924 0.797 13.165 0.252 percentage of pores 4.26 0.0791 1.31 0.025 number of analyzed cross-sections 70 358 1540 241 8 (for the tested aluminum casting). The number of analyzed cross sections is significantly dependent on the threshold of pores detection as well as of the type of algorithm. Advanced algorithm analyzes two orders of magnitude higher the number of cross sections than the basic algorithm. 4. The influence of magnification on the results An important question which must be considered is the influence of used magnification on the obtained results. To be able to check the influence of magnification on results appropriate gauges should be used. Gauges should be possible to estimate the actual volume of pores for example by gravimetric method [4, 5], or using materials of known estimated pore sizes [6]. 84

Fig. 7. 3D reconstruction of the gauge with marked pores: with the 8 μm magnification, with the 25 μm magnification (size of single voxel) Rys. 7. Rekonstrukcja 3D wzorca z zaznaczonymi porami: przy powiększeniu 8 μm, przy powiększeniu 25 μm (rozmiar pojedynczego woksel The study used a different approach. It was constructed a gauge which consists of two cylinders. The first cylinder was created with hole so that the second cylinder with four smaller drilled cylinders can by molded. Theoretically, a gauge with the four pores should be obtained. In fig. 7 results of reconstruction of pores which are in the gauge at different magnifications (8 μm ( and 25 μm () are shown. As it was shown at a magnification of at 8 μm (fig. 7 pores between the two cylinders are visible. While at a magnification of 25 μm (fig. 7 only artificially produced in the gauge pores are visible. This is caused by the use of the basic algorithm only threshold based on the ISO surface. At lower magnifications, the algorithm does not detect the surface between two cylinders. A slot is visible but there is no possibility of closing slot by ISO surface. In fig. 8 the slot between surfaces is shown. On the contact surface of both cylinders slot of 26 μm is formed (measured at a magnification of 8 μm (fig. 8). While size of the slot at a magnification of 25 μm (fig. 8 is 49 μm. The phenomenon of apparent expansion of slot arises. This happens when the actual size of the slot is smaller than the pixel size. 5. Conclusions Computer tomography allows to perform non-destructive testing of aluminum castings. The study of single cross sections allows detection of the existing pores and inclusions Fig. 8. A cross section view of the slot: with the 8 μm magnification, with the 25 μm magnification (size of single voxel) Rys. 8. Widok przekroju szczeliny: przy powiększeniu 8 μm, przy powiększeniu 25 μm (rozmiar pojedynczego woksel of other materials. Algorithms used to calculate the volume of pores can detect correctly only the largest pores. For the verification correct operation of the algorithms is necessary to build appropriate gauges. Gauges should be constructed so that it is possible to estimate the actual volume of the pores. The study does not consider the influence of sub-pixel effects [7] of the automatically determined value and routes of ISO line. In addition, significant influence on the final result of the calculated pore volume has a value of used magnification. Bibliography 1. Ratajczyk E., Tomografia komputerowa CT w zastosowaniach przemysłowych, Mechanik, nr 2/2011, 112 117; nr 3/2011, 226 231; nr 4/2011 326 331. (in Polish). 2. [www.zeiss.pl]. 3. METROTOM 800. Operating Instructions. Zeiss. 4. Niemelä T., Aydogan D.B., Hannula M., Hyttinen J., Kellomäki M., Determination of bioceramic filler distribution and porosity of self-reinforced bioabsorbable composites using micro-computed tomography, Elsevier, Composites : Part A 42 (2011) 534 542. 5. Khalid A. Alshibili, Bashar A. Alramahi, Attia Mahmoud Attia, Assessment of Spatial Distribution of Porosity in Synthetic Quartz Cores Using Microfocus Computed Tomography (CT), Particulate Science and Technology, 24: 369 380, 2006. Pomiary Automatyka Robotyka nr 12/2012 85

6. Hitoshi Nakayama, Douglas M. Burns, Tomoyuki Kawase, Nondestructive Microstructural Analysis of Porous Bioceramics by Microfocus X-ray Computed Tomography (CT): A Proposed Protocol for Standardized Evaluation of Porosity and Interconnectivity Between Macro-pores, Journal of Nondestructive Evaluation (2011) 30:71 80. 7. Weber E., Fernandez M., Wapner P., Hoffman W., Comparison of X-ray micro-tomography measurements of densities and porosity principally to values measured by mercury porosimetry for carbon carbon composites, Elsevier, Carbon, 48 (2010) 2151 2158. Pomiary porowatości za pomocą tomografu komputerowego Streszczenie: W artykule przedstawiono wyniki badań dotyczące pomiarów objętości porów w odlewach aluminiowych. Badania przeprowadzono na przemysłowym tomografie komputerowym METROTOM 800 firmy Carl Zeiss. Porównano wyniki algorytmów automatycznego i manualnego wykrywania porów w odniesieniu do powierzchni ISO. Do analizy wyników zastosowano oprogramowanie VGStudio MAX. Słowa kluczowe: tomografia komputerowa, porowatość Tomasz Kowaluk, MSc He received the M.Sc. from Warsaw University of Technology in 2011. He is currently a PhD student in the Institute of Metrology and Biomedical Engineering, Faculty of Mechatronics, Warsaw University of Technology. Within the PhD he deals with the porosity of elements from computer tomography. e-mail: t.kowaluk@mchtr.pw.edu.pl Adam Wozniak, PhD, DSc, prof. of WUT He received the MSc (1998), PhD (2002), and DSc (2011) degrees from Warsaw University of Technology, Poland. From 2005 to 2006 he was a Visiting Professor with the Department of Mechanical Engineering, École Polytechnique de Montréal, Canada. He is currently a Professor with the Institute of Metrology and Biomedical Engineering, Faculty of Mechatronics, Warsaw University of Technology. His current research interests include dimensional metrology, especially coordinate measuring technique. He is the author of more than 80 papers in these areas. e-mail: a.wozniak@mchtr.pw.edu.pl 86