AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134



Similar documents
Field Information Manager Product guide. Field Information Manager version 1.1

Grid Automation Products. SAM600 Process Bus I/O System Cyber Security Deployment Guideline

Users manual. TCW181B-CM_R1 Page 1

System 800xA. Released User Documents. Power and productivity for a better world TM. System Version 5.1

Remote Access Platform. Architecture and Security Overview

II Intelligent PC/CAN Interface. Manual

BASLER ACE QUICK INSTALLATION GUIDE

Modbus RTU (RS-485) TCP/IP (Ethernet)

User Manual. EtherUSB

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

EMBEDDED ACCESS CONTROL Hardware Installation Guide

Waveguide Access Point WGA631. Product Guide

Network Interface Panel User s Guide NPD EN

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

Snapshot Reports for 800xA User Guide

UniStream CPU-for-Panel

User Manual PT-E-HIP

Two kinds of size notation are employed in this manual. With this machine refer to the metric version.

Stratix 5700 Switch Configuration

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

AXIS 291 1U Video Server Rack Installation Guide

Stratix 5700 Network Address Translation. Quick Start

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

T7560A,B,C Digital Wall Module

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Daikin Magnitude TM Chiller Unit Controller BACnet Communication Module (MS/TP, IP, Ethernet)

TFTP Firmware upgrade

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

MicroLogix 1100 Embedded Web Server

User Manual. EtherUSB

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

CM400 High Speed Cable Modem User Manual

GV-Data Capture V3 Series User's Manual

Lifecycle Service Tool. Operator's manual

Internet Telephony PBX system IPX-1980

MultiVOIP FX FXS-Only SIP Gateways

M3 ORANGE Snap-On. User Guide. Product Model: A-SNO-ATYP-060-R00. Compatible Device: M3 ORANGE. Version 2.2 Released in March 2013

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

CM500 High Speed Cable Modem User Manual

FOM-5A, 6A. Asynchronous Fiber Optic Modem

Installation and Operation Guide

System System 800xA PC, Network, and Software Monitoring Configuration

Provides one channel for Ethernet over existing

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

WLAN Outdoor CPE For 2.4G. Quick Installation Guide

Application Note FC-Series

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

INSTALLATION GUIDE. AXIS T8133 Midspan 30W

CompactLogix Power Supplies Specifications

Configure Inverter output for two utility settings, (1)120V/60Hz, (2)220V/50Hz

Table of Contents. Creating a VC1000 Network... 3

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Addendum to the Operating Instructions

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

HP UPS R1500 Generation 3

System 800xA PC, Network, and Software Monitoring Operation

Crow Limited Warranty. Print Version 017

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

How To Use A Network Card With A Network Box (Ios) On A Microsoft Powerbook 2.5 (I2) (I3) (Io2) And I2 (Io) (Net) (Ipo) (

Outdoor-Ready Box. Hardware Manual KCM-5211E, KCM-5311E KCM-5511, KCM Ver. 2014/10/15

Box Camera Series Hardware Manual

First Steps. Remote Access Gateway IGW/922. with DIL/NetPC ADNP/9200

M3 Single-Slot Cradle. User Guide. Cradle Model: A-1CR-U R00, A-1CR-U00D-040-R00, A-1CR-US R00, A-1CR-U0ED-110-R00

IP POWER 9258 USER MANUAL IP POWER 9258 USER MANUAL

1-Port Wireless USB 2.0 Print Server Model # APSUSB201W. Quick Installation Guide. Ver. 2A

Sunny Boy Accessories SMA POWER BALANCER

VOIP-2CH. Telephone Clocking Adapter. Installation Guide

M3 ORANGE single-slot Cradle. User Guide. Product Number: A-1CR-US0D-030-R00, A-1CR-U0ED-030-R00. Compatible Device(s): M3 ORANGE

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Port Interface Card Installation and Safety Guide

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

1 Serial RS232 to Ethernet Adapter Installation Guide

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

300Mbps Wireless-N Access Point/Repeater

Configuration Manual English version

PixelController II Art-Net controller for LED pixels

HG659 Home Gateway. User Guide HUAWEI TECHNOLOGIES CO., LTD.

Technical Note. Setting ACS drive IP address automatically with Rockwell BOOTP/DHCP Server. Contents


Security Analytics Engine 1.0. Help Desk User Guide

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

MultiVOIP FX SIP Gateways

JDSU PathTrak. HCU200 Install User s Guide

Installation Guide Wireless 4-Port USB Sharing Station. GUWIP204 Part No. M1172-a

MicroLogix 1400 Embedded Web Server

Protect IT MNS Motor Management INSUM. MPU - Multi Purpose Unit. - Catalogue - ABB

Provides one channel for Ethernet over existing

User Manual. PePWave Surf / Surf AP Indoor Series: Surf 200, E200, AP 200, AP 400. PePWave Mesh Connector Indoor Series: MC 200, E200, 400

Innovative Electronics for a Changing World INDEX

WIZ-Embedded WebServer User s Manual (Ver. 1.0)

TX OPEN RS232/485 module

Medical Vacuum Systems-PXMI

SAGEM TM 1201/1241 V2

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Transcription:

AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN SP1134 Power and productivity for a better world TM

AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN

NOTICE This document contains information about one or more ABB products and may include a description of or a reference to one or more standards that may be generally relevant to the ABB products. ABB may have one or more patents or pending patent applications protecting the intellectual property in the ABB product(s) described in this publication. The presence of any such description of a standard or reference to a standard is not a representation that all of the ABB products referenced in this document support all of the features of the described or referenced standard. In order to determine the specific features supported by a particular ABB product, the reader should consult the product specifications for the particular ABB product. The information in this document is subject to change without notice and should not be construed as a commitment by ABB. ABB assumes no responsibility for any errors that may appear in this document. In no event shall ABB be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, nor shall ABB be liable for incidental or consequential damages arising from use of any software or hardware described in this document. This document and parts thereof must not be reproduced or copied without written permission from ABB, and the contents thereof must not be imparted to a third party nor used for any unauthorized purpose. The software or hardware described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license. This product meets the requirements specified in EMC Directive 89/336/ EEC and in Low Voltage Directive 72/23/EEC. TRADEMARKS All rights to copyrights, registered trademarks, and trademarks reside with their respective owners. Copyright 2003-2010 by ABB. All rights reserved. Release: June 2010 Document number: 3BSE059754R0001

TABLE OF CONTENTS Section 1 - Installation Introduction... 9 Installation Items Checklist... 9 Installation and Operation Requirements... 9 Connectors... 10 Connect Power... 11 Connecting to DeviceNet... 12 DeviceNet Connector... 12 Setting the MAC ID Using the BWConfig Tool... 12 Connecting to Ethernet... 14 Ethernet Connector... 14 Setting the IP Address... 15 Configuration Port Connector... 19 Section 2 - Technical Specifications Environmental Specifications... 21 EMC Directive Compliance... 21 Electrical Specifications... 21 Further Technical Information... 22 3BSE059754R0001 5

Table of Contents 6 3BSE059754R0001

Safety Summary Electrostatic Sensitive Device Devices labeled with this symbol require special handling precautions as described in the installation section. GENERAL WARNINGS Equipment Environment All components, whether in transportation, operation or storage, must be in a noncorrosive environment. Electrical Shock Hazard During Maintenance Disconnect power or take precautions to insure that contact with energized parts is avoided when servicing. SPECIFIC WARNINGS Page 10: Substitution of components may impair suitability for Class 1, Division 2. SPECIFIC CAUTIONS Page 10: When in hazardous locations turn off power before replacing or wiring modules. Page 10: Do not disconnect equipment unless power has been switched off or the area is known to be nonhazardous. 3BSE059754R0001 7

Section 1 Installation Introduction This section describes the installation requirements for DeviceNet Linking Device LD 800DN and the installation procedure. Installation Items Checklist EtherNet to DeviceNet Linking Device LD 800DN. EtherNet/IP DeviceNet Configuration manual (9ARD000014*). Power cable for connection to supplied 2 position connector. DeviceNet cable for connection to supplied 5 position connector. Ethernet cable for connection to RJ45 connector. Installation and Operation Requirements Power, input and output (I/O) wiring must be in accordance with Class 1, Division 2 wiring methods article 501-4 (b) of the National Electric code, NFPA 70 and in accordance with local codes. Terminal tightening torque must be between 5 lbs-in to 7 lbs-in (0,5 Nm - 0,8 Nm). 3BSE059754R0001 9

Connectors Section 1 Installation For use in Class 2 circuits only. Suitable for Surrounding temperature of 65 C max. Use 60/75 C copper wire only. Substitution of components may impair suitability for Class 1, Division 2. When in hazardous locations turn off power before replacing or wiring modules. Do not disconnect equipment unless power has been switched off or the area is known to be nonhazardous. Connectors The following Figure 1 displays the connectors for LD 800DN. 10 3BSE059754R0001

Section 1 Installation Connect Power Figure 1. Connectors for LD 800DN Connect Power The LD 800DN requires 24 V DC power for the 2 position terminal block connector. Figure 2. 24 volts DC power 3BSE059754R0001 11

Connecting to DeviceNet Section 1 Installation Connecting to DeviceNet DeviceNet Connector DeviceNet is connected to the 5 position terminal block connector. Figure 3. DeviceNet Connector A 120 ohm termination resistor (Two pieces included with the product) needs to be placed at the beginning and at the end of the Controller-Area Network (CAN). The termination resistor is placed between CAN High and CAN Low signals. Setting the MAC ID Using the BWConfig Tool The factory default DeviceNet settings are: MAC ID 63. The following are the steps for setting the MAC ID using BWConfig Tool: 12 3BSE059754R0001

Section 1 Installation Setting the MAC ID Using the BWConfig Tool 1. Launch the BWConfig tool, a window is displayed as shown in Figure 4. 2. Edit the MAC Address provided in the DeviceNet Configuration pane and download the configuration to LD 800DN. After the configuration is downloaded, the BWConfig tool will automatically reset the LD 800DN. For complete information on using BWConfig tool, refer to LD 800DN section of EtherNet/IP DeviceNet Configuration manual (9ARD000014*). 3BSE059754R0001 13

Connecting to Ethernet Section 1 Installation Connecting to Ethernet Figure 4. BWConfig tool Ethernet Connector The Ethernet cable is connected to the RJ45 connector at the end of the module. 14 3BSE059754R0001

Section 1 Installation Setting the IP Address Setting the IP Address The following are the various ways of setting ip address for LD 800DN: Setting the IP Address Using the BWConfig Tool. Setting the IP Address with the Configuration Switch. Setting the IP Address Using the Web Page. Setting the IP Address Using the BWConfig Tool The Ethernet configuration can be set using the BWConfig tool. The following are the steps for setting the IP Address using BWConfig Tool: 1. Launch the BWConfig tool, a window is displayed as shown in Figure 4. 2. Edit the IP Address in the Ethernet configuration pane and download the configuration to LD 800DN. After the configuration is downloaded, the BWConfig tool will automatically reset the LD 800DN. For complete information on using BWConfig Tool, refer to LD 800DN section of EtherNet/IP DeviceNet Configuration manual (9ARD000014*). 3BSE059754R0001 15

Setting the IP Address Section 1 Installation Setting the IP Address with the Configuration Switch The IP configuration switch is an 8 position DIP switch located at the end of the module. If any of the 8 switches are in ON position, then the following IP address is set. Table 1. IP addresses IP Address: 192.168.1.n Subnet Mask: 255.255.255.0 Gateway Address: 0.0.0.0 Where n is the value represented in binary by the DIP switch. This address is a private address and can only be used on a local intranet. Example: Figure 5. Switch with Binary Value 16 3BSE059754R0001

Section 1 Installation Setting the IP Address The switch represents the binary value 00010100, or 20 decimal. (The switch position is shown in White in the diagram.) The resulting IP address is 192.168.1.20. This procedure of setting IP address using the Configuration Switch takes precedence over all the other procedures. Setting the IP Address Using the Web Page The IP address can also be configured using the Status and Settings web page. The web pages are accessed by typing the current IP address of the LD 800DN into a web browser URL. The Status and Settings web page appears as shown in Figure 6. 3BSE059754R0001 17

Setting the IP Address Section 1 Installation Figure 6. Status and Settings Webpage The IP address, subnet mask, and default gateway address are displayed in the text boxes on the web page. Edit the IP address values accordingly. Select Submit Values to set the addresses for LD 800DN. A power cycle or module reset is required for the changes to take effect after selecting the Submit Values button. The Reset Module button can be used to reset the LD 800DN from the web browser. The Scanner Mode will display RESETTING... while the module resets and comes back online. The web page is refreshed after the module has booted. 18 3BSE059754R0001

Section 1 Installation Configuration Port Connector If the web browser is configured to cache web pages, it may appear that the LD 800DN has not changed address after the module is power cycled. Ensure that the browsers settings are configured to always reload pages. This can be done on Internet Explorer in the Temporary Internet Files Settings by selecting the Every Visit to the page option. This option enables the browser to check for any changes on the page. Configuration Port Connector The configuration port is the 9-pin D-Subminiature female connector at the end of the LD 800DN. Figure 7 shows the connections to be made. Figure 7. Configuration Port Connector The LD 800DN is connected to a PC for configuration using a null-modem cable. A null-modem cable has pin 2 and pin 3 3BSE059754R0001 19

Configuration Port Connector Section 1 Installation swapped so that Transmit line of the PC is connected to the LD 800DN Receive line, and Receive line of the PC is connected to the LD 800DN Transmit line. The LD 800DN does not use the modem control signals specified for a DTE connector. Connecting the module through devices, such as isolation modules, which assume control of these lines may result in unreliable BWConfig communication. 20 3BSE059754R0001

Section 2 Technical Specifications Environmental Specifications Operating Temperature: 0 C to 65 C. Non-Operating Temperature: -25 C to 85 C. EMC Directive Compliance This product is tested to meet the Council Directive 2004/108/EC Electromagnetic Compatibility (EMC) by applying the following standards, in whole or in part, documented in a technical construction file: EN61000-6-4-EMC Generic Emission Standard for Industrial Environment. EN61000-6-2-EMC Generic Immunity Standard for Industrial Environment. This product is intended for use in an industrial environment. Electrical Specifications Power Supply: 12 VDC - 30 VDC. Current Requirements: 130 ma - 140 ma at 24 VDC. 3BSE059754R0001 21

Further Technical Information Section 2 Technical Specifications Further Technical Information For further technical information on LD 800DN, refer to EtherNet/IP DeviceNet Configuration manual (9ARD000014*). 22 3BSE059754R0001

Contact us ABB AB Control Systems Västerås, Sweden Phone: +46 (0) 21 32 50 00 Fax: +46 (0) 21 13 78 45 E-Mail: processautomation@se.abb.com www.abb.com/controlsystems ABB Inc. Control Systems Wickliffe, Ohio, USA Phone: +1 440 585 8500 Fax: +1 440 585 8756 E-Mail: industrialitsolutions@us.abb.com www.abb.com/controlsystems Copyright 2003-2010 by ABB. All Rights Reserved 3BSE059754R0001 ABB Industry Pte Ltd Control Systems Singapore Phone: +65 6776 5711 Fax: +65 6778 0222 E-Mail: processautomation@sg.abb.com www.abb.com/controlsystems ABB Automation GmbH Control Systems Mannheim, Germany Phone: +49 1805 26 67 76 Fax: +49 1805 77 63 29 E-Mail: marketing.control-products@de.abb.com www.abb.de/controlsystems Power and productivity for a better world TM