COMPLEXITY SIMPLIFIED SIMPLEX FAMILY BROCHURE PANELS, DETECTORS & ANCILLARIES



Similar documents
SIMPLEX FIRE DETECTION AND ALARM SYSTEMS

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

TrueAlarm Fire Alarm Systems

Intelligent Fire Detection & Alarm and Mass Notification System.

Building Solutions. One Honeywell Solution for All of Your Fire Systems Needs

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

Faraday Intelligent Fire Detection Systems

NETWORKING AND INTEGRATION

City of Bettendorf Fire Alarm System Requirements

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

Fire detection equipment

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

TrueAlarm Fire Alarm Systems

IP-Based Communications Solutions

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

Life safety solutions. protecting every single asset

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

DTW Works Master Specification Version 2006

The ONYX Series. The Ultimate in Fire Protection Technology

Simplex Fire Products Corporate Profile

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

SECTION FIRE ALARM AND DETECTION SYSTEM

MM8000 safety and security with smart danger management. A scalable and flexible management station for any requirement. Answers for infrastructure.

I N T E L L I G E N T F I R E A L A R M C O N T R O L S Y S T E M S

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

Fire Control Panels. Addressable Fire Detection and Control Emergency Voice/Alarm Communications Equipment

TrueAlarm Fire Alarm Systems

MINERVA MX MX Virtual Multi-Sensor Detectors

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

SECTION FIRE ALARM AND DETECTION SYSTEMS

Overview of Fire Alarm Systems and Maintenance

Reliable Security Solutions

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution

Fire Alarm FAQs. Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need?

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction

SECTION DETECTION AND ALARM

EXHIBIT A SCOPE OF WORK

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

University Design Standard. Fire Alarm Systems

Panels, detectors & ancillaries

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Voice alarm system E100 the new standard for safe evacuation

STATE-OF-THE-ART FLAME, SMOKE AND INTRUSION VIDEO DETECTION TECHNOLOGY FIRE DETECTION AND VIDEO SURVEILLANCE

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

Power & Environmental Monitoring

Module 4, Lesson 12 Fire Alarm Systems

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

Analogue addressable devices

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply

SECTION FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

SECTION FIRE ALARM SYSTEM

CenterMind G+ Smart and Proactive Environment Monitoring

Fire Alarm and Detection Systems And Central Station Monitoring Plan Submittal Guidelines

Bold items are particular to the City of Euless

Versatile. EST3X Life Safety Solutions. An EDWARDS brand.

The Mission Critical Fire Protection Experts

Notification Solutions Campus

Early Warning Fire Detection and Integrated Security Solution. System Overview

Life Alarm Fire Alarm Controls

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

FIRE ALARM SYSTEM RECORD OF COMPLETION

Fire Station Alerting and Automation

1.0 General. Inspection, Testing, and Maintenance 1 of 8


SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

FIRE ALARM SYSTEM RECORD OF COMPLETION

Square D Powerlink G3 Lighting Control Systems

Module 5. Fire and Emergency Alarm System Part I- Basics

Conventional Fire Detection and Extinguishant Control System Specification

UniFireNet Facilities Monitoring System MEA GENERAL NETWORK FEATURES

PURVIS Fire Station Alerting System

SECTION FIRE ALARM AND DETECTION SYSTEM

Comprehensive Data Center Energy Management Solutions

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

2012 Ontario Building Code Changes Affecting Fire Alarm Systems

C. Conform to requirements of Americans with Disabilities Act (ADA).

SFC-200 SERIES LCD FIRE ALARM PANEL

PLAN REVIEW GUIDE FOR FIRE ALARM

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Personna PC web-based software. Q-AdminTM client. Lighting management hub (floor 1)

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007

Fire Station IP Alerting System

FIRE. 4100U Fire Alarm. Operator s Manual. Operator's Manual. Operator s Manual. LT0395 Iss 1.0

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Comprehensive Data Center Energy Management Solutions

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S :111

Local SecurityNetwork We know what it s all about

Fire Alarm System Plans Review Checklist Property location Date of Review

SOLUTION BRIEF. Motorola FSA4000. How to Achieve Near 100% Fire Station Alerting Reliability

Integrating fire alarm systems with building. Fire Alarm Systems with Building Automation and Control Systems INTEGRATING INTRODUCTION

FAAST. Fire Alarm Aspiration Sensing Technology

Transcription:

COMPLEXITY SIMPLIFIED SIMPLEX FAMILY BROCHURE PANELS, DETECTORS & ANCILLARIES

About SIMPLEX Founded in 1894, Simplex is the world s premiere manufacturer of fire and security products with more than 10 decades of history. During January 2001, it was merged with Tyco to become a member of Tyco International Ltd. Tyco International Ltd. is a multinational cooperation that operates in a variety of businesses. As a core operating sector of Tyco International Ltd., Simplex has achieved their goal in helping Mainland China, Taiwan, Hong Kong, India, Malaysia, Singapore, Indonesia, Vietnam, Thailand, South Korea, Philippines, Japan and many other countries and regions with their fire safety and fire systems. Thousands of our engineers provide system planning and secondary design, on-site installation instruction, system debug and other pre-sales and after-sales services for different buildings and various application requirements in more than 90 countries around the world, in order to meet all of the customers needs. While delivering state-of-the-art Life Safety Solutions, we always keep our sights set on providing easy migration paths to future technologies. We develop our products to be backward/forward compatible, helping to ensure a long life for our solutions and products, providing on-going operational efficiency and investment protection for our customers. Everything we do revolves around an approach to life safety that aligns today s thinking with the forethought and flexibility needed for the future. 2

A NEW WAY TO MANAGE YOUR SAFETY AND YOUR FUTURE Master Bay System Power Supply (SPS) with onboard IDNet channel, 3 NAC s and Aux Power. CPU, Network Card, Media Cards, RS232 Expansion Bays Dual redundant CPU option for critical applications such as Fire & Gas Systems Audio Firefighter phones Relays Cards, Zone Cards, IDNet Cards LED / Switch modules TCP/IP Physical bridge Single Fibre Modems Expansion Power Supplies (XPS) TrueAlert Power Supplies LIFECYCLE investment protection MIGRATION PATH to tomorrow s technology MISSION protection, risk avoidance INTERNET connectivity SCALABLE, OPEN SYSTEMS environment INFORMATION MANAGEMENT INTELLIGENT devices INTUITIVE user interface KEY FEATURES UL / FM Approved Universal Platform Small to large systems New processor with on board IP Network Capability and compact flash Future Proof Modular Design Backward compatibility and upgrade path to new technologies to protect customer s investment Integrated Voice Alarm & Fire Fighter Phones Agency Listed Non Alarm Audio (Paging and Background Music) Spoken Walk Test Voice Coding / Message Splicing Smoke Management & Control High Level Networking, Multiple Topologies and Connectivity Options Third Party Open Protocol Interfaces such as BACNet, Modbus and OPC Server Graphic command centers with client server and dual redundant configurations. SafeLINC Fire Panel Internet Interface UL / FM Listed for Suppression Release Master Clock Interface Tyco CCure Security Access Control Intergration TrueInsight Remote Service LISTING UL864 9th Edition, ULC and FM CCCF China BSMI Taiwan HKFSD Hong Kong BOMBA Malaysia KOFFEIC Korea 3

4100 ES EMERGENCY VOICE/ ALARM 4100ES Audio Systems 4100ES Audio Systems provide voice communication, alarm tones, and/or digitally pre-recorded voice messages to alert occupants of fire or other emergency situations. Evacuation signalling may be automatically generated via alarm initiated event programs or by fire fighting personnel using the operator controls. Firefighter Telephone Systems: Firefighter telephone systems provide two-way communications for facilities where radio communications may not be available or are unreliable. They are typically used during active fire fighting conditions, during a fire alarm investigation, or during fire alarm system inspection and test. Master telephone can simultaneously talk with up to 6 remote telephones and can be connected as an audio input for broadcast messages. Degraded mode allows remote telephones to remain connected to each other in the event of a communications loss. Emergency Voice/Alarm Communications Provide: Alarm/evacuation signal generation with multiple built-in tones. Standard or customised digital message storage and message generation. Automatic or manual operation. Mass Notification operation. Analogue audio systems provide dual channel operation. Digital audio systems provide multiple channels over a single wire pair. Supervised remote microphone inputs. Spoken voice coding from the digital message player. Multiple digitally recorded human voice messages. Spoken WALKTEST system testing. Separate evacuation, drill, and optional All Clear voice messages and tones. Ready-to-talk microphone indicator on front panel audio control module. Local panel speaker for tone/message broadcast verification. MINIPLEX Voice Integrated Voice Alarm Systems provide Clear Concise Instructions for safe and effective alert and evacuation procedures including unobtrusive maintenance and testing. Campus Style Network Multiple Connectivity Options Central Security Office Building Simplex 4100ES NVCC Network Voice Command Centre Hardwire Fibre or TCP/ IP connectivity Optional BMS Interface Bacnet TCP/IP Administration Building TCP/IP Command Line Interface LAN CCUVE/ 4100MB CCU3/ E/4100 Client/ Server Graphic Command Centre CCU3/E/HUB MODBUS Master XL Graphic Client/Server OPC Alarm and Event Server Library 4

SIMPLEX FIRE ALARM NETWORKS: Simplex Fire Alarm Networks communicate information among distributed Simplex fire alarm control panels. Systems may be composed of similar capability panels sharing information, or specific nodes may be added to perform dedicated network functions. Illustrations on the following pages provide a summary of a variety of fire alarm Network applications, multiple topologies and connectivity options. For non-simplex panels, a Network System Integrator can be used to connect equipment to the Network using optically isolated inputs and relay contact outputs. Network communications among system fire alarm control panels provides: Support for Network Emergency voice broadcasts and Centralised Command Center operations Multiple Network Loops for campus and other high panel quantity applications Network-wide initiation of alarm silence, acknowledge, and reset; and investigation of status and details of system points and point lists Distributed system operation to ensure excellent survivability; during a communications fault condition, Network nodes remaining connected will regroup and continue communicating Flexible Network Annunciator options such as XLGraphics, TrueSite Workstations, Network Display Units (NDU) and NDUs with VCC (Voice Command Center) Use of InfoAlarm Command Center equipped nodes to provide increased network information display capability Network level command and control provides manual point control for on/off or disable/enable, as well as gathering specific point detail Network & Audio Riser in one single mode fibre Conventional Panel Arts Building Science Building Caretaker Acommodation LAN One single mode fibre 32 km between nodes Remote Client Graphic Command Centre NSI Network System Integrator Staff Accommodation Sports Pavilion Alarms (Fire & Security) / Troubles / Supervisory Maintenance / Emergency Paging / Dispatch Aid 5

BOOST VALUE AND PERFORMANCE WITH ADVANCED PERIPHERALS Our advanced options and peripherals are designed to ensure compatibility and to work seamlessly with all our fire alarms platforms. These devices and peripherals can help you meet applicable codes and seamlessly enhance system configuration as needs change. Modular design and consistent user interfaces are built into every system and peripherals from Simplex, allowing you to leverage your investment far into the future. TrueAlarm /Analog Smoke And Heat Sensors The First Choice In Intelligent Sensing Technology /analog for full interactive communications Intelligent sensing for reduced nuisance alarms Lower installation and expansion costs Automatic adjustment for dirt, dust, humidity and aging- our sensors even tell you when they need to be cleaned Four available options: Photo, Ion, Heat or Multi-sensor Photo/ Heat combining smoke/heat in a single base that s easy to wire and allows each sensor to be programmed individually TrueAlarm Non- Smoke and Heat Detectors Advanced Technology In A Non- Detector Photogenic detector incorporates an onboard microprocessor for auto drift compensation Self restoring heat detectors leverage fast-response thermistor technology Nuisance alarm prevention TrueAlert Notification Appliances Intelligent Fire Notification For The 21st Century Global addressability and synchronisation supporting full interactive communications Lowest installed cost in the industry Smart system with TrueAlert Isolators automatically identifies and isolates its own short circuits faults. Low retrofit costs you can use existing installed wiring when upgrading TrueAlert appliances for a different alarm response (heat or smoke), or combines for faster response to fast-flaming fires. For companies seeking the lowest possible installations and maintenance costs For operations requiring detailed maintenance and alarm reporting to the device level Built-in sensitivity testing to reduce maintenance cost Ideal solution for non-addressable and legacy fire alarm environments, small facilities Perfect for new constructions, retrofits or expansion Ideal in facilities where disrupting operations testing is acceptable Mass notification control TrueAlert Non- Multi-candela Notifications Appliance Exceptional Performance With Fast, Convenient Installation Installs quickly and easily, features lower current draw SmartSync feature allows individual control of audible and visible appliances on a single non-addressable circuit, reducing equipment and installation costs For any fire system with basic audible/visible evacuation needs Flexibility to adapt to occupancy changes Simplex TrueSite Information Management Systems Vital Management Information Right At Your Fingertips Family of Windows-based agency-listed management solutions Provides state-of-the-art 4100ES network annunciation, configuration and control consumption reporting AVAILABLE FEATURES Remote Clients agency-listed primary operator management workstation with LAN/WAN remote terminals Universal panel Interface agency-listed interface links existing non-simplex panels to IMS A must have management tool for companies that have their own fire response team or that manage their own 4100ES fire alarm networks Excellent for large-scale network environments, such as multi-building campuses and towers One work station for all fire alarms system 6

THE POWER OF ADDRESSABILITY Reduces maintenance and testing costs Lowering installation costs Pinpoints event locations for instant response Reduces nuisance alarms SITE 3 Ethernet LAN Simplex SafeLINC The First Agency Listed Email/Internet Solution To Access Fire Detection Systems An innovative solution for interfacing 4100U Universal Fire Alarm Platforms to the owner s secured Internet network View fire panel details remotely, saving time and labour For facilities that require economical fire systems remote access Agency-listed interface to local networks Email notification and periodic reports IDNet Devices Intelligent Devices For Easy Manageability, Lower Operational Costs Family or robust addressable detection and control devices pull stations, monitors and control devices, heat detectors, smoke detectors and more Provides interfaces to other systems, such as sprinklers or HVAC, for facility-wide monitoring and control Converts non-addressable devices into addressable functionality Provides isolators for higher system and network reliability Ideal for new construction, retrofits or expansion and Non-addressable 4009 Notification Appliance Circuit Extenders (NAC) Intelligently Expands Notification Capacity Of Any Fire Alarm System Family of smart extenders an excellent low-cost option for expanding notification for both addressable and nonaddressable systems Provides and enhances troubleshooting diagnostics and options for monitoring and notification of remote buildings For addressable systems: 4009 TrueAlert Controller Simplex TrueAlert Emergency Visual Messaging Display First-Ever Ul-listed Text Message Appliance Manage emergency events with new technology for communicating critical information via text messaging on visual display units Communicate a clear, concise message that directs people where to go and what to do Communicate general, non-emergency messages during nonalarm periods TrueAlert Amber Alert Notification Appliance Advanced Emergency Communications Solution This non-fire emergency device is differentiated from a fire emergency device by the amber lens sand ALERT lettering Easy to modify custom programming activates amber alert strobes or fire strobes; strobes are NOT activated simultaneously Control candela settings through software or hardware Four candela settings: 15, 30, 75, 110 For non-addressable systems: 4009 IDNet Notification Appliance Circuit Extender Ideal for new construction, upgrades and facilities that require compliance with ADA Ideal for campus environments, schools, hospitals, factories, train stations, airport terminal, office buildings and other locations to notify and instruct people in the event of an emergency Available in addressable and non-addressable versions Ideal for military facilities, campus environments, schools, hospitals and other locations with emergency communication systems 7

CAUTION DISCONNECT POWER BEFORE SERVICING FIRE PULL DOWN ALARM 1 + 24V ZONE PWR + 5 2 0V ZONE PWR - 6 3 +IDNET IDC + 7 4 - IDNET IDC - 8 1 5 2 6 3 SIMPLEX TIME RECORDER CO. 7 4090-9101 MONITOR ZAM, CLASS B INSTAL. INSTR. 574-183 4 DATE CODE: 8 1 FIRE ALARM SYSTEMS APPLICATIONS Photo Detector Standard Base Heat Detector Standard Base Photo & Heat Standard Base Detector with Sounder Base Multi Sensor CO Base Multi Sensor CO with Sounder Base Loop supports up to 250 Devices of any mix of detectors or s e.g. 249 Photo Sensor and 01 set of Input TrueAlert Notification Devices Detector with Fault Isolator Base Duct Detector XAD Aspirating Detection Systems Lasercompact VESDA Room 1 Room 2 Detector with Remote LED Connection Detector with Relay Base for Local dry contact Interface Detector with Fault Isolator Base Single Input Zone Single Supervise Input Single Relay Output Single Input Single Relay Output 04 Input & 02 Relay Output TrueAlert Notification Devices Flow Switch Tamper Switch Feedback of Fan Status with Start/Stop Interlock Control Where there is a need for single non supervised and single relay output with one address Where a combination of multiple input and output relay needed from one interface module and address TrueAlert Notification Devices Signal Supervised Signal Supervised Single Ray Fault Isolator 4-20 ma input interface e.g. Gas Detectors, Flame Detectors...etc Dual input releasing for Gas. Water...etc Notification Zones Speaker Zones For dry contact interface or for control start stop of equipment TrueAlert Notification Devices Fault Isolator PullStation Message Display (Maximum 5 per loop) TM 4009 IDNet NAC EXTENDER Up to 8 NACs 4009 IDNet NAC Extender F I R E F I R E Optional IDNet Channel Repeater F I R E F I R E 8

Fewer Nuisance Alarms Greater Peace Of Mind The challenge Minimse danger from smoke, fire, water and other potential hazards Prevent costly property damage Reduce nuisance alarms Lower maintenance costs The first job of any sensor is to protect your operation. The second is to reduce nuisance alarms. Because these alarms are more than just a nuisance. They create costly downtime, disrupt occupants and create unnecessary danger and confusion. Which is why you need TrueAlarm. TrueAlarm s patented technology addresses the major causes of nuisance alarms dirty and overly sensitive sensors fluctuating environmental conditions with a host of powerful, innovative features: Drift compensation Sensors evaluate environmental data and compensate for contamination to maintain detector sensitivity and nuisance alarm immunity. Automatic sensor cleaning indication Warns system operators that a sensor is dirty before its drift compensation level has been reached. Seven UL-approved sensitivity levels Each sensor can be set at a maximum sensitivity for the environment it protects, right down to 0.2%. Peak value logging Provides an historical accounting of how close its sensors have come to its alarm point, allowing you to more accurately set your system for maximum sensitivity without triggering nuisance alarms. obscuration (u.l. window) 4.0% 3.5% 3.0% 2.0% 1.5% 1.0% 0.5% 0.0% Selected Sensitivity 4.0% 3.5% 3.0% 2.0% 1.5% 1.0% 0.5% 0.0% Selected Sensitivity Dirt 4.0% 3.5% 3.0% 2.0% 1.5% 1.0% 0.5% 0.0% Selected Sensitivity Dirt 4.0% 3.5% 3.0% 2.0% 1.5% 1.0% 0.5% 0.0% Selected Sensitivity Dirt alarm level zero reference TrueAlarm sensors are engineered to maintain their present levels of sensitivity. As dirt accumulates, the sensors self-adjust, notifying operators of Almost Dirty, Dirty and Excessively Dirty conditions long before they trigger a nuisance alarm. This lets you schedule maintenance on both Dirty and Almost-Dirty sensors at the same time, minimising your facility costs. 9

True Alert Notification FIRE ALERT STAIRWELL Remote TPS Fifth Floor TrueAlert Channel 2 Fourth Floor Third Floor Second Floor First Floor TPS Ground Floor TrueAlert Channel 1 When controlled from a Simplex 4100ES control panels with TPS, additional features are available such as software selection strobe intensity, detailed reports of actual appliance intensity selection, TrueNAC voltage drop diagnostics and additional setup and test diagnostics. TrueAlert Advantage TrueAlert Operation provides separate audible and visible appliance control functions using a single twowire circuit that also confirms connection to the individual notification appliance s electronic circuit. This operation increases circuit supervision integrity by providing supervision beyond the appliance wiring connections. Opportunities for Reducing Installation and Testing Time Separate controls carried on the same two-wire SLC can significantly reduce installation time and expense for both retrofit and new construction. When Class B (Style 4) wiring is used, wiring can be T-tapped, allowing even more savings in distance, wire, junction boxes, and overall installation efficiency. The extensive diagnostic features available provide improved installation efficiency. 10

Simplex TrueSite Workstation Next-generation platform manages an entire fire and life safety network from a single location Enhanced Protection In Networked Environments In today s multi-building, high-rise and campus environments, life safety is a top-of-mind concern. The protection of people, property and assets can hinge on the ability to quickly respond to an emergency and effectively manage system information from a central command center. With these challenges in mind, Simplex introduces the Simplex TrueSite Workstation an advance, next-generation life-safety information management system developed specifically for large, network installations. The TrueSite system can provide an outstanding life-safely information management solution in commercial facilities, hospitals, colleges, airports, and other demanding environments. A Powerful Platform For Centralised Management When it comes to managing the wide array of information that drives a large fire alarm network, the TrueSite systems stands out for its power, flexibility and ease of use. A PC-based graphical command center that runs on Microsoft Windows, WP, the TrueSite station can seamlessly accept and process information from literally thousands of detectors, notification appliance and other network devices, the system s power is evident in its ability to: Monitor and control up tp 50,000 fire alarm devices Support four network loops and as many as 396 panels Monitor any brand of control panel using agency-listed digital alarm communicators Store historical data for up to 500,000 events Fast Emergency Response And Notification The TrueSite station has been designed to support fast, efficient response to emergency situations. In an emergency, TrueSite receives incoming data from system devices and then automatically provides operators with color-coded action messages, detailed, easy-to-read site and floor plans, and stepby-step instructions on how to respond to the specific condition. The TrueSite workstation supports dual screens monitoring and dockable windows. These features allow simultaneous display of graphical and textual alarm data, giving system operators added ability to quickly assess system activity and respond rapidly and accurately to an emergency. Product Benefits: Strengthen protection of life and property through centralised life safety information management Help accelerate emergency response and control training costs with intuitive graphical interface and event-specific operator instructions Improve operational efficiency through quick access to information and customisable menus Protect your investment and prepare for the future with forward-backward compatibility TrueSite Incident Commander: TrueSite Workstation Power built into your Fire Alarm Panel TrueSite Incident Commander takes all of the leading edge features of a TrueSite Workstation and delivers them in a spacesaving package that mounts in a Simplex 4100ES fire alarm control panel cabinet. Ready for today and tomorrow Keeping with our commitment to stand by our customers and maximise the value of their life safety investments, TrueSite can meet today s needs and carry your system into the future. Our earlier generation GCC and IMS workstations can be easily migrated to TrueSite. What s more, TrueSite features forward - backward compatibility with Simplex products, and has been specifically designed to facilitate system expansions and upgrades. Not only does this bring a high degree of expandability to the fire alarm network, it also provides the framework to help meet emerging life safety and mass notification needs. The TrueSite system is further distinguished by its exceptional survivability. Unlike some other systems, the TrueSite workstation operates as an actual node on the network. This architecture has an advantage of providing true peer-to-peer linkage with all panels on the network, thereby fortifying the TrueSite system s ability to continue operations even if a catastrophic event cripples other parts of the network. High-resolution color graphics with newly enhanced color graphical user interface features, the TrueSite workstation provides touch-screen or mouse-driven access to all system control features. It can import graphic building site plans and graphically display fire, emergency, supervisory, and trouble conditions occurring along the network. Higher screen resolutions provide additional space for detailed graphics. Plus, pan and zoom technology makes it easier to zoom in on a specific point of interest, helping to meet unique customer applications and fulfill market-specific requirements. 11

Singapore Tel : +65 6577 4360 Fax : +65 6481 8791 E-mail : info.apac@tycofp.com India Tel : +91 22 6628 6628 Fax : +91 22 6628 6650 E-mail : info.india@tycofp.com Form No. S-FAM BRO 201211-01 Simplex, Tyco, TrueAlarm, TrueAlert, TrueSite and any other product names listed above are marks and/or registered marks. Unauthorised use is strictly prohibited.