MANUAL PLATELET COUNT



Similar documents
MANUAL PLATELET COUNT

MANUAL WBC LAB OBJECTIVE

Preparation of Blood Films

STAINING OF PBF AND INTERPRETATION OF NORMAL AND ABNORMAL RED CELL MORPHOLOGY

Pre-Lab Questions. 1. What is cell theory? 2. What do all cells contain? 3. What is a prokaryote? 4. What is a eukaryote? 5. What is an organelle?

Minimal residual disease detection in Acute Myeloid Leukaemia on a Becton Dickinson flow cytometer

GIEMSA STAIN PREANALYTICAL CONSIDERATIONS

Human Free Testosterone(F-TESTO) ELISA Kit

STEP-BY-STEP INSTRUCTIONS FOR INVESTIGATIONAL USE. Rapid HCV Antibody Test FOR ORAQUICK RAPID HCV ANTIBODY TEST

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

Calibration of Volumetric Glassware

BACTERIAL ENUMERATION

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA

6 Body Fluid Stains and Standards

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

ABORhCard. ABORhCard Package Insert ABO and Rh Blood Grouping Device

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit

ABO-Rh Blood Typing With Synthetic Blood

LESSON ASSIGNMENT. Collection of Blood and Preparation of Blood Smears. After completing this lesson, you should be able to:

LABORATORY 2 Staining and processing of blood parasites Differential counts of leukocytes (giemsa stains)

RPCI 004 v.002 Staining Procedure For all Directly Conjugated Reagents (Whole Blood Method)

serology Agglutination Techniques and Blood Cell Identification

ABO-Rh Blood Typing Using Neo/BLOOD

How to safely collect blood samples from persons suspected to be infected with highly infectious blood-borne pathogens (e.g.

Western Blotting For Protein Analysis

STEMCELL Quality Control Kits

Lab 02: Blood Cytology (20 points)

Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method)

UltraClean Forensic DNA Isolation Kit (Single Prep Format)

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY. STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 079 MOD: 1st Issue Page: 1 of 7

Ficoll-Paque PREMIUM Ficoll-Paque PREMIUM Ficoll-Paque PREMIUM 1.073

WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Standard Operating Procedure (SOP)

Related topics: Application Note 27 Data Analysis of Tube Formation Assays.

ab StayBlue/AP Plus Stain Kit Instructions for Use An immunohistochemical chromogen substrate for staining tissue sections

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

ArtisanLink Staining System is an automated special stains slide

Enumeration and Viability of Nucleated Cells from Bone Marrow, Cord Blood, and Mobilized Peripheral Blood

Urinalysis and Body Fluids CRg

Animal & Plant Cell Slides

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #:

OSMOSIS AND DIALYSIS 2003 BY Wendy Weeks-Galindo with modifications by David A. Katz

Product name Company Cat # PowerPac Basic Power supply Bio Rad Mini Protean electrophoresis system Mini trans blot cell Bio Rad

VENOUS BLOOD COLLECTION

Promoting safer use of injectable medicines

1. Preparing thin and thick blood films with capillary or venous blood

BD Trucount Tubes IVD

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

HISTOLOGY LABORATORY. Microscope Orientation and Blood Smear Lab

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.

n/a MYSTERY OF THE BLOOD STAIN (RE)

Absolute counting using flow cytometry. Bright Count Microspheres

Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma

In order to be useful, a smear must have the following qualities:

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Where is Mitosis Most Common in the Onion Root?

EXERCISE 3: SKIN PUNCTURE ON INFANTS

Objectives At the completion of this module, unlicensed assistive personnel (UAP) should be able to:

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

protocol handbook 3D cell culture mimsys G hydrogel

Exercise 2. The Compound Light Microscope

Cold Agglutination Titer detecting Cold Reacting Antibodies

Mouse krebs von den lungen 6 (KL-6) ELISA

MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL

Color, True and Apparent

Explain the role of blood and bloodstain patterns in forensics science. Analyze and identify bloodstain patterns by performing bloodstain analysis

Phosphorus, Reactive (Orthophosphate)

Lab 5: DNA Fingerprinting

Canine Creatine Kinase MM isoenzyme(ck-mm) ELISA. kit

MALARIA PARASITE COUNTING

Color, True and Apparent

Running protein gels and detection of proteins

STANDARD OPERATING PROCEDURE

Genomic DNA Purification Student Laboratory Manual

Cell Biology Prokaryotic and eukaryotic cells

INSTRUCTIONS FOR USE

Reagents Quantity Reagents Quantity. Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4. Standard 2 Standard Diluent 1 20mL

COMPARING PLANT AND ANIMAL CELLS

Esterification Method 1 Method to 2800 mg/l (as acetic acid) Reagent Solution

Whole Blood Flow Cytometry

Hematology Morphology Critique

Hematology Sequence. Blood Labs ORIENTATION OBJECTIVES. c. Microscopic Exam of a Peripheral Blood Smear (several parts)

Wizard DNA Clean-Up System INSTRUCTIONS FOR USE OF PRODUCT A7280.

Wall Mount Installation and Use

Dusted! PROCESS SKILLS SCIENCE TOPICS VOCABULARY

HiPer RA Test Teaching Kit

Rat Creatine Kinase MB Isoenzyme (CKMB) ELISA

Calibration of Volumetric Glassware

Collection Guidelines for Routine & Special Coagulation Testing

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure

FerroVer Method 1 Method to 3.0, 1.0 to 30.0 and 10.0 to mg/l Fe Powder Pillows

For in vitro preparation of human mononuclear cells from peripheral blood, bone marrow, and umbilical cord blood. Not for in vitro diagnostic use.

Instructions. Torpedo sirna. Material. Important Guidelines. Specifications. Quality Control

Immunoglobulin E (IgE) concentrations in Human. Immunoglobulin E (IgE) Human ELISA Kit

Fading Red Tones on Color LaserJet 2600s

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

Lab Exercise 3: Media, incubation, and aseptic technique

Measuring Cell Viability/Cytotoxicity: Cell Counting Kit-F

Transcription:

MANUAL PLATELET COUNT Principle Whole blood is diluted with a 1% ammonium oxalate solution. The isotonic balance of the diluent is such that all erythrocytes are lysed while the leukocytes, platelets, and reticulocytes remain intact. 1,2 The standard dilution for platelet counts is 1:100. This dilution is prepared using the leukocyte/platelet Unopette system. 1 The dilution is mixed well and incubated to permit lysis of the erythrocytes. Following the incubation period, the dilution is mounted on a hemacytometer. The cells are allowed to settle and then are counted in a specific area of the hemacytometer chamber under the microscope. The number of platelets is calculated per µl (x 10 9 /L) of blood. Reagents and Equipment 1. Two leukocyte/platelet Unopette reservoirs; each containing 1.98 ml of the following diluent: Ammonium oxalate 11.45 g Sorensen s phosphate buffer 1.0 g Thimerosal 0.1 g QS with distilled water to 1 liter 2. Two Unopette capillary pipets, 20 µl 3. Hemacytometer with cover glass 4. Petri dish with filter paper 5. Hand counter 6. Microscope Quality Control Commercial quality control materials with established control limits should be run periodically. The frequency is determined by each laboratory's workload. For instance, quality control material may be run at the beginning of each eight-hour shift. Specimen Whole blood, anticoagulated with EDTA, or free-flowing capillary blood may be used.

Procedure 1. Prepare two leukocyte/platelet Unopettes as a. Using the protective shield on the capillary pipet, puncture the diaphragm as 1) Place reservoir on a flat surface. Grasping the reservoir in one hand, take the pipet assembly in the other hand and push the tip of the pipet shield firmly through the diaphragm in the neck of the reservoir, then remove. b. Remove the shield from the pipet assembly with a twist and fill the capillary pipet with whole blood. Transfer the whole blood to reservoir as 1) Wipe excess blood from the outside of the capillary pipet, making certain that no blood is removed from the capillary bore. 2) Squeeze the reservoir slightly to force out some air. Maintain pressure on the reservoir. 3) Cover opening of overflow chamber of the pipet with your index finger and seat the pipet securely in the reservoir neck. 4) Release pressure on the reservoir. Then remove your finger from the pipet opening. Negative pressure will draw the blood into the diluent. 5) Squeeze the reservoir gently two or three times to rinse the capillary bore, forcing diluent into, but not out of, the overflow chamber, releasing pressure each time to return the mixture to the reservoir. 6) Place your index finger over the pipet opening and gently invert several times to thoroughly mix the blood with diluent. 7) Let stand for 10 minutes to allow erythrocytes to hemolyze. 2. Clean the hemacytometer and cover glass by flooding them with 70% alcohol. Dry thoroughly with gauze or tissue; do not allow the alcohol to dry on the hemacytometer. Be sure to remove all lint. Place the cover glass in position over the ruled area. 3. Following incubation, mix diluted blood thoroughly by inverting reservoir to resuspend cells. Charge hemacytometer as a. Convert to dropper assembly by withdrawing the pipet from the reservoir and reseating it securely in its reverse position. b. Clean the capillary bore by inverting the reservoir, gently squeeze the sides, and discard the first three or four drops.

c. Place the pipet tip on the edge of the ruled area of the counting chamber. Carefully charge the hemacytometer with diluted blood by gently squeezing the sides of the reservoir to expel the contents until the chamber is properly filled. d. Repeat procedure to charge the other side of the hemacytometer with the first Unopette reservoir. e. Place the hemacytometer on moistened filter paper in a Petri dish, and allow to stand 10 minutes to permit the cells to settle. f. Using this same procedure, charge a second hemacytometer with the second Unopette reservoir. 4. Carefully place the hemacytometer on the microscope stage. Perform cell count as Calculations a. With the low-power (10x) objective, locate the ruled area and the center large square (1 mm 2 ). Examine the entire center square for even distribution of platelets, then carefully switch to the high-dry-power (40x) phase objective for counting platelets. With phase microscopy, platelets appear as round or oval bodies. b. Platelets are counted in the entire center large square (1 mm 2 ) (Figure 7-7) as 1) Count the platelets in the first row of squares going from left to right, then from right to left in the second row; follow this pattern until all rows are counted. 2) Within each square, count all platelets touching the top and left-hand borders. Do not count any cells touching the bottom or right-hand borders. 3) Use the fine adjustment knob to focus up and down to identify the platelets. c. Repeat this counting procedure for the other side of the hemacytometer. d. Record the counts for each center square. The difference between these two counts should not exceed 10%. e. Count the platelets on the second hemacytometer following the above counting procedure.

1. The calculation formula for hemacytometer cell counts determines the number of cells within 1 µl (1 mm 3 ) of blood (Figure 7-9). To make this determination, the total number of cells counted must be corrected for the initial dilution of blood and the volume of diluted blood used. The standard dilution of blood for platelet counts is 1:100; therefore the dilution factor is 100. The volume of diluted blood used is based on the area and depth of the counting area. The area counted is 2 mm 2 and the depth is 0.1 mm; therefore the volume factor is 0.2 mm 3. Total number of cells counted dilution factor 1/volume factor = cells/mm 3 Cells/mm 3 = cells/µl or cells/µl 10 3 µl /L = cells x 10 9 /L Example: 100 x 10 3 platelets/µl 10 3 µl/l = 100 x 10 9 platelets/l 2. Average the platelet counts from the duplicate pipets and report result (x 10 9 /L or /mm 3 ). Reference Interval 150-440 x 10 9 /L Comments 1. Platelet counts should be performed within three hours after the dilution has been prepared. 2. The coefficient of variation (CV) for the 95% confidence limits is + 22%. 3. If blood is collected by a skin puncture, carefully remove the first drop of blood and collect free-flowing blood for the platelet count. This will minimize the occurrence of platelet clumping and adhesion of platelets to the puncture site. 4. If clumps of platelets are seen in the hemacytometer, the procedure should be repeated. Clumps may be due to inadequate mixing of blood or to poor technique in obtaining the blood specimen. 5. A Wright's-stained peripheral blood smear should be examined and the platelet estimate determined to confirm the hemacytometer platelet count. The platelet estimate should correlate with the platelet count + 25%. If a discrepancy exists, the platelet count and peripheral blood smear estimate should be repeated. 6. In acute leukemia, there is an increase of blast cells in the peripheral blood. Often fragments of cytoplasm about the size of platelets break off the blast cells. These cytoplasmic fragments are called hyaline bodies. They are the same size and density as platelets and may be counted as platelets by the hemacytometer or automated methods. It

is very important that all platelet counts be confirmed by slide examination so that a false increase of platelets (due to the counting of fragments) is not reported. 7. Platelet satellitism will result in falsely decreased platelet counts. With platelet satellitism, platelets adhere to neutrophils when the blood sample is anticoagulated with EDTA and is not free to be counted. Platelet satellitism can be corrected by redrawing the blood sample using sodium citrate as the anticoagulant. The resulting platelet count must be multiplied by 1.1 to account for the dilutional effect of the citrate anticoagulant. 8. A second method for manual platelet counts is the Rees Ecker method. Using the erythrocyte diluting pipet, whole blood is diluted with a solution containing brilliant cresyl blue, which stains the platelets a light bluish color. The platelets are then counted using a standard hemacytometer and bright field microscopy. 9. Technical sources of error in hemacytometer cell counts are given in Web Table 7-4. References 1. Becton-Dickinson. Unopette WBC/Platelet determination for manual methods. Rutherford, N.J.: Becton, Dickinson, and Company; 1996. 2. Brecher G, Cronkite EP. Morphology and enumeration of human blood platelets. J Appl Physiol. 1950; 3:365. Copyright ' 1995-2003 by A Pearson Company Prentice-Hall, Inc. Legal Notice