SEED Haematology. Sysmex Educational Enhancement and Development February 2013



Similar documents
BLOOD FILM STAINING EFFECTS

Preparation of Blood Films

STAINING OF PBF AND INTERPRETATION OF NORMAL AND ABNORMAL RED CELL MORPHOLOGY

LABORATORY 2 Staining and processing of blood parasites Differential counts of leukocytes (giemsa stains)

Hematology Morphology Critique

Urinalysis and Body Fluids CRg

MICROKROM MICROKROM. Basic Guidelines for Quality Staining with Romanowsky Stains

Lab 02: Blood Cytology (20 points)

GIEMSA STAIN PREANALYTICAL CONSIDERATIONS

Granulocytes vs. Agranulocytes

serology Agglutination Techniques and Blood Cell Identification

EDUCATIONAL COMMENTARY - GRANULOCYTE FORMATION AND CHRONIC MYELOCYTIC LEUKEMIA

Exercise 9: Blood. Readings: Silverthorn 5 th ed, , ; 6 th ed, ,

EDF Extended Depth of Field

A simple differential stain of blood smears using black Quink

White Blood Cells (WBCs) or Leukocytes

Laboratory 12 Blood Cells

Cardiovascular System. Blood Components

Basic Professional Training Program for Associate Medical Technologist

ABO-Rh Blood Typing With Synthetic Blood

Hematology Sequence. Blood Labs ORIENTATION OBJECTIVES. c. Microscopic Exam of a Peripheral Blood Smear (several parts)

HISTOLOGY LABORATORY. Microscope Orientation and Blood Smear Lab

RECITATION NOTES FOR EXPERIMENT # 5 A&B THIN LAYER CHROMATOGRAPHY

BioSciences. Peripheral Blood Smear Preparation. Blood Smear Preparation Materials

EDUCATIONAL COMMENTARY RED BLOOD CELLS AND WHITE BLOOD CELLS IN URINALYSIS

ArtisanLink Staining System is an automated special stains slide

Blood. Functions of Blood. Components of Blood. Transporting. Distributing body heat. A type of connective tissue. Formed elements.

Introduction to Flow Cytometry

Leukemias and Lymphomas: A primer

Pre-Lab Questions. 1. What is cell theory? 2. What do all cells contain? 3. What is a prokaryote? 4. What is a eukaryote? 5. What is an organelle?

Application Note. Single Cell PCR Preparation

NEW YORK STATE CYTOHEMATOLOGY PROFICIENCY TESTING PROGRAM Glass Slide Critique ~ November 2010

Subtypes of AML follow branches of myeloid development, making the FAB classificaoon relaovely simple to understand.

KEY CHAPTER 14: BLOOD OBJECTIVES. 1. Describe blood according to its tissue type and major functions.

LABORATORY 3: Microscopic Urinalysis

Gram Staining. The Most Commonly Used Differential Stain. Advantages:

WHICH SAMPLES SHOULD BE SUBMITTED WHEN LYMPHOID NEOPLASIA IS SUSPECTED?

Enumeration and Viability of Nucleated Cells from Bone Marrow, Cord Blood, and Mobilized Peripheral Blood

Transfection reagent for visualizing lipofection with DNA. For ordering information, MSDS, publications and application notes see

Pathology No: SHS-CASE No. Date of Procedure: Client Name Address

Protease Peptide Microarrays Ready-to-use microarrays for protease profiling

ABO-Rh Blood Typing Using Neo/BLOOD

Collect and label sample according to standard protocols. Gently invert tube 8-10 times immediately after draw. DO NOT SHAKE. Do not centrifuge.

COMPARING PLANT AND ANIMAL CELLS

MANUAL PLATELET COUNT

Platelet Transmission Electron Microscopy and Flow Cytometry 11/15/2015

CLL. Handheld record. Stockport NHS foundation trust

In order to be useful, a smear must have the following qualities:

Exercise 2. The Compound Light Microscope

Materials and Methods. Ribonuclease.--Removal of ribonucleic acid from meristematic onion cells did not show any qualitative differences

Instructions. Torpedo sirna. Material. Important Guidelines. Specifications. Quality Control

It is an important tool to assess factors that affect the bioavailability of a drug from a solid preparartion.

Blood-Based Cancer Diagnostics

GLOSSARY of STAINS Hematoxylin and Eosin (H&E) Periodic acid-schiff s (PAS) Masson s Trichrome Stain Gomori Trichrome Stain Silver Salts

WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS

BC Auto Hematology Analyzer

Comparison of Trypan Blue and Fluorescence-Based Viability Detection Methods Via Morphological Observation

Hematology Reagents and Controls Our products for your critical process

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

MALARIA PARASITE COUNTING

Cell Biology Prokaryotic and eukaryotic cells

XE-2100 Automated Hematology System. Fast, Accurate, Dependable

Uses of Flow Cytometry

LESSON ASSIGNMENT. Collection of Blood and Preparation of Blood Smears. After completing this lesson, you should be able to:

Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi-

CAP Accreditation Checklists 2015 Edition

JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR. 2nd Edition

INFLAMMATION AND REACTIVE CHANGES IN CERVICAL EPITHELIUM

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

Touch DNA and DNA Recovery. H. Miller Coyle

CHAPTER 3 OBSERVING MICROORGANISMS THROUGH A MICROSCOPE. I. UNITS OF MEASUREMENT - See Table 3.1 in text. + Fig. 3.2

The clinical relevance of measuring NRBC in the XN-CBC

Simoa HD-1 Analyzer Troubleshooting Guide. USER Sep 2014 Software Version 1.3 Beta

Real-time PCR: Understanding C t

MODIFIED TRICHROME STAIN

EXTRACTION OF DNA FROM CALF THYMUS CELLS Revised 2/1/96 Introduction

ab StayBlue/AP Plus Stain Kit Instructions for Use An immunohistochemical chromogen substrate for staining tissue sections

BLOOD-Chp. Chp.. 6 What are the functions of blood? What is the composition of blood? 3 major types of plasma proteins

Robotic Microscopy and information technology to increase accuracy, sensitivity and availability of blood cell analyses

Annexin V-FITC Apoptosis Detection Kit

Haematology what does your blood test mean?

Cytology : first alert of mesothelioma? Professor B. Weynand, UCL Yvoir, Belgium

Cells. Introduction WSBCTC 1

Annexin V-FITC Apoptosis Detection Kit

chapter 5. Quality control at the population-based cancer registry

Standardization, Calibration and Quality Control

Liquid-based cytology

ab Protein Sumoylation Assay Ultra Kit

Centre of Forensic Sciences Investigators & Submitters Technical Information Sheets

Cytology of Lymph Nodes

An overview of CLL care and treatment. Dr Dean Smith Haematology Consultant City Hospital Nottingham

Microscopy and Cellular Morphology

THERMAL TRANSFER PRINTING PROBLEM SOLVER

Annexin V-EGFP Apoptosis Detection Kit

Enteric Unknowns Miramar College Biology 205 Microbiology

Chapter 14 Urinalysis, Body Fluids and Other Specimens. Objectives:

LAB: Blood Exploration

Automated Cerebrospinal Fluid Cytology

n/a MYSTERY OF THE BLOOD STAIN (RE)

Transcription:

SEED Haematology Sysmex Educational Enhancement and Development February 2013 The role of the peripheral blood smear in the modern haematology laboratory Automated haematology cell counting The laboratory practice of haematology has evolved tremendously over the past few decades with automated analyser generated complete blood counts (CBC) having fully replaced the original manual individual parameter assay methods. The traditional review of the automated data, and more specifically the white blood cell differential count, of every sample analysed, by means of microscopic examination of the peripheral blood smear has fallen away in most laboratories. The reason for this is the enhanced precision and accuracy of automated cell counting in comparison with the traditional manual counting methods. Moreover, it is also recognised that the superiority of automated differential cell counting is limited to well characterised mature white blood cells, whereas manual microscopy is better for differentiating more immature and abnormal cells where nuances of cytological features are relied upon. In recognition of this, over and above the quantitative data, analysers provide qualitative information in the form of flags which alert the operator to the possibility of erroneous results due to interfering variables as well as the presence of abnormal cells. The manual differential count is performed by the visual examination of a stained blood smear using a light microscope. A fresh, well-made, peripheral blood smear is crucial for accurate cell morphology assessment. The components contributing towards the final result are fourfold: The quality of the smear, the quality of the stain, the quality of the microscope and the skill and experience of the microscopist. a) The making of blood smears The peripheral smear needs to be correctly made. Smears are most commonly made using the spread or wedge technique. Manual smears are made by placing a drop of blood on one side of a glass slide, and spreading this by rapidly moving a second glass slide or spreader across the first slide at an angle. A well-made peripheral smear is thick (red blood cells are overlapping) at the frosted end and becomes progressively thinner with good separation of cells toward the opposite end. The so-called zone of morphology, the area of optimal thickness for light microscopic examination, should be at least 2 cm in length. The smear should occupy the central area of the slide and be margin-free at the edges. Based on this, only selective manual peripheral blood smear review on the basis of abnormal quantitative data and flags is required. Whilst the CBC data are accepted without question, it is still commonly a knee-jerk reaction in many institutions to automatically confirm the white blood cell differential by means of microscopic examination of a peripheral blood smear. The manual peripheral blood smear Whilst the manual differential count is generally considered to be superior to an analyser generated count for pathological samples, this only holds true under very strict conditions. Producing a good quality smear requires practice. The blood smear must not be too thin or too thick and the tail of the smear must be smooth. The perfect quality smear is influenced by three factors: speed, angle and drop size. The faster the spreader slide is moved, the longer and thinner the smear will be. The slower the slide is moved, the shorter and thicker the slide will be. An angle greater than 30 makes the smear thicker; less than 30 the smear is thinner. A small drop of blood may be insufficient to prepare a slide of sufficient length; too large a drop may cause the smear to extend beyond the length of the slide.

2 The viscosity (haematocrit) of the blood, which can be highly variable from patient to patient, will also affect the smear. Blood from a patient with anaemia will have a lower viscosity and the smear will be too thin if the angle is not increased. The opposite holds true for blood from a patient with polycythaemia. Blood smears that are too thin or too thick present a problem. Extremely thin smears (caused by too small a drop, too slow spreading or too low a spreader angle), may result in red blood cells (RBC) that appear as spherocytes and in - creased white blood cells (WBC), such as monocytes and neutrophils, in the tails. An incorrect differential will result. In extremely thick smears, the counting area is too small. At least ten low-powered fields where fifty percent of the RBC do not overlap are required for an accurate WBC differential. Blood smears with excessive tails or gritty feathered ends indicate a spreader edge that is rough or dirty, or an accumulation of WBC due to either slow spreading or a very high WBC count. a) b) Fig. 1 a) Poor quality manual peripheral blood smear and b) Good quality automated smear Nucleus Cytoplasm Granules Cellular Component Chromatin Nucleoli Red Blood Cell Reticulocyte Lymphocyte Monocyte Neutrophil Eosinophil Basophil Neutrophil (toxic granulation) Eosinophil Basophil Platelet Colour Purple Light blue Dark pink Grey-blue Blue Grey-blue Pink Pink Blue Purple (dark blue) Orange-red Purple-black Purple Inclusions Malaria parasite Purple Tab. 1 Cellular component colouration in response to Romanowsky staining (Adapted from Dacie and Lewis, Practical Haematology) [1] i. How stains work The mechanism by which certain structural components of a cell stain with a certain dye whereas other similar structures do not, although staining with other dyes, depends on complex differences between dyes, how they interact with each other, as well as the ph of the stain and the cellular micro environment. Acidic structures pick up the basic dye, methylene blue, which as its name implies is blue in colour. In contrast basic or alkaline structures bind acidic dyes, in this case eosin which is pink. An easy way to remember this is to consider the intense pink colour of the eosinophil granules, and the intense purple colour of the basophil granules. The term eosinophilic refers to having a likeness or attraction to eosin (the pink dye) and basophilic to the basic or blue dye. b) The staining of the blood smear The peripheral blood smear needs to be stained so that the cytoplasmic and nuclear details of the various cell types are accentuated. Romanowsky stains or derivations thereof such as Wright, Wright-Giemsa and May-Grünwald-Giemsa are universally used in haematology. A Romanowsky stain is any stain combination consisting of eosin with methylene blue and/or any of its oxidation products. Such stains produce the typical range of blue, purple and pink colouration of cells when viewed under the microscope (Tab. 1). Methyl alcohol is used as both a solvent and fixative and forms part of the Romanowsky staining procedure. ii. Factors giving rise to faulty staining Many factors can give rise to a poorly stained slide. This may manifest as a slide that is either too dark or too pale, too blue or too pink, granules may appear too dark or are absent, the background may appear blue or there may be stain deposits. Different cellular structures have different affinities for the various dyes DNA binds rapidly, RNA lags behind and haemoglobin is slowest. Correct timing is therefore critical for a good quality outcome. Having the various dye components in the correct ratio is also critical as they

3 interact with each other. This aspect of variation is eliminated with the commercially available dye formulations but is a common source of error in home-made stains. As already alluded to, ph of the stain solution is critical. It is generally recommended to be between 6.8 and 7.2. Another common source of error is the overuse of stains, high ambient temperatures resulting in evaporation and contamination from bacteria and other debris. This is a small, portable, solidly constructed, standardised wedge smear maker. It is easy to use and clean and has replaceable spreader blades. A small drop of blood is placed on the one end of the slide, and the spreader pulled across. The result is a well-made smear of consistent quality with an even spread of cells. b) The RAL Stainer Automated slide making and staining Unless the laboratory staff follows strict guidelines in slide making and staining, the probability that poor quality smears will be generated exists. This in turn may give rise to erroneous microscopic interpretation with potential serious consequences for patient care. In line with the principles of good laboratory practice, standardised slide making and staining procedures will guarantee good quality peripheral blood smears. The best form of standardisation is automation. In most laboratories that do have some form of automation, this is limited to the staining component. Most automated staining systems are so-called open systems which allow the use of any stain, including home-made ones, hence only the timing of the staining procedure is controlled. The potential for poor staining due to stain overuse and incorrect composition is not eliminated. Furthermore, the fact that the input into the automated stainer will invariably still be manually made smears, a quality outcome is still not guaranteed. The other end of the spectrum is a fully automated slidemaker stainer, such as the Sysmex SP-1000i, which is only cost-effective for high throughput laboratories. The good news is that Sysmex, in partnership with RAL Diagnostics, now has a solution to offer the smaller laboratory. a) The Sysmex HemoSlider Fig. 3 The RAL Stainer The RAL Stainer is an easy to use automated staining unit. The reagents are provided in closed cartridges which have RFID tags which prevent reagent usage beyond expiry as well as over usage, a common problem with other non-closed methods. The staining protocols have been optimised for peripheral blood smears made using the HemoSlider. All sources of error mentioned above can be completely eliminated using the HemoSlider RAL combination. The analyser allows for continuous loading and unloading with the ability to insert an urgent slide at any time. A major advantage is that no maintenance is required and from a safety and environmental perspective, the stains are methanol free. Fig. 2 The Sysmex HemoSlider The stainer has a protocol for bone marrow slide staining as well as for malaria screening. A semi-automated version of this stainer will be available soon. Here an operator will need to move the slide basket from one stain tank to the next, upon the alert from the timer within the analyser. This timer is automatically set in line with the staining protocol selection.

4 The microscopic review of the peripheral blood smear Besides a good quality smear and stain, optimal results can only be obtained with a well maintained microscope and a skilled microscopist. As with all items of laboratory equipment, the microscope requires regular routine maintenance. Hot humid climates are particularly challenging as fungal growth will occur if no precautions are taken. This will damage the optics and render the microscope useless. In contrast, in hot dry climates, the problem is dust. The microscope needs to be set up correctly to obtain the correct amount of illumination and to eliminate any refractive artefacts which may be mistakenly interpreted as cellular inclusions. Manual versus automated differential cell counts For a detailed description of the technical detail of how Sysmex analysers count and differentiate white blood cell sub-populations, please refer to the SEED edition: Over view of the benefits of switching from a 3-part differential to a 5-part differential haematology analyser. In instances where an automated differential count was obtained, and is subsequently compared with a manual differential count, differences are observed. The reaction to this for most laboratory personnel is to question the accuracy of the automated count. We need to remind ourselves that the assignment of reference method status to the manual differential count is based on the CLSI guideline of an 800 cell count (2 operators counting 200 cells each on two different smears), and not the routinely practiced single operator single smear 100 cell count. Furthermore, automated analysers count many more events. For example, a Sysmex analyser will generate a white blood cell differential count from about 10 000 cells as compared with just 100 in the standard manual method. Differences can be quite substantial for various reasons. a) The unequal distribution of cells in a smear Unfortunately, even in a perfectly made smear, the distribution of cells is not random. As a rule, neutrophils and monocytes tend to accumulate at the edges of the smear, and lymphocytes in the middle. This problem is accentuated if the smear is too thin or the edge of the spreader is rough. In automated cell counting, cells are in suspension and every single cell in the sample aliquot is counted. b) Abnormal cell targeting and cell skipping It is a fact of human nature, that as we scan the slide for a good area to count, we will hone in on any unusual cells that we see and use that area as our starting point. In this regard, the percentage of abnormal cells may be overestimated. Likewise, the tendency to simply skip any cells that are morphologically difficult to categorise is common practice. The analyser in turn identifies and categorises every cell. In general, the monocyte count is the one that is most frequently identified as giving discrepant results dependent on counting method. The reasons for this are several fold. Firstly, monocytes tend to accumulate in the tail of the smear which as a rule is not a counting area. Secondly, monocytes can be difficult to distinguish morphologically from activated lymphocytes, and hence are commonly skipped in the 100 cell count. Thirdly, the older the blood is before the smear is made, the greater the disintegration of cells in general and the more difficult the accurate identification of monocytes, in particular, becomes. Eosinophils and basophils, although relatively uncommon, are very distinctive and therefore remain easy to identify. Fourthly, monocytes are a minority cell population so any small differences, introduced by points one to three above, are accentuated. Consequently, automated monocytes as a rule are higher than manual monocyte counts. These differences would be lessened if laboratories were to stick to the CLSI recommendation of the 800 cell count but this is of course not practical, even in the most fastidious of laboratories. In recognition of the unreliable nature of manual monocyte counting, flow cytometric enumeration using CD45 and CD14 fluorescence-labelled monoclonal antibodies has been proposed as the new reference method for monocyte counting. This has been shown to correlate well with automated counting. 2

5 Reference ranges for automated and manual differential cell counts The way to overcome the apparent differences between automated and manual differential cell counts in general, and monocyte counts in particular, is to adhere to general principles of good laboratory practice and establish reference ranges specific to each method. In this way the values obtained will be interpreted in relation to the appropriate reference and the clinical judgment will not be impacted. Normal versus pathological cell populations As described in SEED Overview of the benefits of switching from a 3-part differential to a 5-part differential haematology analyser, automated analysers alert the operator to the suspected presence of abnormal white blood cells by means of flags. In this instance, a peripheral blood smear should be made and reviewed microscopically. 3. Differences in manual and automated differential counts, especially for monocytes, will occur. The use of a separate method for specific reference ranges is recommended. References [1] Dacie and Lewis, Practical Haematology, 9th edition, Edited by SM Lewis, BJ Bain, I Bates, Chapter 4: Preparation and staining methods for blood and bone marrow smears, page 50. [2] Hübl W, Andert S, Erath A, Lapin A, Bayer PM. (1995): Peripheral blood monocyte counting: towards a new reference method. Eur J Clin Chem Clin Biochem 33: 839-845. Compiled by Dr Marion Münster For completely normal samples though, where no flags are generated, the automated differential count will be more accurate making the manual count obsolete. Take home message 1. In the era of modern automated technology, there is no need for a manual differential count and peripheral blood smear review of all cases. This should be reserved for those samples identified by the analyser as being suspicious for underlying morphological or cell count abnormalities. This would enable laboratories to utilise the skills and time availability of their staff wisely by focussing on only those smears that truly require their attention. 2. In order to ensure that the microscopic review will provide a report that can be trusted for clinical judgement, the quality of the smear and stain must be optimal. The best way to achieve this is by means of automation of both slide-making and staining. Sysmex has a solution for this means of the Sysmex HemoSlider and RAL Stainer. Sysmex Europe GmbH Bornbarch 1, 22848 Norderstedt, Germany, Phone +49 40 52726-0 Fax +49 40 52726-100 info@sysmex-europe.com www.sysmex-europe.com