Agilent N5970A Interactive Functional Test Software: Installation and Getting Started



Similar documents
Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

Agilent FieldFox Remote Viewer

Agilent U2000 Series USB Power Sensors

Installing the Gerber P2C Plotter USB Driver

Release Notes: PowerChute plus for Windows 95 and Windows 98

F-Secure Online Backup Quick Installation Guide

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

WD Sentinel DX4000. Small Office Storage Server. Administrator s Quick Install Guide

Agilent E5063A ENA Series Network Analyzer

WD Sentinel DX4000. Small Office Storage Server Administrator s Quick Install Guide

Guide to Installing BBL Crystal MIND on Windows 7

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

The Next Generation in Automated Oscilloscope Test

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

PCI Express 1.0 (2.5 GT/s) Protocol Test

Updating the QIAcube operating software

SOFTWARE INSTALLATION INSTRUCTIONS

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

Printing Options. Netgear FR114P Print Server Installation for Windows XP

Computer Specifications

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

AT-S39 Version 1.3 Management Software for the AT-8024 and AT-8024GB Fast Ethernet Switches. Software Release Notes

PXI and AXIe Modular Instrumentation

COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS

Contents. Hardware Configuration Uninstalling Shortcuts Black...29

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Welch Allyn PCH100 and PCH200 Installation Guide

Application Note. Double click System tray icon after service started. Click start/continue button

EntraPass WebStation. Installation Manual DN

WA2102 Web Application Programming with Java EE 6 - WebSphere RAD 8.5. Classroom Setup Guide. Web Age Solutions Inc. Web Age Solutions Inc.

e-dpp May 2013 Quick Installation Guide Microsoft Windows 2003 Server, XP, Vista, 7 Access Database

Agilent IMS-SIP Network Emulator Software (E6966A)

Motorola Phone Tools. Quick Start

Registered Trademarks and Proprietary Names

Topaz Installation Sheet

Agilent 4338B Milliohm Meter

Agilent U2000 Series USB Power Sensors

3M Occupational Health and Environmental Safety 3M E-A-Rfit Validation System. Version 4.2 Software Installation Guide (Upgrade) 1 P age

DX8100 Series Symantec AntiVirus Corporate Edition Installation Instructions. Version

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens

User Installation Guide

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

Installation Guide. Your FedEx Ship Manager system number. Before you start

PCLinq2 Hi-Speed USB Bridge-Network Cable. Quick Network Setup Guide

PXI and AXIe Modular Instrumentation

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

Norton Ghost How to copy partitions from an HDD to a Samsung SSD

CANON FAX L360 SOFTWARE MANUAL


Setting Up Novell Small Business Suite

QuarkCopyDesk 9.1 ReadMe

Integrating CaliberRM with Software Configuration Management Tools

FedEx Ship Manager Software. Installation Guide

Upgrading from Call Center Reporting to Reporting for Contact Center. BCM Contact Center

BillQuick HR 2008 Start-Up Guide

Analyzer 2.0. Installation Guide. Contents

Targus USB Port Adapter USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

WD Hard Drive Interface Guide

MN POS TM. Hardware & Peripherals. All required hardware may be purchased from Home Office.

Agilent Television Power Consumption Testing. Application Note

Release Notes - Installing the Wireless Receiver on a PC.

LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)

Print Server Application Guide. This guide applies to the following models.

CODESOFT Installation Scenarios

Installation Qualification/Operational Qualification Protocols and Instructions. Experion Automated Electrophoresis Station and Software

U90Ladder / VisiLogic /UniLogic and software utilities system requirements. Contents

Before you start, you should prepare the following items

STATISTICA VERSION 11 CONCURRENT NETWORK LICENSE WITH BORROWING INSTALLATION INSTRUCTIONS

Registered Trademarks and Proprietary Names

AXIS Camera Station Quick Installation Guide

Software Installation Requirements

File Management Utility. T u t o r i a l

Quantum View SM Manage Administration Guide

WA1791 Designing and Developing Secure Web Services. Classroom Setup Guide. Web Age Solutions Inc. Web Age Solutions Inc. 1

Remote Deposit Capture Installation Guide

Installation Instruction STATISTICA Enterprise Server

Configuring DHCP for ShoreTel IP Phones

NTL Studio SQL Database Installation & Configuration

Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide


Preparing the Windows version of the software for use

USB Driver Installation for Windows XP

Installation Guide for Workstations

Sales Builder For Windows (SBW) TM

Installing the Webstation

Quantum View Manage Administration Guide

Installing a Westell USB Network Adapter

Nexio Connectus with Nexio G-Scribe

Install Guide Housatonic Project Plan for Web. Housatonic Software - Project Plan 365 App

USB DRIVER INSTALLATION GUIDE

Omni 56K USB Lite Quick Start Guide

GETTING STARTED. Please turn to the correct section for your operating system

Agilent 4339B/4349B High Resistance Meters

InventoryControl for use with QuoteWerks Quick Start Guide

LockView CompX Database & Network Configuration & Installation Manual

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Installing Windows Rights Management Services with Service Pack 2 Step-by- Step Guide

Transcription:

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started Application Note The N5970A Interactive Functional Test Software along with the 8960 Series 10 (E5515C) wireless communications test set provides a complete solution for performing real-world functional tests on cellular mobile devices. The N5970A software facilitates real-world testing because it is designed to allow simultaneous testing of the various activities that are available in a device. This solution includes a simplified means of setting up the various server applications (FTP, HTTP, SMS, etc.) that enable you to perform and test these activities. To get started using the N5970A software and to ensure that it works properly, there are certain system requirements that must be met and some setting that must be configured. This guide lists these requirements as well as provides step-by-step instructions on installing and configuring Agilent s N5970A software so you can get started using it as quickly as possible.

Table of Contents Interactive functional test system requirements.3 How to install the N597X server software (on the server PC) 4 How to install the N5970A Interactive Functional Test software (on the application workstation)...6 How to get started with the N5970A Interactive Functional Test software 6 2

Interactive Functional Test System Requirements Server PC system requirements An IBM (or compatible) PC with at least: 1.8 GHz Pentium dual-core processor or later Microsoft Windows XP Professional (SP2) or higher 2 GB RAM minimum 1 GB of available hard disk space 10x CD-ROM drive LAN port Application workstation system requirements An IBM (or compatible) PC with at least: 1.8 GHz Pentium dual-core processor or later Microsoft Windows XP Professional (SP2) or higher 2 GB RAM minimum 1 GB of available hard disk space 10x CD-ROM drive LAN port (a second LAN port is required for remote operation of the Interactive Functional Test software). Note: USB to LAN adapters are not currently supported by the Interactive Functional Test software Microsoft Internet Explorer version 6.0 or later An installed, configured, and tested Agilent Technologies or National Instruments IEEE 488.2 GPIB interface The latest version of VISA (Virtual Instrument Software Architecture) from the manufacturer of your GPIB card A USB 1.1 or later port (The hardware security key that is shipped with the software is connected to this port) Other hardware and software requirements A Linksys BEFSR81 8-port cable/dsl router LAN cables (number varies depending on which LAN topolgy you choose) N5970A Interactive Functional Test Software installation CD-ROM N5970X Interactive Functional Test Software server install CD-ROM An Agilent 8960 Series 10 wireless communications test set with one of the following lab applications: E6701F revision F.00.27 E6701U revision U.00.22 E6703E revision E.00.23 E6703U revision U.00.20 E6785E revision E.00.25 E6785U revision U.00.23 3

Installing the N597X Server Software (on the server PC) NowSMS Apache Filezilla This section assumes that you have acquired all the items listed in the Interactive Functional Test System Requirements section. 1. Close any applications currently running. 2. Insert the N597X Interactive Functional Test Software Server Install CD-ROM into the CD-ROM drive. Note: The server software must be installed on the C: drive. It should automatically run the installation program. If it does not start automatically, navigate to the CD-ROM and double-click N597X_Server_setup.exe. Follow the step-by-step instructions during the software installation. The NowSMS server will now be installed. It must be installed in the default installation directory. Do NOT change the installation directory during the install. Once the next screen is selected, these instructions will no longer be available so it would be advisable to copy or print them for future reference. The NowSMS server requires an activation code which you will need to load. When the wizard starts the NowSMS installation, respond in the method below to the questions so you can install the activation code. It is important that you respond to these questions in a timely manner. If you are delayed in responding to these questions, you will be prompted to start the Apache Server installation. Please complete the NowSMS installation before continuing with the Apache Server installation. You may have to move the Apache Server installation window to access the NowSMS windows. 1. If prompted that "xx days remain in your NowSMS2006 trial period", push OK. 2. If prompted to "Select Installation Option", press "Install with a purchased serial number", or if prompted "Do you have a new activation code to install, or wish to request an activation code?", push OK. 3. Click Yes, when asked "Do you already have this activation code?" 4. Select "Load from File" when asked to "Enter NowSMS Activation Code". 5. When the open dialog box appears, navigate to the install CD and select the file called "NowSMS-Serial-Number-89600050.txt". 6. Click Open. The Apache Server will now be installed and configured. If your security software prompts you that it has blocked the Apache HTTP Server, please Unblock the Apache HTTP Server. The Filezilla server will now be installed. When the Connect to Server information appears, check the "Always connect to this server" check box and then select OK. 4

Starting the N597X Application Servers The applications servers installed on this CD are started automatically once they have been installed. Ensure that the following: Apache is running as a service FileZilla is running as a service UDPServer is running NowSMS is running as a service 5

Installing the N5970A Interactive Functional Test Software (on the application workstation) This section assumes that you have acquired all the items listed in the Interactive Functional Test System Requirements section and have finished Installing the N597X Server Software (on the server PC). 1. Install the GPIB interface and set up the GPIB VISA drivers. 2. Close any Microsoft Windows applications that are running. 3. Insert the N5970A Interactive Functional Test Software CD-ROM into the CD-ROM drive. The installation should start automatically. If it does not start automatically, navigate to the CD-ROM and double-click N5970A_setup.exe. Follow the step-by-step instructions during the software installation. Note: The E6584A Wireless Protocol Advisor (WPA) is not included on the N5970A Interactive Functional Test Software CD-ROM. At the end of the Interactive Functional Test Software installation, you will need to download WPA revision A.07.00 or above, which can be accessed via the WPA product page located at www.agilent.com/find/e6584a under Technical Support >> Drivers and Software. Getting Started with the N5970A Interactive Functional Test Software This section assumes that you have acquired all the items listed in the Interactive Functional Test System Requirements section, have finished Installing the N597X Server Software (on the server PC), and have finished Installing the N5970A Interactive Functional Test Software (on the application workstation). 1. Connect a GPIB cable between the workstation GPIB interface and the 8960 test set. A power supply is required to analyze the battery profile of the DUT and can be added at any time. The power supplies that are currently supported are Agilent's 66311B, 66311D, 66321B, 66321D, 66319B, 66319D, 66309B, and 66309D. 6

Getting Started with the N5970A Interactive Functional Test Software (continued) 2. If you want your workstation to access the internet, configure your LAN interface device and your LAN settings to provide access to your company intranet and internet. Verify that the workstation can access the internet. (For more information, refer to the Proxy Server Settings topic in the N5970A Help File, which can be accessed within the N5970A application or at www.agilent.com/find/n5970a.) Note, at this point it is assumed that the router is not being used, and that, if an internet connection through the workstation is desired, the workstation is connected directly to your company internet. 3. Ensure that a hardware security key is inserted into a USB port on the workstation. 4. Start the N5970A Interactive Functional Test Software. (Ignore any error messages that are displayed the first time you start the Interactive Functional Test Software.) 5. Select the Configuration tab. 6. In the list of Available configurations, select Instrument Control. 7. In the Instrument Control screen, select the proper GPIB interface and GPIB address for Test set 1 (and the power supply, if applicable). Click the *IDN? button to test if you have set up the GPIB settings correctly. The *IDN? results are displayed in the *IDN? results field. Note, if you do not want the Interactive Functional Test Software to check the test set for the correct lab application and prefer to use the lab application that is currently installed, check the Use Current LA box. 8. Right-click the test set connection Status Monitor located at the bottom left corner of the screen. The first time the Interactive Functional Test Software is started, this field will display an error message with a red background. In the right-click menu select "Enable Status Monitor". 7

Getting Started with the N5970A Interactive Functional Test Software (continued) 9. Wait for the test set connection Status Monitor to update and Test Set Application status to update. Once they have, right-click again on the test set connection Status Monitor and select "Disable Status Monitor". Verify that the instrument error message goes away. 10. In the Available configurations list, select LAN Topologies. Use the Selected LAN topology trade-offs information to determine the topology that best meets your needs. 11. Once you have chosen a topology (click on the link), press the Pre-Wizard Tasks button. Ensure that the title bar in the pre-wizard tasks matches the LAN topology you have selected. 12. The Pre-Wizards tasks must be completed before you run the wizard. It is recommended that you print them so that you can mark the tasks that you have completed. 13. Once you have completed all the Pre-Wizard tasks, press the LAN Topology Setup Wizard button. Note: There are several steps in the LAN Topology Setup Wizard (the number of steps varies depending on which topology you choose) and therefore can take over an hour to complete. You must complete the wizard before any of the settings are saved. 14. The wizard will guide you through the process of setting up the LAN Topology. IMPORTANT: Read and follow the directions on each step of the wizard carefully. Most setup issues are due to incorrect settings/connections done in the wizard. 15. When the wizard has been successfully completed, you will be taken to the Connections Integrity screen within the Configuration tab. 8

Getting Started with the N5970A Interactive Functional Test Software (continued) 16. On the Connections Integrity page, press each Check button to test the configuration to ensure that the wizard has configured all the settings correctly. 17. If all the Connections Integrity fields show OK, then you are ready to add a Device Under Test (DUT) to the Interactive Functional Test Software. 18. Once the DUT is properly configured and connected as in the figure above, you can perform any of the various interactive testing activities that are available under in the Interactive Testing tab. 19. For more information, visit www.agilent.com/find/n5970a. 9

www.agilent.com For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada Latin America United States Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Thailand Europe & Middle East Austria Belgium Denmark Finland France Germany Ireland Israel Italy Netherlands Spain Sweden Switzerland United Kingdom (877) 894-4414 305 269 7500 (800) 829-4444 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 1 800 226 008 0820 87 44 11 32 (0) 2 404 93 40 45 70 13 15 15 358 (0) 10 855 2100 0825 010 700* *0.125 /minute 01805 24 6333** **0.14 /minute 1890 924 204 972-3-9288-504/544 39 02 92 60 8484 31 (0) 20 547 2111 34 (91) 631 3300 0200-88 22 55 0800 80 53 53 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: March 27, 2008 Pentium is a U.S. registered trademark of Intel Corporation. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation. Product specification and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2008 Printed in USA, May 20, 2008 5989-8712EN 10