Enrollment and Billing Test Plan Scenarios Dual and Rate-Ready Billing



Similar documents
EDI TRANSACTION REFERENCE DOCUMENT

Data Exchange and Protocol Process Flows for Electric Deregulation in The State of New Jersey

Welcome to PSE&G s Third Party Supplier Electric Workshop

CONSOLIDATED BILLING BUSINESS PROCESSES (UTILITY RATE READY)

Implementation Guideline

Understanding Your Bill

Welcome to PSE&G s Third Party Supplier Gas Workshop

Supplier Services FAQ New Jersey

Supplier Services FAQ - Ohio

ELECTRONIC DATA INTERCHANGE AGREEMENT

BALTIMORE GAS AND ELECTRIC COMPANY ELECTRONIC DATA INTERCHANGE TRADING PARTNER AGREEMENT

PG Energy. Communications Protocol. For Natural Gas Suppliers Serving Customers under Rate Schedules RTS and GTS

EFT Processing. (Automatic Electronic Payment Processing) Section Contents

User Guide to Adding a NeuQs Help Desk Call

RHODE ISLAND. Electronic Business Transactions (EBT) Standards. for Electronic Data Interchange (EDI) in a Restructured Electric Industry

OUR ELECTRICITY AGREEMENT Constellation Energy Power Choice, Inc. P.O. Box 4911, Houston, TX 77210

MAINE FREQUENTLY ASKED QUESTIONS (FAQ) SUPPLIER TECHNICAL WORKSHOP

Energy Price Fact Sheet

BGE/BG/FVTT/1010. Business Natural Gas Tariff guide October 2011

Third Party Supplier Support Operating Manual

997 Functional Acknowledgment

Table of Contents. Visma Software International Contents

Natural Gas as a Transportation Fuel

Most household services provide you with a fixed monthly bill: Broadband Internet service

If you have difficulty logging in to ESS, here are some other helpful hints to remember:

Order Lifecycle Visibility. Alcatel-Lucent Supplier Registration

Your gas and electricity bill actual readings

PART 6 FORM OF STANDARD CUSTOMER ELECTRICITY SALES AGREEMENT A. STANDARD RESIDENTIAL CUSTOMER ELECTRICITY SALES AGREEMENT

R12 Entering Invoices in Payables. (Oracle EBS Payables)

Financial ACH and Positive Payment -

Section 1 Bills Bills Bills All copies of bills and information obtained from company websites

Ariba einvoicing Supplile i r r P O F lilp i T ra r in i in i g

Energy Toolkit Surgery. Utility Bills. Sustainability Team. March Philip Pike Energy Manager

Business Process Design Team Level 2 Process Diagram

Best Practices for Submitting Tesco Invoices via Tungsten

Help-Operational Guidelines for Online RE-11 & RE-12. Step 1 : Open URL from website Go to Click on Link1 or Link2

Technical Operating Profile

Convergence of Wholesale And Retail Markets: The Texas Experience

How to monitor your energy use

CALCULATION INSTRUCTIONS

Energy Price Fact Sheet

Transmission Related Station Power Use at Substations

Energy Tariffs and Associated Charges

ENERGY MANAGEMENT SOFTWARE. For Windows XP, Vista, Windows 7 ( 32 & 64 bit ) Mac OSX 10.5+

El Paso Electric Company

Energy Shopper s Guide

Third Party Supplier Electric Operating Manual. Aug 27, 2014 (last updated)

Prudential plc. Basis of Reporting: GHG emissions data and other environmental metrics.

PowerLogic Tenant Metering Billing and Meter Reading Software Solutions


[1] Viewing invoice details:

UNDERSTANDING YOUR UTILITY BILL A GUIDE FOR BUSINESSES IN OHIO

CONSTELLATION ENERGY TERMS AND CONDITIONS

IMPLEMENTATION GUIDELINES FOR ANSI ASC X12 EDI CONVENTIONS FILE TRANSFER (996) TRANSACTION SET

Terms and Conditions for your Natural Gas and/or Electricity Price Plan.

PROACTIS: Supplier User Guide Contract Management

To-Be Process Review Workshop

User Manual Nexion Payment Solutions Nexion Call Centre Version 3.5. Processing Manual Credit Card Transactions/ Card not present

MODULE 2: FIXED ASSET TRANSACTIONS. Module Overview. Objectives

DUQUESNE LIGHT COMPANY ELECTRIC GENERATION SUPPLIER COORDINATION TARIFF. Issued By. DUQUESNE LIGHT COMPANY 411 Seventh Avenue Pittsburgh, PA 15219

Redlined BSCP71 text for CP1430 Clarification to the ECVA/MVRN processes

The CCA Handbook. Chapter 5 Setting Up Electronic Communications & Compliance Testing. Version 2.0 May 1, 2015

Electronic Data Interchange (EDI) Trading Partner Agreement

THE ENMAX ENERGY BILL

The RES Handbook. A Guide to Conducting Business with Ameren in the Competitive Electric Marketplace in Illinois

EDI Insight Manual. Training Manual. Presented By

UNDERSTANDING YOUR UTILITY BILL A GUIDE FOR BUSINESSES IN INDIANA

Generator Warranty On-Line System Documentation

Portland General Electric Implementation Standard

WMATA Supplier Portal. Account Management

How To Get A Gas Supply License In New Jersey

PEC CURRENT RATES AND FEES. Brenda Snider Rates and Special Projects Manager

Energy Price Fact Sheet

INTERCALL ONLINE Administrator Invoices User Guide

Frequently Asked Questions Re: Bank Change for taxpayers that make ACH credit payments

Questions and Answers from EPA s Webinar on Green Power Purchasing Aggregations Table of Contents:

Paper #1: Best Practices for Suppliers

Business Compromise Scam

Transcription:

Enrollment and Billing Test Plan Scenarios Dual and Rate-Ready Billing Internet Connectivity Scenario C.501: Internet: Connectivity Test Test the ability to send a file via the Internet standard protocol. Arbitrary File F1 Utility Any Utility sends any type of X12 file X12 file sent to to the to test connectivity. File should have correct header information for the F2 997 responds with a 997 FA 997 sent to complete connectivity test C.501 Enrollment Level 2 Scenarios E.001: Failed Enrollment Test an enrollment where the account number on the 814e can not be found in Utility s customer database as a valid account number. This enrollment request must be rejected. 999999999999 E.001 F1 814e Enrollment: Create and send enrollment request with an account number that does not exist in Utility s customer database 814e created and sent will send back a response rejecting the enrollment due to an invalid account number REF02 = A76 (Reject Reason Code), REF03 = Account Not Found 1

E.002: Historical Usage + Change by Test an enrollment with a request for the Utility to send to the supplier, historical usage information. The Utility replies with an enrollment response, 814er, accepting the enrollment, along with historical usage information, 867hu. The will send a Change Request, the Utility will send the Change Response. E.002 F1 814e Enrollment: Create and send enrollment request with account having single meter 814e created and sent F1 814e or 814h Hist Usage Request: On enrollment, 814e, request historical usage OR send separate 814H request for historical usage.0 will send back response accepting the F2 Utility 814er or 814hr Hist Usage Response: Utility will historical usage request. F2 Utility 867hu Hist Usage: Utility send 12 month historical usage information F3 814c Change from : will request a (any ) F4 Utility 814cr Change Response from Utility: Utility will reject or accept the E.003: Change by Utility E.003 Historical Usage requested 814er created and On the 814er, verify ok to receive historical usage information 867hu created and Any valid REF*TD Change accepted or rejected Test any valid Utility, and the will reply with a Change Response. will F3 Utility 814c Change from Utility: Utility will Any valid REF*TD F4 send a 814cr Change Response from : will accept a Change accepted 2

E.004: Drop by Test a request to drop the customer, 814d, from the, then the Utility replies with a drop response, 814dr, accepting the drop. E.004 will F3 814d Drop from : requests to drop the customer F4 Utility 814dr Drop from Response: Utility sends response accepting drop REF02 = B38 (Dropped by customer request) Ex: ASI = ASI*WQ*024 Dual Billing Level 2 Scenarios B.101: Dual Billing: Usage, Cancel/Restate Test Dual Billing usage plus cancel and restating usage. The sends an enrollment request, 814e, for a customer. The Utility replies with an enrollment response,814er accepting the enrollment. Include cancelled and restated usage. F1 814e Enrollment: Create and send 814e created and enrollment request with account sent having multiple meters. Request dual billing. F2 Utility 814er Enrollment Response 814er created and F3 Utility 867mu Usage/Monthly: Utility will send F5 Utility 867mu Usage/Monthly: Utility will cancel F5 Utility 867mu Usage/Monthly: Utility will restate B.101 F5 Utility 867mu Usage/Monthly: Utility will send second month usage w/ bad account number F6 824?? bad account number 824 created and sent 3

Rate Ready Billing Level 2 Scenarios B.201: Rate Ready: Remittance, Prev/Curr Balance, Taxes Test multiple meters, Usage, Invoices, and Remittance Test having previous and current balance, taxes, usage. Does NOT include ACH payment test. B.201 will F3 Utility 867mu Usage/Monthly: Utility will send 810 created and sent F4 Utility 568 Customer makes payment. Utility 568 created and sent sends 568 Collections F4 Utility 820 Remittance: Utility will send first 820 created and sent month remittance detail. ACH payment will NOT be tested; only remittance detail B.202: Rate Ready: Demand and Consumption Test both demand and consumption (Electric - KW & KWH, Gas - HH Only). enrollment request with a meter that measures both demand and consumption. B.202 will F3 Utility 867mu Usage/Monthly: Utility will send 810 created and sent 4

B.204: Rate Ready: Cancel/Restate Test where usage and invoice had to be cancelled and restated. enrollment request with single meter B.204 will send back response accepting the F3 Utility 867mu Usage/Monthly: Utility will send F5 Utility 867mu Usage/monthly: Utility will cancel F5 Utility 810 Invoice: Utility will cancel first F5 Utility 867mu Usage/monthly: Utility will restate F5 Utility 810 Invoice: Utility will restate first GAS 850DDR Test Scenario G.100: 850 DDR - Not Applicable to Electric Test the 850 DDR transaction. F5 Utility 850DDR Utility creates and sends 850DDR created and 850DDR transaction G.100 5