Extraction to Injection in a Single Process

Similar documents
MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

How To Test For Contamination In Large Volume Water

Purification of reaction mixtures using flash chromatography.

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

High-Throughput 3-D Chromatography Through Ion Exchange SPE

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Oasis HLB Cartridges and 96-Well Plates

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Sample Preparation Using Solid Phase Extraction

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Innovative vs Traditional

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Gas Chromatography Liner Selection Guide

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

GC-xt. The most flexible GC /GC-MS liquid sample injector

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Syringes 5. Contents. Autosampler 6. MEPS 18 Product Data 18 Part Numbers 19. Manual 20. Guided Plunger 24 Product Data 24 Part Numbers 25

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Sensitive and Rapid Determination of Polycyclic Aromatic Hydrocarbons in Tap Water

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow

A Novel Approach to Low Volume Sample Preparation

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

Solid Phase Extraction for Water Analysis. presented by

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Sorbents. [ A] [ A] aq. Strong affinity = large K D. Digital chromatography: all-or. or-nothing LC mechanism to extremes K =

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

SGE Syringe Selection Guide

A Complete Solution for Method Linearity in HPLC and UHPLC

ABRF 2004 Poster# P55-S Displacement Chromatography Effects Can Cause Highly Selective Sampling of Peptides During Solid Phase Extraction Cleanup

Empore. 96-Well Solid Phase Extraction Plates. Technical Information. Instructions for Use. Product Characteristics. Product Description

SPE Reference Manual & Users Guide. Reference Manual & Users Guide

Quantitation of Drugs in Dried Bloodstains. Thomas Meyer Anna Gomenyuk Nadiah Lester

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Enhancing Utility and Throughput of SPME using Advanced Automation Strategies

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

S olid Ph ase Extraction (SP E) Method:

Determination of Caffeine in Beverages HPLC-1

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0)

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

Opiates in Urine by SAMHSA GC/MS

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Comparison of the Reversed-Phase Selectivity of Solid Core HPLC Columns

Automation of Sample Preparation in Ion Chromatography

ORGANIC SAMPLE PREPARATION

Sample Preparation for Forensic Toxicology and Clinical Research. Part 1: Sample Preparation Options

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE

PrepTip. Reverse Phase PrepTip User Guide

Optimization of SPE for Analysis of Mandelic Acid as a Biomarker of Exposure to Ethyl Benzene

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Pipette Tips PACKARD BIOSCIENCE MultiPROBE II COMPATIBLE

Overview. Purpose. Methods. Results

A New QuEChERS Dispersive SPE Material and Method for Analysis of Veterinary Drug Residue by LC-MS-MS

Key Words. Introduction

METHOD 8310 POLYNUCLEAR AROMATIC HYDROCARBONS

RapidFire High-throughput MS technology. Enhancing Drug Discovery Turning Mass Specs into Plate Readers

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

Amino Acid Analyzer L-8900

PCBs DETERMINATION IN TRANSFORMER OIL BY SPE AND GAS CHROMATOGRAPHY ANALYSIS

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Expectations for GC-MS Lab

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Basics of SPE Technology & Mechanisms. Pieter Grobler, Sigma-Aldrich RSA

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

LC Application Note.

Affi-Prep Protein A Matrix Instruction Manual

Application Note. Online SPE-LC analysis of aflatoxins advances in sample preparation. Summary. Introduction. Fig. 1. Category Food Matrix

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

An Automated Method for the Selective Solid Phase Extraction of Zearalenone from Wheat Using Molecularly Imprinted Polymers

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Online SPE-LC-APCI-MS/MS for the Determination of Steroidal Hormones in Drinking Water

AppNote 9/2013. Automated Derivatization, SPE Cleanup and LC/MS/MS Determination of Glyphosate and Other Polar Pesticides KEYWORDS ABSTRACT

Determination of Tricyclazole in Water Using Solid Phase Extraction and Liquid Chromatography

Transcription:

Extraction to Injection in a Single Process MEPS Fast Miniaturized SPE Save hours in sample preparation Semi or fully automate to improve workflow and increase productivity Reduce solvent usage and sample volume Australia & Pacific Region Europe Japan USA

MEPS Made Simple MEPS Explained MEPS is Micro Extraction by Packed Sorbent and is a development for sample preparation and handling. MEPS is the miniaturization of conventional SPE packed bed devices from milliliter bed volumes to microliter volumes. The MEPS approach to sample preparation is suitable for reversed phases, normal phases, mixed mode or ion exchange chemistries. MEPS is available in a variety of common SPE phases. The MEPS Barrel Insert and Needle Assembly (BIN), contains the stationary phase, and is built into the syringe needle (Figure 1). Figure 1 Schematic of the MEPS BIN in the syringe needle. The Advantage of MEPS Historically, many sample preparation methods used liquid-liquid extraction (LLE) which required large volumes of sample, solvents and time. Advantages of SPE over LLE include: less time; can be developed into a fully automated technique; requires less solvent, and offers selectivity. MEPS miniaturizes SPE removing interfering matrix components and selectively isolating and concentrating analytes. MEPS increases the advantages of conventional SPE in the following ways: Significantly reduces the time needed to prepare and inject samples. combined with LC or GC automation - the extraction step and injection step are performed on-line using the same syringe. Reduces the volume of solvents needed. Works with samples as small as 10 µl versus several hundred µl for SPE. Sample Size and Sensitivity Sample volumes may be as little as 10 µl, or by taking multiple aliquots of 100 µl or 250 µl, samples of 1 ml or larger may be concentrated. Automation Extract samples and make injections on-line using a single device, reducing sample processing times and the need for operator intervention. Sorbent Life BIN life is dependent on the specific matrix being analyzed. For example, C18 analyzing whole plasma samples is conservatively 25-100 samples. BIN life of cleaner samples is significantly longer. Carryover The small quantity of phase in the MEPS BIN is easily and effectively washed between samples to reduce the possibility of carryover. This washing process is not practical with off-line SPE devices. With automation of MEPS, washing occurs while the previous sample is running. Flexible and Easy to Use The dimensions of the sorbent bed ensure performance remains identical to conventional SPE devices when used for extraction of similar samples. Using MEPS BINS for sample volumes as small as 3.6 µl make them well suited to on-line use with LC-MS analysis of volume limited samples. The MEPS BIN is easily installed in the syringe housing and then secured by the locking nut. Individual labeling of each BIN ensures the use of the correct stationary phase for each extraction. The amount of sorbent determines the maximum amount of analyte that can be retained. The capacity of non-ionic, silica-based sorbents can be estimated as 3 % to 5 % of the sorbent bed mass. MEPS has a sorbent bed mass of 4 mg so the capacity is: 4 mg x 3% = 120 µg 4 mg x 5% = 200 µg Conventional silica-based SPE products have a bed volume that can be estimated as 1.5 µl per mg of sorbent. MEPS uses 4 mg of packing so: 1.5 µl x 4 mg = 6 µl bed volume.

MEPS - Semi or Fully Automated Semi-automation of MEPS is achieved by coupling MEPS syringes to SGE s evol digital analytical syringe, speeding up repetitive SPE, and making it ideal for rapid method development. MEPS can also be fully automated by using MEPS XCHANGE syringes on autosamplers such as the CTC PAL* for on-line SPE and injection. * Contact your CTC distributor for configuration and hardware requirements. Meet Mighty MEPS! Fast Miniaturized SPE Together evol xr + MEPS = Mighty MEPS + = Mighty MEPS offers improvements in workflow and resource savings. evol xr custom programming semiautomates MEPS you control the speed and volume of each step making Mighty MEPS ideal for: Sample preparation. Method development. Sample clean up. How To Use Mighty MEPS Conditioning Reuse MEPS many times (dependent on matrix) Load Repeat load Small sample volumes Small volume solvent required Elute Inject the analyte directly into the injector Wash Remove unwanted analyte Ensure high recoveries evol The world s first digital analytical syringe

MEPS Performance Sample preparation for complex biological samples is readily adapted to MEPS, reducing the volumes of sample and reagents required for extraction. The extraction of xanthine metabolites from raw human urine using a MEPS BIN packed with C18, prior to GC-MS analysis, is shown in Figure 2. The extraction of anaesthetics from rat plasma using a MEPS BIN packed with C2, prior to LC-MS analysis is shown in Figure 3. EXTRACTION FROM PLASMA LIDOCAINE (2.4 µmol/l) ROPIVACAINE (2.5 µmol/l) BUPIVACAINE (3 µmol/l) 5.17 3.29 ABUNDANCE EXTRACTION FROM RAW URINE THEOPHYLLINE / PARAXANTHINE 2.18 THEOBROMINE RETENTION TIME (MINUTES) CAFFEINE 1 2 3 4 5 6 7 8 9 10 RETENTION TIME (MINUTES) Figure 2 Difficult matrices such as human urine are easily processed using MEPS. In this example 100 µl of human urine was aspirated through a C18 MEPS BIN (conditioned with methanol and water, water wash). Bound xanthines were eluted with 30 µl methanol, 2 µl injected on a BPX5 column for GC-MS analysis. Figure 3 Local anaesthetics were spiked into rat plasma samples - final concentrations: Lidocaine 2.4 µmol/l, Ropivacaine 2.5 µmol/l and Bupivacaine 3.0 µmol/l. 50 µl of the spiked plasma was aspirated through a C2 MEPS BIN, washed with water and eluted using 0.1% HCOOH in 25% Acetonitrile + 75% water onto a C18, 100 X 2.1 mm column. MEPS Applications MEPS has been used successfully in these industries: Environmental (Example: Determination of organic priority pollutants and emerging compounds in wastewater and snow samples) Forensics (Example: Contribution of microextraction in packed sorbent for the analysis of cotinine in human urine by GC-MS) Pharmaceutical (Example: Liquid chromatographic analysis of oxcarbazepine and its metabolites in plasma and saliva) Food and Flavor (Example: Determination of 2,4,6-trichloroanisole and 2,4,6-tribromoanisole in Wine) Life Sciences (Example: Rapid and Sensitive Method for Determination of Cyclophosphamide in Patients Plasma Samples). For an up to date list of published MEPS applications visit www.sge.com/products/meps

Mighty MEPS Custom Programmed Method Mighty MEPS Example Method - Caffeine Extraction from Saliva Step Mode Amount (µl) Speed Methanol Conditioning Caffeine in Saliva Mighty MEPS C18 Extraction 1 Aspirate 20 4 (20 µl/sec) 2 Dispense 20 4 3 Aspirate 20 4 4 Dispense 20 4 5 Aspirate 20 4 6 Dispense 20 4 H 2 O Equilibration 7 Aspirate 20 4 8 Dispense 20 4 9 Aspirate 20 4 10 Dispense 20 4 11 Aspirate 20 4 12 Dispense 20 4 Sample Bind 13 Aspirate 50 4 14 Dispense 50 4 15 Aspirate 50 4 16 Dispense 50 4 17 Select Mix x8 50 4 H 2 O Wash 18 Aspirate 20 4 19 Dispense 20 4 Saturated sodium tetraborate 20 Aspirate 20 4 21 Dispense 20 4 H 2 O Wash 22 Aspirate 20 4 23 Dispense 20 4 Air Dry 24 Aspirate 50 4 25 Dispense 50 10 (83 µl/sec) 26 Aspirate 50 4 Peak Area 400000 350000 300000 400000 250000 350000 200000 300000 150000 250000 100000 50000 200000 150000 0 5 7 9 11 13 15 17 19 21 23 25 min 100000 Caffeine extraction using Mighty MEPS method: 100 50000 µl evol MEPS syringe c18 MEPS BIN 140000 8 separate prompted functions 0 120000 33 steps total time: 5~ 3 minutes 7 9 11 13 15 17 19 21 23 100000 min 80000 60000 140000 40000 20000 120000 Peak Area 100000 0 80000 60000 40000 20000 0 Interoperator Repeatability 1 2 3 Repeat Extraction (3 operators) 1 2 3 Repeat Extraction (3 operators) Three different operators, two independent extractions, same day, same MEPS cartridge. 6 injections = 4.17 % RSD* * auto injector repeatability on 6 standard injections = 2.94 % RSD 27 Dispense 50 10 28 Aspirate 50 4 29 Dispense 50 10 Methanol Elute 30 Aspirate 20 4 31 Dispense 20 4 32 Aspirate 20 4 33 Dispense 20 4

Comparing MEPS Accuracy and Precision The precision and accuracy results obtained analyzing Ropivacaine by four sample preparation methods: MEPS, Liquid-Liquid Extraction (LLE), conventional SPE and Solid Phase Microextraction (SPME) are shown in Table 1. MEPS demonstrates improved precision and accuracy while taking significantly less time than SPME to process each sample. The accuracy, precision, limits of detection and extraction time of MEPS with two other µspe techniques, SPME and SBSE are compared in Table 2. The results from the MEPS and SBSE techniques are significantly better than SPME but MEPS processes each sample 100 times faster than SBSE. Table 1: Comparison of accuracy and precision between MEPS and other methods for ropivacaine (local anesthetics) Method Ropivacaine LOD (nm) Accuracy (%) Inter-assay) Precision (RSD%) Handling Time ([1] MEPS / GC-MS 2 105 5.0 1 min [2] LLE / GC-MS 2 101 3.8 20 min [3] SPE / LC-UV 100 101 3.0 20 min [4] SPME / GC-MS 5 110 6.3 40 min M. Abdel-Rehim / J. of Chromatography B, 801 (2004) 317-321 Table 2 : Comparison of accuracy and precision of MEPS, SPME and SBSE for the analysis of PAH s in water. Compound Accuracy (%) Compound Precision (RSD%) Compound Limit of detection (ng/l) Compound Extraction time (min) MEPS SPME SBSE MEPS SPME SBSE Anthracene 84 81 99 Anthracene 12 3 6 Chrysene 107 81 100 Chrysene 1 4 5 Fluoranthene 100 84 100 Fluoranthene 9 4 4 Fluorene 103 96 97 Fluorene 5 5 4 Pyrene 115 86 100 Pyrene 7 3 3 M. Abdel-Rehim / J. Chromatog. A 1114 (2006) 234-238 MEPS SPME SBSE Anthracene 5 100 1.2 Chrysene 5 90 0.2 Fluoranthene 5 100 1.2 Fluorene 1 40 0.7 Pyrene 1 40 0.7 MEPS SPME SBSE Anthracene 2 30 200 Chrysene 2 30 200 Fluoranthene 2 30 200 Fluorene 2 30 200 Pyrene 2 30 200 MEPS Extraction Comparison of LLE and SPE with MEPS Description Liq-Liq Extraction Liq-Solid Extraction MEPS Extraction Concentration of sample 5 ng/ml 5 ng/ml 5 ng/ml Extraction volume 1000 ml 20 ml 1 ml Volume of solvent used 150 ml DCM 3 ml DCM 0.04 ml DCM Concentration in solvent 33.33 ng/ml 33.33 ng/ml 125.00 ng/ml Final volume of extract 1 conc vol (ml) 0.2 conc vol (ml) Concentration in final volume 5000 ng/ml 500 ng/ml NO CONCENTRATION STEP REQUIRED Injection volume 1 µl inj 2 µl inj 2 µl inj Concentration of injection volume 5 ng per µl 0.5 ng per µl 0.125 ng per µl Concentration injection on column 5 ng 1 ng 0.25 ng Approx. time to prepare Extraction to injection ~2-3 hours Extraction to injection ~40-60 min Extraction to injection ~5-10 min Approx. volume of waste generated Waste Generated ~1+ Liter Waste Generated ~50 ml Waste Generated <2 ml Comparison Table SPE versus MEPS Sample Volume Time Price Solvents Evaporation Step SPE MEPS

Devices used for SPE are traditionally considered to be single use. The precision engineering used in the design and manufacture of MEPS allows for simple wash steps and consequently the re-use of the device. To demonstrate this, phenols were extracted from waste water and the carryover measured between experiments. The chromatograms for the three 10 µl extractions are shown in Figure 4. Clearly all of the phenols were eluted in the first 10 µl of Methanol used. One of the most often stated reasons for the use of disposable SPE BINS is the issue of carryover. Results from five studies are summarized in Table 3. With a series of washes, carryover was virtually eliminated. With a cycle time measured in seconds for MEPS this washing takes less than five minutes. To accomplish the same for conventional SPE takes an hour or more and uses significant quantities of solvents. Summary Table 4 summarizes the comparison of MEPS, SPME and conventional SPE. MEPS requires much less time than either SPE or SPME, and shows much better recovery and sensitivity than SPME. MEPS also eliminates any intermediate steps between the sample preparation steps and the injection into a GC or LC system. TIC 220000 2.4-dichlorophenol 2.4-dimethyphenol 2-chlorophenol phenol 4-chloro-3-methylphenol 2.4.6-trichlorophenol 3 5 7 9 11 13 RETENTION TIME (MINUTES) Extraction 1 Extraction 2 Extraction 3 Figure 4 Phenols at 25 ppb in alkane contaminated water. 10 x 100 µl cycles on C18 MEPS BIN (conditioned with methanol and water). Sample was eluted with methanol 10 µl, 2 µl injected onto a BPX5 column and analyzed by GC-MS. Table 3 : Comparison of carryover and wash regime. Wash Volume (ul) # of Washes and Wash Solution Carry-over Source PAHs in water 50 µl 4x methanol, 5x water 0.2% - 1% Anesthetics in human serum 50 µl 4x methanol, 4x water ~ 0.2% (I.S.) Roscovitine in plasma and urine 50 µl 5x methanol/water (95:5, v/v) 5x water/methanol (90:10, v/v) <0.1% Roscovitine in human plasma 50 µl 4x methanol, 4x water <0.01% Olomoucine in human plasma 50 µl 5x methanol/water (95:5, v/v) 5x water/methanol (90:10, v/v) <0.1% M. Abdel-Rehim / J. Chromatog. A 1114 (2006) 234-238 M. Abdel-Rehim / J. of Chromatography B, 801 (2004) 317-321 M. Abdel-Rehim / J. of Chromatography B, 817 (2005) 303-307 M. Abdel-Rehim / J. Mass Spectrom. 204; 39: 1488-1493 M. Abdel-Rehim et al. / Analytica Chimica Acta 2005 Table 4 : Comparison of MEPS BINs, SPME and conventional SPE. Factor MEPS BIN SPE SPME Amount sorbent 0.5-2 mg 50-2000 mg thickness 150 mm Sample prep. time 1-2 min 10-15 min 10-40 min BIN use 40 to 100 extractions Once 50-70 extractions Recoveries Good Good Low Sensitivity Good Good Low M. Abdel-Rehim / J. of Chromatography B, 801 (2004) 317-321

MEPS BIN Assembly Options for LC and GC Use Phase # per Pack LC Needle GC Needle Agilent 7693A - syringe P/N 005292 and 006293 C18 5 2900601 Silica 5 2900602 C8+SCX* 5 2900603 C2 5 2900604 C8 5 2900606 MEPS Development Kit (contains 1 each of C18, C8, C2, Silica and C8+SCX) 1 2900605 Thermo Scientific, HTA 300A Plus & Varian 8400 systems - syringe P/N 005291 and 006291 C18 5 2900401 2900101 Silica 5 2900402 2900102 C8+SCX* 5 2900403 2900103 C2 5 2900404 2900104 C8 5 2900406 2900106 SCX 5 2900408 SAX 5 2900409 MEPS Development Kit (contains 1 each of C18, C8, C2, Silica and C8+SCX) 1 2900405 2900105 CTC Analytics systems - syringe P/N 005291 and 006291 C18 5 2900501 2900301 Silica 5 2900502 2900302 C8+SCX* 5 2900503 2900303 C2 5 2900504 2900304 C8 5 2900506 2900306 SCX 5 2900508 SAX 5 2900509 MEPS Development Kit (contains 1 each of C18, C8, C2, Silica and C8+SCX) 1 2900505 2900305 Base material is silica with mean particle size of 45 µm and pore size of 60Å. *C8+SCX BINS are labelled as M1. For LC applications, needle is 22 gauge, 0.72 mm OD, dome point style. For GC applications, needle is 23 gauge, 0.63 mm OD, cone point style. For an up to date list of published MEPS methods visit www.sge.com/products/meps Mighty MEPS 1. Choose your evol xr - Electronic Syringe Description evol xr Electronic Syringe Starter Kit Contains: evol xr Electronic Syringe 3 evol xr Syringes 5 µl, 100 µl and 1 ml. Stand. Universal Charger. comprehensive Instruction Manual. Disc with Manual in Multiple Languages. 2910200 evol xr Electronic Syringe 2910205 2. Choose your evol MEPS Syringe by Volume Description Replacement Plunger Part No. # per Pack Syringe 50 µl for MEPS applications* 2910382 1 2910027 100 µl for MEPS applications* 2910383 1 2910028 500 µl for MEPS applications* 2910384 1 2910026 * The 50 µl, 100 µl and 500 µl evol MEPS syringes can be used with the range of MEPS BINs. 3. Choose your evol MEPS BINs by Phase Phase LC Needle GC Needle C18 2900701 2900711 C8 2900702 2900712 C2 2900707 2900717 APS - amino-propyl silane 2900703 2900713 DVB - hydrophobic polystyrene-divinylbenzene copolymer 2900705 2900715 SDVB - styrene-divinylbenzene 2900706 2900716 All LC needles are 55.5 mm in length, 22 gauge and dome tipped. All GC needles are 55.5 mm in length, 23 gauge and cone tipped. All packs contain 5 MEPS BINs and can be used with 50, 100 and 500 µl evol MEPS syringes. BR-0439-M SGE Analytical Science Pty Ltd 07/2012 AUSTRALIA & PACIFIC REGION SGE Analytical Science Pty Ltd 7 Argent Place, Ringwood Victoria 3134 Australia Toll Free: 1800 800 167 Tel: +61 (0) 3 9837 4200 Fax: +61 (0) 3 9874 5672 Email: support@sge.com JAPAN SGE Japan Inc RK CUBE 3F 6-85, Ohta-machi Naka-Ku, Yokohama-shi Kanagawa 231-0011 Japan Tel: +81 45 222 2885 Fax: +81 45 222 2887 Email: japan@sge.com EUROPE SGE Europe Ltd European Head Office 1 Potters Lane Kiln Farm Milton Keynes MK11 3LA United Kingdom Toll Free: 00800 2790 8999 Toll Free Fax: 00800 2626 2609 Tel: +44 1908 568 844 Fax: +44 1908 566 790 Tel France: +33 1 69 29 80 90 Fax France: +33 1 69 29 09 25 Tel Germany: +49 (0) 6155 / 60746 0 Fax Germany: +49 (0) 6155 / 60746 50 Email: europe@sge.com UNITED STATES OF AMERICA SGE Incorporated 2007 Kramer Lane Austin Texas 78758 USA Toll Free: (800) 945 6154 Tel: +1 512 837 7190 Fax: +1 512 836 9159 Email: usa@sge.com