Mean Time Between Failure MTBF. Mean Cycles Between Failure MCBF

Similar documents
Solid-State Relays (SSRs) vs Electromechanical Relays (EMRs)

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND

SPST-NO SPDT DPST-NO DPDT

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

Electromechanical Relays - Frequently Asked Questions

38 Series - Relay interface modules A

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

Application Note AN-1068 reva

FP2 Relay. The Best Relaytion

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

38 Series - Relay interface modules A

SPST-NO SPDT DPST-NO DPDT

Electromechanical Relays Selection Guide

Extreme Temperature Reed Switch Operation

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

LAUBE TECHNOLOGY DRY REED RELAYS

Proximity Switches RS (Reed Switch)

60 Series - General purpose relays 6-10 A. Features

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

The Best Relaytion. Reed Relays Rev. B EC-JM ECOC: JM10 1. Aug. 04

AZ420 MINIATURE GENERAL PURPOSE RELAY

Circuit Breakers. NRC Series. NRC Series

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

49 Series - Relay interface modules A. Features

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

Features: High reliability. Very sharp reverse characteristic. Zener voltage 3.3V to 12V. V z -tolerance ±5%.

1.5A Very L.D.O Voltage Regulator LM29150/29151/29152

General-purpose Relay

Model Number Structure

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

MasterINTERFACE 39 Series - Relay interface modules

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

Application Note TMA Series

MasterINTERFACE 39 Series - Relay interface modules

MADP T. Non Magnetic MELF PIN Diode

48 SERIES Relay interface modules 10 A

C ole s quality Open Frame Instrument Rotary Switch provides low

Data Sheet. Electro-mechanical counters Hengstler 800 series

RI-80 SMD Series Dry Reed Switch

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

APPLICATION NOTES. Bimetal Disc Thermostat. Operating Principle

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

Series AMLDL-Z Up to 1000mA LED Driver

PS323. Precision, Single-Supply SPST Analog Switch. Features. Description. Block Diagram, Pin Configuration, and Truth Table. Applications PS323 PS323

PIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages

T U R B I N E G A S M E T E R

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

Joslyn Clark Controls, Inc.

Model Number Structure

Aluminum Electrolytic Capacitors Power Eurodin Printed Wiring

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION TOR REED SWITCH

Wires & Connections Component Circuit Symbol Function of Component. Power Supplies Component Circuit Symbol Function of Component

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

NTE923 & NTE923D Integrated Circuit Precision Voltage Regulator

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

50 W Power Resistor, Thick Film Technology, TO-220

RC NETWORKS SALES GUIDE

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

MITSUBISHI RF MOSFET MODULE RA07H4047M

UMEC International Corporation

However, industrial applications may utilize a relay, which short-circuits the ICL path after the inrush sequence.

SPREAD SPECTRUM CLOCK GENERATOR. Features

Power Resistor Thick Film Technology

AN460 Using the P82B96 for bus interface

Features and Benefits

Three-phase monitoring relay CM-PFE

3-Channel Supervisor IC for Power Supply

Chapter 9 N.C. C. N.O. Single-Pole Double-Throw

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Section D..General Auto Electrical Corporation

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

Features. Applications. Truth Table. Close

First Year (Electrical & Electronics Engineering)

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

Vacuum Coaxial Relay. Catalog COA-99. A Danaher Company

Moving Magnet Actuator MI FFA series

MULTIFUNCTION TIME RELAY CRM-93H

LM139/LM239/LM339/LM2901/LM3302 Low Power Low Offset Voltage Quad Comparators

Aluminum Capacitors Solid Axial

DATA SHEET. PBSS5540Z 40 V low V CEsat PNP transistor DISCRETE SEMICONDUCTORS. Product data sheet Supersedes data of 2001 Jan Sep 21.

Hardware Specifications of V2AF Series Hybrid Card Reader

LCD-TV RELIABILITY TESTING AN EFFECTIVE APPROACH

HIGH REPEATABILITY SPDT, BROADBAND 12 GHZ MAGNETIC-LATCHING RF RELAY

LED Anti-Collision Lighting System for Airbus A320 Family

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

Parts list and Notes for making a 10 hp 240V single phase to 240V 3-phase converter.

Transfer Equipment Controls

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Short Circuit Current Calculations

Relays and Timers Specifications Bulletin Number 700

AIS-450 SYNCHRO CONVERTER

Transcription:

TELEDYNE RELAYS Mean Time Between Failure MTBF Mean Cycles Between Failure MCBF

MTBF applied to EMRs MTBF is an expression of reliability that attempts to predict the life expectancy of a device in hours Mean Time Between Failure). Any reliability expression for Electromechanical relays EMRs) must be predicated on the number of cycles. Thus the EMR equivalent to MTBF is MCBF Mean Cycles Between Failure). MTBF calculation using available in house data from MOQ For relays that are a part of an established reliability program, the empirical data of the MOQ Maintenance of Qualification) plan can be used to calculate the MCBF. This is done by using the failure rate level of the relay in question. MCBF may be calculated using the predetermined number of unit cycles called out in the reliability expression and dividing that by the number of allowable failures. MCBF = X% Once an MCBF level has been established, MTBF can be calculated by dividing the resulting MCBF by the number of cycles per hour MTBF = MCBF Cycles per hr or Unit operations Numbers of Failures Cycles per hr Using the above formula, the following generic MCBF levels for Teledyne Relays established reliability relays is given: For JAN L Level = 333,333.33 cycles M Level = 1,000,000.00 cycles For T 2 R A Level =,.7 cycles B Level = 1,333,333.33 cycles.03.01.01.007

This can now be translated into generic MTBF data by applying a cycle rate to the numbers. MOQ is performed at a cycle rate of 20±2 cycles per minute or a nominal cycle rate of 1,200 cycles per hour. Plugging this into the MCBF numbers we get: For JAN L Level = 333,333.33 cycles) = 27.7 hrs 1,200 cycles/hr) M Level = 1,000,000.00 cycles) = 833.33 hrs 1,200 cycles/hr) For T 2 R A Level =,.7 cycles) =. hrs 1,200 cycles/hr) B Level = 1,333,333.33 cycles) = 1,111.11 hrs 1,200 cycles/hr) When calculating MTBF for T 2 R or JAN relays, the formula should be modified to include the actual cycle rate used in a specific application. It should be noted that the cycle rate is the critical factor in MTBF as it directly relates to how quickly the number of contact cycles is accumulated by a given relay. Using the MCBF for T 2 R B level as an example, if we take the ± cycle rate tolerance 2 cycles per minute) into account this results in an MTBF window ranging from 1,010.10 hrs 22 cycles per minute) to 1,234.7 hrs 18 cycles per minute). MTBF calculation Per MIL-HDBK-217 MIL-HDBK-217 provides a calculation to help fine tune a reliability prediction as it applies to a specific application. It consists of the following formula: l p = l b, p L, p C, p CYC, p F, p Q, p E Failures/10 hours. MTBF = 10 hrs/l p Whereas: l b = Base Failure Rate temperature factor) p L = Load stress factor load level and type) p C = Contact form factor DPST, DPDT etc) p CYC = Cycling factor cycle rate) p F = Application and construction factor general relay load rating and armature type) p Q = Quality factor mil-spec qualification level vs. non mil) p E = Environment factor environment in which the relay is being used)

All of these factors have a numeric value associated with them that is to be chosen given a specific condition. These numeric values are obtained through the use of tables and/or calculation. Only l b, p L and p CYC allow for a calculated number that is then plugged into the formula. Even still, there are lists of standard values that can be used for these three factors. For example, l b, which is a temperature factor, has the temperature broken down into C increments. Depending upon the rating of the relay and the projected ambient temperature, a standard value is offered. If, however, the projected temperature is something other than the standard temperatures listed, 37. C for example, there is a formula provided to obtain a number to represent the temperature value. The same is true for p L and p CYC. When calculating for the p L value, one of the formula factors is S. S is found by dividing the relays rated resistive load into the load value that is actually being switched, regardless of whether the actual load type is resistive or not. In MIL-HDBK-217 the formula for solving l b and p L, appears slightly different than the formulas presented in tables 1 and 2 later in this application note. In MIL-HDBK-217 part of the argument for l b and p L is exp. exp in the MIL-HDBK-217 calculation is actually the Napierian number 2.7183 e). In tables 1 and 2 e is used rather than exp. p CYC and p Q are the only two factors in which a differentiation between mil spec and non mil spec, is made. In these two cases the user has discretion to decide into which category the subect relay will fall. As an example, T 2 R relays are not mil spec but are established reliability relays which encompass all mil requirements. Another example is a relay for space flight. Almost without exception, relays used in space flight applications start with a JAN relay of M level or better and expand the screening regimen. If p CYC and p Q were to be interpreted literally, spaceflight relays would be categorized as a lower reliability relay because they are not mil spec p F, or application and construction factor, have a number of conditions that could conceivably apply to an EMR. The Contact Rating portion that applies to the EMR is 0- Amp. The Application Type portion will be General Purpose. For Construction Feature, Armature Long) should be used for all non-magnetic latching relays. For all magnetic latching relays, the appropriate Construction Type is. MTBF levels obtained through calculation will differ greatly from the MTBF levels extracted from the established reliability statements as the claculation method takes into account varying load levels, operating conditions and armature styles. Following are tables taken from MIL-HDBK-217, Revision F, Change Notice 2.

Base Failure Rate l b T A C) Rated Temperature 8 C 1 12 C 2 2 30 3 40 4 0 0 70 7 80 8 90 9 100 10 110 11 120 12.009.007.007.0084.0094.010.012.013.014.01.017.019.021.009.00.0073.0081.0089.0098.011.012.013.014.01.017.018.019.021.022.024.02.027.029.031 1. l b =.009 e -.19 / 8.17 x 10 - [{1 / T+273} - {1 / 298}]) 2. l b =.009 e -.17 / 8.17 x 10 - [{1 / T+273} - {1 / 298}]) T A = Ambient Temperature C) Table 1

S Load Stress Factor p L Load Type Resistive 1 Inductive 2 Lamp 3.0.10.20.30.40.0.0.70.80.90 1.00 1.00 1.02 1.0 1.1 1.28 1.48 1.7 2.1 2.72 3. 4.77 1.02 1.0 1.28 1.7 2.72 4.77 9.49 21.4 1.0 1.28 7.72 9.49 4. 1. pl = ε S /..8) 2 2. pl = ε S /.4) 2 3. pl = ε S /.2) 2 S = Operating load current / Rated resistive load. For single devices which switch two different loads, evaluatp L for each possible load combination and use the worst case largestp L ). Table 2 Contact Form Factor p C Contact Form SPST DPST SPDT 3PST 4PST DPDT 3PDT 4PDT 8PDT p C 1.00 1.0 1.7 2.00 2.0 3.00 4.2.0 8.00 Table 3

Cycle Rate cycles per hour) Cycling Factor p CYC p CYC Mil Spec) > 1.0 Cycles per hour / 10 <1.0 0.1 Cycle Rate cycles per hour) p CYC Commercial Quality) >1,000 Cycles per hour / 10) 2 10-1,000 Cycles per hour / 10 <10 1.0 Note: Values of p CYC for cycling rates beyond the basic design limitations are not valid. Design specifications should be consulted prior to evaluation of p CYC. Table 4 Quality Factor p Q Quality R P X U M L Mil Spec, Non established reliability Comercial p Q.10.30.4.0 1.0 1. 1. 2.9 Table

G B G F G M N S N U A IC A IF A UC A UF A RW S F M F M L C L Environment G B G F G M Environment Factor π E π E 1.0 2.0 1 N S 8.0 N U 27 A IC A IF A UC A UF A RW S F M F M L C L Table 7.0 9.0 11 12 4.0 2 N/A Ground benign Ground fixed Ground mobile Naval sheltered Naval unsheltered Aircraft inhabited cargo Aircraft uninhabited cargo Aircraft inhabited fighter Aircraft uninhabited fighter Aircaft rotary wing Spaceflight Missile flight Missile launch Cannon launch

Application and Construction Factor p F see note at the end of the table) Contact Rating Application Type Construction Type p F Signal Current low mv and low ma) Dry circuit Armature long) Dry Reed Magnetic Latching Solenoid 4 1 4 7 7 0- Amp General Purpose Armature Long Solenoid Sensitive 0-100mW) Polarized Vibrating Reed High Speed Armature Long and Short) Magnetic Latching Meter Movement Armature Short Meter Movement Dry Reed Armature Balanced and Short) Dry Reed 3 2 100 10 10 100 Thermal Time Delay Bimetal 10 Electronic Time Delay, Non Thermal Latching Magnetic Dry Reed -20 Amp High Voltage Vacuum Glass) Vacuum Ceraic) Medium Power 2-00 Amp Contactors High Current Armature Long and Short) Magnetic Latching Solenoid Armature Short) Mechanical Latching Solenoid Note: While all condition for p F have been included in this table, only the conditions noted in italics apply to Teledyne Relays' Electromechanical relays. Table 7 1 2 9 10 20 3 1 2 2 2 7 12 10