The stable way. Synchronous condenser solutions. siemens.com/energy/facts



Similar documents
Mechanical and electrical rebuilding of a turbine generator for phase-shift operation

Siemens Steam Turbine-Generator SST-5000 Series. for combined cycle and subcritical steam applications. Answers for energy.

Transmission and distribution service level agreements

Power Island. Industrial Power Plants. / energy

Turbo generators Best quality for thermal power plants

Power Plant Electrical Distribution Systems

Answers for energy. The competitive edge in power network services

Electric Power Systems An Overview. Y. Baghzouz Professor of Electrical Engineering University of Nevada, Las Vegas

Monitoring, diagnostics, and cable services

Powerformer chosen for Swedish combined heat and power plant

The SGT5-8000H proven in commercial operation

A favorable investment in solar power

SYNCHRONOUS MACHINES

Basics of Electricity

Smarten up your last mile

POWER TRANSMISSION FROM OFFSHORE WIND FARMS

Siemens Generator Test Center Muelheim an der Ruhr, Germany

Excitation.

Power Transmission and Distribution. Shunt reactors for medium and highvoltage. From development to use

Power transformers. Phase shifting transformers Reliable and efficient power flow control

ABB PSPS Erich Steinmann; Generator control-2013

Synchronous motor. Type. Non-excited motors

Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP

A macro-economic viewpoint. What is the real cost of offshore wind? siemens.com / wind

Totally Integrated Power SIESTORAGE. The modular energy storage system for a reliable power supply.

A full range of monitoring solutions for surge arresters Answers for energy.

DC Traction Power Supply. Powerful, efficient and safe. siemens.com/mobility

WIND TURBINE TECHNOLOGY

Reactive Power and Importance to Bulk Power System OAK RIDGE NATIONAL LABORATORY ENGINEERING SCIENCE & TECHNOLOGY DIVISION

Siemens ENEAS solutions for substation automation and protection

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

Siemens Hybrid Power Solutions. Cost and emission reduction by integrating renewables into diesel plants

Motor Fundamentals. DC Motor

Power Plants. BENSON Once-Through Heat Recovery Steam Generator. Power Generation

This is a Master s degree level apprenticeship which includes academic learning combined workplace learning and training.

CO-ORDINATION OF PARALLEL AC-DC SYSTEMS FOR OPTIMUM PERFORMANCE

2012 San Francisco Colloquium

Generators TEM. for small hydroelectric power stations. Electric Machines

Solar Power Plant Design and Interconnection

Offshore Platform Powered With New Electrical Motor Drive System

FACTS. Solutions to optimise network performance GRID

Fast cycling and rapid start-up: new generation of plants achieves impressive results

Industrial Steam Turbines

Recent Siemens HVDC Activities Yuriy Kazachkov Siemens PTI

COMPARISON OF THE FACTS EQUIPMENT OPERATION IN TRANSMISSION AND DISTRIBUTION SYSTEMS

Federal Wage System Job Grading Standards for Electric Power Controlling, Table of Contents

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

Lab 8: DC generators: shunt, series, and compounded.

from Berlin Welcome to the Berlin gas turbine plant Answers for energy.

Smart solutions for fleets of all types & sizes of power generation. Marcus König, E F IE SGS / September 2013

Improving Flexibility of the Combined Cycle Power Plant Hamm Uentrop to Cover the Operational Profiles of the Future

AC COUPLED HYBRID SYSTEMS AND MINI GRIDS

MINISTERIE VAN ECONOMISCHE ZAKEN GENERAL COST COMPARISON BETWEEN UNDERGROUND CABLES AND O.H. LINE SYSTEMS FOR H.V. TRANSMISSION

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System

525-MVA Generator-motor and Thyristor Starter Put into Service at the Tokyo Electric Power Co., Inc. s Kannagawa Hydroelectric Power Station

Reducing Maintenance Costs Replacement of Small Fossil Generators in Russia

HVDC 2000 a new generation of high-voltage DC converter stations

Modern Power Systems for Smart Energy Society

Keywords: synchronous generator, synchronous motor, automatic voltage regulator, V- curves, synchronizing power, hunting, excitation system

EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID

Siemens Wind Turbine SWT The new productivity benchmark.

REMOTE MONITORING AND CONTROL OF THE KAKKONDA GEOTHERMAL POWER PLANTS

Siemens Gas Turbines over 100 MW

Unit 33 Three-Phase Motors

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

Brochure. Electric generators to power the world

L.I. Chubraeva. Corr. Member of RAS

Rotary Phase Converters

Asset Management Plans

Power System review W I L L I A M V. T O R R E A P R I L 1 0,

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only

NATIONAL CERTIFICATE (VOCATIONAL)

Appendix N: GENERATOR DATA SHEET FOR SYNCHRONOUS GENERATORS CONNECTED TO PG&E ELECTRIC SYSTEM

*ADVANCED ELECTRIC GENERATOR & CONTROL FOR HIGH SPEED MICRO/MINI TURBINE BASED POWER SYSTEMS

PMDD WIND TURBINE 1.5MW

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Wind Service Offshore. We can t conquer the elements But we can outthink them

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

Senoko Power Station CCP2 performance increase with focus on efficiency. Answers for energy.

Brochure Introducing HVDC

Large Generators and High Power Drives

MICRO HYDRO POWER GENERATING EQUIPMENT

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Siemens D3 platform 3.0-MW, 3.2-MW, 3.3-MW, and 3.4-MW direct drive turbines. Reduced complexity, increased profitability. siemens.

DIRECT CURRENT GENERATORS

Summary of Electric Transmission Assessment Report

PSS SINCAL efficient planning software for electricity and pipe networks. Siemens PTI Software Solutions. Answers for energy.

Steam turbines for solar thermal power plants. Industrial steam turbines. Answers for energy.

Monitoring and diagnostics

2012 San Francisco Colloquium

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

Thermal Modeling and Analysis of a Wind Turbine Generator

Power network telecommunication

Principles of Adjustable Frequency Drives

Annex-A TECHNICAL SPECIFICATION

S Y N C H R O N O U S G E N E R A T O R S

Replacement Generators to Modernize and Uprate Power Trains Limited by the Generator

Chen. Vibration Motor. Application note

Transcription:

The stable way Synchronous condenser solutions siemens.com/energy/facts

Bringing grids in line with new requirements Global climate change poses new challenges for power generation and transmission. Innovative solutions will contribute to the reduction in CO2 emissions and an optimized use of energy resources. The most crucial points in today s and tomorrow s power supply are sustainability, security, and efficiency. Synchronous condenser solutions are being introduced worldwide to support today s transmission system requirements. The addition of renewables-based power genera- tion to the energy mix, phaseout of conventional power plants, new HVDC systems, and the extension of power supply systems to remote areas influence the stability of transmission networks. Siemens offers tailor-made turnkey synchronous condensers to address the customers needs based on proven, reliable in-house equipment, extensive know-how on transmission system requirements, and project execution experience. 2

Benefits Short-circuit power capability Reactive power compensation Short-term overload capability Inertia to the transmission system Leveling out of»grid signals«support of grid to island operation capabilities Applications Synchronous condensers support and improve power transmission quality in a wide range of applications: Stabilization of grids High-voltage DC transmission links based on line-commutated converter technology Transmission grids with a high amount of power infeed from renewable sources Retirement/shutdown of conventional power plants 3

Technology and system overview Siemens synchronous condenser solutions comprise a horizontal synchronous generator connected to the high-voltage transmission network via a step-up transformer. Siemens supplies a broad range of generators up to 2,235 MVA. The generators are air-, hydrogen-, and water-cooled. The synchronous generator is started up and stopped by a frequency-controlled electric motor (pony motor) or a starting frequency converter. When the generator has reached an operating speed that is synchronous to the system frequency, it is synchronized with the transmission network and acts as a motor providing reactive and short-circuit power to the transmission network. Synchronous electrical machines like synchronous generators can generally be used as synchronous condensers. Without active power delivery or con sumption, the machines can act in the same way as a capacitor or a reactor, depending on the excitation field current. 9 5 8 4 1 3 7 2 1 Synchronous generator 2 Generator step-up transformer 3 Static/brushless excitation 4 Pony motor/starting frequency converter 5 Isolated phase bus duct 6 Control and protection system 7 Auxiliary transformer 8 Generator circuit breaker 9 Optional external coolers 10 Complete civil and construction works Siemens in-house equipment 6 10 System overview synchronous condenser solution 4

Proven, reliable in-house products Generators A generator is an electric machine that converts mechanical energy into electric power. It operates on the basis of the dynamoelectric principle that Werner von Siemens registered for a patent with the first dynamo generator in 1867. The principle states that an electric generator does not need to have an electric current supplied from the outside to start generating electric power. A self-reinforcing electrical induction can take place due to the residual magnetism of iron. Today, the mechanical excitation, the generator s need to generate electricity, is often provided by a turbine. It drives a shaft that is known as the rotor. This shaft rotates in the stator core, in other words, inside the generator. The rotor is equipped with an electromagnet, and the moving magnetic field of the rotor causes a charge transfer in the conductor coils of the stator. The charge transfer generates electric voltage between the ends of the conductors. This is how the mechanical energy, which acts on the rotor, produces electric energy power in the stator. Excitation systems The generator is equipped with either a brushless exciter or a conventional static exciter with brushes. The two solutions have different characteristics in terms of dynamic behavior, and are selected according to the project requirements. Contrary to power electronics-based static VAr compen sators (SVCs), a synchronous condenser features the major advantages of injecting large amounts of short-circuit power and providing inertia due to its rotating mass. The same generators are implemented for synchronous condenser applications. Starting frequency converter/pony motor The startup and breaking system of a Siemens synchronous condenser is either based on a frequency-controlled pony motor or a starting frequency converter. These two methods have different advantages and will be offered from Siemens own portfolio depending on the customer s requirements. Control and protection system Generator performance is dynamically controlled by an automatic voltage regulator (AVR), which is an integral part of all excitation systems. In a brushless excitation system, the AVR is separately installed, and in case of static excitation system, AVR software is integrated in the control system of the static excitation system. In addition to the AVR system, a generator control panel is required for start and stop sequences, protection of the generator (vibration and temperature) and for cooling system control. Segment cooling Nuc H2O 50 Hz 550 1300 MVA 1000 2235 MVA (4-pole) 60 Hz 800 1065 MVA Fossil H2 50 Hz 350 570 MVA 60 Hz 310 540 MVA 50 Hz 165 370 MVA Industrial Air 60 Hz 165 310 MVA 50/60 Hz 25 300 MVA 25 65 MVA (4-pole) Manufacturing of an air-cooled generator The Siemens generator portfolio 5

Project references Black Sea 3x60 MVAr, Republic of Georgia Siemens installed three 60 MVAr synchronous condensers at the Georgia Black Sea HVDC station in June 2012. This synchronous condenser solution supports the transmission network between Georgia and Turkey with the required short-circuit power in order to operate the newly installed HVDC back-to-back station. Bjæverskov 1x250 MVAr, Denmark In Denmark, Siemens delivered a 250 MVAr synchronous condenser solution that started operation in 2013, providing the transmission system with a short-circuit power of more than 800 MVA in addition to reactive power control. The installation of this stand-alone synchronous condenser solution will enable the transmission system operator Energinet.dk to operate the transmission network without the need for a large thermal power plant. This makes the installation an economically and environmentally advantageous investment enabling the infeed of large amounts of renewable energy into the transmission network. 6

Fraugde and Herslev 2x200 MVAr, Denmark These solutions will ensure the transmission system stability in the country s regions of Funen and Zealand. Siemens scope of supply comprises engineering, procurement, and construction of these facilities. The customer Energinet.dk will manage the civil work. Each synchronous condenser solution is capable of delivering more than 900 MVA of short-circuit power and +150 / -75 MVAr of reactive power. The projects are running in trial operation as of August 2014. Feda 1x200 MVAr, Norway This solution will secure short circuit power for the NorNed HVDC connection, especially during the planned upgrade of the overhead line in the southern region of Norway. Siemens scope of supply comprises engineering, procurement, and construction of these facilities including necessary civil works. The synchronous condenser solution for Feda is capable of delivering more than 750 MVA of short-circuit power and +170 / -90 MVAr of reactive power. The project is scheduled for trial operation at the end of 2014. Talega 2x225 MVAr, USA The turnkey supply of two 225 MVA synchronous condenser systems for Talega substation in California will support the California grid with reactive power, shortcircuit power, and inertia. Siemens scope of supply comprises the complete engineering, procurement, and construction of these facilities including necessary civil works. Each synchronous condenser solution for Talega is capable of delivering +225 / -120 MVAr of reactive power. The units are planned to commence commercial operation in July 2015. 7

Published by and copyright 2014: Siemens AG Energy Sector Freyeslebenstrasse 1 91058 Erlangen, Germany Siemens AG Energy Management Division Freyerslebenstrasse 1 91058 Erlangen, Germany For more information, please contact our Customer Support Center. Phone: +49 180 524 70 00 Fax: +49 180 524 24 71 (Charges depending on provider) E-mail: support.energy@siemens.com Order No. E50001-G610-A135-X-4A00 Printed in Germany Dispo 30003 fb 6407 WÜ 09141.0 Printed on elementary chlorine-free bleached paper. All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract.