Manual Software SPECTRO3-MONITORING V5.0

Similar documents
SA-9600 Surface Area Software Manual

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

Guide to Installing BBL Crystal MIND on Windows 7

Data Logging Software and Cable Bundle Model DL-SC3 User Manual. Overview

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS

SOFTWARE INSTALLATION INSTRUCTIONS

Korosi Monitoring System (KMS) Software Manual

Mapping ITS s File Server Folder to Mosaic Windows to Publish a Website

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

MONITORING PERFORMANCE IN WINDOWS 7

GUARD1 PLUS Mini-Attendant File Manager User's Guide Version 2.71

ScanWin Installation and Windows 7-64 bit operating system

Printer Sharing of the PT-9500pc in a Windows Environment

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

SAS 9.3 Foundation for Microsoft Windows

User Manual V1.0. Remote Software

STATISTICA VERSION 10 STATISTICA ENTERPRISE SERVER INSTALLATION INSTRUCTIONS

ThinPoint Quick Start Guide

Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts

Contents. Hardware Configuration Uninstalling Shortcuts Black...29

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

User Manual CROMLAWATCH. Data Logging Software. Version 1.6. For use with Color Sensors CROMLAVIEW CR100 CROMLAVIEW CR200 CROMLAVIEW CR210

Accounting Manager. User Guide A31003-P1030-U

DSG SoftPhone & USB Phone Series User Guide

StrikeRisk v6.0 IEC/EN Risk Management Software Getting Started

PCLinq2 Hi-Speed USB Bridge-Network Cable. Quick Network Setup Guide

LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)

SHORETEL CALL MANAGER Installation Instructions:

Installation Instruction STATISTICA Enterprise Small Business

Installing the Gerber P2C Plotter USB Driver

64-Bit Compatibility with Micromeritics Applications

VERITAS Backup Exec TM 10.0 for Windows Servers

Virtual Office Remote Installation Guide

Scan to SMB(PC) Set up Guide

IMDG Code for Intranet

Autodesk Product Manager Tool

Operating Instructions

STATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS

Using Avaya Flare Experience for Windows

NDA ISSUE 1 STOCK # CallCenterWorX-Enterprise IMX MAT Quick Reference Guide MAY, NEC America, Inc.

OralChroma OralChroma DataManager

Operating Instructions

Guest PC. for Mac OS X. User Guide. Version 1.6. Copyright Lismore Software Systems, Ltd. All rights reserved.

SOFTWARE GUIDE PM1405 DATA PROCESSING SOFTWARE

STATISTICA VERSION 11 CONCURRENT NETWORK LICENSE WITH BORROWING INSTALLATION INSTRUCTIONS

How to Install and Setup IIS Server

Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide

SPC-1. Single Point Controller. Operation Manual

How to setup a VPN on Windows XP in Safari.

MULTIFUNCTIONAL DIGITAL SYSTEMS. Network Fax Guide

Remote Monitoring and Control of the R&S FSV with a Web Browser

Getting Started with MozyPro Online Backup Online Software from Time Warner Cable Business Class

Installation Instruction STATISTICA Enterprise Server

IEI emerge and Milestone Systems Network Video Recorder. Setup and Integration Guide. Milestone Version 6.5 and emerge Version 3.

Installing OneStop Reporting Products

Set Up Setup with Microsoft Outlook 2007 using POP3

Introduction. Before you begin. Installing efax from our CD-ROM. Installing efax after downloading from the internet

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Zahner 08/2013. Monitor measurements in a separate window.

PRINTER DRIVER GUIDE (KODAK 305 Photo Printer)

File Management Utility User Guide

A-AUTO 50 for Windows Setup Guide

SNMP Example: DVM Management Center Monitoring in a Broadcast Network

Manual. Sealer Monitor Software. Version

Viewing and Troubleshooting Perfmon Logs

DUKANE Intelligent Assembly Solutions

Midland BT Updater BTUpdater Program Program file (x86) ), Midland

Working with SQL Server Integration Services

PTPhoneManager II. User guide

Supplement I.B: Installing and Configuring JDK 1.6

Installing the Microsoft Network Driver Interface

Windows 7 Hula POS Server Installation Guide

Appendix F: Instructions for Downloading Microsoft Access Runtime

Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide

13 Managing Devices. Your computer is an assembly of many components from different manufacturers. LESSON OBJECTIVES

Call Recorder Quick CD Access System

Central Management Software CV3-M1024

Call Recorder Oygo Manual. Version

Cyberex BCM-SFCM Configurator/Monitor User's Manual

IEI emerge and On-Net Surveillance Systems (OnSSI) Network Video Recorder Setup and Integration Guide

CANON FAX L360 SOFTWARE MANUAL

Como configurar o IIS Server para ACTi NVR Enterprise

Introduction to Windows XP

HOW TO INSTALL FS USB TRANSCRIPTION SOFTWARE (OFFICE ADMIN MEDICAL)

NETGATE Data Backup. User Manual. Document version 1. 1 EN ( ) Copyright (c) 2010 NETGATE Technologies s.r.o. All rights reserved.

LH110 Series DVR: Frequently Asked Questions

User Manual. Thermo Scientific Orion

Mercy s Remote Access Instructions

ScanShell.Net Install Guide

Advanced Aircraft Analysis 3.6 Network Floating License Installation

User and maintenance manual (client Web and Web services)

How To Backup Your Computer With A Remote Drive Client On A Pc Or Macbook Or Macintosh (For Macintosh) On A Macbook (For Pc Or Ipa) On An Uniden (For Ipa Or Mac Macbook) On

Chapter 1 Downloading Images to Your Computer (Windows)

The basic steps involved in installing FLEETMATE Enterprise Edition and preparing it for initial use are as follows:

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

PP8X Printer Driver Installation Instruction

Installation Guide - Client. Rev 1.5.0

XF Extracellular Flux Analyzer. Installation and Troubleshooting Guide

Transcription:

Manual Software SPECTRO3-MONITORING V5.0 (PC software for Microsoft Windows XP, VISTA, 7) for color sensors of the SPECTRO-3 series This manual describes the installation and operation of the SPECTRO3-MONITORING PC software version V5.0. The software was developed for configuring up to 8 color sensors of the SPECTRO-3 series in a multi-sensor system that can be used for the continuous inline measurement and control of surfaces at several measuring points at the same time. Measurement values are recorded and are also displayed at the PC monitor, and they can be printed out after the end of recording. The software concept provides two user levels: A password-protected administrator function for configuring the inline measurement system and for setting all the parameters for operation, and an easy-to-use user function that only allows the setting of the start and end of recording with input of production parameters (that have been determined by the administrator). The print function also is available for the normal user. As a support for commissioning and operation of the SPECTRO3-MONITORING software this manual explains the individual functional elements of the graphic Windows user interface. Sensor Instruments GmbH - Schlinding 11 - D-94169 Thurmansbang Tel.: +49 (0)8544 / 9719-0 - Fax: +49 (0)8544 / 9719-13 E-Mail: info@sensorinstruments.de - www.sensorinstruments.de

0 Contents 1 Installation of the SPECTRO3-MONITORING software... 3 Page 2 Operation of the SPECTRO3-MONITORING software... 4 2.1 Software description... 4 2.1.1 "File" menu... 4 2.1.2 "Configure" menu... 5 2.1.3 "Password menu... 8 2.1.4 "RunDataRecording" menu... 9 2.1.5 "Print" menu... 10 2.1.6 "ViewData" menu... 10 Shortcuts: SEND GET GO STOP F9 F10 F11 F12 SPECTRO3-MONITORING V5.0 (29.06.2012) 2

1 Installation of the SPECTRO3-MONITORING software Hardware requirements for successful installation of the SPECTRO3-MONITORING software: IBM PC AT or compatible PC VGA graphics Microsoft Windows XP, VISTA, 7 Serial RS232 interface at the PC Microsoft-compatible mouse Cable for the RS232 interface CD-ROM drive 20 MByte of free hard disk space The SPECTRO3-MONITORING software can only be installed under Windows. Windows must therefore be started first, if it is not yet running. Please install the software as described below: 1. The software can be installed directly from the installation CD-ROM. The CD-ROM contains a folder named INSTALL, where you can find a SETUP program. Start this SETUP program to install the software. 2. The installation program displays a dialog and suggests to install the software in the C:\ FILENAME directory on the hard disk. You may accept this suggestion with OK or [ENTER], or you may change the path as desired. 3. During the installation process a new program group for the software is created in the Windows Program Manager. In the this program group an icon for starting the software is created automatically. When installation is successfully completed the installation program displays a "Setup OK" message. 4. After successful installation the software can be started with a left mouse button double-click on the icon. Windows is a registered trademark of Microsoft Corp. VGA TM is a trademark of International Business Machines Corp. SPECTRO3-MONITORING V5.0 (29.06.2012) 3

2 Operation of the SPECTRO3-MONITORING software 2.1 Software description Please read this chapter before you start the process of initialising the software. When the SPECTRO3-MONITORING software is started, the following window appears on the Windows user interface. Depending on the settings in the "Startup Configuration File", various elements are displayed. 2.1.1 "File" menu In the "File" menu, configuration files that are set under "Configure" can be saved to a file or loaded from a file. The "Save As Startup Configuration File" item defines the currently set parameters as startup parameters, i.e. these parameters will be loaded automatically when the software is started. SPECTRO3-MONITORING V5.0 (29.06.2012) 4

2.1.2 "Configure" menu The "Configure" menu can be used for performing certain parameter presettings. A click on "Set Sensor Configuration" opens the following SENSOR CONFIGURATION PANEL: If data should be recorded from a sensor, the sensor must be activated with "ENABLE". In the "INSERT SENSOR NAME" field a name can be assigned to the sensor. This name will then be displayed in the main window, saved in the output file, and will also be printed. In the main window deltac is shown in a display and visualised in a graph. The MONITORING software calculates deltac with the following formula. deltac ( SetvalueX / s X / s)^2 ( SetvalueY / i Y / i)^2 ( SetvalueINT / M INT / M )^2 X/s, Y/i and INT/M are the current data coming from the sensor. The reference values SetvalueX/s, SetvalueY/i and SetvalueINT/M are preset in the SENSOR CONFIGURATION PANEL. FIXED SETVALUES allows the user to change the values in the main window while data recording is running. In the deltac TOLERANCE field a threshold can be set for the deltac graph in the main window. If the current deltac value exceeds this threshold, or if deltac=-1, the background of the graph and of the deltac display will turn red. The interface between a sensor and the PC is specified under "SELECT CONNECTION". SPECTRO3-MONITORING V5.0 (29.06.2012) 5

A click on "Set Product Parameter" opens the PRODUCT PARAMETER CONFIGURATION PANEL: There are 5 parameters that can be individually entered. All these data are fixed and are, if they are enabled, saved in the file and printed in the report. Parameters 6 to 10, if they are enabled, must be entered by the operator after pressing "Start. These data also are saved in the file and printed. Attention! The characters / \ :. *? " < > be used. must not Example: "ENABLE PRODUCT PARAMETER 6" is activated and is assigned the input of " Example Product Number. When "RunDataRecording" and "Start" is pressed, a window will appear prompting the operator to enter a Product Number. SPECTRO3-MONITORING V5.0 (29.06.2012) 6

A click on "Set Output Path" opens the OUTPUT FILE CONFIGURATION PANEL: This window is used for defining the output file. SAVE DATA TO FILE determines whether the data should be stored to a file, or whether they should be visualized only. If SAVE DATA TO FILE is not enabled, all setting possibilities will be faded out. If "OPERATOR CREATES FILENAME MANUALLY" is activated, the software, after the operated presses Start, prompts the operator to define an output file. If "CREATE FILENAME AUTOMATICALLY" is activated, the software automatically creates the output file. The output path is determined with "Output Directory". The file name comprises the activated "PRODUCT PARAMETER", the sensor name and the extension defined under "SELECT A FILE EXTENSION". Under SELECT DATA WHICH SHOULD BE SAVED TO FILE that data are selected, which should be stored. INFO! If the output file should be opened with Microsoft EXCEL, the regional settings in Windows should first be set to an Anglo-American country (Great Britain, USA,...). The reason for this is that EXCEL interprets a number with comma as a date information. If the file is saved in Anglo-American mode and the regional settings are then set back to your respective country, EXCEL will recognise a number with comma correctly. If the file is saved in the Anglo-American mode, and if the regional settings are then set back to the respective country, EXCEL recognises the gloss factor as a floating point number. The following steps must be performed to change to an Anglo-American language: Start Settings Control Panel Regional and Language Settings An Anglo-American language can then be selected in the "Regional Settings" tab. SPECTRO3-MONITORING V5.0 (29.06.2012) 7

A click on "Select Record Mode" opens the RECORDER CONFIGURATION PANEL: This window is used for determining the data recording mode. With "AUTO LIMITED", an adjustable number of data is recorded after an adjustable time interval. With "AUTO UNLIMITED" data are recorded after an adjustable time interval until recording is stopped by pressing "Stop". With "AUTO TRIGGERED" the sensor automatically sends data which are then recorded and saved. Attention! For using the "AUTO TRIGGERED" function the sensor must operate in one of the trigger modes, because data only are sent when the trigger condition drops (cf. instruction manual SPECTRO3-Scope). 2.1.3 "Password" menu The "File" and "Configure" items can be protected by a password. Password protection can be enabled and disabled. The default password is: 0000000000 (in words: 10 zeros). The password can be individually changed. When password protection is enabled, the menu items "File" and "Configuration" only can be accessed after pressing "Deactivate Password Protection" and entering the correct password. Attention! Password protection must be activated again with "Activate Password Protection". SPECTRO3-MONITORING V5.0 (29.06.2012) 8

2.1.4 "RunDataRecording" menu In this menu item data recording can be started with "Start" and stopped with "Stop". Data recording furthermore can be paused with "Pause" and then continue again with "Continue". When "Start" is pressed, the product parameters 6 to 10 that are enabled in "Set Product Parameter" must be entered. If "OPERATOR CREATES FILENAME MANUALLY" is activated under "Set Output Path", the operator will be prompted to specify a file. The data that are selected in the OUTPUT FILE CONFIGURATION PANEL are immediately saved in the correspondingly created file, if this is activated, and are visualised on the screen. The CNT display shows the total number of recorded values. The current values of X/s, Y/i, INT/M, and deltac are displayed in the respective fields left of the graph. The SETVALUES for X/s Y/i and INT/M that are set in the SENSOR CONFIGURATION PANEL are displayed above the graph. If FIXED SETVALUES is deactivated in the SENSOR CONFIGURATION PANEL, the SETVALUE function elements have a white background, and the current values that are shown in the display fields can be directly adopted as SETVALUES with a right-click on one of the function elements. The deltac tab provides a display that in a graph visualises deltac and the deltac TOLERANCE that is set in the SENSOR CONFIGURATION PANEL. If the current value of deltac exceeds the tolerance threshold, the background of the graph and of the deltac display will turn red. The X Y INT / s i M and RGB tabs provide a graphic representation of the current values of X/s, Y/i and INT/M and of RGB (red, green, blue), respectively. For memory capacity reasons the graphs only show the last 1000 values. The output file, however, contains all the values. A click on the RESET button sets the graphs in all three tabs to zero. SPECTRO3-MONITORING V5.0 (29.06.2012) 9

2.1.5 "Print" menu A stored configuration file can be selected and printed by pressing "Print Configuration Data". "Print Monitoring Data" prints the activated product parameters and a screenshot of the current user interface. 2.1.6 "ViewData" menu For reasons of space only 4 sensors can be displayed on a screen. "Page1" and "Page2" can be used to toggle between the first 4 and the last 4 sensors. "Page3", however, displays the delta C and the C-No. of all 8 connected sensors. Attention! The display only shows the sensors that are set to enabled. SPECTRO3-MONITORING V5.0 (29.06.2012) 10