WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1



Similar documents
Below are detailed instructions for using the EMS load calculator.

HVAC Calculations and Duct Sizing

Duct Design. Presented by Dave Janquart

How to Measure HVAC System Airflow

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

Building Performance Solutions HVAC Design Guide, 2007

Basics of HVAC Cleaning

DUCT DESIGN FOR THE TIME CONSTRAINED WORLD

Cased/Uncased Coils For Gas And Oil Furnaces

Glossary of Heating, Ventilation and Air Conditioning Terms

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM

How To Install A Perfect 16 Id Series Filter System

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Fan Applications & System Guide

HVAC System Installation & Best Practices in New Construction. Anthony Stamatopoulos ACI New Jersey

HVAC Basic Science - System Capacity

HVAC Air Duct Leakage. November 2013 Presented By: Mark Terzigni Project Manager Technical Services SMACNA

Innovent LASER Packaged Fresh Air Conditioning Units

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Residential Duct Systems for New and Retrofit Homes

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Performance Rating of Room Fan- Coils

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

HVAC Systems: Overview

Cooling Capacity CFM in. w.c. (125 Pa)

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

F9MXE. Product Specifications

Commissioning - Construction Documents (Page 1 of 6)

AABC Specifications for Testing and Balancing HVAC Systems

DUCT SYSTEM DESIGN CONSIDERATIONS Part 1

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

Heating Load HERS: Calcs Duct Seal and Test (h), (m)1-3 & 11

TECHNICAL MANUAL GDS8 & GHS8

How To Design An Hvac Design For A Stick Built Home

ECHO System for Basements

Characteristics of Evaporators

Glossary of HVAC Terms

Ventilation Standard For Health Care Facilities

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Air-Conditioning Buying Guide

Energy Efficiency. Energy Efficient Home Cooling:

ENERGY STAR Program Requirements for Residential Air Source Heat Pump (ASHPs) and Central Air Conditioner Equipment. Partner Commitments.

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Residential HVAC System Sizing

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Basic Selection & Proper Application of Overhead Air Distribution Devices

Commercial Gas Furnace Upflow

G9MXE. Product Specifications

HVAC FORMULAS. TON OF REFRIGERATION - The amount of heat required to melt a ton (2000 lbs.) of ice at 32 F. 288,000 BTU/24 hr. 12,000 BTU/hr.

Massachusetts COOL SMART. RESIDENTIAL CENTRAL AC/DUCTED AIR SOURCE HEAT PUMP Rebate Application

PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE

Balancing of a water and air system

Chapter 8. Duct Design and Sealing

Rating Water-Source Heat Pumps Using ARI Standard 320 and ISO Standard

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

SMALL DUCT HIGH VELOCITY COMFORT SYSTEM

THREE. Heating and Cooling


SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

heating 3 & cooling heating and cooling 2010 PulteGroup, Inc. All Rights Reserved.

Sensitivity of Forced Air Distribution System Efficiency to Climate, Duct Location, Air Leakage and Insulation

LOW-RISE RESIDENTIAL BUILDINGS ADDITIONS AND ALTERATIONS IN EXISTING LOW-RISE RESIDENTIAL BUILDINGS

Air Conditioning Contractors of America

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

Greensource iseries HY Model Unitary Air Handler/Fan Coil

FIRE DAMPER APPLICATION GUIDE

york air-conditioning products Residential & VRF News 2015

New Homes EPS Modeling Frequently Asked Questions. Developed by Energy Trust of Oregon

How To Test A Building For An Icc 2006 Test Case

Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

Answers to Your Questions from the Webinar

INSTALLATION MANUAL RESIDENTIAL GAS FURNACE. MODELS: TG9S*MP, GG9S*MP (95.5% AFUE Single Stage Multi-position) LIST OF SECTIONS LIST OF FIGURES

ARMSTRONG AIR HEAT PUMPS

HVAC Checklist - Long Form

Certification Information. Qualifications. Test Specifications. Air Conditioning Industry References

HVAC SYSTEMS ACOUSTICAL, COST & ENERGY STUDY

BVCAA inc HVAC Service Bid Sheet Item Description. Materials Labor Total 3/24/2015

A Glossary of HVAC Terms:

Dehumidification Frequently Asked Questions

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

COMMERCIAL HEATING VENTILATION & AIR CONDITIONING (HVAC)

Why Daikin? 2015 Houston, Texas USA

Residential Air Conditioning. Program Standards

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects

CENTRAL HEAT PUMP AND AIR CONDITIONER INSTALLATION

GCS16 GCS20 WARNING CAUTION

This permit does not include replacement or upgrading of the existing electrical panel or service (a separate electrical permit must be obtained).

Electrostatic or Electronic: Know the Facts By Robert P. Scaringe, P.E., Ph.D., ---President of Mainstream Engineering

Topics for Today. Order of Magnitude Mechanical Estimating. Order of Magnitude Estimate Goal. Project Delivery Methods. Questions for Client

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Design Calculation or Analysis Cover Sheet. Complete only applicable items M8C-VCTO B

Transcription:

WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1 Wallet card photocopy Inspection Authority: Signature: Date: / / Submitted For: ( Owner ) Name Address City Prov Postal code Phone ( ) Fax ( ) Designer/Signature: Phone: ( ) Fax ( ) Date: / / By: ( Contractor ) Name Address City Prov Postal code Phone ( ) Fax ( ) Designed Equipment: ( Heating ) Designed Equipment: ( Accessories ) Gas furnace Electronic air cleaner Oil furnace Pleated air cleaner Propane furnace Electrostatic air filter Electric furnace Dry media filter ( thickness ) Heat pump Merv filter Water coil & blower Water heating coil Designed Equipment: (Cooling ) Electric heating coil Indoor coil Other Outdoor Unit Ventilation System ( Integrated ) Air handler System type : Other Mixed air temperature F Forms available from: HRAI * 2800 Skymark Avenue * Building 1* Suite 201 Mississauga, Ontario * L4W 5A6 Reproduction in any form by mechanical means is forbidden. Copyright by: The Heating Refrigeration and Air Conditioning Institute of Canada. ( Feb 2014 )

PART A - DESIGN LOAD SPECIFICATIONS page 2 A.1 Sub Total Heat Loss Btuh. A.2 Ventilation Heat Loss Btuh. A.3 Total Heat Loss (A.1 + A.2) Btuh. A.4 Sub Total Heat Gain Btuh. A.5 Ventilation Heat Gain Btuh. A.6 Total Heat Gain (A.4 + A.5) Btuh. A.7 Volume of House: Air leakage (Aflb) X (Average Ceiling Height) cu ft. A.8 Ventilation Flow Rate: As per Heat Loss/Gain Worksheet cfm. PART B EQUIPMENT SELECTION Heating Equipment: Cooling Equipment: Make Model Make Model (Outdoor Unit) Fuel Type: Gas Oil Electricity Other Make Model (Indoor Unit) B.1 Heating Output (Minimum 100% - of A.3) B.2 Approved Temperature Rise/range F. Btuh. Cooling Medium: DX Chilled Water Other B.5 Cooling Output (80% - 125% of A.6) Btuh. Tons B.3 Equipment External Static Pressure in. W.C. B.6 Manufacturers Flow Rate/Ton (cfm/ton) B.4 Heating Air Flow Rate (blower specs) cfm B.7 Cooling Air Flow Rate. Target Air Flow rate = B.5 X B.6 cfm Actual Air Flow Rate (blower specs) cfm B.8 Coil Pressure Drop, in. W.C. Dry: Wet: Speed setting: Adjustment: Speed Setting: PART C AIR DISTRIBUTION & PRESSURE Adjustment: C.1 Circulation Air Flow Rate ( A.7 x 0.025 ) cfm C.5 Calculated Heating Temperature Rise [ B.1 (B.4 x 1.08) ] F C.2 System Design Air Flow Rate (highest of B.4, B.7, C.1) cfm C.6 Filter Pressure Drop in. W.C. C.3 Cooling Airflow Proportioning Factor Calculate to 4 decimal places (B.7 A.4) cfm/btuh C.7 Coil Pressure Drop (B.8) in. W.C. C.4 Heating Airflow Proportioning Factor Calculate to 4 decimal places C.8 Total of Pressure Drop (C.6 + C.7) in. W.C. C.9 Available Design Pressure (B.3 C.8) (C.2 A.1) or (B.4 A.1) cfm/btuh or Selected Design Pressure in. W.C. Note: When furnace standard filter is replaced, subtract its pressure drop from the replacement filter and record on line C.6

PART D - DETERMINING ROOM AND FLOOR DESIGN FLOW RATES page 3 D.1 Floor D.2 Room D.3 Cooling load (Btuh) D.4 Room cooling flow rate (D.3 x C.3) D.5 Heating load (Btuh) D.6 Room heating flow rate (D.5 x C.4) D.7 Number of outlets per room D.8 Floor supply air flow rates (greatest airflow heating or cooling) PART D - CONTINUED D.1 D.2 D.3 D.4 D.5 D.6 D.7 D.8 PART E - INLET FLOW RATES Floor level (Location) E.1 Floor return air flow rate E.2 Minimum number of openings E.3 Actual number of openings Basement (50% D.8 Max) 1st floor (Sum of D.8 Min) 2nd floor (Sum of D.8 Min) 3rd floor (Sum of D.8 Min) E.4 Actual cfm per opening ( E.1 E.3 ) Note: After location of supply outlets and return inlets are determined, produce preliminary drawing. Total = ( C.2 ) (System cfm)

PART F - SUMMARY OF TOTAL EFFECTIVE LENGTHS FOR RETURN DUCTS page 4 Inlet No Equipment Connection (Group 1) To Drop Connection (Group 1) Transitions (Group 2) Fittings (Group 2) Duct To Joist (Group 3) Turbulence Effect Stud To Joist (Group 4) Grille Opening To Stud (Group 4) Measured Branch Effective PART G - DUCT DESIGN PRESSURE G.1 (Return Branch Longest Effective Length ft). G.2 R/A Plenum Pressure: Available Design Pressure (Line C.9) x Return Air Apportioning Factor (Appendix C (C3)) ( ) x ( ) = in. W.C. (Record Line H.8) G.3 S/A Plenum Pressure: Available Design pressure (Line C.9) - R/A Plenum Pressure ( ) - ( ) = in. W.C. (Record Line J.7)

PART H - SIZING OF RETURN GRILLES, BRANCHES AND MAIN TRUNK DUCTS page 5 H.1 Letter/No H.2 Inlet Location (Room) H.3 Inlet No (R) H.4 Inlet flow rate (cfm) (Line E.4 adjusted) H.5 Minimum required inlet free area (sq. in.) (Appendix C8) H.6 Inlet size (Appendix A) H.7 Inlet Pressure Loss (in. W.C.) H.8 R/A Plenum pressure (in. W.C.) (Line G.2) H.9 Adjusted duct design pressure (H.8 - H.7) H.10 Branch effective length (ft) (Part F) H.11 Loss/100 ft. of effective length [(H.9 x 100) H.10] H.12 Branch duct size (round) (H.4, H.11) (Appendix C4,5) H.13 Branch rectangular equivalent (Appendix C6) H.14 Joist to trunk opening size (2 x area H.13) H.15 flow rate (cfm) accumulation of H.4 H.16 Lowest loss/100 ft encountered from duct end. H.17 duct size (round) (H.15, H.16) (Append C4,5) H.18 rectangular equivalent (Appendix C6) H.19 Installed size (Transitions) H.20 velocity (fpm) fpm = [(cfm x 144) area]

PART I - SUMMARY OF TOTAL EFFECTIVE LENGTHS FOR SUPPLY DUCTS page 6 Outlet No Plenum Fitting (Group 5) Transition (Group 6) Fittings (Group 6) To Branch Take offs (Group 7) Aspiration Effect Duct Flex Branch Elbows (Group 8) Boot Fitting (Group 8) Measured Branch Effective

PART J - SIZING OF SUPPLY DIFFUSERS, BRANCHES AND MAIN TRUNK DUCTS page 7 J.1 Letter/No J.2 Outlet location (Room) J.3 Outlet No (S) J.4 Outlet flow rate (cfm) (Line D.6 D.7) (Heating) J.4b Outlet flow rate (cfm) (Line D.4 D.7) (Cooling) J.5 Outlet size J.6 Outlet pressure loss (in. W.C.) J.7 S/A Plenum pressure (in. W.C.) (Line G.3) J.8 Adjusted duct design pressure (J.7 - J.6) J.9 Branch effective length (ft) (Part I) J.10 Loss/100 ft of effective length [(J.8 x 100) J.9] J.11 Branch duct size (round) (J.4, J.10) (Appendix C4,5) J.12 Branch rectangular equivalent (Appendix C6) J.13 flow rate (cfm) accumulation of J.4 J.13b flow rate (cfm) accumulation of J.4b J.14 Lowest loss/100 ft encountered from duct end. J.15 duct size (round) (J.13, J.14) (Appendix C4,5) J.16 rectangular equivalent (Appendix C6) J.17 Installed size (Transitions) J.18 velocity (fpm) fpm = [(cfm x 144) area]

PART J - CONTINUED page 8 J.1 J.2 J.3 J.4 J.4b J.5 J.6 J.7 J.8 J.9 J.10 J.11 J.12 J.13 J.13b J.14 J.15 J.16 J.17 J.18