Telemetry system for cathodic protection equipment of underground metal pipelines



Similar documents
REMOTE MONITORING AND CONTROL SYSTEM

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

Tecnosystem Group Srl - Pietro Fiorentini Spa

Proactive Monitoring of Friction Management Systems Reduces Costs and Downtime

SCADA and Monitoring for Solar Energy Plant

reduction ore = metal oxides metal oxidation

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Remote monitoring & control solutions for cathodic protection rectifier

Features: RMU REMOTE MONITORING UNIT AND WEB-BASED SOFTWARE

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series

Tecnosystem Group was founded in 1988 for operating in the field of

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Introduction to OmniMetrix

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

TORKEL 820 Battery Load Unit

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller

German Cathodic Protection REMOTE MONITORING AND CONTROL

HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic

Cathodic Protection. Remote Monitoring of Cathodic Protection on a Gas Distribution Network

Security Alarm Systems

MPR-Systems. Mini Power Racks 1200 W W

Model: DC-A2IO Advanced HVAC Controller

is then retained absolutely without interruption.

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012

OPERATIONS CAPITAL. The Operations Capital program for the test years is divided into two categories:

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Rack mounted telephone- and leased line modem for industrial applications

Home Passport Gateway Series Simplify your Life with Smart Solutions

WIRELESS INSTRUMENTATION TECHNOLOGY

Monitoring Remote Chemical Tanks

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

MCOM VEHICLE TRACKING SYSTEM MANUAL

THE TOWN OF GROTON IS REQUESTING PROPOSALS FOR A WIRELESS ALARM MONITORING AND CONTROL SYSTEM WITH INTERNET BASED DATA ACCESS

Cathodic Protection Use On Tank Bottoms & Underground Piping In Power Generation Plants

Uninterruptible Power Supply

Technical Information POWER PLANT CONTROLLER

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Table of Contents. TransformerIQ FAQs 1

CONSULTATION PAPER FOR PROPOSED MODIFICATIONS TO THE TRANSMISSION CODE

FUNCTIONAL SPECIFICATION FOR AN ADVANCED METERING INFRASTRUCTURE VERSION 2

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

Permissible ambient temperature Operation Storage, transport

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

MINIMUM QUALITY INDICATORS FOR ALL TYPES OF LEASED LINES

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Homologation Directive for Tracking System for Two-Wheeled vehicles

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Wireless Data Logger Monitoring Systems

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Application. Key Features. Benefits. Contact us. Solution for Digital TV coverage. Multi DVB-T/-H/-T2 - & ISDB-T Gapfiller Nx1W

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

Temperature & Humidity SMS Alert Controller

RRV934. Multi-controller. Synco living

MoniUPS Software and Service. with an expert

User manual Rev 1.3 Contents

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

Table of Contents. 1. Product Overview Proposed Solution System Architecture Key Modules & Features...

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Indoor / Outdoor Antenna

Radiological Assessment Display and Control System

Advanced Fencing and Security Technologies Ltd

Remote Monitoring and REC 501 Control Unit Product Guide

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

TereScope Management Options

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Module 4, Lesson 12 Fire Alarm Systems

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

NortechCommander Software Operating Manual MAN R6

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

Advanced Fuel Cells A Reliable and Green Solution to Reduce Operating Expenses of Telecommunication Networks

Can I Cost-Effectively Monitor Critical Remote Locations?

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Premium Server Client Software

PLC GPRS NET Data Logger

Telephone- and leased line modem for industrial applications TD-36


CC Family of Data Collectors

Installation Manual for D0700 ISDN Analogue Converter

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Executive Summary. Technical Description

SiteRanger tm. Power quality / site monitoring. Comm/net Systems, Inc.

CalMod Design-Build Electrification Services

ISO IEC ( ) INFORMATION SECURITY AUDIT TOOL

When Do Solar Electric & Utility Back-Up Systems Make Sense?

Mobile Data Power Model: MDP-25

Transcription:

RECOMMENDATION PCRA 009 June 2010 Rev. 0 Committee for Cathodic Protection and Associated Coatings Telemetry system for cathodic protection equipment of underground metal pipelines DISCLAIMER: The present recommendation has been consensually established by the members of the committee Cathodic protection and associated coatings of CEFRACOR. It reflects the general opinion in the trade and might be used as such as a basis representing at the best the state of art at the date of issue. Nevertheless, it shall not commit in any manner the CEFRACOR and the committee members by whom it was established. 1. Scope Buried metal pipelines can be fitted out with cathodic protection equipment in order to protect them from corrosion by reducing the corrosion rate to an acceptable limit as well as from a technical as an economical standpoint (cf. EN 12954, Cathodic protection of buried or immersed metallic structures - General principles and application for pipelines). The proper operation of the equipment and the effectiveness of the protection are periodically assessed over the entire structure under the responsibility of each network operator. These inspections are periodically carried out by cathodic protection specialists within a framework defined in standard EN 12954. In order to optimize his internal organization, each network operator can install a remote monitoring system on the cathodic protection equipment. The purpose of the present recommendation is to define what a remote monitoring system for cathodic protection of underground metal pipelines is and to provide the main characteristics of such a system. The rules defined in this Recommendation are in accordance with those of standard EN 12954. 2. Interest of a remote monitoring system Standard EN 12954 edition 2001 (cf. table 2) defines the periodical functional field checks to be carried out on different equipment of the cathodic protection system unless a telemetric system is used. Moreover, it defines the main principles of a telemetric system: Functional checks: If the cathodic protection system is monitored by remote control, such that equipment malfunctions can be immediately detected, then the frequency of functional checks laid out in Table 2 do not apply. Effectiveness of cathodic protection: It is possible to have a better overview of the cathodic protection system if the effectiveness of cathodic protection is monitored by remote control. In this case potential and current measurements may be performed on demand, automatically at pre-set intervals, or when an alarm condition exists. 1

However, the standard does not define the periodicity of functional field checks of the cathodic protection equipment in the case that a telemetric system is installed. The installation of a telemetric system on its equipment provides multiple benefits for the operator of the protected structure: - Ensure that his cathodic protection equipment are operational, - Ensure that his cathodic protection equipment provide the regulatory required level of cathodic protection of his structure, - Increase the reactivity in case of failure of a cathodic protection equipment, - Enhance the historical knowledge of the cathodic protection system of the structure, - In general, reduce the operation and maintenance costs by allowing less frequent field checks and measurements. 3. Definitions and symbols 3.1 Definitions Cathodic protection equipment can be: - Remotely monitored, - Remotely measured, - Remotely controlled, - Remotely adjusted, - Remotely operated. These five actions above comprise the telemetry. Remote monitoring: Remote transmission of information regarding the state of operation or the trip of a system by means of a telecommunication system. Remote measurement: Remote transmission of one or more measured values. Remote control: remote control, by a binary signal, of operation of cathodic protection equipment. Remote adjustment: remote modification of the setting of a cathodic protection equipment. Remote operation (or remote management): remote measurement + remote monitoring + remote control. Manager of the cathodic protection: entity responsible for the cathodic protection activities. 3.2 Symbols The designation of the symbols used in this document is according to standard EN 12954. a.c. : alternating current d.c. : direct current MC : metallic coupon 1 U p : voltage over the terminals of a direct current generator 1 I p : protection current supplied by a direct current generator E on : On potential E off : Off potential U diode : voltage over the terminals of a diode 1 I diode : current flowing through a diode 1 1 This symbol does not feature in standard EN 12954 neither in standard ISO 8044. 2

I anode : current flowing through a galvanic anode 1 I bond : current flowing through a bond 1 4. Cathodic protection equipment that can be fitted out with telemetry The cathodic protection equipment that can be associated with a tele monitoring system includes: - impressed current station, - polarized bond including current drainage station, - electrical bonds between structures, - grounding systems for the drainage of induced or conducted alternating current on the structure, - protection systems (such as lightning arresters, voltage surge arresters) against accidental dc or ac voltage surges, - galvanic anode, - potential test point, possibly associated with equipment (such as a coupon, a metal casing ). 5. Data to be tele-transmitted Data to be transmitted can be carried by different means of communication: telephone networks, GSM, specialized links, ADSL, satellite, pipeline, GPRS. The table below shows a non exhaustive list of data to be considered in a telemetry system. However, for each device, the cathodic protection manager will determine those he whishes to implement for his system. Table 1: Data to be tele-transmitted Remote monitoring Remote measurement Remote adjustment monitored by a on/off contact include : - open door, - burnt fuse, - a threshold to be defined (e.g. I p, U p, E on or E off ). Duration of failure can be associated with the monitored parameter (delayed alarm). monitored by a on/off contact include : - open door, - burnt fuse, - a threshold to be defined (e.g. I diode, E on,.). Duration of failure can be associated with the monitored parameter Rectifiers - I p - U p - E on - E off Polarized bonds - I diode, - U diode, - E on structure, - E off structure, - E foreign structure / soil or E foreign structure / structure (E rail road/soil or E rail road/structure in Parameters that can be remotely adjusted as a reference value: - I p, - U p - E on, - E off. Not applicable Remote control Putting into or out of operation of a rectifier, a cyclical circuit breaker. Putting into or out of operation of a bond 3

(delayed alarm). monitored by a on/off contact on a threshold to be defined (e.g. I anode, E on or E off ). the case of a current drainage station). Galvanic anodes - I anode, - E on, Not applicable Not applicable monitored by a on/off contact on a threshold to be defined (e.g. I bond, E on, E off, ). Duration of failure can be associated with the monitored parameter (delayed alarm). monitored by a on/off contact include : - open door, - a threshold to be defined (e.g. I bond a.c., I 2 bond d.c., U ac pipeline, E on, ). Duration of failure can be associated with the monitored parameter (delayed alarm). monitored by a on/off contact on a threshold to be defined (e.g ; E on, I TM, E off ). Duration of failure can be associated with the monitored parameter (delayed alarm). - E off Bond with foreign structure (resistive or direct) - I bond, - E on, - E off. a.c. grounding system - I bond a.c., - I bond d.c., - U a.c. pipeline, - E on, - E off. Potential test point - E on, - I MC, - E off, - U a.c., - Parameter related to additional equipment. Not applicable Not applicable Not applicable Putting into or out of operation of a bond Not applicable Putting into or out of operation of a cyclical circuit breaker 6. Description A remote monitoring system shall enable to: - record at least once per day the proper operation from parameters (cf. table 1) and selected equipment, - in case of confirmed malfunction of the cathodic protection equipment (cf. table 2), transmit information to the cathodic protection manager within the by him defined maximum timeframe, 2 In normal operation, the I bond d.c. equals zero. In case of short circuit of the filter, a d.c. current will flow in the bond, which is very detrimental for the cathodic protection of the buried pipeline. 4

- in case of normal operation, transmit information of proper operation to the cathodic protection manager within the by him defined maximum timeframe, A remote measurement system shall enable to: - record all selected variables (cf. table 1), within the maximum lapse of time defined by the cathodic protection manager, on networks not subject to stray currents. The remote measurement system originates data that can be either directly accessibly or indirectly by means of statistical values calculated over a defined period of recording (at least: the minimum, maximum and average values), - record, during a sufficiently long period, and with a suitable scan rate, all selected variables, within the maximum lapse of time defined by the cathodic protection manager, on networks subject to stray currents. The remote measurement system originates data that can be either directly accessibly or indirectly by means of statistical values calculated over a defined period of recording (at least: the minimum, maximum and average values), - transmit recorded information to the cathodic protection manager within a by him defined maximum delay, A remote measurement system may be associated with a remote monitoring system. The transmission of the measurements can be carried out either directly through the remote measurement system, or on request (automatically or manually) by the cathodic protection manager. A remote control system shall enable to remotely change the operational state of a cathodic protection equipment (start/stop of a rectifier, remotely start/stop of a cyclical switching device, ). A remote adjustment system shall enable the remote modification of the settings of a current rectifier. It shall enable to carry out remote measurements. Any reference to periodicity, scan rate or measured value is irrelevant. Type of equipment Rectifier Polarized bond Galvanic anode Bond with foreign structure (resistive or direct) a.c. grounding system Selected potential test point 3 Not selected potential test point Table 2: Examples of failures according to the type of equipment Examples of failures - Protection current not in accordance with a preset threshold, - Protection potential Eon not in accordance with a preset threshold, - Voltage over the terminals of the rectifier not in accordance with a preset threshold. - Bond current not in accordance with a preset threshold during a preset period, - Inversion of the current flow direction in the bond. Protection current not in accordance with a preset threshold. Cathodic protection current not in accordance with a preset threshold, possibly during a preset period. - A.c. current in the ground bond not in accordance with a preset threshold during a preset period, - D.c. current not equal to zero. - Protection potential E on not in accordance with a preset threshold, - Current in an internal bond not in accordance with a given threshold. - Protection potential E on not in accordance with a preset threshold, - Current in an internal bond not in accordance with a given threshold, - Protection potential E off not in accordance with a preset threshold, during a preset period. 3 This involves test points selected as meant in standard EN 12954 (cf. 10.3.3.2 a 1). 5

7. Delay of information transmission The delays of transmission of data and alarms vary according to the telemetry system and the internal organization of the company using the system. On should distinguish the delay of transmission of data (such as measurements) from that of an alarm (signaling the failure of equipment of the cathodic protection system). In all cases the maximum transmission delay shall be defined by the cathodic protection manager as specified in 5. The possible or probable severity of a failure of the remotely monitored equipment may also affect the choice of the transmission delays. For the choice of the transmission delay one shall also take into account the capability of responding to the alarm: e.g. it is inconsistent to collect data in real time if an intervention cannot be scheduled in less than a month. In the case that the on-site monitoring campaigns are totally or partially substituted by the remote measurement systems, the transmission delays shall be comply with the minimum requirements in the regulation. Note : It is recommended to take into account the delays of intervention which will be added to the delays of transmission. However, the present document does not address the delay of intervention further to the notification of an anomaly by the telemetry system. 8. Periodicity of field measurements and checks of cathodic protection equipment Standard EN 12954 (cf. table 2) defines the periodicities of field checks on cathodic protection equipment in absence of a telemetry system. Several philosophies are possible. The cathodic protection manager can implement either exclusively remote monitoring or exclusively remote measurement or remote monitoring with associated remote measurement. This can be completed with remote control and/or remote adjustment. If the telemetry involves exclusively remote monitoring, then it can only substitute the verification of proper operation of the cathodic protection equipment. However it will not replace the detailed and comprehensive assessments to be carried out on-site. In this case it is recommended to comply with the periodicities defined in standard EN 12954 for these detailed and comprehensive assessments. If the telemetry involves remote measurement (with or without associated remote monitoring), the periodicities of the assessments to be carried out on site can be increased with regard to those defined in standard EN 12954. The operator who decides to increase the field checks of a network or part of a network shall be able to justify this decision. The justification shall particularly take into account: - the number and type of measurement points equipped with remote measurement (rectifier, potential test point,..), - the characteristics of the network (length of the involved pipelines, defined limits of the network, absence of foreign electrical influence on the network,..), - the level of effectiveness of the CP which shall comply with the criterion defined in standard EN 12954, - the control of the level of the cathodic protection. 9. Characteristics to consider for the choice of a telemetry system Table 3 synthesizes the different parameters to be considered in order to guide the choice of a telemetry system. 6

Table 3: Parameters to be considered and the related description for selecting a telemetry system Item Parameters Description Remarks 1 Type of telemetry 2 3 4 5 Type of cathodic protection equipment Dimensions of the telemetry devices Parameter to be measured or monitored Type of power supply Remote monitoring, remote measurement, remote control, remote adjustment, remote operation, - Rectifier, - Drainage station, - Potential test point with or without equipment (test coupon), - Electrical bond, - Galvanic anodes, - Electrical grounding (for a.c. current drainage). To be agreed up on between the client and the supplies. See Table n 1. - mains, - battery, possibly associated with solar panels, Permanent or temporary telemetry according to the type of equipment (rectifier, test point, ). Dimensions compatible with the equipment to be monitored. - Accumulator life time, - Autonomy of the accumulators or batteries, - Vandalism, geographical et environmental situation for the location of solar panels. - turbo generator - turbines powered by a fluid. - ATEX area or not, 6 Environmental conditions - Ambient relative humidity, - Allowable operating temperatures, - Corrosive environment or not, - Degree of Ingress Protection by enclosure (IP). The allowable operating temperatures shall be compatible with the ambient temperatures 7 Information communication system - GSM or GPRS, - PSTN network - Pipeline, - ADSL (PSTN or optical fiber), - Wi-Fi, - Problem of area coverage, - Existing network, - Loss of signal depending on the distance, - Existing network, - Limited range of the signal, - Radio waves, - Limited range of the signal and reliability issue, - Satellite. - Cost of transmission. 7

- Required number of channels, - a.c. or d.c. data to be acquired for each channel, - Range of each channel, - Suitable range for the measurement of the involved parameter, 8 Technical characteristics of the remote measurement channels - Scan rate, - Input impedance of each channel, - Scan rate compatible with the requirements of the CP manager - Typically : 10 MΩ for a spot potential measurement, 100 MΩ for a permanent potential measurement. Very low for a current measurement. - Typically : 200 to 1000 V between two channels in order to avoid interference on the measurements, - Insulation of the channels. - Increase the electrical power consumption. 9 Technical characteristics of the remote monitoring or remote control channels - Discrete binary input - Discrete binary output - Voltage threshold at the input of the remote monitoring circuit board, - Interruption capacity of the remote control relay or circuit board. - Volatile or permanent memory of the recorded data, - A permanent memory allows avoiding loss of information in case of malfunction. 10 Memory 11 12 13 External communication ports Details regarding the acquisition of the measurements Data management - Memory size, - Type of support of the memory. The type and number of external parts shall comply with the requirements of the CP manager - Accuracy to be defined with the CP manager, - Metrological follow-up to be defined with the CP manager. - Processed directly by the CP manager by means of an information processing software installed at his premises, - Depending on the chosen management process, a removable support enables reading the recorded data on another device - Ethernet ports for network access, - Serial ports for communication, - Bus for extensions, of digital and analogical inputs for connection of a laptop (not exhaustive), - Typically: 1 % of full scale of the channel, - Self auditing system possible. - Requires backup and archiving of data 8

- Processed by the telemetry system supplier. In this last case information is accessible through Internet. - Possibility to remotely modify, via internet, the threshold settings, the frequency of retrieval of the measurements. - Defer to the supplier the responsibilities for data storage, backup, and protection - Possibility to secure the transmitted data. 14 Data export format The software shall allow exporting data by means of a format usable by the cathodic protection manager. Examples of formats: XML, ASCII, SQL, CSV, XLS. 15 Technological developments Compatibility of existing hardware and software with technological developments. The configuration shall be defined with respect to the means of data analysis of which the CP manager disposes 16 17 Configuration of retrieved data - Complete transmission of recorded data. Protection against accidental potential surges 18 Maintenance 19 Guaranty - Statistical processing over a defined lapse of time (e.g. one day) : minimum, maximum, average, standard deviation, out of range time. - Archiving of statistical values, number of alarms, out of range time - Interest to dispose of his own protection device - Compatibility with that of the equipment on which it will be installed - Maintenance contract established with the supplier or the service provider, - Maintenance carried out by the client. - Duration of the guaranty, - Guaranty conditions (hardware, software, data transmission, data backup, guaranty exclusions, ). - Possibility to obtain spot records and zooms. The installed telemetry equipment shall comply with standards EN 62305-3 (Protection against lightning- Damage to structures) and 62305-4 (Protection against lightning-electrical and electronic systems). NOTE: the telemetry equipment shall have an adequate protection against lightning and a good CEM in order to allow its installation (low failure frequency). 9

20 Training To be detailed in the contract if needed. 21 22 23 Type of contract regarding the hardware After sales service Supplier references 24 Miscellaneous - Proprietary system, - Leased system. - Sustainability of spare parts supply over a defined period, even after ceasing the manufacturing of the equipment. - Number of equipment already installed, - Client portfolio - Technical assistance from the supplier to be defined in the customer-supplier contract. - Follow up of the equipment by the CP manager, - Rely on the service provider. 10