ISI-501 Series Off-Grid Solar Inverter User Manual

Similar documents
User s Manual Before using the inverter, you need to read and save the safety instructions.

VLT Series 300 Watt True Sine Wave Inverter

3000W Power Inverter

YSmart Technology Co.,Ltd

12 Volt 30 Amp Digital Solar Charge Controller

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Online UPS. PowerWalker VFI 1000R/1U

User s Manual AURORA 1.2K/2.2K

Battery Power Inverters

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

How To Use A Power Supply Unit (Upu)

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

Home Solar Kit Owner s Manual. Model: HS

HM-W536 Install Guide

10000HXL31/15000HXL31/20000HXL31

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Advantium 2 Plus Alarm

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

Installation and Operation Back-UPS 1250, 1300, 1500

Mobile Data Power Model: MDP-25

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

USER MANUAL Online UPS 1K/2K/3K Rack

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

USER MANUAL GEBRUIKSAANWIJZING MODE D'EMPLOI BEDIENUNGSANLEITUNG

Emergency lighting units EM powerled

Antec TruePower User's Manual

USER MANUAL Online UPS 1K/2K/3K

TruPower-Portable-500W. Solar Starter kit

Manual. Solar Fountain Mobile Phone Charger

E Manual N Phoenix

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

victron energy USER MANUAL GEBRUIKSAANWIJZING MODE D'EMPLOI BEDIENUNGSANLEITUNG Phoenix 12/220 Phoenix 24/220 Phoenix 48/220

User Manual HomeGrid 3000 Solar Generator

ST Series POWER SUPPLIES USER INSTRUCTIONS

INSTALLATION & SERVICE MANUAL. Display Panel

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Powerware 5110 UPS User s manual

GWS250 Series Instruction Manual

Home Solar Kit Owner s Manual. Model: HS

Charge Regulator SCR 12 Marine

WD-AMX Water Detection Controllers

BB800 Off-Grid Solar System

Installation and operating instructions. Solar charge controller Solarix MPPT Z Z

User Manual for CH-PFC76810

User Manual 1K/2K/3K Online UPS

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

Manual for Fire Suppression & Methane Detection System

Photovoltaic Solar Energy Unit EESFB

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

650W Single Output Power Supply

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

ADM1TE 5/30A DIN rail single phase two wire energy meter

MCR1900 Media Converter 19-Slot Chassis

Back-UPS Pro 1300/1500 Installation and Operation

How To Control A Battery Cell Phone With A Battery Power Control System

SOLAR POWER CONDITIONER Service Manual

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

LOXONE 12 Channel Amplifier

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

Uninterruptible Power Supply

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

TIG INVERTER INSTRUCTION MANUAL

BroadBand PowerShield. User Manual

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Problem / Solution. The problem:

350, 500, 650 and 1000 MODELS

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

1500 WATT POWER INVERTER

Tone Hammer 500. Owners Manual. Manual Version 1.0

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

EKOS Cart. Instructions for Use

FOXAIR 60/50 ALL MODELS

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

USER MANUAL Online UPS 6K/10K RACK

Configure Inverter output for two utility settings, (1)120V/60Hz, (2)220V/50Hz

750 WATT Power Inverter

SECURITY SYSTEM ADP-CAN

ekil 3 KGK tecrübesi olmayan herhangi bir ki i tarafından çalı tırılabilir.

Antenna Splitter ASA 1. Instruction manual

AC-DC BATTERY CHARGER 120~326W Portable Battery Charger 300~1000W Stationary Battery Charger

AutoRanging Digital MultiMeter

Switch Mode, Automatic, Lead Acid Battery Charger 3 Stage (IUoU)

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

Transcription:

ISI-501 Series Off-Grid Solar Inverter User Manual

Off-Grid Solar Inverter User Manual Table of Contents 1.Safety Guidelines... 1 2.Introduction... 1 2.1 Features... 1 2.2 Main Specification... 2 3.User Interface Panel... 2 3.1 Front Panel... 2 3.2 LED indicator on Front Panel... 3 3.3 Rear Panel... 3 4.Output Voltage and Frequency Settings... 4 4.1 Initial Factory State... 4 4.2 Procedure to Change Output Voltage and Frequency... 4 5.Operating... 6 6.Protection... 7 6.1 Input Protection... 7 6.2 Output Protection... 7 7.Installation & Wiring... 7 8.Troubleshooting... 10 9.Warranty... 10 Mar. 2014 Version 1

1.Safety Guidelines (Please read through this manual before assembling the Inverter) Risk of electrical sho ck and energy hazard. All failures sho uld be examined by a qualified tec hnician. Please do not remove the case of the inv erter by yourself! Please do not install the inverter in places with high moisture or near water. Please do not install the inverter in places with high ambient temperature, under direct sunlight, or near fire source. Plea se o nly con nect batteries w ith t he s ame bra nd and mod el num ber in on e battery bank. Using batteries from different manufacturers or different capacities is st rictl y prohibited! Never allow a spark or flame in the vicinity of the batteries. Make sure the airflow through the fan is not obstructed on both sides (front and back) of the inverter. (Please keep any objects clear from the fan at least 15cm) Please do not stack any objects on the inverter as it may impede heat dissipation. Please t urn off the inverter through the power ON/OFF switch, before removing the battery. WARNING: Batteries will have aging problems after years of operation. It is suggested to execute regul ar battery maintenance (e.g. every year). Once aged, the batteries should be changed by a professional technician, or the failed batteries may cause fire or other hazards. Inverter Inverter Inverter Inverter Don't disasse mble Keep away from moistu re Keep away from fire or high temperature Don't stack on the inverter Keep good ve ntilation 2.Introduction ISI-501 is a true sine wave DC/AC off- grid inverter equipped with a solar charger (with Maximum Power Point Tracking, or MPPT) which is digitally controlled by an advance d microprocessor and incorporates a high frequency des ign. This high performance inverter can be paired with both battery and PV modu les / pan els. ISI-501 can provide 500W pure sine wave output continuously, 550W for 1 minute, and sustain a peak load of 1000W as long as 30 AC power cycles. ISI-501 adopts a high frequency design which greatly reduces product weight and improves efficiency up to 88%. ISI-501 has a built-in solar charger with the MPPT function which effectively utilizes energy from the PV modu le. ISI-501 progresses the concept of a m iniature independent power station. It is ideal for areas where the power mains is absent but PV modules are available. 2. 1 Features 500W rated output Surge power capability up to 1000W True sine wave (THD<3%) 1

AC output voltage regulation : ± 3% High effic iency up to 88% Built in MPPT solar charger, MPPT efficiency: 98%(Typ.) Adjustable output voltage and frequency LED indication for operation and battery capacity Battery low alarm (with electrically iso lated dry contact) Remote ON/OFF function Compliance to FCC / CE regulations 3 year warranty 2. 2 Main Specification MOD EL INVERTER SECTIO N OUTPUT INPUT BATTERY SECTION MPPT / SOLAR SECTIO N 112 124 148 2 12 224 248 RATED POWER 4 50W 500W 450W MAXIMUM OUTPUT POWER (Typ.) 550W for 60 sec. / surge power 1000W for 30 cycles (112, 212 models : 495W for 60 sec. / surge power 900W for 30 cycles) AC VOLTAGE FREQ UENCY 100 / 110 / 115 / 120VAC selectable bysetting button S.W 200 / 220 / 230 / 240VAC selectable by setting button S.W Factory setting set at 110VAC Factory setting s et at 230VAC 50± 0.1Hz 50/60Hz selectable by setting button S.W WAVEFORM True sine wave ( THD<3% ) at rated input voltage AC REGULATION ±3% FRONT PANEL INDICATOR Inverter status, Charger status, Battery capacity BAT. VOLTAG E 12V 24V 48V 1 2V 24V 48V VOLTAGE RANGE DC CURRENT (Typ. ) OFF MODE CURRENT DRAW EFFICIENCY (Typ.) 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 50A 30A 15A 5 0A 30A 15A NO LOAD CURRENT DRAW 1.25A 0.63A 0.32A 1.25A 0.63A 0.32A 1mA OVER TEMPERATURE OUTPUT OUTPUT SHORT PROTECTION OVER L OAD (Typ.) Factory setting set at 110VAC 60± 0.1Hz 50/60Hz selectable by setting button S.W 85% 87% 87% 86% 88% 8 8% Shutdown o/p voltage, re-power on to recover Shutdown o/p voltage, re-power on to recover 110% load for 60 sec. Protection type : Shut down o/p voltage, re-power on to recover 3.Main Spec ification 3.1 Front Panel A AC Output Outlet: To satisfy global demands, there are many optional AC outlets to choose from. 500W Factory setting s et at 230VAC CHARGER CURRENT ( Typ. ) 30A 17A 8.5A 30A 17A 8.5A BATTERY TYPE Open & sealed Lead Acid F USE 40A*2 40A*1 20A*1 40A*2 40A*1 2 0A*2 BAT. LOW ALARM 11V 22V 44V 11 V 22V 4 4V BAT. LOW SHUTDOWN 10.5 V 21V 42V 10.5V 21V 4 2V REVERS E POLARITY By internal fuse open MPPT CHARGER EFFICIENCY (peak) 98% OPEN CIRCUIT VOLTAGE RANGE 35 ~ 50V 45 ~ 90V 90 ~ 160V 35 ~ 50V 45 ~ 90V 90 ~ 160V MPPT RANGE 25 ~ 50V 35 ~ 90V 70 ~ 160V 25 ~ 50V 35 ~ 90V 70 ~ 160V SOLAR INPUT CURRENT (Typ. ) 11A SOLAR INPUT POWER (Typ.) 500W 7A 4.5A 11A 7A 4.5A Receptacle type Country Certificate TYPE-A Standard TYPE-B Standard TYPE-C Optional TYPE-D Optional TYPE-E Optional TYPE-F Optional USA EUROPE AUSTRALIA U.K JAPAN GFCI TYPE-U Optional UNIVERSAL Non 2

B LED Indicator (Status): Displays the operation status of the ISI-501. C LED Indicator (Battery): Displays remaining capacity of battery. D E F Function Setting: Output voltage and frequency can be set through this button. Power ON/OFF Switch : The inverter will turn OFF if the switch is in the OFF position. Ventilation Slits: The inverter requires good ventilation for proper operation and for prolonging its lifetime. E A O N AC OUTPUT F O FF Stat us Battery Setting B C D Figure 3.1 Front Panel( Type A) 3.2 LED Indicator On Front Panel Operation Status Indicator (Status LED) : Represents the current ISI-501 state. LED Display Green Orange Red Status Normal Operation Remote Off Error *Note : When an error occurs, please refer to chapter 8 "Troubleshooting" of the user manual. Battery Capacity Indicator ( Battery LED) : Represents the remaining capacity of external batteries. LED Display Battery Capacity Green >70% Orange 40 ~ 70% Red <40% 3.3 Rear Panel A Battery Input(+),(-): Pay extra caution to battery polarity whe n wiring. B C Fan Ve ntilation Opening: The inv erter require s good ventilation fo r proper operation and for prolonging its lifetime. Remote ON/OFF Control: While set at ON, the ISI-501 can be powered ON/OFF through remote control. Connector Status Open Short Inverter Status Remote ON Remote OFF 3

D E F Battery Low Alarm: This is an electrically isolated dry contact which can provide the user with an external control signal. Users will be alarmed of a low battery when the two pins are open and the ISI-501 makes a "beep" sound. PV Input Terminal(+),(-): Pay extra caution to PV module polarity when wiring. Grounding Terminal(FG). C Battery Status Battery Low Battery Normal D B Connector Status Connector Open Alarm "Beep" Sound Connector Short ----- Rem ote ON/OFF Batter y low alarm BATTERY INPUT A F SOLAR INPUT Reverse Polarity Will Damage T he Unit. E Figure 3.2 Rear Panel 4.Output Voltage and Frequency Settings 4.1 Initial Factory State Initially the ISI- 501 is set to output 110Vac at 60Hz or 230Vac at 50Hz. 4.2 Procedure to Change Output Voltage and Frequency The user can adjust the output voltage and frequency through the function setting button on the front panel. A fter changing the settings, the inverter will re star t and adopts the setup the user entered. Even if the battery is removed at a later time, or if there is no source of power, the inverter will keep the most recent setup. Step 1: The inverter should be turned off while resetting. The input batteries should be connected and the loads should be remov ed. Step 2: Use an insulated stick to press down on the setting button and then turn on the power; the panel's orange LED should flash. After pressing for 5 seconds, the inverter will send out a "beep" sound. Users can release the button and go on with the setting procedure. Step 3: Check output voltage and frequency with table 4-1. If the output is desired, please continue to s tep 5; if not, please continue adjusting according to step 4 until it is. 4

ON AC OUTPUT OFF Status Ba tter y Se tting Use an insulated plast ic st ick to press on t he "Set ting" button Figure 4.1 Adjusting output voltage and frequency Table 4-1 Voltage & Frequency Chart O/P Voltage 100Vac 110Vac 115Va c 120Vac Frequency (200Vac) (220Vac) ( 230Vac) (240Vac) 50Hz Status Red Red Red Red Battery Green Green Yellow Yellow 60Hz Status Red Red Red Red Battery Green Green Yellow Yellow Light Flashing Step 4: Press the setting button for around 1 second before letting it go. The LED indicators (Table 4-1) will change with status. Please adjust accordingly. 100Vac (200Vac) 50Hz 110Vac (220Vac) 50Hz 120Vac (240Vac) 60Hz 115Vac (230Vac) 50Hz 115Vac (230Vac) 60Hz 120Vac (240Vac) 50Hz 110Vac (220Vac) 60Hz 100Vac (200Vac) 60Hz Figure 4.2 Output voltage & frequency changing sequence Step 5: When the output is at user's desired value, press and hold the setting button for 3~5 seconds until the inverter makes a "beep" sound. The output setting is now complete; the inverter will now save the settings and restart. 5

5.Operation System On (SW-ON) Battery Low Shutdown Protection Auto Recovery AC Output Battery Voltage t 14.4/28.8/57.6V 13/26/52V Charger Status OFF ON OFF ON t1 t2 t3 t4 t5 t6 t7 Figure 5.1 Operation Sequence OFF 10.5/21/42V t1: When user turns on the ISI-501, battery voltage will be sensed. If battery voltage is greater than 13/26/52V, it means the battery is adequately charged and the charger circuit will remain de-activated to prevent overcharging. t2: While the ISI-501 operates, battery voltage will slowly drop; when battery voltage is lower than 13/26/52V, battery low signal will be detected and the charger will automatically activate and charge accordingly. t3: If the power provided by the PV module is greater than the load consumption, the battery voltage will increase. When this battery voltage reaches 14.4/28.8/ 57.6V, the charger circuit will stop charging the battery modules to prevent the batteries from overcharging. t4: When battery voltage drops to 13/26/52V again, the charger will automatically restart the charging action. t5: If the power provided by the PV module is less than load consumption, even if the charger is operating, the battery voltage will still drop. When battery voltage is below 10.5/21/42V, the ISI-501 will shut down to prevent the battery from over discharging thereby increasing its lifetime. t6: If the charger continuously charges the battery, the battery voltage will slowly increase. When battery voltage reaches 13/26/52V, the system will re-power on after three minutes and start providing AC voltage output. t7: Same action as t3. The status of the inverter changes depending on the power provided by the PV module and its load consumption. t t 6

6.Protection 6.1 Input Protection (A)PV Module Reverse Polarity Protection: In the case where the user accidently reverses the polarity of the PV module, the ISI-501 internal fuse will blow to protect o ther circuitr y. Please contact your nearest distributer or send the inverter back to Mean Well for repair. (B)Battery Reverse Polarity Protection: In the case where the user accidently reverses the polarity of the battery connection, the ISI-501 internal fuse will blow to protect other circuitry. Please contact your nearest distributer or send the inverter back to Mean Well for repair. (C) Battery Low Shutdown Protection: When the battery voltage is lower than 10.5/21/42V, the ISI-501 will shut down to guarantee the lifetime of the battery. (D) Battery Overvoltage Protection: W hen the battery voltage is too high, the inverter will shut down an d the built- in alarm will sound. Please resolve the error and restart the inverter to return to normal operation. WARNING: Before installation or after use, make sure the power ON/OFF switch on the front panel is in the OFF position to safely wire or remove batteries. Under normal working conditions, please choose suitable batteries that are within the input DC voltage range of the inverter (refer to spec). If the input DC voltage is too low (e.g. using 12Vdc battery bank for 24Vdc models), the inverter cannot startup properly. If the input DC voltage is too high (e.g. using 48Vdc battery bank for 24Vdc models), the inverter will be damaged. 6.2 Output Protection If the ISI-501 detects any of the following errors while operating, the status red LED indicator will remain until the error is removed. (A)Over Temperature Protection(OTP) : When the internal temperature of the ISI-501 reaches a threshold, over temperature protection will activate, causing shutdown of the inverter. Wait at least 30 minutes before restarting to recover normal operation. (B) AC Output Short Circuit Protection: When the AC output of the ISI-501 is short circuited, it will go into protection mode. Restart to recover normal operation. (C) Over Load Protection: When the load is in the over load range of 500~550W (450~495W for 112/212 mode ls), the inverter can continue supplying power for a short duration of 1 minute. If the load is not removed, the sensing circuit will activate causing shut down. 7. Installation & Wiring (A)Wiring for batteries: Wire connection should be made as short as possible, 1.5m or less is strongly recommended. Also make sure suitable wires are chosen based on safety requirement and current rating. Cross sections that are too small will result in lower efficiency, less output po wer, and the wires m ay also become 7

overheated and cause danger. Please refer to table 7.1 or consult w ith our distributors or us if you have any questions. Table 7-1 Sug gestion for wire selection Cross section of wire lead(mm 2 ) AWG Suggested Model 1.5 2.5 4 6 14 12 10 8 PV module input wire 48V battery models 24V battery models 12V battery models (B)Suggested Battery Type and Capacity Battery Typ e Lead-acid Battery Cap acity Note : If the desired battery type is not Lead-Acid based, please contact the battery manufacturer for an advised value. (C)Installation Requirements: 12V mod els 24V models 48V models 12V / 120Ah ~ 24V / 60Ah ~ 48V / 30Ah ~ 12V / 400Ah 24V / 200Ah 48V / 100Ah The ISI-501 unit should be mounted on a flat surface or holding rack with suitable strength. In order to ensure the lifespan of the unit, please refrain the unit from operating in dusty or moist environments. This is a power unit with a built- in DC fan. Please make sure the ventilation openings are not blocked ; please do not drive the inverter continuously under heavy load in high ambient environment because it may prevent the inverter from functioning properly and the inverter's lifespan may be affec ted. It is highly recommended that there sho uld be n o objects impeding airflow within 15cm of the ventilation openings. >15cm Air Inverter >15cm Air Figure 7.1: Example of Installation 8

(D)Suggested Mounting The four holes on the sides of the case allow the users to mount and fix the ISI-501 on a flat surface. (It is highly recommended the ISI-501 is placed horizontally. Also, please pay attention to the ventilation.) (E)Example of System Setup Leads should be as short as possible AC O/P Greater than 15c m AC Load Solar panel Battery + - Greater than 15cm ISI-501 Inverter Solar DC I/P I/P FG - + + - Leads should be less than 1.5m Wall or system FG (F)Derating Based on the actual length of wiring, choose suitable cross-section of the leads 100 100 80 80 60 50 40 60 40 20 20-20 0 10 20 30 40 50 60 10.5VDC 11.5VDC 15VDC (HORIZONTAL) 21VDC 23VDC 30VDC 42VDC 46VDC 60VDC Ambient Temperature ( ) Ta Figure 7.2 Output Derating Curve 9 Battery In put Vo ltage (V) Figure 7.3 Input Derating Curve

(G) Notes on Output Loads: ISI-501 Series can power most equipments requiring an AC source of 500W continuously for a long time, but for certain type of load, this inverter may not work properly. (1 )Since indu ctive loads or motor bas ed e quipme nts need a large sta rt up current (6~10 times of its rated current), please make sure this startup current is less than the maximum current capability of the ISI-501. (2)When the loads are capaci tive or rectif ied equipment (s uch as s witc hing power supply), it is suggested to operate the equipment at no load or light load during pow er ON. Increas e th e loa d slowly on ly after the ISI-5 01 is powered up normally and steadily to ensure proper operation. 8. Troubleshooting The ISI-501 is a complex product which should be serviced by professional technicians. Improper usage or modification may damage the unit or result in shock hazards. If you are not able to clear the failure condition according to the following instructions, please contact us or your closest distributor for repair service. Failure Statue No AC Output Voltage Battery Discharging Period too short Possible Reasons Abnormal input Over temperature protection Overload protection Short circuit protection Battery aged or broken Battery capacity is too small Recommended Solutions Check the DC input source (PV/ battery) to make sure the voltage is within the specified range Make sure the ventilation is not blocked and the ambient temperature is not too high. Please derate the load or lower the ambient temperature Make sure the output load does not exceed the rated value or the peak startup current is not too high, typically found in inductive or capacitive loads Make sure the output is not overloaded or short circuited Replace the batteries Reconfirm battery specification and enlarge the battery capacity as suggested 9. Warranty Three years of warranty is provided under normal operating conditions. Please do not change components or modify the unit by yourself or attempt to repair the unit by yourself because Mean Well reserves the right to void the warranty. 10