FIRE DETECTION SYSTEMS



Similar documents
FIREDEX Conventional Fire Panels

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)

Premier M Plus & Infinity 8

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

VEGA Analogue Addressable Control Panels

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

SECTION DETECTION AND ALARM

CB200W Water Leak Detection Panel Application Guide

DTW Works Master Specification Version 2006

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Analogue addressable devices

conventional system operation

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

Fire detection equipment

500r+ Installation and User Guide

AlarmSense 2-wire detection and alarm system. Product Guide

AC-115 Compact Networked Single Door Controller. Installation and User Manual

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

ACTIVE 5 ENGINEERING MANUAL

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Global System Technology(UK) PLC The Intelligent Solution

C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

Fire & Security DETECTORS

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Conventional Fire Detection and Extinguishant Control System Specification

CB Zone Conventional Control Panel

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

Fire Alarm Control Panel. Family. Operating Manual

Quick Connect. quick - simple - efficient.

ZC-24DO CANopen I/O Module: 24 Digital Outputs

9452/9453 Installation and User Guide

Fire Detection Product Range

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

GST301. (Single Protection Zone) Operation Manual

MINERVA MX MX Virtual Multi-Sensor Detectors

Installation Manual for D1110 DigiCom2

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

JUNIOR V3. Fire Alarm Control Panel INSTALLATION & COMMISSIONING MANUAL GLOBAL REVISION 2.3 FIRE EQUIPMENT QUEUE REVIEW STATUS ZONES

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

Always on the Lookout Perfect Protection against Burglary

AIS750 Series Alarm Annunciator

M1000 Process Alarm Monitor

Manual for Fire Suppression & Methane Detection System

Repeaters and Mimics Data Sheet

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

HART HSSD High Sensitivity Smoke Detection

TMS TANK MANAGEMENT SYSTEM

Fire. The Fire Installers Mate. A guide to fire alarm systems design

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Catalog. Arc Guard System TM TVOC-2

HCR3.2/.. Chipcard reader HOTEL SOLUTION

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Installation manual. Version

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

SMART SENSOR COLLECTION

Technical Data. back-up time in minutes 100% load % load

Discovery 1-4 Loop Analogue Addressable Control Panel Application Guide

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

WD-AMX Water Detection Controllers

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Current Monitoring Kit QUICK START GUIDE

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

ALARMLINE ANALOGUE Linear Heat Detection System

Current Monitoring Kit

Triple Waveband Infra-Red Flame Detection

TrueAlarm Fire Alarm Systems

TS510 & TS500. Installation & User Guide. Compatible Equipment

Remote Monitoring and REC 501 Control Unit Product Guide

ACP10 10 Zone Intruder Alarm System

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

The supplier and installer of the system should be approved by the local civil defence authority.

EQUIPMENT SPECIFICATIONS

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

Microprocessor Home Security System

EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

INSTALLATION MANUAL PC2525. Version 1.1

LDG DTS-4/4R Desktop Coaxial Switch / Remote

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

HyperAccess Access Control System

VOICE RECORDING SYSTEM ISDN PRI / BRI

Advantium 2 Plus Alarm

Modular I/O System Analog and Digital Interface Modules

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

Syncro. Multi Loop Analogue Addressable Fire Control Panel. Product Manual. Man-1055 Issue 21 September 2010

Transcription:

FIRE DETECTION SYSTEMS Product catalogue

JUNO-SYS One loop analogue addressable control panel FUNCTIONAL Single loop panel - Non expandable Smaller Size: Junior 314x320x80 Supports connection to Mini-repeater via RS485 and/or fibre-optic interfaces 125 device addresses 96 VULCAN (addressable) ultra low current base sounders (32 address limit) 32 individually programmable sounder addresses Full SAM (Self Addressable Module) support 2 Fire output relays (change-over) and 1 Fault relay (change-over) 2 conventional alarm outputs (Individually programmable) All detector loops monitored for integrity 384 fully programmable zones 512 fully programmable sounder groups Event log (rolling, 2000 entries) Compatible with Apollo S90 /XP95T and DiscoveryT Protocols Compatible with all our own low cost ancillary modules Backlit LCD display with 4 rows of 40 characters Programming by integrated keypad Multiple language support (menu selectable) Optional fire and fault LED zone indication Integrated 8 zone LED fire zone indication Interactive DiscoveryT functions Pr.Id.:30103 2

RAIK-1 ANALOGUE ADDRESSABLE CONTROL PANEL RAIK Pr.Id.:30100 1-3 loops analogue addressable control panel RAIK-1 is an analogue addressable control panel with modular 1-3 loop configuration with 32 zones. Main unit is composed from RAIK A and B modules. Analogue loops are created with modules RAIK-M. See accessories bellow DETECTOR INPUTS ALARM OUTPUTS PROGRAM OUTPUTS SERVICE PORTS EVENT BUFFER ACCESSORIES PGD Pr.Id.:31103 RAIK-M Pr.Id.:31100 RAIK-U Pr.Id.:31101 RAIK-I Pr.Id.:30102 under UNI EN54-2 and UNI EN54-4, power supply 2A/24Vdc - max 378 analog detectors on 3 (6) loops - max 248 conventional local or remote lines (loop RS485) - 32 zone - alarm output with indication of short circuit - max 6 outputs el. programed - max 64 outputs programmed on 8 channel adapters, local or remote - alarm and trouble output N.O./ N.C. - connection with a PC trough RS-232/485 - serial clock/date output - local bus SPI for connection with I/O adapters Internal buffer for 800 evens, possible to download to a PC or print to RS232 Remote LCD indication keyboard Analogue addressable loop card for expansion of loop with 126 address or 2 loops of 63 address Input module with 8 inputs Output module with 8 relay outputs 3

JUNO NET Analogue addressable network control panel FUNCTIONAL Fully expandable system - from 1 to 96 loops 125 device addresses per loop 96 VULCAN (addressable) ultra low current base sounders per loop 32 individually programmable sounder addresses per loop 2 Fire output relays (change-over) Open collector outputs for Fire, Fault and Pre-alarm remote indicators 2 conventional alarm outputs on each Main Panel and Sub-panel Repeaters with optional Integrated Sub-panels All detector loops monitored for integrity 384 fully programmable zones 512 fully programmable sounder groups 1 TO 3 LOOPS Event log (rolling, 2000 entries) Compatible with Apollo S90/XP95 and Discovery Protocols Compatible with all our own low cost ancillary modules Backlit LCD display with 4 rows of 40 characters Programming by infra-red remote keypad, PC keyboard and Windows based Loader software Windows based PC graphics software for alarm management and reporting Multiple language support (menu selectable) BMS output (RS232) Evacuate/Class Change input Multi-panel network by RS485 or fibre optic links Optional internal 40 column thermal printer Optional fire and fault LED zone indication ELECTRICAL & MECHANICAL Primary supply voltage Secondary supply voltage Power supply rating Sounder output rating Auxiliary output rating Battery fuse rating Auxiliary contact rating Quiescent current w/out devices Box * Cable entries Dimensions (1-3 loops box) Dimensions (1-12 loops box) Dimensions (sub-panel box) Dimensions (mini-repeater box) Battery Capacity Weight 85-265V AC 50/60Hz 24V DC nominal 60W or 150W output 1 Amp 1 Amp fused 3 Amp 1A 50V AC/DC 130 ma 1.5mm aluminum or mild steel coated white Back through cut out/top by 6 removable plugs H: 370 W: 340 D: 127 (mm) H: 420 W: 550 D: 127 (mm) H: 370 W: 340 D: 127 (mm) TBA Up to 2 x 12V 12A/H 6.5 Kg 4

JUNO NET Analogue addressable network control panel 1, 3 LOOP Juno-NET 100 Pr.Id.:30109 Juno-NET300 Pr.Id.:30104 4-12 LOOPS Juno-NET 400 Pr.Id.:30105 5

JUNO NET Analogue addressable network control panel REP Pr.Id.:30114 REPEATER WITH OR WITHOUT INTEGRATED SUB-PANEL The JUNO-NET repeater has an identical appearance to the JUNO-NET main panel and has similar electrical characteristics. It allows full control and programming of the entire fire protection system as if you were at the main panel. A repeater with integrated sub-panel allows a distributed system topology ideal for multiple building networks where display and control is necessary in each building. Each integrated sub-panel has its own unique (programmable) address and can have either one or three detection loops. From the user perspective the only difference between a repeater and the main panel is that a repeater cannot support a printer. SUB-PANEL Pr.Id.:30108 Whenever a fire alarm system grows beyond 3 loops in terms of either detection points or topology, it is possible to add sub-panels in increments of 3 loops and supplied in fully closed cabinets, provided with independent primary and secondary power supplies. In each cabinet it is possible to install 1, 2 or 3 sub-panel boards with each board containing 3 loops, hence the 1-9 loops capability. The power supply is 5.4A PSU/Charger. Only one RS-422/485 or Fibre-optic interface is needed in each cabinet to provide the communication path to the rest of the system. These cabinets can be installed closer to the fire monitoring devices, enabling significant savings in expensive fire-proof cabling REP-Mini Pr.Id.:30113 This sleek, unobtrusive repeater panel can be used to control any distributed, or self-contained JUNO-NET based fire alarm system. Because of its reduced dimensions it is especially recommended for front desk monitoring of large systems where it would be impractical to place a full size control panel in a cluttered reception booth. Up to 10 repeaters can be connected to a main JUNO-NET fire alarm panel, all of which offer full control over the system. Connection to the JUNO- NET is via its data-loop communication bus and can be through an RS- 422/485 or Fibre-optic interface. Compatible with Juno-SYS. 6

JUNO NET Analogue addressable network control panel ACCESSORIES J-NET-LOOPCON Pr.Id.:30118 DIMENSIONS: FACE PLATE 76 x 76 x 2 (mm) DIMENSIONS: INDICATOR: 68 x 33 x 25 (mm) LOOP CONNECTOR This interface board provides a separate area for connecting the addressable loops wiring. It also has the entry level filtering to reduce overall noise susceptibility of the JUNO-NET panel ( needed if REP + loop card are used) Loop card-1 Pr.Id.:30106 DIMENSIONS: FACE PLATE 76 x 76 x 2 (mm) DIMENSIONS: INDICATOR: 68 x 33 x 25 (mm) & Loop card-3 Pr.Id.:30107 LOOPCARD - SINGLE AND THREE LOOPS These are the work-horses of our range of panels. Since their creation in 1992 they have been improved in many respects, reaching today an unparalleled performance in their function of interfacing the real world of the loop wiring and devices, with the sensitive electronics of an advanced fire alarm control panel. SUB-PANEL DIMENSIONS: FACE PLATE 76 x 76 x 2 (mm) DIMENSIONS: INDICATOR: 68 x 33 x 25 (mm) The sub-panel board is in essence a building block of a JUNO-NET control panel, either in a distributed or self contained topology. Capable of managing up to 3 loops of analogue addressable devices, it will operate on its own even in the event of lack of communication with the JUNO-NET main panel, detecting fire and fault situations and activating its own loop sounders, I/O units etc. This unit is also the processor board for the JUNO-NET Mini-Repeater as well as our low-costing single loop panel named JUNiOr. JUNiOr will be out towards end of 2003. Printer WEIGHT: DIMENSIONS: Pr.Id.:30108 Pr.Id.:30110 208 grams (including paper roll) H: 65 W: 145 D: 45 (mm) This 40 column internally mounted thermal printer provides a log of all the relevant events occurring in the JUNO-NET system. All events are date and time stamped and are backed up by the 2000 events deep rolling log kept in the panel processing unit. SUB-PANEL BOARD INTERNAL PRINTER OPI TON NOTE: In order for the printer to work properly it is necessary that the J-NET-QUART chip (pictured) be installed on the JUNO-NET main board. 7

JUNO NET Analogue addressable network control panel ACCESSORIES If the system is distributed, the communication between the main panel and the external sub-panels or repeaters is supported by either an RS422/485 fully redundant loop or alternatively fibre-optic cable. In both cases the data loop is protected from interruptions or via short-circuits by creating a bi-directional communication flow. If the main panel is unable to communicate with a sub-panel or repeater, it will try reaching it through the opposite direction and signal a communication fault. If RS422/485 is to be used, the cable needed will be a 4 core shielded and fire proof data cable, running a loop from the main panel through all the repeaters and sub-panels in the system and returning to the main panel. It is desirable to use fibre-optic cable for the data loop when longer distances between nodes demand it (above 1200 m) or in premises with high levels of electrical disturbances. The cable used for this type of connection should be dual core sheathed fire proof with 62.5/125 fibre terminated in ST connectors. This type of data loop is also fully redundant and permits distances between nodes of up to 4.5 Km. J-NET-INT-485 WEIGHT: DIMENSIONS: Pr.Id.:30116 34 grams H: 25 W: 115 D: 10 (mm) This board is a complement to the J-NET-INT-485, and provides the screw connection terminals that do not fit in the former PCB is reduced dimensions. It also provides spark-gap discharge protectors for each in or outbound connection, improving the degree of protection against atmospheric discharge interference. EXTERNAL RS485 INTERFACE OPTION J-NET-INT-FO Pr.Id.:30117 FIBRE-OPTIC COMMUNICATION INTERFACE OPTION WEIGHT: DIMENSIONS: 22 grams H: 39 W: 77 D: 9 (mm) This interface unit converts the TTL level networking signals to dual channel optical fibre compatible levels, to allow long distance interconnection between a JUNO-NET main panel and either one or more sub-panels and/or repeaters with or without integrated sub-panels. The optical inputs and outputs are inherently optically isolated from the panel or subpanel to which it is connected. This optical isolation avoids disturbance created by ground loops and ensures complete protection from possible shock hazards and wiring mistakes. The TTL connections are via a 5 pin Molex connector which carries the supply and TTL Quart COMS Pr.Id.:30112 COMMUNICATION INTERFACE OPTION WEIGHT: DIMENSIONS: 28 grams H: 41 W: 65 D: 20 (mm) When the need arises to interface the JUNO-NET with the outside world, you will be required to use one of the following units. If your requirements are Uploading/Downloading data from your PC to the main panel, connecting your system to a graphics software like the Odyssey or the installation of an external printer, then you will need the J-NET-INT-COMS board correctly configured for each of the above mentioned purposes. Identification of the boards is by way of labels since the corresponding configuration of each board is done in factory. 8

or many fire alarm systems, all that is required is a simple stand-alone fire alarm panel, monitored by a receptionist or Fsecurity guard. A printer can be connected to the computer to record all alarm, fault and programming activity on the system. Pr.Id.:30111 Panel list screen with 5 panels connected Initial alarm screen showing general area Juno 1-3 loop panel display Highest zoom showing detector in alarm Juno NET panel display Front page showing Telephone Nº utility 9

ADDRESSABLE DETECTORS The X series is a precise, and high reliable EN-54 approved Analog Addressable smoke alarms. It comes with a series of 3 different types: smoke only (X-O), heat only (X-T), and smoke + heat combination (X-O/T) detection. ADDRESSABLE X SERIES Dual LEDs for 360 visibility Advanced detection and discrimination algorithms Easy installation and maintenance Sleek low-profile housing design Durable sensor head, no need for replacement SMD circuit board design-satisfactory quality and reliability guaranteed Five-year limited warranty Sensor base option: standard and Shottky Diode Pr.Id.:32522 Pr.Id.:32523 Pr.Id.:32524 Model X-O X-T X-O/T 2/4 Wire 2 2 2 Thermal / Optical Optical Thermal Thermal/Optical Voltage DC 15-30V 15-30V 15-30V Standby Current (Max) 370 A 370 A 370 A Alarm Current (Max) 370 A 370 A 370 A Surge Current (Max) 370 A 370 A 370 A Start-Up Time (Max) 30sec 30sec 30sec Permissible Current (Max) 80mA 80mA 80mA Frequency 3-5sec 3-5sec 3-5sec Base Model X-B X-B X-B 10

MANUAL CALL POINTS X-MCPA-KAC Pr.Id.:32114 ELECTRICAL ADDRESSABLE LOOP CURRENT LOOP CURRENT (NORMAL) 0,35 ma LOOP CURRENT (FIRE) 3,1 ma OPERATING TEMPERATURE: 0-85 C HUMIDITY: 30-95% NON-CONDENSING ADDRESSABLE MANUAL CALL-POINT UNIT MECHANICAL WEIGHT 150 grams DIMENSIONS H: 52 W: 87 D: 87 (mm) 2 WIRE CAPACITY up to 2,5mm FIXINGS surface mount: 4 holes The X-MCPA-KAC manual call point uses a new communication mechanism that gives a typical alarm response time of approximately one second and yet does not use Apollo's patented interrupt bit solution. This new communication system is fully compatible with all our addressable modules, SAM's, S90, XP95 and Discovery detectors. Like Apollo's interrupt based system, the more call points on a loop, the longer the time from activation to alarm. X-MCPA-FLAP ELECTRICAL ADDRESSABLE LOOP CURRENT LOOP CURRENT (NORMAL) LOOP CURRENT (FIRE) OPERATING TEMPERATURE: HUMIDITY: S-MCPA-2470 Pr.Id.:32526 ADDRESSABLE MANUAL CALL-POINT UNIT (LOW-PROFILE) 0,35 ma 3,1 ma 0-85 C 30-95% NON-CONDENSING Both the MCPA-KAC and the MCPA-FLAP are addressable manual callpoints, compatible with a version of the meter bus protocol used by several panel manufacturers, used for signaling an emergency or fire situation to an addressable fire detection control panel. The main features of these units are their low quiescent power consumption and low cost. An 8 way DIL switch is used for setting the address of the unit within the communication loop. Addresses 0 to 125 can be programmed in binary code, where a switch in the OFF position represents a 0. This unit returns an analog value of 16 when the glass is intact and a value of 64 when the glass panel has been pressed. The unit is provided with a bi-color LED which signals with a green light flash when the unit is being interrogated by the control panel. When in ALARM, the LED is illuminated in red by command of the control panel. Pr.Id.:32116 MECHANICAL WEIGHT 80 grams DIMENSIONS H: 28 W: 120 D: 80 (mm) 2 WIRE CAPACITY up to 2,5mm FIXINGS surface mount: 2 holes CONVENTIONAL MANUAL CALL-POINT UNIT (LOW-PROFILE) ELECTRICAL MECHANICAL QUIESCENT DC CURRENT 40 µ A WEIGHT 80 grams FIRE CURRENT 20 ma DIMENSIONS H: 52 W: 87 D: 87 (mm) 2 OPERATING TEMPERATURE 0-85 C WIRE CAPACITY up to 2,5mm HUMIDITY 30-95% NON-CONDENSING FIXINGS surface mount: 2 holes The S-MCPC-2470 is a conventional manual call-point compatible with all conventional fire alarm control panels. The main feature of this unit is the use of a bi-color LED to signal the operational status of the call-point. The included LED blinks regularly with the green color while connected to a detection zone and lights with a permanent red light when activated, (alarm condition). This, allied with its very competitive price and aesthetic appearance, make the S-MCPC-2470 a very attractive product. 11

ADDRESSABLE SOUNDERS X-VIPER - A X-VIPER - A - SE X-VIPER BEACON SOUNDERS FEATURING LOW POWER CONSUMPTION & HIGH SOUND OUTPUT X-VIPER - A STANDARD SUPPLY VOLTAGE: 17-40 V DC CURRENT CONSUMPTION QUIESCENT: CURRENT CONSUMPTION ALARM: HIGH FREQUENCY SOUND: ADDRESS RANGE: Pr.Id.:32532 1 ma 6 ma 11 ma 94-125 (32/Loop) SHADOW 17-40 V DC 1 ma 6 ma 11 ma SHADOW (64/Loop) VIPER ADDRESSABLE SOUNDER WEIGHT: DIMENSIONS: SOUND OUTPUT: TONES: PROTECTION RATING: IP65 153 grams DIAMETER: 100 - HEIGHT: 85 (mm) 85dB @ 1 METRE (92dB High Pitch) 4 TONES SELECTED BY DIL SWITCH This addressable sounder is a surface mountable unit available in red and white colors with very low power consumption as its main characteristic. It has a sound output of up to 92dBA with less than 5mA power consumption @ 24V. It is possible to place up to 96 sounders or 64 sounder/beacons in a single loop, 32 of which can be given a response address, the remaining being shadow sounders. ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF PROGRAMMING DATA FOR ADDRESSABLE BASE SOUNDER 1 2 3 4 5 6 7 8 SWITCHES 1-5: REGULAR ADDRESSES FROM 094 TO 125 IN BINARY SWITCH 6: OFF: IAS LOOP SOUNDER ON: APOLLO SOUNDER CIRCUIT CONTROLLER SWITCH 7 & 8: OFF: SWEEP SOUND (800-1000 Hz) SWITCH 7 ON & 8 OFF: ALTERNATE SOUND (2800-3500 Hz) SWITCH 7 OFF & 8 ON: ALTERNATE SOUND (800-1000 Hz) SWITCH 7 & 8: ON: CONTINUOUS (800 Hz) X-VIPER SE X-VIPER - BEACON Pr.Id.:32529 STANDARD SUPPLY VOLTAGE: 17-40 V DC CURRENT CONSUMPTION QUIESCENT: 0.8 ma 3.5 ma CURRENT CONSUMPTION ALARM: ADDRESS RANGE: TONES: PROTECTION RATING: + + + + CONNECTION DIAGRAM WEIGHT: DIMENSIONS: CONTINUOUS TONE: RAMP TONE: BI-TONAL BI-TONAL 1 2 3 4 5 6 7 8 Also exists in SHADOW version (see BASE SOUNDER) VIPER ADDRESSABLE SOUNDER - SPECIAL EDITION SHADOW 17-40 V DC 0.8 ma 3.5 ma 94-125 (32/Loop) + SHADOW (64/Loop) 4 TONES SELECTED BY DIL SWITCH IP65 WEIGHT: 125 grams DIMENSIONS: DIAMETER: 100 - HEIGHT: 85 (mm) SOUND OUTPUT- CONTINUOUS85 db @ 1 METRE SOUND OUTPUT- SWEEP: 85 db @ 1 METRE SOUND OUTPUT- ALTERNATING: 85 db @ 1 METRE SOUND OUTPUT- HIGH PITCH: 92 db @ 1 METRE This addressable sounder is a surface mountable unit available in red and white colors with very low power consumption as its main characteristic. It has a sound output of up to 92dBA with less than 5mA power consumption @ 24V. It is possible to place up to 96 sounders or 64 sounder/beacons in a single loop, 32 of which can be given a response address, the remaining being shadow sounders. SUPPLY VOLTAGE: 17-40 V DC CURRENT CONSUMPTION QUIESCENT: CURRENT CONSUMPTION ALARM: ADDRESS RANGE: TONES: PROTECTION RATING: Pr.Id.:32531 1 ma 4.5 ma 94-125 (32/Loop) 4 TONES SELECTED BY JUMPERS IP44 VIPER ADDRESSABLE SOUNDER & BEACON 175 grams DIAMETER: 100 - HEIGHT: 70 (mm) 1000Hz 800-1200Hz 1000-1300Hz 2000-2600Hz This addressable sounder/beacon, is a surface mountable unit available in red color with very low power consumption as its main characteristic. It has a sound output of up to 92dBA with less than 5mA power consumption @ 24V. This includes a high power LED based beacon which uses 8 super-high efficiency RED LED's. It is possible to place up to 96 sounders or 64 sounder/beacons in a single loop, 32 of which can be given a response address, the remaining being shadow sounders. The beacon operation can be chosen between two modes: Mode A: The beacon operates simultaneously with the sounder and stops with the silencing. Mode B: The beacon operates simultaneously with the sounder but does not stop flashing until the loop is 12

ADDRESSABLE SOUNDERS X-VULCAN - A PROGRAMMING DATA FOR ADDRESSABLE BASE SOUNDER 1 2 3 4 5 6 7 8 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF SWITCHES 1-5: REGULAR ADDRESSES FROM 094 TO 125 IN BINARY SWITCH 6: OFF: IAS LOOP SOUNDER ON: APOLLO SOUNDER CIRCUIT CONTROLLER SWITCH 7 & 8: OFF: SWEEP SOUND (800-1000 Hz) SWITCH 7 ON & 8 OFF: ALTERNATE SOUND (2800-3500 Hz) SWITCH 7 OFF & 8 ON: ALTERNATE SOUND (800-1000 Hz) SWITCH 7 & 8: ON: CONTINUOUS (800 Hz) 1 2 3 4 5 6 7 8 + + + + X-VULCAN STANDARD SHADOW SUPPLY VOLTAGE: Pr.Id.:32533 CURRENT CONSUMPTION QUIESCENT: CURRENT CONSUMPTION ALARM: ADDRESS RANGE: TONES: PROTECTION RATING: 17-40 V DC 0.8 ma 3.5 ma 94-125 (32/Loop) VULCAN ADDRESSABLE BASE SOUNDER Accepts APOLLO XP95 Detector Base. + 17-40 V DC 0.8 ma 3.5 ma SHADOW (64/Loop) 4 TONES SELECTED BY JUMPERS IP44 WEIGHT: 75 grams DIMENSIONS: DIAM.: 112 - HEIGHT: 37 (mm) SOUND OUTPUT- CONTINUOUS 85 db @ 1 METRE SOUND OUTPUT- SWEEP: 85 db @ 1 METRE SOUND OUTPUT- ALTERNATING: SOUND OUTPUT- HIGH PITCH: 85 db @ 1 METRE 92 db @ 1 METRE This sounder is an ultra low power base sounder, intended to be used both as a stand-alone low profile sounder, or as a combined detector plus sounder assembly. When configured as a SHADOW sounder, by cutting the appropriate link, these sounders become invisible to the fire alarm control panel. This characteristic means that although the panel can control the activation of the sounders - in up to 32 groups per loop - each of these groups can have more than one and up to 64 sounders because the devices are not reporting back to the panel. This also means that device addresses 94 to 125, hereto reserved for addressable sounders, can be concurrently used by other device types, i.e. detectors and call points, meaning that at this stage the total numbers of sounders per loop is raised to 64 together with up to 125 other devices, detectors etc... This implies that the sounders are NOT monitored individually, but solely as part of the detection loop. 13

SAM FEATURES Pr.Id.:32530 Up to 125 SAM's can be connected to a loop SAM addresses are set by the test\commissioning sequence SAM's can be fitted to the same loop as any of our addressable modules SAM's can be fitted to the same loop as S90, XP95 and Discovery detectors SAM addresses can be erased and re-programmed SOFT ADDRESSABLE MODULE Fully encased for protection in high impact plastic Small dimensions: 41.5 x 24.5 x 10.5 (mm) Connections compatible with fork terminals or wire up to 1.5 mm2 Two versions available: SAM-S for Smoke detectors SAM-H for Heat detectors Following strategy of providing competitive products for our esteemed customers, we are pleased to announce the launch of SAM. This tiny, very low cost, module provides any conventional detector with an address without the inconvenience of using a manual addressing unit or DIP switch. The SAM is simply attached to the conventional detector and the detector address is automatically assigned to each SAM by the JUNO-NET or JUNiOr control panel during commissioning and testing. A SAM based system tolerates loop branches and can monitor loop interruptions and head removal. SAM is ideal for low budget retrofits where fire point identification is needed but the cost of fitting a fully analogue system is too high. SAM is also an option in low budget installations that would normally be implemented with 4 to 8 zone conventional systems. It gives you the cable savings possible (see below) with an addressable system, together with the loop sounder capability but without the extra costs of analogue addressable heads. Compatible with any make of conventional detector, the SAM is fully encapsulated in a plastic case, unobtrusive and easy to connect to the detector base. CONVENTIONAL PANEL INSTALATION CABLE REQUIRED: METERS 200 SAME INSTALATION USING JUNO-NET PANEL & SAM SYSTEM CABLE REQUIRED: 78 METERS 3 2 1 3 2 1 4 4 4 5 6 7 8 5 6 7 8 A SAM system can prove economical as an alternative to conventional systems as small as 4 detection zones. Up to 125 detection devices can be fitted to a single loop of fireproof cable. This, together with the use of addressable loop powered sounders, keeps wiring costs to a minimum and gives the customer all the flexibility and programmability of an addressable system at an extremely competitive price. 14

X-IN X-I/O X-IN ELECTRICAL ADDRESSABLE LOOP CURRENT LOOP CURRENT (NORMAL) LOOP CURRENT (O.C. FAULT) LOOP CURRENT (S.C. FAULT) LOOP CURRENT (FIRE) X-I/O Pr.Id.:32600 ELECTRICAL ADDRESSABLE LOOP SUPPLY LOOP CURRENT (NORMAL) LOOP CURRENT (O.C. FAULT) LOOP CURRENT (S.C. FAULT) LOOP CURRENT (FIRE) LOOP CURRENT (RELAY ACTIVE) RELAY CONTACT RATING ma 0,7 0,7 0,7 3,1 ma 0,7 0,7 0,7 3,1 18,5 50V 1A Resistive ADDRESSABLE SINGLE INPUT UNIT MECHANICAL WEIGHT 30 grams DIMENSIONS H: 20 W: 45 D: 53 (mm) 2 WIRE CAPACITY up to 2,5mm FIXINGS surface mount: 4 holes The INPUT UNIT is an addressable module, compatible with a version of the meter bus protocol used by several panel manufacturers, which allows the connection of a normally open contact to an addressable fire detection system. This is normally used to signal an alarm or fault situation in machinery or other alarm situations like flooding, etc..., by means of Fire detection system. The module is supplied from the detection loop and monitors the connection to the monitored switch. This is done by placing a 22 K ohm E.O.L. at the connections end and connecting a 4K7 resistor in series with the alarm switch. The input status is visualized locally by a red LED, where the red light signals an alarm condition. The INPUT unit is available as an electronic module with four fixing holes, or as a boxed unit for individual module installations. The module detects and reacts to four bands of resistance between its input terminals, which are as follows: OPEN TO 50K - FAULT REPORTED 50K TO 8K2 - NORMAL REPORTED 8K2 TO 2K2 - FIRE REPORTED 2K2 TO 0R0 - FAULT REPORTED Pr.Id.:32510 ADDRESSABLE SINGLE INPUT/OUTPUT UNIT MECHANICAL WEIGHT 30 grams DIMENSIONS H: 15 W: 52 D: 57 (mm) 2 WIRE CAPACITY up to 2,5mm FIXINGS surface mount: 4 holes The I/O-ISO is an addressable module, compatible with a version of the meter bus protocol used by several panel manufacturers, which allows the connection of a normally open contact to an addressable fire detection system, providing at the same time an output relay contact to control ancillary equipment. This is normally used to signal alarm or fault situations in machinery or other alarm situations like flooding etc..., and controlling ancillary equipment, by means of the Fire detection system. The module is supplied from the detection loop and monitors the monitored switch. This is done by placing a 22K ohms E.O.L. resistors at the connections ends and wiring a 4K7 resistor in series with the alarm switch. The input status is visualized locally by a red LED, where the red light signals an alarm condition. The relay operation is signaled by a yellow LED which lights when the relay is actuated. The power for actuating the relay can be external or drawn from the detection loop. The choice is made by shorting two pads on the solder side of the PCB for loop power, or leaving those open if an external supply is available. By default, the unit is prepared for loop power. The external supply is optically isolated from the detection loop. The I/O-ISO is available as an electronic module with four fixing holes, or as a boxed unit for individual module installations. The module detects and reacts to four bands of resistance between its input terminals, which are as follows: OPEN TO 50K - FAULT REPORTED 50K TO 8K2 - NORMAL REPORTED 8K2 TO 2K2 - FIRE REPORTED 2K2 TO 0R0 - FAULT REPORTED 15

X-I/O3 X-I/O8 X-I/03 Pr.Id.:32527 ELECTRICAL ADDRESSABLE LOOP SUPPLY LOOP CURRENT (NORMAL) LOOP CURRENT (O.C. FAULT) LOOP CURRENT (S.C. FAULT) LOOP CURRENT (FIRE) RELAY CONTACT RATING ma 0,7 3,1 3,1 3,1 50V 1A Resistive ADDRESSABLE TRIPLE INPUT / OUTPUT UNIT MECHANICAL WEIGHT 80 grams DIMENSIONS H: 20 W: 72 D: 88 (mm) 2 WIRE CAPACITY up to 2,5mm FIXINGS surface mount: 4 holes The 3 I/O-ISO is an addressable module, compatible with a version of the Meter bus protocol used by several panel manufacturers, which allows the connection of three normally open contacts to an addressable fire detection system, providing at the same time three output relay contacts to control ancillary equipment. This is normally used to signal alarm or fault situations in machinery or other alarm situations like flooding etc..., and controlling ancillary equipment, by means of the Fire detection system. The module is supplied from the detection loop and monitors the connection to the monitored switches. This is done by placing a 22K ohms E.O.L. resistors at the connections ends and wiring a 4K7 resistor in series with the alarm switches. The input status is visualized locally by three red LED's which signal a fire condition at the inputs, and a yellow common fault LED. The relay operation is signaled by three red LEDs which light when the respective relays are actuated. The power for actuating the relays is derived from an external P.S.U. The external supply is optically isolated from the detection loop. The 3 I/O-ISO is available as an electronic module with four fixing holes. The module detects and reacts to four bands of resistance between its input terminals, which are as follows: OPEN TO 50K - FAULT REPORTED 50K TO 8K2 - NORMAL REPORTED 8K2 TO 2K2 - FIRE REPORTED 2K2 TO 0R0 - FAULT REPORTED X-I/O8 Pr.Id.:32601 ELECTRICAL ADDRESSABLE LOOP CURRENT LOOP CURRENT (NORMAL): 0.7 ma RELAY CONTACT RATING: 50V 1A RESISTIVE ADDRESSABLE 8 INPUT / 2 OUTPUT UNIT MECHANICAL WEIGHT 60 grams DIMENSIONS H: 20 W: 88 D: 74 (mm) 2 WIRE CAPACITY up to 2,5mm FIXINGS surface mount: 4 holes The 8 I/O module is an addressable module, compatible with a version of the meter bus protocol used by several panel manufacturers, which allows the connection of eight normally open contacts to an addressable fire detection system, providing at the same time two output relay contacts to control a conventional fire alarm panel. This module will normally be used to interface existing conventional fire alarm systems to an analogue addressable fire control panel. The module is supplied from the detection loop but requires a nominal 24V DC supply for relay energizing. This auxiliary supply can be derived from the conventional fire alarm panel. The alarm silencing and reset functions of the conventional fire alarm panel can be executed by silencing and resetting the analogue addressable fire control panel. The 8 inputs are digital normally open inputs that can be connected to the zone repeater outputs of the conventional fire alarm panel. The silence and reset relay operation is signaled by two green LEDs. The external supply is optically isolated from the detection loop. 16

X- X-LSCM X-LSCISO Pr.Id.:32602 TECHNICAL WORKING VOLTAGE: QUIESCENT CURRENT CONSUMPTION: ALARM CURRENT CONSUMPTION: OPERATING TEMPERATURE: HUMIDITY: LOOP SOUNDER CONTROL MODULE WITH 1 AMP MONITORED OUTPUT 17-40 VOLTS DC 750uA MAX. 1.5mA MAX. 0-85 C 30-95% NON-CONDENSING EXTERNAL SUPPLY WORKING VOLTAGE: QUIESCENT CURRENT CONSUMPTION: ALARM CURRENT CONSUMPTION: ISOLATION: DIMENSIONS: WEIGHT: 12-30 Volts DC 1.9mA max.. 1A max. 500 Volts DC/max. H: 19 W: 48 D: 58 (mm) 30 grams The LSC-ISO is an externally powered sounder control module, designed mechanically to be mounted inside a standard module box The main feature of this module is its capability to drive and monitor a bell output with a maximum output of 1A. The wiring to the sounders is monitored for short and open circuit in quiescent mode requiring a single 10K ohm resistor to be placed at the end of the monitored line. A six way DIL switch of which only the first five sections are used allows programming of addresses 94 to 125. The output of the module is by a two way terminal block where the line of conventional sounders is connected. The output can either be pulsed or continuous. The protocol used by the LSC-ISO is only compatible with GFE's range of panels. A maximum number of 32 modules can be connected to each addressable loop. The current derived to the sounder output is limited to 1A which protects the output from overloading if the output is accidentally shorted. When the line monitored is correctly terminated by a 10K ohm resistor an analogue value of 16 is returned upon interrogation of the device. If the sounder line is either interrupted or short circuited at any point, a fault value of 4 is returned. When in alarm, the analogue value reported by the device is always 17. This signals to the control panel that the sounder controller has responded to its activation command. X-LSCM Pr.Id.:32603 TECHNICAL WORKING VOLTAGE: QUIESCENT CURRENT CONSUMPTION: ALARM CURRENT CONSUMPTION: OPERATING TEMPERATURE: 17-40 VOLTS DC 330uA MAX. 40mA MAX. (load dependent) 0-85 C LOOP SOUNDER CONTROL MODULE HUMIDITY: DIMENSIONS: WEIGHT: 30-95% NON-CONDENSING H: 16 W: 37 D: 31 (mm) 15 grams The LSCM1 is a loop powered sounder control module, designed mechanically to be mounted inside any conventional sounder or beacon with up to 40mA consumption. The main features of this module are its low power consumption in quiescent mode and its electronic and mechanical simplicity which make it a reliable and economical piece of equipment. A six way DIL switch allows assigning of the address pertaining to each sounder, in the range from 94 to 125. The first five switches define this address, where an "all off" setting corresponds to address 94. Switch #6 defines the operation mode of the module; If this switch is OFF, the module responds as an GFE sounder controller, if it is in the ON position, its operation will be equivalent to an Apollo Sounder Circuit Controller. The output of the module is by two leads that are simply connected to the terminals of the sounder or beacon which are relevant. The output can either be pulsed or continuous. The protocol used by the LSCM1 is only compatible with GFE's range of panels. When exposed to a XP95 interrogation format the module just continues its power management function without disturbing the communication of other XP95 devices in the loop. The current derived to the sounder output is limited to 40mA which protects the loop from overloading if the output is accidentally shorted. When a sounder is connected to the module's output an analogue value of 16 is returned upon interrogation of the device. If no connection is made to the output, a fault value of 4 is returned. When in alarm, the analogue value reported by the device is always 17. This signals to the control panel that the sounder controller has responded to its activation command. 17

X-ZMU X-ZMU4 X-ZMU ELECTRICAL ADDRESSABLE LOOP SIDE ma LOOP CURRENT (NORMAL) 2,9 LOOP CURRENT (O.C. FAULT) 1,5 LOOP CURRENT (S.C.FAULT) 1,5 LOOP CURRENT (FIRE) 3,1 X-ZMU4 Pr.Id.:32511 EXTERNAL SUPPLY SIDE SUPPLY CURRENT (NORMAL) SUPPLY CURRENT (O.C. FAULT) SUPPLY CURRENT (S.C.FAULT) SUPPLY CURRENT (FIRE) ZONE MONITORING UNIT The ZMU is an addressable module, compatible with a version of the meter bus protocol used by several panel manufacturers, and which allows the connection of a number of conventional smoke or heat detectors and manual call-points, to an addressable fire detection system. This means that from a detection and alarm processing point of view, that group of detection devices is given an address and considered as an unique alarm source. Using this module is a natural option in the protection of large areas, like underground parking lots, where the expense of using addressable detectors is not justifiable, even though the configuration of the rest of the building requires those. This module can draw its power from the communication loop which dispenses with the need for an additional power supply connection, or be supplied from an external power supply unit. This is defined by removing the two jumpers installed as a default. The unit controls a zone of conventional detectors with a 4K7 ohm passive E.O.L. Because the current drawn from the loop can be significant, especially in Fire and S.C. Fault conditions, the number of modules that can be supplied is limited. The current status is visualized locally by a dual color LED, where the green light means a normal current condition, a red light signals a fire condition and no light indicates a fault. The unit monitors the external power supply, reporting a fault if the auxiliary power is not present. The ZMU is available as an electronic module with four fixing holes, or as a boxed unit for individual module installations. The module detects and reacts to four bands of zone current which are interpreted and signaled to the control panel and which are as follows: 0 TO NORMAL - FAULT REPORTED NORMAL TO ALARM - NORMAL REPORTED ALARM TO SHORT CCT - FIRE REPORTED SHORT CCT - FAULT REPORTED Pr.Id.:32528 ELECTRICAL ADDRESSABLE LOOP SIDE ma LOOP CURRENT (NORMAL) 1,5 LOOP CURRENT (O.C. FAULT) 1,5 LOOP CURRENT (S.C.FAULT) 1,5 LOOP CURRENT (FIRE) 1,5 0 TO NORMAL - FAULT REPORTED NORMAL TO ALARM - NORMAL REPORTED ALARM TO SHORT CCT - FIRE REPORTED SHORT CCT - FAULT REPORTED ma 7 1,5 60 30 EXTERNAL SUPPLY SIDE ma SUPPLY CURRENT (NORMAL) 7 / CCT SUPPLY CURRENT (O.C. FAULT) 1,5 / CCT SUPPLY CURRENT (S.C.FAULT) 60 / CCT SUPPLY CURRENT (FIRE) 30 / CCT MECHANICAL WEIGHT 30 grams DIMENSIONS H: 20 W: 60 D: 60 (mm) 2 WIRE CAPACITYUP TO 2,5 mm ADDRESSABLE 4 ZONE MONITOR UNIT EXTERNALLY POWERED MECHANICAL WEIGHT 130 grams DIMENSIONS H: 20 W: 75 D: 148 (mm) 2 WIRE CAPACITYUP TO 2,5 mm The QUAD-ZMU is an addressable module, compatible with a version of the meter bus protocol used by several panel manufacturers, and which allows the connection of four zones with a number of conventional smoke or heat detectors and manual call-points, to an addressable fire detection system, using four consecutive addresses. This means that from a detection and alarm processing point of view, each group of detection devices is given an address and considered as an unique alarm source. Using this module is a natural option in the protection of large areas, like underground parking lots, where the expense of using addressable detectors is not justifiable, even though the configuration of the rest of the building requires those. This module requires the connection of 24V DC supply which is permanently monitored and allows the connection of four standard zones of detectors with 4K7 ohm passive E.O.L. The detection zones and their supply voltage are optically isolated from the addressable detection loop, which allows the use of a local independent power supply. If that supply fails, a FAULT condition is reported to the control panel. The current status of each zone is visualized locally by two LED s, where the yellow light means a fault condition and a red light signals a fire condition and no light indicates a normal situation. A green LED indicates that there is power on the zone connections. The individual zones of this module detect and react to four bands of zone current which are interpreted and signaled to the control panel and are as follows: 18

ACCESSORIES X-IND WORKING VOLTAGE RANGE: CURRENT CONSUMPTION: Pr.Id.:32521 3-15 V DC 300 µa - 15 ma FLASHING REMOTE INDICATOR DIMENSIONS: FACE PLATE DIMENSIONS: INDICATOR: 76 x 76 x 2 (mm) 68 x 33 x 25 (mm) This remote indicator can be used with any fire alarm detector, be it of the conventional or addressable/analogue types, to indicate remotely the activation of the relevant detection device. It s main characteristics are the high visibility due to the alternate blinking of two high efficiency LED s ( A Version), and the wide operating voltage range 3 to 15 DC Volts, with a minimum of 300 µ A current consumption. The two connections of this device are non-polarized, avoiding wasted time at the installation phase. The unit comes complete with a face plate compatible with standard flush mounting boxes. JUNCTION BOX Pr.Id.:32604 ABS MULTI PURPOSE JUNCTION BOX Our ABS molded multi purpose junction box is provided in RED or WHITE color with matching snap-on cover and has four mounting holes compatible with our single channel addressable modules. It is intended for surface use but can also be embedded. Weight with cover: 74 grams. 485 INT SUPPLY VOLTAGE: OPERATING CURRENT: MAX BAUD RATE: Pr.Id.:32605 20-30V. 25mA max. 9600 baud RS232/RS485 CONVERTER WEIGHT: DIMENSIONS: 44 grams H: 51 W: 101 D: 16 (mm) This optically isolated converter can be used to connect RS232 signaling equipment over distances up to 1200 m. It is mainly used in conjunction with the JUNO panels and repeaters. 19