Environmental Monitoring



Similar documents
Environmental Monitoring of Clean Rooms

ENVIRONMENTAL MONITORING

Environmental Monitoring

Risk-Based Environmental Monitoring. Marsha Stabler Hardiman Senior Consultant Concordia ValSource Wednesday September 17, 2014 FDA/PQRI

Everything you want to know about USP 797

USP <797> Cleanroom Design and Environmental Monitoring. Andrew King, USP <797> Specialist CETA Member RCCP-SC

Regulations Concerning

GUIDELINES ON TEST METHODS FOR ENVIRONMENTAL MONITORING FOR ASEPTIC DISPENSING FACILITIES

International Standard ISO 14644

CLEAN ROOM MONITORING REGULATORY STANDARDS

Manufacturing. Environmental Monitoring Particle Counts Are Easy B IOP ROCESSTECHNICAL. Scott E. Mackler

Facility Cleaning & Monitoring. Cleaning

Validating and Monitoring the Cleanroom

Particle Monitoring Requirements in Pharmaceutical Cleanrooms

Qualification of an Environmental Monitoring Program

The use of risk assessment tools for microbiological assessment of cleanroom environments. by Tim Sandle

CLASSIFICATION OF CLEANROOMS

Cleanroom. For. Sterile Manufacturing Facilities

Raleigh, NC May 12 th & 13 th Meeting The New ISO Cleanroom Standards And Changing EU Guidance How Will You Comply?

Design, Construction, Commission, and Qualification of Critical Utility Systems: Part III

Cleaning. By the end of this chapter, you will be able to: Introduction. Definitions. Chapter 9

Particle Counting and Environmental Monitoring In Pharmaceutical / Life Sciences

Understanding USP 797

Risk Based Environmental Monitoring (EM) and EM Data Management and Trending

EU GMP Annex 1 Update 2008: Airborne Particle Counting

Hazardous Drug. Cleanroom. Standards

ENVIRONMENTAL MONITORING / TESTING TO CONFORM WITH ISO14644 & TGA GMP REQUIREMENTS

Environmental Monitoring in Isolators and Clean Rooms ICR settle and contact plates ICRplus contact plates

ENVIRONMENTAL TESTING & MONITORING: Deciphering Compliance Requirements for Pharmaceutical and Medical Device Manufacturers A WHITE PAPER

Qualification of Cleanrooms and Environmental Monitoring - Practical Approaches in Europe

TSI BIOTRAK REAL-TIME VIABLE PARTICLE COUNTER FACILITY MONITORING SYSTEMS

MOHD NASRUL MOHAMAD NOOR

Workflow System for Paperless Air Monitoring Powered by MODA. Presented by

Air and Water Balancing - Sound and Vibration Testing - Cleanroom Services - Building Commissioning Building Envelope Testing Thermal Imaging

Environmental monitoring programme in the cell therapy facility of a research centre: preliminary investigation

Cleaning and Disinfection Agenda. 1. Cleanroom Classification. Cleanroom Classification. What does contamination mean? Types of contamination

Basic Requirements For Aseptic Manufacturing Of Sterile Medicinal Products A Comparison Between Europe And USA

Environmental Monitoring Risk Assessment

GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE OF STERILE MEDICINAL PRODUCTS

Introduction. Contamination sources

Liabilities of Vented Crawl Spaces, Their Impacts on Indoor Air Quality in Southeastern U.S. Homes and One Intervention Strategy

Evaluation of Laminar Flow Microbiological Safety Cabinets

Sample Pharmacy CLEANING AND SANITIZING PROCEDURE P-304.1

Presentation at the 3 rd SAFOODNET seminar

Design, Operation and Management of GTP/GMP Cell Engineering Facilities

Environmental Monitoring of Clean Rooms in Vaccine Manufacturing Facilities

Stainless Steel Worksurface 3 Feet Hood A10-WS-PR3 A10-WS-SR3 4 Feet Hood A10-WS-PR4 A10-WS-SR4 6 Feet Hood A10-WS-PR6 A10-WS-SR6.

Lab Exercise 3: Media, incubation, and aseptic technique

Microbial Air Quality in a 50-year-old Middle School

Liabilities of Vented Crawl Spaces And Their Impacts on Indoor Air Quality in Southeastern U.S. Homes

BioLaz Real Time Microbial Monitoring in Aseptic Pharmaceutical Manufacturing. March 2013

DRAFT GUIDANCE. This guidance document is being distributed for comment purposes only.

USP <797> A Road to Compliance The New Mexico Board of Pharmacy

Risk Assessment: Biosafety Cabinet

Guidelines for Mold Remediation (Removal)

ISO A Standard Methodology to Optical Particle Counter Calibration and What It Means to Cleanroom Owners

Quality Assurance in Blood Cell Labelling

Laminar Flow Cabinets and Workstations

Annex 2 WHO good practices for pharmaceutical microbiology laboratories

Rules for Compounded Sterile Preparations (CSPs)

BIOLOGICAL SAFETY CABINET PROGRAM

CLEANROOMS IN PHARMACEUTICAL PRODUCTION

Making Sense of Your Environmental Monitoring Data. Presented by Dawn McIver MicroWorks, Inc.

USP <797> Introduction

Microbiological Testing of the Sawyer Mini Filter. 16 December Summary

Evaluation of Microbial Growth and Survival on Construction materials treated with Anabec NewBuild 30

Indoor air quality monitoring made easy

ATS-SOI-5910 Page: 1 of 7. Approval Block. Prepared by: Signature Date. Evan Parnell 04 AUG Reviewed by: Signature Date. Brian Flynn 04 AUG 2014

MODULE 2D ENVIRONMENTAL MICROBIOLOGICAL LABORATORY ACCREDITATION PROGRAM (EMLAP) ADDITIONAL REQUIREMENTS

EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL. EudraLex The Rules Governing Medicinal Products in the European Union

COMPOUNDING PHARMACY IN THE HOSPITAL SETTING SATURDAY/11:30AM-12:30PM

BIOLOGICAL ENVIRONMENTAL MONITORING IN PREVENTIVE CONSERVATION OF PAPER HERITAGE

Hand and Glove Hygiene Keys to Safe Compounding

THE MICROBIAL ID BREAKTHROUGH: How DNA Sequencing Services Help Prevent Catastrophic Cleanroom Shutdowns

CLEAN ROOM TRAINING CLEAN ROOM AREAS

Contamination Control and Environmental Monitoring Systems

DISCUSSION TOOL PRESENTED TO THE AABB CT REGULATORY AFFAIRS SUBSECTION

Particle testing in cleanroom high-pressure gas lines to ISO made easy with the MET ONE 3400 gas calibrations

CONTAMINATION CONTROL IN HOSPITALS. Isabelle Pautrel Ingénieur Clean Concept Patriarche & Co i.pautrel@patriarche.fr

SPECIAL APPLICATIONS

STUDIES ON THE AIR QUALITY IN A DAIRY PROCESSING PLANT

Transferring a Broth Culture to Fresh Broth

Lecture 30: Cleanroom design and contamination control

AMENDED January 27, 2015

HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions

Aseptic preparations, including TPN, for a limited number of patients

Spetec. Clean room. technology. Laminar flow box Clean room workbench CleanBoy Clean room cell Service, certification

Oakland Unified San Jose Unified Stanford University Santa Ana Unified Newhall Unified Clovis Unified Merced Union High School Grossmont Union High

The Microbial Bioburden of USP 797 Compliance. Simplifying Environmental Quality and Control Practices for Pharmaceutical Compounding

One Detection Technology. Three Applications. One Automated Platform.

VALIDATION OF CLEAN ROOMS FOR ASEPTIC MANUFACTURING. F.R.Smal Pharmaceutical Director ICCE ICCE a member of SNC-Lavalin Group

A Basic Introduction to Clean Rooms

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

WHO GOOD PRACTICES FOR PHARMACEUTICAL MICROBIOLOGY LABORATORIES DRAFT FOR COMMENT

BACTERIAL ENUMERATION

FS209E and ISO Cleanroom Standards

UTILIZATION of PLASMA ACTIVATED WATER in Biotechnology, Pharmacology and Medicine. JSC TECHNOSYSTEM-ECO Moscow, Russia April, 2009

WIBObarrier OCS - Open Containment Systems WIBObarrier CCS - Closed Containment Systems

Transcription:

Environmental Monitoring

Purpose of Environmental Monitoring Critical process within the pharmaceutical and biotechnology industries. Determines the microbial and particulate content of cleanroom air and surfaces. Highlights conditions contributing to excessive microbial & particulate levels due to ineffective cleaning, or personnel/equipment issues (Trending). Alerts to conditions exceeding classifications Pro-active tool for Quality Assurance

Who Does It? Quality Control Demonstrate product safety Environmental Monitoring Testing Quality Assurance Oversight responsibilities ensure compliance with GMPs Review and Approve all Records, Reports, written procedures, specifications Audit methods, results, systems and processes

Classifications Critical Environment Classification Concentration (particles/meter³) > or = Size Shown FS 209E ISO 14644-1 0.1 µm 0.2 µm 0.3 µm 0.5 µm 1.0 µm 5.0 µm N/A 1 10 2 N/A 2 100 24 10 4 1 3 1,000 237 102 35 8 10 4 10,000 2,370 1,020 352 83 100 5 100,000 23,700 10,200 3,520 832 29 1,000 6 1,000,000 237,000 102,000 35,200 8,320 293 10,000 7 352,000 83,200 2,930 100,000 8 3,520,000 832,000 29,300 N/A 9 35,200,000 8,320,000 293,000

To be monitored Non-viable airborne particulates Viable airborn particulates Viable surface bound particulates on cleanroom surfaces and personnel Contamination Sources: People ~75% Ventilation ~15% Room Structure ~5% Equipment ~5%

Particle Counter (Measures non-viable airborne particles) Non-Viable Particulate Monitoring - ISO 14644, Fed Std-209E, USP <1116> A calibrated laser particle counter used to sample a defined volume of air. Can measure a variety of particle sizes, most commonly 0.5 and 5.0 micron. Particle counts are recorded as the number of particles per volume of air sampled. Results can be reported per cubic foot, per FDSTD 209E, or per cubic meter, per ISO 14644.

Particle Counters Handheld are ideal for spot checking. Important for tracking down a source of contamination, testing filters, and verifying the cleanroom is working within specified parameters. http://www.particlecounters.org/cleanroom/#moreinfo

Settling Plates (Viable airborne particulates) Passive Air Monitoring - ISO 14644, Fed Std- 209E, USP <1116> Settling plates filled with media are used to sample the microbial fallout over time. The plates are incubated to promote growth Microorganisms are counted and results are reported as the number of CFU (colony forming units) per time sampled.

Settling Plates In the absence of any kind of influence, airborne microorganisms, typically attached to larger particles, will deposit onto open culture plates. Microorganisms are usually found in the air of occupied rooms rafted onto skin cells. Very few present on their own. The average size of microbial particle will deposit, by gravity, onto surfaces at a rate of approximately 1 cm/s.

Sample Locations for Settling Plates Areas where there is little air movement (i.e. "dead spaces") or where airflows converge or are excessively turbulent. These conditions are most likely to occur: adjacent to doors in pass through hatches at low level return air grilles between HEPA's in clean rooms in corners of rooms Areas within the clean room where there is personnel activity or where specific operations are carried out.

Particle Characteristics 50 micron particles are visible Average human hair is about 100 microns Time to fall 1 meter in still air 33 seconds for 10 micron particle 48 minutes for 1 micron particle

Air Sampler (Viable airborne particulates) Viable Particulate Air Monitoring - ISO 14644, Fed Std-209E, USP <1116> Used to sample a defined volume of air, embedding viable particulates onto sterile media strips. The media strips are incubated to promote the growth of viable particulates The microorganisms are counted and results are reported as the number of CFU (colony forming units) per volume of air sampled.

RODAC Plates (Viable, Surface-Bound Particles) Surface Monitoring - ISO 14644, Fed Std- 209E, USP <1116> Contact plates (RODAC Plates) filled with media are used to sample tabletops, walls, benches, floors, garments, and gowned personnel. Measure the number of microorganisms per area sampled. Plates are incubated to promote growth, the microorganisms are counted and results are reported as the number of CFU (colony forming units) per area sampled.

RODAC: Replicate Organism Detection and Counting. flat agar surface is above the edges of the dish (so you can press it on flat surfaces) and a grid, allowing counting of cfu per cm².

Personnel gown monitoring RODAC plates are also used to monitor the contamination level of personnel gowns and Personal Protective Equipment (PPE) before or during manufacturing production. http://www.microcln.com/html/environmonitoring.htm

Rodac Plates One objective of surface sampling is to determine the efficiency of routine cleaning procedures in removing contamination. Sampling is done before and after cleaning. The medium in the plates contains neutralizing agents, which inactivate residual disinfectants on the surface to be tested, allowing comparative results before and after cleaning.

Viable Particle Testing (Settling Plates, Air Samplers, RODAC Plates) Use a growth medium with low selectivity i.e. capable of supporting a broad spectrum of microorganisms including bacteria, fungi, yeast and molds. TSA (Tryptone Soya Agar) supports general microbial colonies. SDA (Sabouraud Dextrose Agar) supports yeast and fungal colonies. TSA plates are incubated at 30-35 C for 3 days SDA plates are incubated at 20-25 C for 5 days. When necessary to detect or search for a particular type of microorganism a selective culture medium should be used.

Positive and Negative Controls Typically two positive controls and two negative controls Positive: B. Subitilis (Bacteria) C. albicans (Fungus) Negative: Unopened Plate Real Time = Opened and immediately shut

Time of Testing Sampling should take place with the facility in the operational condition (personnel present and normal operations being carried out). The operational condition for sterile hoods and transfer devices can be considered to be when an operator is working in any part of the clean air device. Sampling in the static condition should be performed at an agreed frequency to monitor baseline contamination levels.

Frequency of Testing For Class 10,000 and Class 100,000 Rooms Type of Monitoring Non-Viable Particulates Viable Airborne Particulates Viable Surface Monitoring Incubator Centrifuge Method Particle Counter Settling Plates Rodac Plates Rodac Plates Rodac Plate Areas to be Monitored Class 10,000 Class 100,000 Class 10,000 Class 100,000 Class 10,000 Class 100,000 Frequency Weekly Weekly Monthly Monthly Weekly Weekly Interior, Class 10,000 Weekly Interior, Class 10,000 Weekly

Personnel Monitoring (Frequency) Type of Monitoring Method Frequency Right hand (two fingertips) Left hand (two fingertips) Right Sleeve Left Sleeve Rodac Plates Rodac Plates Rodac Plates Rodac Plates After all Vialing operations and once/month random After all Vialing operations and once/month random After all Vialing operations and once/month random After all Vialing operations and once/month random

How many samples? The number of sampling locations is based on the size of the room. Determining the number of sampling locations is based on the formula: nl = A nl is the minimum number of sampling locations (round up to the next whole number), and A is the floor area of the cleanroom in m².

How Many Samples? The sample locations should be evenly distributed within the area under test. A site plan should be prepared indicating sampling locations. nl = A 15 ft x 12 ft = 180 ft 2 10.69 ft 2 = 1m 2 180 ft 2 /10.69ft 2 /m 2 = 16.83 m 2 = 17 sample locations 12 ft 15 ft.

Out of Specification? Alert Level alert levels are quality levels that, when exceeded, signal a possible deviation from normal operating conditions and may not require action, but may need to be monitored more closely. Action Level action levels are quality levels that, when exceeded, signal an apparent deviation from normal operating conditions and requires immediate action.

Alert & Action Levels Air Classification Alert Level 100 Non Viable Particulate Count Rodac Plate Surface Counts Settling Plates (0.5 μm particles/ft 3 ) (cfu/plate) (cfu/14cm plate) 50 (at rest) 2 1 80 (operational) 10,000 8000 4 3 100,000 80,000 5 5 Air Classification Action Level Non Viable Particulate Count (0.5 μm particles/ft 3 ) Rodac Plate Surface Counts (cfu/plate) Settling Plates (cfu/14cm plate) 100 99 (at rest) 3 2 10,000 9999 5 5 10 for floors 100,000 99999 20 floors dirty side 30 for floors 20

Personnel Monitoring Sample site Alert Action Hand 1/plate 3/plate Sleeve 1/plate 3/plate

Actions to take when levels are breached Identify Possible cause Contaminating microorganisms Investigate Whether isolated sample or whole area involved Personnel - operator status (grade), level of training, health, technique, wash up Cleaning procedures Changing procedure HEPA filter integrity of room/clean air device Processes carried out Previous test results for trends or other identified problems. Liase with Aseptic personnel Microbiology personnel QA/QC personnel

This material is based upon work supported by the National Science Foundation under Grant No. 0438229. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the National Science Foundation.