What you need to know about. Smoke alarms for residential buildings



Similar documents
Practice Note

Smoke Alarms. New smoke alarm requirements for existing buildings from 1 May Introduction. Advisory note March 2006

SMOKE ALARMS CLASS 1A BUILDINGS

DOMESTIC SMOKE ALARMS

Smoke Alarm Legislation Frequently Asked Questions

Home Owners Guide to Smoke Alarm Safety

Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems

Smoke Alarm Legislation

SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective

Building Control. Householder Guidance Leaflet No. 29. Fire detection in dwellings

Fire precautions in dwellings. Private sector housing Providing homes building communities

FIRE DETECTION AND ALARM SYSTEMS

MUNICIPALITY OF KAZABAZUA. SMOKE DETECTORS By-Law number

BUILDING CONTROL GUIDANCE SHEET SMOKE ALARMS IN STANDARD DWELLINGS Last updated 16/12/2010

Compliance Document for New Zealand Building Code Clause F7 Warning Systems Fourth Edition

Fire Alarm system Installation Guide

720r Addendum: Siting the 720r

SMOKE ALARM MAINTENANCE PROGRAM

Northern Ireland Housing Executive: HMO Fire Safety Guide

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

RHODE ISLAND DIVISION OF STATE FIRE MARSHAL

Fire Standards & Regulations Are you confused?

LONDON BOROUGH OF BROMLEY STANDARDS FOR HOUSES IN MULTIPLE OCCUPATION (HMO) INTRODUCTION

Minimum Housing and Health Standards

INSTALLER INSTRUCTIONS

Danville, IN Code of Ordinances CHAPTER 90: ALARM SYSTEMS, SMOKE DETECTORS AND THE LIKE. Alarm Systems. Smoke Detectors. Key and Data Storage Boxes

HOUSES IN MULTIPLE OCCUPATION STANDARDS. Housing Executive

WATER INDUSTRY ACT South Australian Water Heater Installation Requirements. Prepared by the Technical Regulator

Smoke Alarms Save Lives!

London Borough of Barnet. Fire Safety in Houses in Multiple Occupation. A Guide to Landlords

For use by landlords of small premises Premises Address

Practice Note

SPECIFIC GUIDANCE FOR A HOUSE IN MULTIPLE OCCUPATION (HMO) CONVERTED ENTIRELY INTO SELF CONTAINED FLATS

CERTIFICATE OF COMPLIANCE

SUBCHAPTER F. SMOKE ALARMS AND FIRE EXTINGUISHERS

OHIO BOARD OF BUILDING STANDARDS. Smoke Alarms and Fire Safety

Fire Facts Smoke Alarms

DOMESTIC SMOKE ALARMS

Introduction. CE marked construction products

READ THIS FIRST CONT.

USER S MANUAL. SMDC-16 Digital Control Communicator and SMPC-32 Personal Control

Chapter 1 Smoke alarms and fire safety measures in the home

I.S :2013 Fire Detection & Alarm Systems

Multi-storey residential buildings - warranty insurance exemption. This updates the previous Practice Note issued June 2006

MP 5.7 RESIDENTIAL SERVICES BUILDING STANDARD

Q&A: Tenancy law changes

Know Your Smoke Alarm

Requirements for Smoke/Carbon Monoxide & Fire Extinguisher Certification

For use by landlords of small premises Premises Address

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

Houses in Multiple Occupation

Application Guide HMOs

5. Financial requirements The relevant financial requirements in the board s policies.

The Alberta Fire Code requires all homes in the province to have working smoke alarms.

Smoke & Carbon Monoxide

ADVISORY NOTES for FIRE SAFETY MANAGEMENT TOOL FOR OWNER/OCCUPIERS

Fire safety for landlords

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Visit Us on the Web! MODEL USI-1122L LONG LIFE* LITHIUM POWERCELL SMOKE & FIRE ALARM WITH SILENCE CONTROL

Nationally Described Space Standard technical requirements. Consultation draft. September 2014

Contents. 1. Introduction 1.1 Reason for this Guide Interpretation 1.3 Principles of Fire Safety 1.4 Legal Provisions 4

The Smoke and Carbon Monoxide Alarm (England) Regulations 2015

1. Basic Information about your Smoke Alarm. 2. Locating your Smoke Alarm

Change of Address Form Help with your Rent and Council Tax

Building Control Guidance Note

I.S :2013 Fire Detection & Alarm Systems

Kidde Safety Europe, Mathisen Way, Colnbrook, SL3 0HB, UK. Kidde Fyrnetics 2000 SAVE THIS MANUAL FOR FUTURE REFERENCE

Department of Licenses and Inspections PARTNERS FOR GOOD HOUSING

Smoke & Carbon Monoxide

A Guide to Fire and Security Protection in Multi-Occupied Residential Properties

BS5839 Part 1:2002 Overview

2-WAY WIRELESS SUPERVISED PHOTOELECTRIC SMOKE DETECTOR. Model: EL-4703 INSTALLATION INSTRUCTIONS

EAST LONDON GUIDANCE ON HMO STANDARDS (3)

Call reduction guidance for false alarm/ unwanted fire signals

READ ALL INSTRUCTIONS

Property Accreditation Standards 2014/2015

Inspections must be conducted every three years in order to maintain an "approved" status on the City Of Bozeman Safe Rental Unit List.

Instructions for Obtaining a Certificate of Smoke Detector, Carbon Monoxide Alarm, and Kitchen Fire Extinguisher Compliance

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

How To Install A Carbon Monoxide Detector

Smoke Alarm User s Manual

Guide to Houses in Multiple Occupation Self Contained Flats

Technical housing standards nationally described space standard

Queensland Development Code Mandatory Part 6.1 Commissioning and maintenance of fire safety installation

LOUTH COUNTY COUNCIL STATEMENT OF POLICY ON DOMESTIC FIRE DETECTION AND ALARM SYSTEMS

2007 ICC FINAL ACTION AGENDA

Planning for Bushfire Risk Mitigation General Code

USER S MANUAL TABLE OF CONTENTS INTRODUCTION. SMOKE ALARM WITH TEN-YEAR NON-REPLACEABLE LITHIUM POWERCELL Model SA340

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

Do you have paying guests?

Transcription:

What you need to know about Smoke alarms for residential buildings

Are s compulsory? Smoke alarms are compulsory and must be installed in residential buildings on or near the ceiling of every storey. What type of should be used? Smoke alarms must meet the Australian Standard AS 3786-1993 required by the Building Regulations 2006 (the Regulations). In all new residential buildings, constructed on or after 1 August 1997, the s must be connected directly to the consumer power mains as well as having a battery back-up. This applies to hospital residential care buildings, small boarding houses and other residential buildings, such as residential parts of a hotel, hostel, school and aged care facility. Residential buildings constructed before 1 August 1997, can be fitted with a battery-powered. What residential buildings require s? The Regulations require self-contained s to be installed in all residential buildings including dwellings within buildings of other non-residential use. The following building Classes as broadly defined in the Building Code of Australia 2010 (the BCA) are included: Class 1a: Detached houses, row houses, town houses, terrace houses or villa units Class 1b: Some boarding houses, guest houses or hostels Class 2: Buildings containing sole-occupancy units (e.g. apartments, blocks of flats) Class 3: Backpacker accommodation, residential parts of hotels or motels, residential parts of schools, accommodation for the aged, disabled or children Class 4: Dwellings in non-residential buildings (e.g. houses attached to shops). You should familiarise yourself with the Class of building in which you intend installing your, as this will affect its required location. If you are renting a dwelling or unit, it is the owner s (landlord s) responsibility to ensure s are installed and kept in working condition. However, a tenant can take action to ensure compliance with the Regulations. Where should s be located? Smoke alarms are intended to detect smoke before it reaches the sleeping occupants of a building. Therefore, the alarm should be located in a position designed to wake the occupants and give them time to evacuate the building. Class 1 buildings Class 1a: Detached houses, row houses, town houses, terrace houses or villa units Class 1b: Some boarding houses, guest houses or hostels To protect any area used for sleeping in Class 1 buildings, the must be located between each area containing bedrooms and the remainder of the dwelling. In some dwellings the bedrooms are located in a common area and connected by a hallway. In this instance, the alarm must be located as shown in Diagram 1. If the bedrooms are not grouped in a common area or there is no connecting hallway, then an alarm must be located within 1.5 metres of the entrance to each bedroom as shown in Diagram 2. An additional is required in any other storey that is not already provided with a. The location for this alarm must be in the path that people will most likely take to evacuate the building. This will ensure an alarm will be raised before the smoke makes the common exit impassable. If the other storey is not connected to the remainder of the building, then the alarm must be centrally located in the lower area. In all cases, s must be audible throughout all storeys. One way of achieving this is to interconnect the alarms so they will sound when the alarm within the sleeping area is activated.

Diagram 1 Smoke alarms in hallways Diagram 2 Residential building with separate sleeping areas kitchen bedroom 1 bedroom 2 living room/kitchen bathroom/ laundry bedroom 1 wc living room bedroom 3 bathroom bedroom 2 Diagram 2 Residential building with separate Class 2 buildings sleeping areas Class 2: Buildings containing sole-occupancy units (e.g. apartments, blocks of flats) living room/kitchen bathroom/ To protect any area used for laundry sleeping in Class 2 buildings, the smoke bedroom 1 alarm must be located as per Diagram 1 and Diagram 2. In other areas (public corridors, lobbies etc.) s must be installed not more than 5 metres from any wall and not more than 10 metres between s. These alarms must be audible to sleeping residents within the sole-occupancy units. If there are other storeys not connected to the remainder of the building bedroom or any 2part of a public corridor, then an alarm must be centrally located in the lower storey area. In all cases, the alarm must be audible throughout all storeys. It is advisable to interconnect the alarms so that the alarms within the sleeping areas of the sole-occupancy units are activated at the same time. Class 3 buildings Class 3: Backpacker accommodation, residential parts of hotels or motels, residential parts of schools, accommodation for the aged, disabled or children To protect any area used for sleeping in Class 3 buildings, the smoke alarm must be located as per Diagram 1 and Diagram 2. In addition to providing s to sole-occupancy units, a must be installed in all other habitable rooms except for kitchen areas that may install suitable self-contained heat (thermal) alarms. As before, the alarms must be audible in the sleeping areas of the sole-occupancy units. Class 4 parts of buildings Class 4: Dwellings in non-residential buildings (e.g. houses attached to shops) To protect any area used for sleeping in Class 4 parts of buildings, the must comply with the provisions for Class 1 dwellings. In addition, they must have s within any non-fire-isolated exits and any public corridor areas serving the Class 4 part of the building unless the building is sprinkler protected. Where should s be fitted? Smoke alarms must be installed on or near the ceiling with care taken to avoid dead air spaces. A dead air space is an area in which trapped air may prevent smoke from reaching the alarm. This space generally occurs at the apex of cathedral ceilings, the corner junction of walls and ceilings and between exposed floor joists. If it is impractical to mount the smoke alarm on the ceiling, it may be located on the wall. The top of the must be between 300 mm and 500 mm below the ceiling (see Diagram 3). Diagram 3 Dead air space and proper mounting of s on side walls. dead air space dead air space top of located here must be located between 500 mm - 1500 mm of the apex 300 mm side wall 300 mm min 500 mm max The distance from the apex of a cathedral ceiling to the top of the alarm must be between 500 mm and 1500 mm.

What are the maintenance requirements for s? For s to be effective, it is important that they are maintained. The operation of most s can be checked by depressing a button on the outside of the alarm. The test should be conducted in accordance with the manufacturer s instructions. The battery in most s will need to be replaced on an annual basis (lithium ion batteries last up to 10 years). Smoke alarms will emit a warning sound when the battery needs to be replaced (a high pitched single beep every 30 seconds). The alarm should be cleaned regularly to remove dust particles that may affect the operation of the unit. Maintenance guidance is provided in the manufacturer s installation and operation details. Who can install s? Smoke alarms that are hard wired to an electricity supply, require a qualified electrician to install them. Battery operated s can be installed by anyone. If you need assistance, contact a service organisation or local council for advice. How are false alarms minimised? Smoke alarms are sensitive and may detect smoke and moisture created by common household activities. To reduce the likelihood of false alarms, do not locate s near cooking appliances and bathrooms. If false alarms persist, then the should be moved to a more suitable location or a different type of installed. Should s be interconnected? As it is inexpensive to interconnect alarms, it is advisable that smoke alarms be interconnected. However, there is no requirement for interconnection. Are there penalties for non-compliance? A fine of up to $600 could be imposed on an owner who fails to comply with the requirements of the Regulations. It is advisable to interconnect the alarms so that the alarms within the sleeping areas of the sole-occupancy units are activated at the same time.

Smoke alarms are intended to detect smoke before it reaches the sleeping occupants of a building.