2012-01. Multi-storey residential buildings - warranty insurance exemption. This updates the previous Practice Note 2006-01 issued June 2006



Similar documents
Practice Note

Practice Note

Practice Note

What you need to know about. Smoke alarms for residential buildings

Overview of Hotel Fire Safety Requirements

Smoke Alarm Legislation Frequently Asked Questions

Smoke Alarms. New smoke alarm requirements for existing buildings from 1 May Introduction. Advisory note March 2006

Guide to lodging a certified building permit application (form BA1)

ADVISORY NOTES for FIRE SAFETY MANAGEMENT TOOL FOR OWNER/OCCUPIERS

SMOKE ALARMS CLASS 1A BUILDINGS

What you need to know about. Being an owner-builder

VIC - Builders Home Warranty Insurance Multi Unit Development Application

It is against this refusal that the appellant appealed to the Secretary of State.

Residential Investment Property Tax Depreciation Explained

BUILDING CERTIFIERS GUIDE TO BSA INSURANCE & OWNER-BUILDER REQUIREMENTS FOR RESIDENTIAL CONSTRUCTION

Ministry of the Environment Decree. on housing design

Hole In One. Freehold 425,000 + VAT SOLE SELLING RIGHTS REF: NW Forest Drive, Lytham, St Annes, Lancashire FY8 4QF

DAYBREAK ATTACHED RESIDENCE DISCLOSURE STATEMENTS Acknowledgement of Receipt Form

Compliance Document for New Zealand Building Code Clause F7 Warning Systems Fourth Edition

GUIDELINES FOR FILING SCHEDULE OF SHARE VALUES UNDER THE BUILDING MAINTENANCE AND STRATA MANAGEMENT ACT

PERFORMANCE OF VICTORIA S DOMESTIC BUILDING INSURANCE SCHEME

VIC - Owner Builder - Home Warranty Insurance Application Form

GENERAL FIRE SAFETY TERMS & DEFINITIONS

The following should be seen only as general guidelines;

DIRECTOR S INTERPRETATION

Ministry of the Environment Decree on accessible building

Version Decision Number Adoption Date History 1 20\ /02/10 Adopted 2 3 4

fire separating walls #2

Home Owners Development Contract Form - Correctly Provide Details

Victoria - Builders Home Warranty Insurance Job Specific Application Form

Becoming an owner-builder

New York City Department of Buildings

Schedule B to By-law

3.In making the following determination, the Secretary of State has not considered whether the plans conform to any other relevant requirements.

Australian Institute of Building Submission to the Review of the New South Wales Home Building Act 1989

WATER INDUSTRY ACT South Australian Water Heater Installation Requirements. Prepared by the Technical Regulator

Decree of the Ministry of the Environment. on fire safety of garages

FOR SALE / TO LET ASTON HOUSE SCHOOL, 10 MONTPELIER ROAD, EALING, LONDON W5 2QP

5. Financial requirements The relevant financial requirements in the board s policies.

Kerin Benson Lawyers Fact Sheet 4

BUILDING OR RENOVATING

Building Permit Information House Relocation

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

Arts Revitalisation Projects and the Planning System. January 2010 Guideline

Victoria Government Gazette No. S 98 Friday 23 May 2003 By Authority. Victorian Government Printer

Schedule B to By-law Part A Fees Payable for Permits

Nationwide House Energy Rating Scheme (NatHERS)

APPLICATION FOR ELIGIBILITY FOR DOMESTIC BUILDING INSURANCE

Essential Safety Measures Maintenance Manual

Smoke Alarm Legislation

Houses in Multiple Occupation

The subject matter of this report deals with the following Council Objectives

Building Permit Audit

C:\Documents and Settings\panot\Local Settings\Temporary Internet Files\OLK60\Guide to Home Warranty Ins FINAL.doc

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

Master Builders Association (NSW) Excellence in Housing Awards Winner 2009 & 2010

Master Builders Association (NSW) Excellence in Housing Awards Winner 2009 & 2010

Australian Standard. Emergency control organization and procedures for buildings, structures and workplaces AS

Home Warranty Insurance Claim Form

IFE Level 4 Certificate in Fire Science and Fire Safety (HL)

GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)

Coast and Country Insurance Consultants Pty Ltd General Insurance Department

Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems

Assessor Advice Re: CPC and CPC08 Training Packages

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

Design & Access Statement : Proposed Internal Devlopment & External Plant to Data Centre Facility, 35 Imperial Way, Croydon.

PROPERTY FOR LEASE. 3 rd Floor Office Suite, Maxwell House, Armada Way, Plymouth PL1 1HZ

KBC Chapter 34 : Applying the Kentucky Building Code to Existing and Historic Buildings

NSW Home Warranty Insurance Scheme. Information on the Scheme as at. 31 March 2014

Building Control Guidance Note

Home Warranty Insurance Why is it such a mess?

Fire precautions in dwellings. Private sector housing Providing homes building communities

company profile prepared by

BUILDING CERTIFIERS GUIDE TO QBCC INSURANCE & OWNER BUILDER REQUIREMENTS FOR RESIDENTIAL CONSTRUCTION

GLENORCHY CITY COUNCIL PLUMBING SEWERAGE AND DRAINAGE SERVICE FEES SCHEDULE

FURNITURE & FURNISHINGS - FIRE SAFETY STANDARDS

Building Control Guidance Note

Norfolk House Hotel Development Gatwick Airport. Flood Risk Statement. May Bloc Hotels. Vantage Planning Ltd.

Northern Territory Owner-Builder Manual

Australian/New Zealand Standard

Home Warranty Insurance Briefing Note

Livable Housing Design Guidelines

TEMPORARY ACCOMMODATION

Owner-Builder VIC Resıdentıal Constructıon Warranty Insurance

COMPLYING DEVELOPMENT CERTIFICATE APPLICATION Environmental Planning and Assessment Act 1979 Sections 85/85A

Law No. (9) of 2012 Amending some provisions of Law No. (13) of 1997 Concerning the Civil Defense

TO LET Ideal Starter Warehouse / Light Industrial Unit

CONSTRUCTION COST GUIDE

APPEAL AGAINST REFUSAL TO RELAX OR DISPENSE WITH REQUIREMENTS ON A MATERIAL CHANGE OF USE

Guide to Buying a New Build Home

225 MARSH WALL LONDON E14 9FW Offices To Let On Flexible Terms

Menu of Architecture Services 2009

OWNER BUILDER AS AN WHAT ARE MY RESPONSIBILITIES UNDER THE DEVELOPMENT ACT 1993

SCHEDULE A BY-LAW B-6 CLASSES OF PERMITS AND FEES

DEPARTMENT OF PLANNING AND DEVELOPMENT

Marsh Pty Ltd. Victorian Competition and Efficiency Commission. Following the Release of the Draft. Report July 2005

Calliden Builder Warranty Insurance. South Australia and Western Australia. About Calliden. The Agent. Privacy Statement. Important Information

Fire Safety Regulation, a comparative perspective, Ireland v Poland. Piotr Smardz

NSW Housing Code A guide to complying development

Swindon Borough Council. Resident Parking Permit Terms and Conditions of Use

Transcription:

Multi-storey residential buildings - warranty insurance exemption This updates the previous Practice Note 2006-01 issued June 2006 2012-01 Reference to the BCA Volume One in this Practice Note means Volume One of the National Construction Code Series. (1) SUMMARY This Practice Note explains the regulations that provide an exemption for warranty insurance requirements for multi-storey residential buildings. (2) BACKGROUND The Victorian and NSW governments agreed to changes to builders warranty insurance for residential developments in a 10-point plan announced in March 2002. One point in that plan removes the mandatory requirement for builders of multi-storey residential buildings to provide warranty insurance. That change now forms Div 3 Part 18 of the Building Regulations 2006 (the Regulations). An exemption from the provision of warranty insurance applies if a builder carries out domestic building work under a major domestic building contract for the construction of a multi-storey residential building. The exemption applies to a major domestic building contract entered into on or after 10 April 2002. (3) WHAT IS A MULTI-STOREY RESIDENTIAL BUILDING? Regulation 1807 introduces a new definition for a multistorey residential building. A multi-storey residential building is a building that has a rise in storeys of more than 3, and contains 2 or more separate dwellings. The number of storeys contained in a building can differ from the rise in storeys. The building relates to the works that a builder proposes to construct under a major domestic building contract. The provision of firewalls to separate parts of a building will not satisfy the exemption provisions. The entire building must be considered. The provision of fire separation to create separate buildings is only applicable to Sections C, D & E of the Building Code of Australia (BCA) Volume One, and does not apply to Div 3 Part 18 of the Regulations. Where it is proposed to construct two separate (detached) buildings on the same allotment each building must be assessed separately. Examples of buildings are contained in Appendix A. Contents (1) Summary 1 (2) Background 1 (3) What is a multi-storey 1 residential building? (4) What does a storey include? 1 (5) Relevant Building Surveyor 1 responsibilities (6) Owner-builder exemptions 2 (7) APPENDIX A 2 (4) WHAT DOES A STOREY INCLUDE? The provisions relate to a rise in storeys in determining whether a building is multi-storey. The method for calculating the rise in storeys is set out in Clause C1.2 of BCA Volume One. The rise in storeys for Div 3 Part 18 relates to the work described in the major domestic building contract. The definition of a storey is stated in Clause A1.1 of BCA Volume One. This Clause should be read, as some spaces are excluded. According to the definition in Div 3 Part 18, a space within a building that only contains accommodation for vehicles is not considered a storey for the purposes of calculating the rise in storeys. Therefore, a car park situated at ground level that contains nothing other than vehicle accommodation is not a storey. If the car park contains other facilities (such as storage areas and entrance foyers) it is then considered a storey. However, if the car park only contains stairways that provide emergency exits from the car park level, lifts and associated lift lobbies it is not considered a storey. Examples of buildings are contained in Appendix A. (5) RELEVANT BUILDING SURVEYOR S RESPONSIBILITIES The Relevant Building Surveyor (the RBS) is responsible for determining what the rise in storeys is at the time of reviewing the drawings provided with application for the building permit. Page 1 of 5

Section 24A(1) of the Building Act 1993 (the Act) requires that the RBS not issue a building permit unless, in the case of domestic building work, each builder is registered in the appropriate class of domestic builder and is covered by the required insurance (as specified in the Ministerial Insurance Order). The new regulations create an exemption for multistorey residential buildings and the RBS must determine whether the exemption applies. FIGURE 2 (6) OWNER-BUILDER EXEMPTIONS An owner-builder of a multi-storey residential building is exempt from the requirement to provide the relevant warranty insurance, when entering into a contract to sell the dwelling or building. However, an owner-builder is not exempt from providing a report as require under section 137B (2) of the Act. This applies to any contract of sale entered into on or after 10 April 2002. Note: Top floor is a mezzanine and a storey as per BCA Volume 1, Clause C 1.2 (d)(i) FIGURE 3 (7) APPENDIX A Examples of buildings in reference to warranty insurance requirements. Legend: Figures are sectional elevations Figures 1-14 are for constructions of new buildings Figures 15 & 16 are for existing buildings 7 Class 7, space only for vehicle accommodation 2 Class 2, separate dwelling 5 Class 5, office 6 Class 6, shop GL FIGURE 1 Ground level Warranty insurance is required Warranty insurance not required Note: Top floor is a mezzanine but not storey as per BCA Volume 1, Clause C 1.2(d)(i) FIGURE 4 Page 2 of 5

FIGURE 5 FIGURE 8 Note: The Class 7 floor only contains accommodation for vehicles, therefore not considered a storey. Fire escape stairways and lift lobbies are allowed. FIGURE 6 Note: The floors below ground level are not considered in the calculation of rise in storeys as per BCA Volume 1 Clause C 1.2(b)(ii). The Class 7 floors only contain accommodation for vehicles, therefore they are not considered a storey. Fire escape stairways and lift lobbies are allowed. FIGURE 9 Rise in storeys = 2 Note: The Class 7 floors only contain accommodation for vehicles, therefore they are not considered a storey. Fire escape stairways nd lift lobbies are allowed. FIGURE 7 Note: The floor below ground level is not considered in the calculation of rise in storeys as per BCA Volume 1 Clause C 1.2(b)(ii). Note: In the example above, the works described in the major domestic contract are for the construction of the Class 2 components. When measured from ground in storeys of one. The floors below ground level are not considered in the calculation of rise in storeys as per BCA Volume 1, Clause C 1.2(b)(ii). Page 3 of 5

FIGURE 10 FIGURE 12 Note: In the example above, the works described in the major domestic contract are for the construction of the Class 2 components. When measured from ground in storeys of one. The floors below ground level are not considered in the calculation of rise in storeys as per BCA Volume 1 Clause C 1.2(b)(ii). building contract are for the construction of the Class 2 and 7 components. When measured from ground in storeys of four. FIGURE 13 FIGURE 11 building contract are for the construction of the Class 2 and 7 components. When measured from ground level, the contracted works show a building with a rise in storeys of three. building contract are for the construction of the Class 2 and 7 components. When measured from ground level, the contracted works show a building with a rise in storeys of three. Page 4 of 5

FIGURE 14 FIGURE 16 building contract are for the construction of the Class 2 and 7 components. A fire wall has been used to separate the two storey Class 5 and Class 2 part of the building from the remainder. The provision of fire walls only relates to a part of a building being regarded as a separate building for the purposes of Sections C, D and E of Volume 1 of the BCA in accordance with Clause C2.7 (b). The provision of fire walls is not relevant to determining the requirement for insurance. The building shown above has a rise in storeys of four. This is because the ground floor storey is a Class 7 and Class 5 part and is therefore regarded as a storey and with the three storeys of Class 2 above, totals a rise in storeys of four. FIGURE 15 Note: The requirement for insurance relates to the work described in the major domestic building contract. In the example above, the contract is for the construction of an additional single storey. When measured from ground level, the contracted works show a building with a rise in storeys of one. Note: In the case above, the existing building is being refurbished and converted to a Class 2 building. The major domestic building contract describes work related to the construction of alterations which, when measured from ground level, has a rise in storeys of four. The definition of construct in the Building Act 1993 includes alterations to a building and so the exemption from the provision of warranty insurance will apply even though the walls and supporting structure are not part of the construction. Further Note: If figure 16 where a proposed new building constructed as shell and core it would also be exempt. If the major domestic building contract for the fitout described works relating to a rise in storeys of more than 3 (the entire building), then the exemption from the provision of warranty insurance would again apply. However, if a major domestic building contract described works relating to the fitout of a single dwelling or part of the building affecting no more than a rise in storeys of more than three then the exemption would not apply. ~ If you have a technical enquiries please email technicalenquiry@buildingcommission.com.au or phone 1300 815 127 Building Commission 733 Bourke Street Docklands VIC 3008 Page 5 of 5