5178 EOI Direct Digital Controls Systems Strategic Plan Schedule A. Technical Submission. City of Richmond



Similar documents
H.V.A.C. Design Plumbing Design

A Systems Approach to HVAC Contractor Security

Fundamentals of HVAC Control Systems

BACnet protocol implementation conformance statement. Corrigo

Chapter-5 Introduction to Building Automation System (BAS)

BACnet Protocol Implementation Conformance Statement

Smart Integration of Wireless Temperature Monitoring System with Building Automation System

Guide Specification SECTION COMMISSIONING OF HVAC PART 1 - GENERAL 1.1 SUMMARY

ComfortPoint Open Building Management System. For consultants and specifiers. The Simply Smart way to optimize building control and performance

Integrated Systems Project Management Process (ISPM)

Personna PC web-based software. Q-AdminTM client. Lighting management hub (floor 2) Lighting management hub (floor 1)

Energy Design Resources Commissioning Plan Outline Template

SAUTER BACnet PICS EY-modulo 5 moduweb500 BACnet Protocol Implementation Conformance Statement

Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level

AutoLog ControlMan. Remote Monitoring & Controlling Service

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries.

Safety Requirements Specification Guideline

Find what matters. Information Alchemy Turning Your Building Data Into Money

REQUEST FOR BID. Server/Computer and VAV Controls with Backup Bid

savic-net for Integrated Building Management System

Sample - Existing Building Commissioning Plan

Integrated Building Management and Security System. Building Automation & Security.

SAUTER novapro Open: B-AWS. BACnet Advanced Workstation

Introduction to Building Automation Systems (BAS)


Technology: Heating, Ventilation and Air Condition (HVAC) Zone Controls

UNIFIED FACILITIES GUIDE SPECIFICATIONS

The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT

SECTION CONTROL SOFTWARE

Contents. Introduction

Personna PC web-based software. Q-AdminTM client. Lighting management hub (floor 1)

CHECKLIST TO DESIGNATE AREAS OF EVALUATION FOR REQUESTS FOR PROPOSAL (RFP)

Application Note #563 Revision A November 2015 Lutron / Automated Logic BACnet Integration

Impact of Control System Technologies on Industrial Energy Savings

Declaration of Conformity 21 CFR Part 11 SIMATIC WinCC flexible 2007

Building Commissioning

Tracer Summit Web Server

Supporting ANY PRODUCT employing

Integrated Building Management and Security System. Building Automation & Security.

How To Use Rittal'S Rizone

Insight Advanced Workstation

C-Bus Application Messages & Behaviour Chapter 25 Air Conditioning

No Wires No Limits With Smart Wireless Technology. V.Suresh Senior Sales Manager Emerson Process Management

Hardware & Software Solutions

Infinity 2020 Perimeter Intrusion Detection System

ADDENDUM TO THE CONTRACT. for the. Bartlett Regional Hospital Server Room Cooling System Replacement. Contract No. E12-149

MATCHDAY September 2014

NEW. EVEN MORE data acquisition and test stand automation

Help. Help Software Tutorial. Building a load sizing project with an ME Series Humidifier

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Smart. Scalable. Simple.

The Best Technology for the Application. Educating the Specifier on Medical Air & Medical Vacuum Systems

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

Control System - Enterprise Integration HVAC Concepts, Inc. (2005)

RUGGEDCOM NMS. Monitor Availability Quick detection of network failures at the port and

NSW Department of Education and Communities Dashboard User Guide

ValveLink Mobile Software

CATALYST Frequently Asked Questions

Section Q Building Automation Systems MONASH DESIGN & CONSTRUCTION STANDARDS. Page 1 of 37. Monash University Facilities and Services Division

Power & Environmental Monitoring

IBMS Specification. Specification & Design Guideline for Integrated Intelligent Building Management System. Lonix Ltd.

Audit Management Reference

Freezers - Ultrafreezers. Platilab & Irilab Series

Movicon in energy efficiency management: the ISO standard

November 3 14, 2014 Tri-State Area of Kentucky, Ohio, Indiana Orientation Courses for Advanced Manufacturing. Focus Workforce Skills Development

REAL-TIME DUST AND AEROSOL MONITORING

Smart Monitoring and Diagnostic System Application DOE Transactional Network Project

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

Commissioning - Construction Documents (Page 1 of 6)

VM600 CMS Software. VM600 Series Software for Condition Monitoring System (CMS) FEATURES DESCRIPTION

Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues

Workshop 7 PC Software - Tracker

Symmetry Networks. Corporate Managed Services Schedule

Fundamentals of LoadRunner 9.0 (2 Days)

FX07 Field Controller

Distech Controls Training

Emerson Smart Firewall

OPERATIONAL STANDARD

Managed Services Product Terms

A Proposed Integration of Hierarchical Mobile IP based Networks in SCADA Systems

DIVISION OF ENGINEERING COMPUTING SERVICES DECS SERVICE DESK. Fall & Spring: Monday Thursday 8am to 9pm. Summer & Breaks:

White Paper. Making Sense of the Data-Oriented Tools Available to Facility Managers. Find What Matters. Version 1.1 Oct 2013

Variable Air Volume - VAV

Data Services and Web Applications

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

SECTION WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM

Building Analytics Improve the efficiency, occupant comfort, and financial well-being of your building.

A. The Commissioning Authority (CxA) has been contracted or will be contracted directly with the Owner for this project.

Academic Calendar for Faculty

IDES Claimant Services TTY

Semaphore T BOX Applications in Data Center Facilities

Case Study - University at Buffalo State University of New York. Lower Energy Usage Costs with Real Time Monitoring, Campus-wide

ELECTRONIC VALUE TRANSFER CONTRACT (EVT) CREDIT CARD SETTLEMENT

Symphony Plus S+ Engineering: Composer Harmony

Radiological Assessment Display and Control System

ASX ITS Co-location Hosting Solution

L. Building Automation Systems

Passion for Innovation

THE TOWN OF GROTON IS REQUESTING PROPOSALS FOR A WIRELESS ALARM MONITORING AND CONTROL SYSTEM WITH INTERNET BASED DATA ACCESS

Transcription:

Schedule A Technical Submission City of Richmond

TABLE OF CONTENTS... 3 1 Company information... 4 1.1 Service Organization... 4 1.2 Construction Organization... 4 2 Programming Language... 5 2.1 Example of TCL or BPL... 5 3 BACnet compliance... 6 3.1 DDC Panels and Network... 6 3.2 BACnet Intra-System Communication... 6 3.3 Building Controllers (BC)... 6 3.4 Advanced Application Controllers (AAC)... 7 3.5 Field devices and Smart sensors and Actuators... 7 3.6 Operator Workstation... 7 4 Trend Logs and Graphs... 7 5 Scheduling Alarm Processing Run Analysis... 8 6 F.D.D. and Data Analytics... 8 6.1 Data Analysis Language... 8 6.1.1 Sample Analysis... 9 Appendix Forms for Part 1... 10 6.2 Service Organization Form... 11 6.3 Construction Organization Form... 12 AJA rev0 Page 2

TECHNICAL SUBMISSION The Technical Submission for this Expression of Interest (EOI) is to include the following Sections titled and ordered as follows: Section 1 - Description Organization Forms (Service and Construction) Use forms provided. Section 2 - Programming Language Example Include screen shots of the completed program sample implemented in the programming environment. Section 3 BACnet Compliance Include a drawing of a sample network and provide manufacturer s PICS statements for each proposed component. Section 4 Trend Capabilities Section 5 Scheduling, Alarm Processing Run Analysis Section 6 FDD and Data Analytics Example Include screen shots of analysis environment showing sample analysis. Section 7 Other Information as Desired by Respondent This could include information on lighting controls, wireless devices etc. Submissions should include all Sections except Section 7. Each Section to start at the top of a new page. The information requests in each Section are numbered. Submissions should include a response to each numbered information request. Each response should be provided in the order requested and should be identified with the item number. Supporting brochures may be provided at the end of each Section if desired, but should not separate the numbered responses. Submission should be delivered according to the method and format identified in any general conditions identified in the EOI. AJA rev0 Page 3

1 COMPANY INFORMATION 1.1 Service Organization Number of mechanical service trucks in Metro Vancouver. Number of DDC controls service trucks in Metro Vancouver. Total number of service trucks in Metro Vancouver. Name and telephone number of Controls Service Manager. How are normal service requests handled? Where is service dispatch office located? How are after hours service requests handled? Where is after hours service dispatch office located? What is the service rate for DDC controls service during normal hours? What is the service rate for DDC controls service for after hours? What is your usual on site response time during normal hours? What is your usual on site response time for after hours? What is your hourly charge for remote Internet accessed service? How many staff do you have dedicated to service sales? Provide an organizational chart of your construction department. 1.2 Construction Organization How many years experience does your local firm installing DDC System Technology? In the last five years only, in how many buildings has your firm installed DDC systems with a minimum of 200 hardware points per building. How many programmers do you currently have on staff? How many graphic developers do you currently have on staff? How many construction electricians do you have on staff on average? What are the terms of your standard product warranty? How many of your programmers also work in the construction department? How many of your graphics developers also work in the service department? Does your firm manufacture the DDC product it installs? Where is the DDC product manufactured? Where is the DDC product manufacturer s head office? Has your firm offered DDC products from manufacturers other than the manufacturer of your current product offering? How long has your firm installed the products from the manufacturer of your current DDC product offering? Where is your centre for advanced user training on DDC system programming and graphics production? Provide an organizational chart of your construction department. AJA rev0 Page 4

2 PROGRAMMING LANGUAGE A textual programming language is defined herein to be comprised solely of ASCII characters, numbers, decimals, mathematical operators, Boolean operators and hierarchal designations. A Block programming language is defined herein to be comprised or partially comprised of geometric shapes connected by lines to indicate calculations and program flow. 1. Describe the general form of the user programming language such as Textual or Block. 2. Briefly describe the programming environment that the City will use to create sequences of operation. 3. Provide a screen shot of the programming environment which will be used by the City. 4. Upon request - the submitter shall provide within 36 hours from request, a web link to a functioning programming environment to allow the City to evaluate all aspects of the programming language and the software development environment for up to a two week period. Provide Microsoft Remote Desktop access if the programming environment is not accessible through a Browser. 5. Describe where the TCL or BPL programming language is stored and executed in both the case of the BC and AAC. 6. Describe capabilities and limitations of performing calculations using variables and points from multiple panels connected by the network. 7. For TCL programming, describe how nested IF, THEN, ELSE statements are constructed. 8. Identify the location of your facilities where training in DDC sequence of operation programming, graphics production and system operation will be performed. 9. Identify licensing costs per seat for the programming language and environment. 10. Identify costs per seat for the BOWS software license. 11. Provide a soft copy of the programming language user s manual. 2.1 Example of TCL or BPL 1. Provide the Textural Control Language (TCL) or Block Programming Language (BPL) code example with your submission to carry out the example strategy. Provide this example code for each panel programming language and identify which panel model numbers use which language example. Demonstrate precisely how the Control Language would be utilised to implement the following strategy: Calculate the Minimum Weighted Temperature (MWT) by measuring 24 space temperature ST1 to ST24. Discard the four lowest space temperatures. Take the 5th lowest space temperature (STL5). Take the average of the balance of the 19 space temperatures sensors and multiply it by 0.66 (STLAVG). Calculate MWT by adding 33% of STL5 and 66% STLAVG. AJA rev0 Page 5

If real time (RT)is between 8:00 AM and 4:00 PM and minimum weighted space temperature (MWT) is more than 4 Deg C below the building objective temperature (BOT) then start Pump #1 (P1) As soon as Pump #1 has been on for 10 minutes, turn on the boiler (B1) If the day of year is before July 2, then factor A is equal to 1667 - (July 2 - day of year)/1368, otherwise the factor A is equal to 1661 - (day of year - July 2)/136 If the real time is greater than (8:00 AM minus a variable) times the difference between setpoint and space temperature, and if the real time is less than 3:30 PM and if outside air temperature is less than 10 Deg C, then enable boiler. 3 BACNET COMPLIANCE 1. Identify which of the BACnet Device Profiles are provided by the manufacturer of the proposed DDC system. 3.1 DDC Panels and Network 1. Submit technical specifications for all Building Controllers (B-BC), Advanced Application Controllers (B-AAC), Application Specific Controllers (B-ASC), Operator Workstations (B-OWS), Advanced Operator Workstations (AWS), Operator Display (B- OD) and other BTL Listed products offered by the manufacture of the proposed DDC system. 2. Include BACnet Protocol Implementation Conformance Statements (PICS) per Annex A of ANSI/ASHRAE Standard 135 for all proposed components. 3.2 BACnet Intra-System Communication 1. Describe if and how gateways are implemented in a typical network structure. 2. Describe BACnet protocols implemented over Ethernet for each Device Profile offered. 3. Describe any limitations to functionality such as graphics editing, and sequence of operation programming that are imposed when using the browser interface. 4. Provide a sample Network Architecture drawing that shows vendors complying panel types, model numbers, network connection, network speed and protocol and sample point count. 3.3 Building Controllers (BC) 1. Verify that the proposed B-BC conforms to BACnet Building Controller (B-BC) device profile as specified in ANSI/ASHRAE 135, BACnet Annex L and is listed as a certified B-BC in the BACnet Testing Laboratories (BTL) Product Listing. AJA rev0 Page 6

2. Describe where B-BCs would typically be applied. 3.4 Advanced Application Controllers (AAC) 1. Verify that the proposed B-AAC conforms to BACnet Advanced Application Controller (B-AAC) device profile as specified in ANSI/ASHRAE 135, BACnet Annex L and is listed as a certified B-AAC in the BACnet Testing Laboratories (BTL) Product Listing. 2. Describe where B-AACs would typically be applied. 3.5 Field devices and Smart sensors and Actuators 1. Provide technical specifications for input and output field devices generally installed with the proposed system. 3.6 Operator Workstation 1. Provide technical literature on the operator workstation. 2. Provide PICS for the proposed B-OWS, B-AWS and/or B-OD for the proposed system. 3. Identify which web browsers are supported for full functionality of the design. 4. Identify any Flash, Multimedia or third party plug-ins, or software dependencies required for the full functionality of the browser interface. 4 TREND LOGS AND GRAPHS In reference to B-AACs: 1. Identify the minimum interval that timed trend logs can be performed (e.g. 15 seconds between samples). 2. Identify how many samples can be stored locally on the AAC for each trend log. 3. Identify how many trend logs can be created on each model of AAC. In reference to B-BCs 4. Identify the minimum interval that timed trend logs can be performed (e.g. 15 seconds between samples). 5. Identify how many samples can be stored locally on the BC for each trend log. 6. Identify how many trend logs can be created on each model of BC. The sample frequency and number of samples identified must assume that 1 (one) trend log has been implemented for each input and output. 7. Provide a description on the features and usage of your historical data trend logging tool. 8. Describe which formats the data can be exported in. 9. Describe how historical data is stored and which query protocols are supported. AJA rev0 Page 7

5 SCHEDULING ALARM PROCESSING RUN ANALYSIS 1. Describe how normal schedules, annual holiday schedules and temporary schedules are implemented and how they are used. 2. Describe options on how alarms are can be filtered, processed and distributed. 3. Provide a screen shot of a run time totalizer showing start and stop times, durations and any other features. 6 F.D.D. AND DATA ANALYTICS The City seeks to improve energy efficiency and reduce operating costs by implementing automated measures to identify mechanical system operational faults. Examples of a Fault Detection and Diagnostics (FDD) implementation may include for example: identifying air handler operation that has not taken full advantage of free cooling identifying excessive equipment runtime beyond present daily and weekly limits Valve leak-by Damper operational fault Oscillating Control Loop Setpoint out of threshold range Statistical control accuracy index for terminal equipment 6.1 Data Analysis Language To carry out the various required analyses a Data Analysis Language is required. 1. Provide information on the language and programming environment for constructions rules for analyzing system operation. 2. Identify the manufacturer of the Data Analytics hardware and software. 3. Describe how the system may allow queries to be performed to facilitate data analysis without the need for manual data normalization, manual interpolation to compensate for missing samples, different sample frequencies or different sample timing. 4. Describe how date and time formats are handled when exporting to Excel. AJA rev0 Page 8

6.1.1 SAMPLE ANALYSIS 1. Provide screen shots of the symbolic or textual language and programming environment to implement the following analysis: Use the following Data Inputs: Outdoor air temperature (OAT) Average Perimeter Space Temperature (STPAVG) Air handler electrical current (SFAMPS) Perform the Following Bin Analysis Create OAT bin of 3 C starting at minus 3.0C to 30C Create Time of Day bins of one hour with 24 per day Take Average of operating fan current for each cross section of OAT and hourly bins. Segregate Tuesday to Friday, Saturday, Sunday, and Monday into four groups. Prepare the Following Analysis Output or Similar Provide a graphical report showing average operating fan current by hour of day during Tuesdays to Fridays for each of the 27 OAT bins. Provide a family of line graphs with hourly bins on the abscissa and average amps on the ordinate. Each line graph is for an outdoor temperature bin. AJA rev0 Page 9

APPENDIX FORMS FOR PART 1 AJA rev0 Page 10

6.2 Service Organization Form Number of mechanical service trucks in Metro Vancouver. Number of DDC controls service trucks in Metro Vancouver. Total number of service trucks in Metro Vancouver. Name and telephone number of Controls Service Manager. How are normal service requests handled? Where is service dispatch office located? How are after hours service requests handled? Where is after hours service dispatch office located? What is the service rate for DDC controls service during normal hours? What is the service rate for DDC controls service for after hours? What is your usual on site response time during normal hours? What is your usual on site response time for after hours? What is your hourly charge for remote Internet accessed service? How many staff do you have dedicated to service sales? Provide an organizational chart of your construction department. Provide separate sheet AJA rev0 Page 11

6.3 Construction Organization Form How many years experience does your local firm installing DDC System Technology? In the last five years only, in how many buildings has your firm installed DDC systems with a minimum of 200 hardware points per building. How many programmers do you currently have on staff? How many graphic developers do you currently have on staff? How many construction electricians do you have on staff on average? What are the terms of your standard product warranty? How many of your programmers also work in the construction department? How many of your graphics developers also work in the service department? Does your firm manufacture the DDC product it installs? Where is the DDC product manufactured? Where is the DDC product manufacturer s head office? Has your firm offered DDC products from manufacturers other than the manufacturer of your current product offering? How long has your firm installed the products from the manufacturer of your current DDC product offering? Where is your centre for advanced user training on DDC system programming and graphics production? Provide an organizational chart of your construction department. Separate sheet AJA rev0 Page 12