Power Supply SNMP Interface User Manual for SRL versions



Similar documents
SNMP-1 Configuration Guide

SNMP Manager User s Manual

Chapter 4 Management. Viewing the Activity Log

3.5 EXTERNAL NETWORK HDD. User s Manual

User s Manual Network Management Card

Firewall VPN Router. Quick Installation Guide M73-APO09-380

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

Network Management Card. User Manual

Chapter 3 Management. Remote Management

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module

Quick Installation Guide Network Management Card

Innovative Electronics for a Changing World INDEX

Multi-Homing Dual WAN Firewall Router

NMS300 Network Management System

Quick Installation Guide

User s Manual UPS SERIES. Network Interface Card UPS-IPCARD. I Rev B

SNMP Web Management. User s Manual For SNMP Web Card/Box

CYAN SECURE WEB APPLIANCE. User interface manual

Network Power Manager. User Manual

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

XMS Quick Start Guide

Olson Electronics Remote Power Monitoring Meter

SOFTWARE UTILITY OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES

2012 uptimedevices.com

3.5 LAN HDD Enclosure User s Manual

Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)

Connecting EWS using DDNS

User s Manual. Remote Management Card RMCARD202. Intelligent Remote Management Card allows a UPS system to be managed, monitored, and configured

Savvius Insight Initial Configuration

RPM Utility Software. User s Manual

SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

X Series Application Note 43:

How to Remotely Access Hikvision Devices User Manual

USER GUIDE. Web Interface

User s Manual. Remote Management Card

User Manual. Version Yeastar Technology Co., Ltd.

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version Rev.

sensorprobe2 / sensorprobe8/ sensorprobe8-x20 User Manual

3.5 Mobile LAN Disk. User Guide

Chapter 6 Using Network Monitoring Tools

DNS-312H Network Attached Storage

FMUX04 SNMP Tutorial

DSL-G604T Install Guides

- 1 - SmartStor Cloud Web Admin Manual

Manual Wireless Extender Setup Instructions. Before you start, there are two things you will need. 1. Laptop computer 2. Router s security key

(1) Network Camera

Network Video Recorder. Operation Manual

TN Using FileZilla FTP Server with a DT80 Series Logger

APPLICATION NOTE. CC5MPX Digital Camera and IPn3Gb Cellular Modem 10/14. App. Note Code: 3T-Z

SNMP Manager User s Manual

DRO-210i LOAD BALANCING ROUTER. Review Package Contents

Gigabyte Content Management System Console User s Guide. Version: 0.1

Connecting the DG-102S VoIP Gateway to your network

Using Internet or Windows Explorer to Upload Your Site

Chapter 6 Using Network Monitoring Tools

Document No. FO1001 Issue Date: Draft: Work Group: FibreOP Technical Team October 1, 2013 Final:

QNAP SYSTEMS INC. QNAP Digital Signage Player Web Console Manual

User Manual Network Interface

PRV-LX1 Importing Menu Backgrounds Importing Edit Decision Lists Importing Using a Network

How To Check If Your Router Is Working Properly

Technical Overview CM-2 Climate Monitor. Get yours direct at:

Application & Quick-Start Guide

Chapter 9 Monitoring System Performance

Chapter 1 Configuring Basic Connectivity

Quick Installation Guide DAP Wireless N 300 Access Point & Router

Chapter 1 Installing the Gateway

Demo of Data transferring (.CSV Files) from EGX300 to Our local PC/Laptop using- FTP

Technical Overview CM-16 Climate Monitor. Get yours direct at:

ViewPower Pro. User s Manual. Management Software for Uninterruptible Power Supply Systems

Configuring a customer owned router to function as a switch with Ultra TV

F453. TiF453. User guide 10/11-01 PC

Internet Telephony PBX system IPX-1980

Network Setup Guide. 1 Glossary. 2 Operation. 1.1 Static IP. 1.2 Point-to-Point Protocol over Ethernet (PPPoE)

Configuring Alarm s From The Field Logger DL1080/DL1081 Using SMTP2GO As The Outgoing Server

Manual. Teldat GmbH. Manual. Teldat Dime Manager. Copyright Version 1.3.5, 2012 Teldat GmbH

NETWORK SETUP GLOSSARY

Quick Installation Guide of WLAN Broadband Router

IP Camera (L series) User manual V1.1

H0/H2/H4 -ECOM100 DHCP & HTML Configuration. H0/H2/H4--ECOM100 DHCP Disabling DHCP and Assigning a Static IP Address Using HTML Configuration

RADAR NETWORK SETUP WITH WINDOWS XP/VISTA

Foglight Experience Monitor and Foglight Experience Viewer

Intelligent power sockets IQsocket tm IQSB-PicoIP. makes your life more comfortable. User guide. IQSB-PicoIP documentation v1.0 R1

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

How To Check If Your Router Is Working Properly On A Nr854T Router (Wnr854) On A Pc Or Mac) On Your Computer Or Ipad (Netbook) On An Ipad Or Ipa (Networking

3.5 Mobile LAN Disk User Guide

Protecting the Home Network (Firewall)

Type Message Description Probable Cause Suggested Action. Fan in the system is not functioning or room temperature

NEC Express5800 Series NEC ESMPRO AlertManager User's Guide

Quick Installation Guide DIR-620. Multifunction Wireless Router Supporting GSM, CDMA, WiMAX with Built-in 4-port Switch

Configuring the CyberData VoIP 4-Port Zone Controller with Audio Out

User s Manual. Management Software for ATS

NETVIGATOR Wireless Modem Setup Guide. (TG789Pvn)

If you need additional assistance please contact our Technical Support Center at 24 hours a day, 7 days a week.

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

Product Guide CM-Relay

Transcription:

Power Supply SNMP Interface User Manual for SRL versions SNMP-L User Manual 150722(firmware 02r_a12).doc

Table of Contents 1. INTRODUCTION... 3 1.1 Default IP Address... 3 2. LOGIN... 4 3. MONITORING & CONTROL... 5 3.1 CONTROL... 6 3.2 MONITORING... 6 3.3 THRESHOLDS... 6 4. NETWORK SETTINGS... 7 4.1 Disabling DHCP allocating a static IP address... 7 4.2 Enabling DHCP... 8 4.3 Changing Static IP from one to another... 8 5. PSU CONFIGURATION... 9 5.1 Understanding PSU Configuration Terms... 9 6. SNMP CONFIGURATION... 10 6.1 Understanding SNMP Configuration Terms:... 11 7. SYSLOG CONFIGURATION... 12 7.1 Understanding Syslog Configuration Terms:... 12 8. FIRMWARE UPGRADE & PASSWORD CHANGE... 13 8.1 Change Password... 13 9. INNOVATIVE ENERGIES CONTACT DETAILS... 14 2

1. INTRODUCTION Innovative Energies Ethernet enabled DC power supplies and No-Break DC UPS can be accessed via a network connection to provide accurate information for the monitoring of critical power systems. These models will have the suffix LAN+ in the model code. This user manual refers to units using SNMP protocol. 1.1 Default IP Address Unless specified otherwise at the time of ordering we set a static IP address of 192.168.2.10. The built in web server may also be set to DHCP enabled, in which case the network it is connected to will need to have a DHCP server to allocate an ip address to the unit. Refer to http://www.snmp.co.nz/ for further information. You will need to use some proprietary software, eg. Radmin http://www.advanced-ip-scanner.com/ to find the IP address allocated to the device. Using a web browser, eg. Internet Explorer, Firefox, Chrome, type the IP address into the url address box of the web browser, eg. 192.168.2.10. The following screen will appear: 3

2. LOGIN The default password is: iepassw1 (Note that the password is case sensitive) Insert the default password into the Password box. Note: The System Location field can be changed/personalised on the SNMP Configuration web page (see page 14). Click on Login with the mouse (Note that in some browsers pushing the Enter key to log-in may not work) 4

3. MONITORING & CONTROL 5

3.1 CONTROL Reset Temperature Log: Resets the temperature log. 3.2 MONITORING Power Supply Status: Good = Input voltage (mains) present Mains failure = No input voltage DC/Battery Status: Output Voltage: PSU Current: Temperature: Normal = DC output > V low Low = DC voltage at output < Vlow (PSU or battery, if connected) DC voltage at output (PSU or battery, if connected) Current supplied by PSU Temperature reading is taken from the temperature sensor which is normally placed near the batteries. If no temperature sensor is fitted the displayed value is N/A. Temperature Log Low: Displays the lowest temperature recorded Temperature Log High: Displays the highest temperature recorded 3.3 THRESHOLDS Threshold values can be set by the user according to their requirements. SNMP trap (alert) messages will be sent when one of the thresholds are exceeded. The units for the threshold fields are: Temperature High/Low: degrees C Over Voltage: PSU Current: Volts Amps 6

4. NETWORK SETTINGS This page enables the user to set a static IP address, eg. 192.168.2.10 or enable DHCP function. 4.1 Disabling DHCP allocating a static IP address To disable DHCP follow the steps below: (a) (b) (c) (d) (d) Set DHCP Client to Disable Type in the desired IP address eg.192.168.2.10 (this is the ex factory default unless otherwise specified at time of order) Remove DHCP and all preceding spaces from the Network Mask field. Leave the Gateway field blank. Click on the Submit button 7

4.2 Enabling DHCP To enable DHCP if your device has a static IP address: (a) (b) (c) Set DHCP Client to Enable Leave all other fields blank Click on the Submit button 4.3 Changing Static IP from one to another To change the IP if your device has a static IP address: (a) Type in the desired IP address eg.192.168.100.53 (b) Delete the gateway address (255.255.255.255) and leave it blank (c) Click on the Submit button 8

5. PSU CONFIGURATION This page displays the parameters programmed into the firmware of the power supply. These parameters are programmed in the factory and are not able to be changed by the user. 5.1 Understanding PSU Configuration Terms VLow: VHigh: Serial Number: PSU version: Voltage at which a DC Low alarm signal and SNMP trap are generated Voltage at which a DC High alarm signal and SNMP trap are generated Serial Number of the power supply Power supply revision version number 9

6. SNMP CONFIGURATION All fields are customisable and may be specified by the user to suit their specific applications. SNMP traps (alerts) can be monitored using a SNMP manager of the user s choice. The user may select which traps are set by changing the alarm trap mask code which is accessed by using a MIB Browser such as ireasoning MIB Browser. The default code for the alarm trap mask is set at 1048187. A new code may be calculated by using the excel spreadsheet available at http://www.innovative.co.nz/service/snmp, by clicking on ALARM MASK CALCULATOR. Simply insert 1 into the required yellow column to enable a trap or insert 0 into the required yellow column to disable a trap. MIB files are available by going to www.innovative.co.nz and clicking on Communication Enabled DC on the side menu bar. Alarm traps may be resent if a fault continues to persist. The resent time can be set by modifying the SNMP variable TrapPeriodicResentTimeinMinutes. The resent time range for resending traps is between 30minutes and 10079 minutes (7 days). If the user sets the range outside of these parameters, it will default to 1440 (24hours) which is also the factory default for a new device. Note: The new settings only take effect after performing a software reboot of the power supply web server. 10

6.1 Understanding SNMP Configuration Terms: SNMP Trap: An alert message that the user can enable or disable. Read/Write Community: Identifies groups and their set permission rights. The default setting for this is iepublic System Contact: System Name: System Description: System Location: Trap Destination IP: This is user specified and able to display names, phone numbers or email addresses This area is user specified This area is user specified This area is user specified Identifies where the alert message is to be sent. The user specifies the IP Address of the PC they want the SNMP traps (alerts) sent to SNMP Trap Port: Displays the port number of the SNMP trap (default is 162) SNMP Agent Port: Displays the port number of the SNMP agent (default is 161) 11

7. SYSLOG CONFIGURATION The Syslog is used for recording SNMP syslog messages. 7.1 Understanding Syslog Configuration Terms: Syslog: The syslog can be enabled or disabled Syslog Server IP: This displays the user specified IP address that is used for monitoring the Syslog data Syslog Port: This displays the port number of the PC setup to monitor the Syslog (default is 514) SYSLOG Update: This function refreshes all of the user specified data above 12

8. FIRMWARE UPGRADE & PASSWORD CHANGE This page is used to update the software to the latest version. This is done by using a standard FTP programme such as the Filezilla Client available at: www.filezilla-project.org. For detailed instructions on how to do this using Filezilla go to: http://innovative.co.nz/uploads/filezilla%20instructions.pdf Default settings are: User Name: root Password: iepassw1 The upgrade file is always named firmware.img and needs to be transferred to the /mnt/flash folder in the web server built into the power supply. Notes: 1. After completing the firmware upgrade the power supply will automatically reboot and you will need to log-in again. 2. As at 22 July 2015, the current firmware version is 02r_a12. 8.1 Change Password The default password is iepassw1 and may be updated by the user. Please note that there is no facility to reset a lost or forgotten password (as this would defeat the purpose of a password) and the unit will have to be returned to the factory for reprogramming. 13

9. INNOVATIVE ENERGIES CONTACT DETAILS At Innovative Energies we pride ourselves on being able to provide the best service to all of our customers. Our technical staff are always prepared to work with you to design, repair or solve any software related issues that may arise. We are located at: 1 Heremai Street, Henderson, Auckland, NZ Free phone: 0800 654 668 Phone: +64 9835 0700 Website: www.innovative.co.nz Email: info@innovative.co.nz 14