USB Input Tool Direct: USB-ITN



Similar documents
Measurement Data Input Unit USB Input Tool Series

Measurement Data Management

MeasurLink V7. Measurement Data Network System. MeasurLink provides total support from production line to production management and beyond.

Coolant Proof Micrometer QuantuMike

ABSOLUTE DIGIMATIC SCALE UNITS

InventoryControl for use with QuoteWerks Quick Start Guide

BULLETIN NO VISION

Coordinate Measuring Machines SCANPAK. Bulletin No Scanning module for evaluation of workpiece contours, and 3D digitizing of surfaces

MADRIX NEO Quick Start Guide & User Manual

Coordinate Measuring Machines CAT Bulletin No Computer Assisted Technology CAT-1000 Model Based Definition

New Products. U-WAVE Measurement Data Wireless Communication System U-WAVE-T U-WAVE-R

No.99MAM014B3 SERIES No.264

FREQUENTLY ASKED QUESTIONS (FAQs) 123Scan 2 Scanner Configuration Utility 19 April 2011

DUKANE Intelligent Assembly Solutions

HR-200/300/400/500 Series

Quality Management Software Page 15. Digimatic Mini Processor Page 20. Wireless Data Transmission Page 25. Digimatic Interface Page 27

Screen Capture. User s Guide. For ClassPad Series

PP8X Printer Driver Installation Instruction

UsbCom Standard / Professional Software

Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.

Yamaha 01V96 Version2 Upgrade Guide

USB 2.0 VGA ADAPTER USER MANUAL

Operating Instructions. Windows. Logo Transfer Software 2.0. Thank you for purchasing this Panasonic product.

Basic Specifications. Electrical. EPSON Perfection Color EPSON MatrixCCD TM line sensor. device Effective pixels

Installing the Gerber P2C Plotter USB Driver

Table of Contents Install a Printer Driver... 2 Print a Test Label... 9 Uninstall a Printer and Driver... 10

Omron Health Management Software Ver1.3 User s Help Manual

Imation LOCK User Manual

Quick Start Using DASYLab with your Measurement Computing USB device

AXIS 5810 A Bluetooth Print Plug. Quick Start

ScanShell.Net Install Guide

Phone: Fax: Web: info@ctiautomation.net

How To Connect A Port Replicator With An Ethernet To A Usb Port From A Usb Device

MiniPlex-41USB NMEA-0183 multiplexer Manual

DATA PROJECTOR XJ-A146/XJ-A246/XJ-A256

How To Use An Easymp Network Projector On A Computer Or Network Projection On A Network Or Network On A Pc Or Mac Or Ipnet On A Laptop Or Ipro Or Ipo On A Powerbook On A Microsoft Computer On A Mini

Windows 7/8. Installation Guide Sawgrass SG400 & SG800. v

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

FREQUENTLY ASKED QUESTIONS (FAQs) 123Scan 2 Scanner Configuration Utility

How To Use An Easymp Network Projection Software On A Projector On A Computer Or Computer

Acer LCD Monitor Driver Installation Guide

Scanner Set-up Quick Reference Card

DATA PROJECTOR XJ-A135/XJ-A145/XJ-A235/ XJ-A245

Be sure to connect the USB cable from TonePort into your computer s USB port, and then proceed with the following steps

How To Install A Scanner On A Computer With A Microsoft Scanner On Itunes Vista 2 (Windows) (Windows 2000) (Powerbook) (Macintosh) (Apple) (X86) (Ms7000) (Netbook

Network Setup Guide. Introduction. Setting up for use over LAN

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

OralChroma OralChroma DataManager

Laptop USB KVM Switch USER MANUAL CS661

EasyMP Monitor Operation Guide Ver.4.40

Getting Started. Image Scanner. Checking the Components P3PC EN

PRINTER DRIVER GUIDE (KODAK 305 Photo Printer)

Compressor Supreme Force Feedback User Manual

3.5in Black USB 2.0 IDE SATA External Hard Drive Enclosure

software MeasurLink is an easy-to-use, Windows-based family of quality data management software applications.

P3PC ENZ0. Troubleshooting. (installation)

EasyMP Network Projection Operation Guide

USB 2.0 Peripheral Switch USER MANUAL US221A / US421A

DSG SoftPhone & USB Phone Series User Guide

To get started, you will need the following items Product Key Router with firewall capability Network cables

Sabrent USB DSC5 USB 2.0 to SATA/IDE Hard Drive Adapter. 2.5 Notebook IDE Hard Drive

Operating Instructions Software (Fax Driver)

PCIe Gigabit Ethernet Card

BASLER ACE QUICK INSTALLATION GUIDE

ViewLinker USB 2.0 Graphics Adapter

e-dpp May 2013 Quick Installation Guide Microsoft Windows 2003 Server, XP, Vista, 7 Access Database

EasyMP Monitor Operation Guide Ver.4.53

Korosi Monitoring System (KMS) Software Manual

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

Section 5: Connecting the Laser to Your Computer

Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.

Motorola Phone Tools. Quick Start

USB 3.0 to HDMI External Multi Monitor Graphics Adapter with 3-Port USB Hub HDMI and USB 3.0 Mini Dock 1920x1200 / 1080p

EPSON Scan Server & EPSON TWAIN Pro Network

Chapter 2 Printing Printing Procedure...2-1

Music Data Management Software Data Manager 6.1 User s Guide

Guide to Installing BBL Crystal MIND on Windows 7

EasyMP Network Projection Operation Guide

System requirements. Usable microsd card. USB driver installation INSTRUCTIONS CLONING SOFTWARE CS-51

DiskPulse DISK CHANGE MONITOR

Panasonic Primary Colors Matching Support Software. Version 5.01

Installing S500 Power Monitor Software and LabVIEW Run-time Engine

C R E A T E D 8 / 2 1 / Recommended Settings for AVImark

Handheld LPC Utility Software for Windows. Operation Manual

User Guide USB 2.0 LAPTOP DOCKING STATION WITH VIDEO N2953

MASTER GUIDE (MAC) Gaming on the go is now possible.

Administrator Operations Guide

CITIZEN OPOS DRIVER 1.8 Setup Guide. 10/03/29 Rev 1.09

MFC6490CW Windows Network Connection Repair Instructions

SA-9600 Surface Area Software Manual

EPSON Perfection 2450 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. US letter or A4 size ( inches [ mm])

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

TR-3 Channel Editor. Software Manual

USB 3.0 to VGA External Multi Monitor Graphics Adapter with 3-Port USB Hub VGA and USB 3.0 Mini Dock 1920x1200 / 1080p

MULTIFUNCTIONAL DIGITAL SYSTEMS. Network Fax Guide

Internet and Computing Core Certification Guide Module A Computing Fundamentals

3.5 esata USB 2.0 to IDE SATA External Hard Drive Enclosure

Manual Software SPECTRO3-MONITORING V5.0

TrueAlarm Fire Alarm Systems

Transcription:

Small Tool Instruments and Data Management Measurement Data Input Unit US Input Tool Direct: US-ITN ulletin No. 2015 US Input Tool Direct now features a model dedicated to each instrument type and a software option for increased spreadsheet efficiency

US Input Tool Direct: US-ITN Our US Input Tool Direct has been streamlined into a range of dedicated models for each type of measuring instrument. Features 1: Using US-ITN lone In the same way as the existing model, IT-012U, measurement data can be input to Excel, Notepad, and other programs just by connecting the input tool to a computer. Data collection can start immediately after connecting the measuring instrument to a computer ecause the input tool is automatically recognized as an *HID keyboard device (a standard Windows driver) just by connecting it to a US port, no special software is required. Patent pending (Japan) *HID (Human Interface Device) Existing model: US input tool The values displayed on the measuring instrument can be sent to the computer just by pressing the data switch. US Input Tool Direct for micrometers: US-ITN- The input tool directly connects the measuring instrument to a US port on a computer This is the same result as that of typing numbers using the keyboard and then pressing Enter. The input tool has been streamlined by incorporating the US function into the cable Cable length: 0.9 m IT-012U No.264-012-10 + Cable length: 1 m No.05CZ662 Note on using a foot switch with US-ITN The US-ITPK and US-FSW options are required (see page opposite). If not using optional software the IT-012U input tool can be used with a foot switch. Measuring instrument with digimatic output C F The digimatic C plug is connected to the measuring D instrument. E F G Plugs US-ITN types Each type of US-ITN has a unique plug to fit the instrument it is designed for (figures to G on the left). Just select the type that fits your measuring instrument (US- ITN-, US-ITN-,...). Detailed specifications, such as part numbers, are shown on page 5. Cable length: 2 m The US plug is connected to a computer. Connection port US connector ( type) Computer Supported operating systems: Windows 2000 SP4 Windows XP SP2 or later Windows Vista Windows 7 2

Features 2: Using US-ITN in Combination with the Optional Spreadsheet Software lthough measurement data can be simply loaded directly into an Excel spreadsheet by connecting the instrument and input tool to a computer, using the optional US-ITPK software enables timesaving operations and procedures that significantly improve reliability and efficiency. Measurement data collection software: US-ITPK Order No. 06DV386 This setup and data collection software is used to input data from one or more measuring instruments (connected by way of US- ITN) to any Excel sheet. (This software package cannot be used with IT-012U.) Major features US-ITPK US dongle Details about the usage environment are provided on page 5. Software use requires US dongle. Excel input settings: The input destination (a workbook, sheet, or cell), cell-fill direction (right or down), cell-fill interval, and other settings can be specified. Measurement method selection: ny of the following three methods can be selected: Sequential measurement, batch measurement, or individual measurement. (For details, see the measurement examples.) Data input control: Data can be requested, canceled, or skipped by using mouse buttons, function keys, or foot switch. Character string input by the US foot switch adapter, US-FSW: ny previously specified character string can be input using the foot switch. Examples: pass or fail Number of units that can be connected (total number for both US-ITN and US-FSW): Up to 20 units can be connected for Windows Vista or Windows 7, and up to 100 units can be connected for Windows 2000 or Windows XP. However, the above numbers might be less depending on the system configuration. Data importation time: bout 0.2 to 0.3 seconds per unit. However, this value differs depending on the connected measuring instruments and measurement environment. Driver software: The VCP (virtual COM port) drivers for US-ITN and US-FSW are individually recognized using a built-in COM number. Patent pending (Japan) Various measurement patterns are supported by the three measurement modes of US-ITPK. Data input and cancellation can also be performed with a single button press using the foot switch. n US-ITPK measurement examples Sequential For this measurement method, one or more measuring instruments (connected by way of US-ITN) are measurement used to sequentially input one data item at a time according to a procedure stored in advance. Measurement example Sequentially measuring the external diameters X and Y and length H, shown in the figure at the right, of five workpieces at a time, and then visually judging whether the external appearance is acceptable (based on damage, discoloration, and other problems) X 1 micrometer is used to measure the external diameters X and Y of five workpieces. Y US-ITN- 2 caliper is used to measure the length H of five workpieces. US-ITN-C 3 The workpieces are visually examined for problems such as damage and discoloration, and then OK or NG (not okay) is input. Input character string: OK Input character string: NG These types of measurement are made possible by using the US-ITPK optional software While executing a measurement procedure, the following window is displayed, and Data Request*, Data Cancellation*, Data Skip*, Pause, or Stop can be selected by using the mouse. Operations marked with * can be assigned to a function key or foot switch (by way of US-FSW). H Commercially available US hub C D E F 1 Setting 1 2 3 4 5 Four US-FSWs + four foot switches 2 Dimension X 10.025 10.033 9.964 10.031 10.046 3 Dimension Y 9.982 10.017 10.008 9.996 10.027 4 Dimension H 29.97 30.02 30.07 29.96 30.04 5 External Data Data appearance OK OK NG request cancellation Cell-fill direction after inputting data (down or right) Carriage return (row, column) ny previously specified Excel sheet Micrometer input range (2 to F3) Caliper input range (4 to F4) Visual judgment input range (5 to F5) The cell into which the next data item will be input is shaded in green. US foot switch adapter: US-FSW No.06DV384 Total length: 160 mm Major specifications The foot switch function can be specified with US-ITPK and used accordingly. 1 Data control: Data Request, Data Cancellation, and Data Skip 2 Inputting any character string: Examples - pass, fail, OK, NG 3

atch measurement For this measurement method, data is imported in batches from multiple measuring instruments (connected by way of US-ITN). Measurement example Measuring the height of a workpiece at the four positions to D in batches (at the same time) as shown in the figure below Four US-ITN-Fs Commercially available US hub External appearance of US-FSW Foot switch (Optional) No.937179T (Cable length: 2m) C D E 1 Height Height Height C Height D 2 1 5.02 8.03 9.96 6.03 3 2 4.98 8.02 10.01 5.99 4 3 4.97 8.04 10.07 5.96 5 4 6 5 First measurement (complete) Second measurement (complete) Third measurement (complete) Fourth measurement (awaiting the next input) Height C D Data Data request cancellation Individual measurement For this measurement method, multiple operators make random measurements, and then data is input from the corresponding measuring instruments (by way of US-ITN) according to individually specified input procedures. Patent pending (Japan) Measurement example Dividing six workpieces into two groups of three, one of which is measured by each of two operators (parallel work) Commercially available US hub C ecause multiple operators are making measurements in parallel, the operation buttons in the following window and function keys, of which the system has only one, cannot be used. Only foot switches, for which multiple measuring instruments can be used, are available (by way of US-FSW). Operator 1 US-ITN-C Workpieces 1 to 3 Data Data Data Data request cancellation request cancellation Workpieces 4 to 6 Four US-FSWs + four foot switches Operator 2 US-ITN-C C D E F G 1 Setting 1 2 3 4 5 6 2 3 4 Dimension Dimension Dimension C 10.02 10.03 9.96 10.15 10.23 10.04 9.98 10.01 10.07 9.99 9.78 10.15 10.14 9.96 10.27 Operator 1 Operator 2 Next cell into which to input a measurement Next cell into which to input a measurement Notes on using US-ITPK Do not merge the cells within the range of cells specified as input destinations for measurement data. During measurement, do not perform operations on the Excel sheet you are using other than data input work stored in the measurement procedure. To write data, the measurement Pause or Stop button must be clicked. 4

n Major specifications of US Input Tool Direct Output specifications: US 2.0 or 1.1 Communication speed: 12 Mbps (full speed) Power supply: US bus power Mass: 59 g US 2.0 certification obtained Complies with the EU EMC Directive Illustration (Example: US-ITN-) Note: It is recommended to use a commercially available US hub that has US certification. 2m US connector ( plug) n US-ITPK usage environment Supported operating systems* Windows 2000 SP4, Windows XP SP2 or later, Windows Vista, and Windows 7 Supported Excel versions Excel 2000, 2002, 2003, and 2007 Hard disk t least 20 M of free space (required for installation) CD-ROM drive Required for installation US ports t least two ports (for the US dongle and US-ITN) t least 800 x 600 pixels, and at least 256 displayable Resolution colors * 64-bit operating systems are not supported. The natural language selected in US-ITPK must be the same as that used in the operating system. n Codes for the main measuring instruments classified according to the US Input Tool Direct code, part number, and plug type Determine the plug type suitable for your measuring instrument (one of the seven types from to G) in the following table, and then select the corresponding US Input Tool Direct. Model US-ITN- US-ITN- US-ITN-C US-ITN-D US-ITN-E US-ITN-F US-ITN-G Order No. 06DV380 06DV380 06DV380C 06DV380D 06DV380E 06DV380F 06DV380G Whether the existence of a data switch affects usability Cable type Illustration of the plug that connects to the measuring instrument Incorporates a data switch, so the tool is usable regardless of whether or not the measuring instrument has a switch. Water-proof with switch Data Switch Does not incorporate a data switch, so an instrument fitted with a switch is required in order to use the instrument alone. (However, the tool can be used with US-ITPK.) Water-proof with switch C With switch D 10-pin plain E 6-pin round F Straight type G Water-proof straight type Data switch Data switch Socket type on the measuring instrument Codes of major compatible measuring instruments [Digimatic Caliper /Super Caliper] -500 series CD67-S_PM CD-PMX/PM/GM -550/551 series CDC-P_PMX CDN-P_PMX [Digimatic Carbon Fiber Caliper] -552 series CFC-G/GL/GC/GU [Digimatic Depth Gage] -571 series VDS-PMX [Digimatic Scale Unit] -572 series SD-G [Digimatic Exclusive Caliper] -573 series NTD-PMX/PM [Digimatic Micrometer, QuantuMike] -293series MDC-MJ/MJ/MJT MDE-MJ [Tubular Inside Micrometer] -337 series IMZ-MJ -339 series IMJ-MJ [Digimatic Micrometer Head] -350 series MHN-M/MJ/MJN [Digimatic Exclusive Micrometer] (The end of the mark is MJ/MJ/M/M/PM/PM [Digimatic Holtest] -468 series HTD-R [Digimatic Micrometer Head] -164 series MHD-M [Digimatic Caliper] -500 series CD-CX/C/S_C - 550/ 551 CDC-C/CX, CDN-C/CX [Digimatic Depth Gage] -571 series VDS-DCX/DC [Digimatic Scale Unit] -572 series SD-D/SDV-D [Digimatic Exclusive Caliper] -573 series The end of the mark is -CX/C [Surface Roughness Tester] -178 series SJ-201/210/301/ 400/500 [Coating Thickness Gage] -179 series DGE-745/755 [Linear Height] -518 series QMH-S [Reference Gage] -515 series HMD-C ID-H [Laser Scan Micrometer] -544 series LSM-9506/6100/ 6200/6900 [μ-checker] Digital μ-checker (Using the foot switch) ID-F [Linear Gage/Counter] -542 series EF-PRH/ZR, EH-P/Z/S/D E-P/Z/D EC-D [Litematic] -318 series VL-/S/H Measuring instrument models that incorporate a data switch [Digimatic Micrometer] [Digimatic Height Gage] -121 series -192/570/574 series D HDM-/X, HD-/X -164 series HDS-H_C/C MHD-M HDF-N -227 series [Digimatic Caliper] CLM -500/550/551 series -293 series CD/CDC/CDN MDQ-M [Digimatic ore Gage] MDC-M -511 series [Tubular Inside Micrometer] CG-D -337 series IMZ-M -543 seires [Tubular Inside Micrometer] ID-C_X/_R/_G -339 series IMJ-M [Digimatic Depth Gage/ [Digimatic Holtest] Digimatic Thickness Gage] -468 series -547 series HTD Digimatic model (ID-CX) [Reference Gage] [Digimatic Carbon Fiber Caliper] -515 series -552 series HME-DM CFC-P/-L/-C/-U [orematic] [Digimatic Scale Unit] -568 series -572 series SM-C SD-E, SDV-E [Hardness Testing Machines] SD-F, SDV-F -810 series [Portable Hardness HM-100/200 Testing Instruments] HV-100/HH-411-811 series HR-500 HH-300 Measuring instrument models that do not have a data switch No corresponding models ID-C/S/C_ [Digimatic Depth Gage/ Digimatic Thickness Gage] -547 series Digimatic model (ID-C) -575 series ID-U ID-N ID- No corresponding models 5

Export permission by the Japanese government may be required for exporting our products according to the Foreign Exchange and Foreign Trade Law. Please consult our sales office near you before you export our products or you offer technical information to a nonresident. One Number to Serve You etter 1-888-MITUTOYO (1-888-648-8869) Note: ll information regarding our products, and in particular the illustrations, drawings, dimensional and performance data contained in this printed matter as well as other technical data are to be regarded as approximate average values. We therefore reserve the right to make changes to the corresponding designs. The stated standards, similar technical regulations, descriptions and illustrations of the products were valid at the time of printing. In addition, the latest applicable version of our General Trading Conditions will apply. Only quotations submitted by ourselves may be regarded as definitive. Mitutoyo products are subject to US Export dministration Regulations (ER). Re-export or relocation of Mitutoyo products may require prior approval by an appropriate governing authority. Trademarks and Registrations Designations used by companies to distinguish their products are often claimed as trademarks. In all instances where Mitutoyo merica Corporation is aware of a claim, the product names appear in initial capital or all capital letters. The appropriate companies should be contacted for more complete trademark and registration information. We reserve the right to change specifications and prices without notice. urora, Illinois (Corporate Headquarters) Westford, Massachusetts Huntersville, North Carolina Mitutoyo Mason, OhioCorporation 20-1, Plymouth, Sakado Michigan 1-Chome, Takatsu-ku, City of Industry, Kawasaki-shi, California Kanagawa 213-8533, Japan T +81 (0) 44 813-8230 F +81 (0) 44 813-8231 http://www.mitutoyo.co.jp Note: ll information regarding our products, and in particular the illustrations, drawings, dimensional and performance data contained in this pamphlet, as well as other 2010 Mitutoyo merica Corporation, urora IL 1110-07 Printed in US December 2010 technical data are to be regarded as approximate average values. We therefore reserve the right to make changes to the corresponding designs, dimensions and weights. The stated standards, similar technical regulations, descriptions and illustrations of the products were valid at the time of printing. Only quotations submitted by ourselves may be regarded as definitive.