User manual LCD 240-2xx



Similar documents
User manual LCD 240 Configurator

LCD240X128A Asansörler İçin Grafik LCD Gösterge Graphic LCD Display for Elevators

FLOOR INDICATORS CATALOGUE

FLOOR INDICATORS CATALOGUE 2007

FLOOR INDICATORS CATALOGUE 2007

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16400(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JAN.19,2000 TOTAL PAGE : 7 APPROVED BY:

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS (LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : DEC.01,1999 TOTAL PAGE : 7 APPROVED BY:

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16290(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JUL.03,2001 TOTAL PAGE : 7

UM0272 User manual. Central Unit for Alarm System (CUAS) Evaluation Board. Introduction

User Manual DMD Configurator

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Kit for TLM051 monitor

User Manual. Humidity-Temperature Chart Recorder. Model RH520

RS - SPM. Serial parallel translator module

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

HyperAccess Access Control System

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

Servo Info and Centering

AC-115 Compact Networked Single Door Controller. Installation and User Manual

BATRON DOCUMENT NUMBER AND REVISION VL-FS-BTHQ 21605VSS-02 REV.A (BTHQ 21605VSS-FSTF-LED05W(1 DIE)) Feb/2002 BTHQ FSTF-LED WHITE 1/15

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

GTS-4E Hardware User Manual. Version: V1.1.0 Date:

computer radio control system

PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version ( )

Vision OPLC. V R34/V350-J-R34 Technical Specifications. Technical Specifications

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

LIFT CONTROL SYSTEMS CATALOGUE 2007

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

DS1307ZN. 64 x 8 Serial Real-Time Clock

FOR MESSRS. : WC1602A PAGE: 1/12 CONTENTS

Innovative Electronics for a Changing World INDEX

NC-12 Modbus Application

EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

T0118 T2118 T3118. Instruction Manual

Name Description P/N. Programmer Programmer with calibration function SDD-AAPNP. Parameter Min. Typ. Max. Notes. (Vo+ - Vo-) - Voltage

-SFYLYHTC06 FOR MESSRS. :

3½ DIGIT VOLTMETER MODULE LED- / LCD- SERIES

7-SEGMENT DIGITAL CLOCK

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

LIFT CONTROL SYSTEMS CATALOGUE 2007

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

UniPi technical documentation REV 1.1

PK5500 v1.1 Installation Instructions

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

Bluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205]

Vicon Flash Upgrade Software

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

Technical description MX-1 VB Edge

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.

Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Microprocessor Home Security System


UniOP epad33 and epad33t

ICS379. Quad PLL with VCXO Quick Turn Clock. Description. Features. Block Diagram

NHD-0420D3Z-FL-GBW-V3

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units

USER MANUAL MODEL

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

ULC Technology: High-performance gate array package using multiple metal layer CMOS technology featuring sub-micron channel lengths (0.

RC2200DK Demonstration Kit User Manual

SYSTEM 4C. C R H Electronics Design

D45. SySTEm. ThE high-performance

SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

Time switch D21-1-channel / 32 / / 63 / General information. Overview. Set language

LCD MODULE DEM SYH-LY

V350-R34 V350J-R34. npn inputs pnp inputs

User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller M720

VIDEO DOOR PHONE SYSTEM

DK40 Datasheet & Hardware manual Version 2

LCD MODULE DEM B FGH-PW

VDPLAT1 ANIMATED RGB LED TILE USER MANUAL

SFP-TX 1000BASE-T SFP Transceiver 10/100/1000M SFP Transceiver

REGTRONIC OPERATING INSTRUCTIONS

7 OUT1 8 OUT2 9 OUT3 10 OUT4 11 OUT5 12 OUT6 13 OUT7 14 OUT8 15 OUT9 16 OUT10 17 OUT11 18 OUT12 19 OUT13 20 OUT14 21 OUT15 22 OUT16 OUT17 23 OUT18

Memcom Emergency Telephone

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Remote monitoring of Crouzet Millenium 3 Using Netbiter EasyConnect EC220 & Netbiter Argos

WEB log. Device connection plans

Inwall Room Temperature Unit

DS1621 Digital Thermometer and Thermostat

RC Camera Control. User Guide v /20/2012

MILE Encoder for EC 90 flat

TMS TANK MANAGEMENT SYSTEM

Three Channel Optical Incremental Encoder Modules Technical Data

KTA-223 Arduino Compatible Relay Controller

Web Site: Forums: forums.parallax.com Sales: Technical:

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

M1000 Process Alarm Monitor

Transcription:

Kapitelbezeichnung Kapitelbezeichnung X.X Unterpunkt User manual 2xx 2VS 2VP 2HS 2HSC 2HP 2HPC

Kapitelbezeichnung Kapitelbezeichnung X.X Unterpunkt Memo SCHAEFER GmbH Winterlinger Str. 4 72488 Sigmaringen Germany Phone +49 7571 722-0 Fax +49 7571 722-99 info@ws-schaefer.de www.ws-schaefer.de Support If you have any questions regarding this product please contact: Phone +49 7571 722-51 Fax +49 7571 722-99 2 Copyright Duplication (copy, print, microfilm or any other form) as well as electronic spreading of this document is only permitted after formal writting consent of SCHAEFER GmbH. SCHAEFER GmbH reserves the right to carry out alterations of technical details without prior notice. For all transactions our General Conditions of Sale and Delivery shall be applicable. All rights reserved. Ress. 012267 Revision: 2009-04-14 19

VEBUS A1 Parallel to serial converter 11.5 Function 11.6 Electrical adjustment 11.7 Size a. environment Index User manual 2xx 11.5 Function Device reads its parallel input every 100 ms. If there is a change in the parallel input, device immediately sends the serial control packet to V EBUS interface. Device also sends the serial control packet every 500 ms, if there are no changes in the parallel input. 10.6 Electrical adjustment Jumper J5 should be set tomatch the input signal polarity. When changing jumper position, first disconnect the device frompower supply, then change the jumper position and after that connect the device back to power supply. This is because the device automatically adapts to different input polarities by reading the jumper position tomemory when power is switched on. 10.7 Size and environment Size (+additional space for connectors) Physical dimensions: 95 mm x 65 mm x 18 mm Tolerances: ± 0,3 mm Operation environment Temperature: 0 70 C Dry environment, RH: < 85% (no condensation) Not to be used in wet, moist or dusty environment Index 1 Introduction... 4 2 Display items, symbols and fields... 4 3 Electrical connections... 5 4 Electrical adjustment... 6 5 Configuration... 6 6 Setup menu... 7 7 Assembly dimension... 8 8 Available versions of LCD240... 9 8.1 LCD 240 vertical series... 9 8.2 LCD 240 horizontal series... 9 9 Tecnical information... 10 9.1 Fuctional specifications... 10 9.2 Display module specifications... 10 9.3 Electrical connections... 11 9.4 Configuration... 11 10 Other devices wired in parallel... 12 11 VEBUS A1 - Parallel zu seriell Konverter... 14 11.1 Description... 14 11.2 Features... 14 11.3 System block diagramm... 15 11.4 Connection... 16 11.4.1 Electrical connections... 17 11.5 Function... 18 11.6 Electrical adjustment... 18 11.7 Size and environment... 18 18 3

Intorduction Display items, symbols and fields 2xx VEBUS A1 Parallel to serial converter 11.4 connection 1 Introduction Note Available features depend on urchased device version. All here described features are not available in all device versions. LCD240 is a graphic LCD display with a horizontal resolution of 128 by 240 and vertical resolution of 240 by 128 pixels. The display is optimized for lift applications. It can be assembled either to a car or to a level. It can present floor markings, direction arrows and other graphical symbols needed for special indications. Also other information, such as time and date, a company logo or floor info pictures, can be presented on specific versions. The user editable floor info pictures enable presentation of any useful information associated with certain floor(s) in addition to a regular car position indication. 2 Display items, symbols and fields Display is divided to four sub-areas. Names of these fields are as follows: Arrow/symbol field (48 x 96) Floor marking field (48 x 96) Logo field (12 floor info pictures only available for LCD 240 HXC) (160 x 32) Date and time field (only available for version HX) In normal situation an arrow is displayed in the arrow/symbol field and a floor marking is displayed in the floor marking field. Appearance of the arrows can be either automatic or externally controlled. Selection is made in the setup menu. When the external mode ( EXT ) is selected, appearance and direction of arrow is controlled by 2 inputs ARR-UP and ARR-DOWN (J2 / 13 14). Input B5/MOVE (J2 / 6) activates arrow scrolling. 11.4.1 Electrical adjustment Power supply input Operating voltage range, 12 30 VDC (max. 5% ripple voltage) Current consumption, 33 ma @ 24 VDC (no load) Parallel control interface (J1) Internal pull-down or pull-up resistors depending on jumper setting Jumper is set to match control signal polarity (optional) Pull-down/-up resistance: 10 k Input voltage range: 0 30 VDC - Power supply input: - Logic 0:0-1 VDC - Logic 1:10-30 VDC Symbol control inputs: 4 inputs for the symbol indications control 2 inputs for arrow direction control (ARR-UP, ARR-DOWN) 1 input for travelling signal VEBUS serial communication interface (optional) RS-485 compatible bus connections Protocol is develop and optimized for lift applications Speed: 38400 bps Feed through connector for supply voltage (J3), Max. load 3A 4 17

VEBUS A1 - Parallel zu serial converter 11.4 connection Electrical connections 2xx 11.4 connection 3 Electrical connections 95 85 OUTPUT Gnd V out B A When the automatic arrow function is selected ( AUTO ), the microcontroller continuously observes the car position status input. In case of any change it evaluates the direction of car movement and presents an arrow pointing to that direction. When the floor code stop changing, the arrow is blanked after 3 seconds. LCD240 is capable to present 4 different symbols. Their appearance is controlled by 4 symbol indication inputs (J2 / 7 10). In addition, the symbol number 4 can be configured to appear when the car is in a certain floor. Supply voltage (12V 24V DC) is applied to J1 connector. The device is controlled through a 14-pin connector (J2). The connector has: 5 inputs (J2 / 1 5) for the position status, 4 inputs (J2 / 7 10) for the symbol indications, 2 inputs (J2 / 13 14) for the direction arrows and 1 input (J2 / 6) that activates the arrow scrolling Refer to Electrical specifications for voltage levels and other details. V out GND OUTP Adr.0 65 55 Prog. UP PULL DOWN Symbols have priority: symbol number 3 overrides symbol number 4, symbol number 2 overrides symbols number 3 and 4, etc. Normally (and as factory default) symbol number 1 is used for fire alarm, 2 for overweight and 3 for service. Own symbols can be edited and downloaded by means of LCD240-2xx Configurator software. When any of the 4 symbols is displayed, it appears in the arrow/symbol field. Arrow and floor marking are both displayed in the floor marking field Optional floor info pictures appear always in the logo field and also optional date and time appear in the date and time field. 65 mm 55 mm V in Gnd INPUT 12... 30 V DC Adr.0 Adr.1 Adr.2 Adr.3 Adr.4 Adr.5/Fahrt Sondertext 1 Sondertext 2 Sondertext 3 Sondertext 4 Gong auf Gong ab Pfeil auf Pfeil ab J2 PARALLEL INPUT 16 V in Gnd INPUT 12-30 V DC 5

Electrical adjustment Configuration VEBUS A1 Parallel to serial converter 2xx 11.3 System block diagram 4 Electrical adjustment 5 Configuration 11.3 System block diagram LCD 240 Schacht LCD display contrast can be adjusted by trimming potentiometer R57. Default contrast setting is made in factory. Device can be configured in two different ways: By means of devices own setup menu or with LCD240-2xx Configurator PC-software. We recommend using LCD240-2xx Configurator software; it is easier and more illustrative. ^I 3 Programming must be enabled (ie. PROG ON), when programming the device with LCDtool. After programming, the mode has to be disabled (OFF). When programming mode is off, the pin connector is active. Emergency info picture parameter is used for selecting the picture to be shown in the center of the display when power failure occurs. There are three pictures available ^I 3 ^I 3 Kabine Two jumpers should be set to match the input signal polarity. J8 is for the position status inputs and J4 for the others. When changing the jumper positions, first disconnect the device from the power supply, then change the jumper positions and after that connect the device back to power supply. This is because the device automatically adapts to different input polarities by reading the jumper positions to memory when power is switched on. Spannungsversorgung / BUS 4 ^I 3 ^I 3 VEBUS A1 Dual/Gray Spannungsversorgung Aufzugssteuerung 6 15

VEBUS A1 - Parallel to serial converter 11.1 Description 11.2 Features Setup Menu 2xx 11 VEBUS A1 - Parallel to serial converter 11.1 Description VEBUS A1 is a general purpose converter card for different bus interfaces. It is intended for lift applications. It converts typical binary parallel control to RS-485 compatible serial control. 10.2 Features Intended for lift applications Maximum number of floors is 32 Converts parallel input to serial output (VEBUS) VEBUS is a RS-485 compatible serial interface designed for lift applications 6 Setup Menu With the aid of the setup menu the user can make changes to certain properties of the device. Three push buttons are assigned to browsing of the menu. Pressing the SET push button for at least 3 seconds activates the setup menu. If there are more than two possible values, FW steps to the next value and BW to the previous one. Value is stored by pressing the SET button. Text STORED is displayed and device returns to menu browsing mode. If browsing is paused (no key is pressed) for 10 seconds, device returns from setup menu to standard display mode. Setup Menu: Input coding (BIN/GRAY) Logo graphics (OFF/ON) Programming (PROG OFF/ON) Power Failure Polarity (PF POLAR 0/1) Arrow input selection (EXT/AUTO) Emergency info picture (EMER INFO 0 2) Floor marks (BUS 00 BUS 31) Time/Date Menu items are scrolled by buttons FW (forward) and BW (backward) and selected by SET button. When selected, pressing the FW button toggles between values. While editing floor marks there is one more step needed. Floor mark consists of up to two characters, so the first pressing of SET button makes first character editable by buttons FW and BW. Second pressing directs editing to second character and finally the value is stored by third pressing of the SET button like usually. 14 7

Assembly dimension Other devices wired in parallel 2xx 7 Assembly dimension 172 common cathode 147±0.1 137±0.1 Schweißbolzen M3 x 10 37 2(3) GND +UB signal lines (floors, direction,...) Schweißbolzen M3 x 8 + - 57 53±0.1 LCD 240-2 HP -2 HPC -2 VP or 120 43±0.1 63 VEBUS A1 63 59 ±0.1 uncoupling PCB 113 + - SYN42,SM84 DMD 8 13

Other devices wired in parallel Available versions of LCD 240 8.1 LCD 240 vertikal series 8.2 LCD 240 horizontal series 10 Other devices wired in parallel If other devices (e.g. SYN42, SM84; DMD) are wired in parallel to the LCD 240, an uncoupling PCB has to be inserted into the signal lines. common anode GND +UB signal lines (floors, direction,...) uncoupling PCB If more than 6 signal lines are used, a second uncoupling PCB is needed. + - LCD 240-2 HP -2 HPC -2 VP or VEBUS A1 8 Available versions of LCD 240 8.1 LCD 240 vertikal series Product name 2VS 2VP Description: Description Basic version with VEBUS interface Basic version with parallel connection LCD 240 basic version has three fields named as follows: Floor marking field (maximum 2 digits) Arrow/symbol field Logo field Emergency info automatic arrow programmable Gong X X X X X X X All programming can be made with the optional PCsoftware (LCD240-2xx Configurator). 8.2 LCD 240 horizontal series Product name 2HS 2HSC 2HP 2HPC Description: Description Basic version with VEBUS interface Extended version with VEBUS interface Basic version with parallel connection Extended version with parallel connection LCD 240 basic version has three fields named as follows: Emergency info Date and time Floor info pictures automatic arrow programmable Gong X X X X X X X X X X X X X X X X X X + - SYN42,SM84 DMD Floor marking field (maximum 2 digits) Arrow/symbol field Logo field LCD 240 extended version has additional: Date and time field The extended version can show floor pictures (advertisement, small Logo, small text (160x32)) in the Logo field. All programming can be made with the optional PC-software (LCD240-2xx Configurator). 12 9

Technical information 9.1 Functional specifications 9.2 Display module specifications Technical information 9.3 Electrical connections 9.4 Configuration 9 Technical infomation 9.1 Functional specifications 9.2 Display module specifications 9.3 Electrical connections 9.4 Configuration Available features depend on purchased device version. All here described features are not available in all device versions. Intended for lift applications Applicable for assembly either to the car or to a level. Maximum number of floors is 32 Presents floor markings, direction arrows and graphical symbols needed for special indications Two different ways to control the arrows External input signals for arrow direction control (EXT) Automatic appearance of arrow when position input changes (AUTO) Floor mark consists of one or two letters or numbers (0...9, A...Z, minus sign) (Optional) presentation of time and date (Optional) presentation of floor associated bitmaps of size 160 x 32 pixels, capacity is 12 bitmaps Ability to display emergency information in a power failure situation automatically (requires external back-up power supplied to corresponding connector). Polarity is software selectable. Real time clock operates until year 2099 (V) Automatic daylight saving time change (V) Display resolution: 240 x 128 pixels / 128 x 240 pixel(h x V)) LCD type: STN, negative, blue, transmissive Backlight: long life white LED Active area: 114 mm x 64 mm / 64mm x 114mm Viewing angle: min. 40 (with contrast ratio = 1.4) Contrast ratio: typ. 5 (when _ = 10 and _ = 0 ) Adjustable contrast (trimmer potentiometer) Expected lifetime 100 000 h Power supply input Operating voltage range, 12 30 VDC (max. 5% ripple voltage) Current consumption, 65 113 ma @ 24 VDC (without gong) Backup battery input, min. 12 VDC (see emergency light documentation) Control interface (J2) Internal pull-down or pull-up resistors depending on jumper settings Jumpers are set to match control signal polarity. Two jumpers to individually set polarity for parallel position status Pull-down/-up resistance: 10 k Input voltage range: 0 30 VDC: Logic 0: 0...1 VDC Logic 1: 10...30 VDC Maximum input current: ±3mA (depending on input polarity) Parallel mode position input coding is selectable: Binary/Gray Symbol control inputs: 4 inputs for the symbol indications control 2 inputs for the Gongs control (Gong up, Gong down) 2 inputs for arrow direction control (arrow up, arrow down) 1 input that activates arrow scrolling (move) Programming interface RS-232 serial interface for LCDtool cable VEBUS serial communication interface (optional) RS-485 compatible bus connections Protocol is developed and optimized for lift applications Speed: 38400 bps Setup menu Device configuration is made by means of displayed menu and 3 push buttons Covers configuration of: Input coding (BIN or GRAY) Installation position selection (CAN/LANDING) Logo graphics (LOGO OFF/ON) Programming (PROG OFF/ON)) Power Failure Polarity (PF POLAR 0/1) Arrow input selection (EXT/AUTO) Emergency info picture (EMER INFO 0-2) Time and date settings (RTC SET) (optional) Floor marks (BUS 00 BUS 31) 10 11