ENVIRONMENTAL TESTING SERVICES. Product and component performance verification



Similar documents
ENVIRONMENTAL TESTING

How To Make A Lightweight Car

Shock and Vibration Testing

VIPAC ENGINEERS & SCIENTISTS

Sebert Group Structure Sebert Schwingungstechnik GmbH

HELLA MEANS QUALITY EXCELLENCE SINCE 1899

Studies on the Effect of Ageing on a range of UK Polymer Bonded Explosives

Espotel Test Laboratory Services. November 20, 2014

ISO/IEC Environmental Test Laboratory

Automotive Application Questionnaire for Electronic Control Units and Sensors. Electronic Components and Systems

CNG & Hydrogen Tank Safety, R&D, and Testing

White Paper IK code: Impact protection in line with the IEC standard. By Sven Schnautz

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Technical application guide IP codes in accordance with IEC 60529

VI Chip Environmental Qualification Testing Standards

ETSI EN V2.1.2 ( )

Solar energy Solar technology in endurance testing

Subtropical Cities September Design for Energy Efficiency in Commercial Buildings in Queensland

Low VOC Performance Protection Systems

Focus on Building Louvres. Sun shading & comfort ventilation.

Physically Crosslinked Foam Insulation

New Cable Tie Type Classifications

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

Engineering & Testing Services. Hydraulic Fitting Design and Hydro-Mechanical Testing

Lithium Ion Battery Specifications

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Secure Data Drive Safe storage of sensitive data in harsh environments

Aerospace and Defence

Your gateway to international certification

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

CSZ s EZ-View Software

Dew-Point Measurement Solutions

WERRIS CREEK COAL PRP U1: MONITORING RESULTS WHEEL GENERATED DUST

Frost Damage of Roof Tiles in Relatively Warm Areas in Japan

Elite x vs. Surface Pro 4 Performance Test

HyLife TM HVAC Line Corrosion testing. Precision Tubing Technology Centre, 2012

Accelerated Acid Etch for Automotive Clearcoats I

USER S MANUAL HSC-24A

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

PWM-90 series IP67 TRC ELECTRONICS, INC Mean Well PWM-90 Series

Test Report No. C829QPEN

TIG INVERTER INSTRUCTION MANUAL

DC/DC CONVERTER Environmental Test Report

Problem / Solution. The problem:

Electronic Concepts & Engineering, Inc. Developers of Electronic Systems & Software. Military & Aerospace

Trakya Cam Sanayii A.Ş. Adres: İş Kuleleri Kule Levent- İSTANBUL/TÜRKİYE 07 EN

Securing your electrical installations Prisma,

Acoustic design of schools: performance standards. From 2003 to 2014: a brief guide to the changes in BB 93. by Jack Harvie-Clark, 9th January 2015

TRANSPORT OF DANGEROUS GOODS

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

White Paper Product Quality Fujitsu ESPRIMO PCs, Fujitsu CELSIUS workstations, Fujitsu FUTRO thin clients

CERTIFICACIONES Y PRUEBAS DE LABORATORIO

Experience. The Atlas Difference.

How To Use A Power Supply Unit (Upu)

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

DENSO WATERPROOFING SYSTEMS

The purpose of industrial lighting is to enable quick and accurate work, safely, and in a good visual environment. Points of note are:

ENVIRONMENTAL TEST SPECIFICA- TION FOR INSTRUMENTATION AND AUTOMATION EQUIPMENT

Solving the Problem of Motor Protection from Moisture, Water and Dust in Commercial Refrigerators.

Bearing designs. Bearing testing. Extract from the Railway technical handbook, volume 1, chapter 4, page 99 to 105

PRODUCT DATASHEET. Confidex Ironside Micro CONTENTS

CHARGING STATIONS FOR ELECTRIC VEHICLES QUICK CHARGER

Oil-Free Screw Compressors. Water-injected Technology. Rely on GD to provide the perfect fit

PCB Relays Twin Relays

The built environment : a policy framework for climate adaptation

User s Manual AURORA 1.2K/2.2K

AGING CHARACTERISTICS OF NUCLEAR PLANT RTDS AND PRESSURE TRANSMITTERS

PQS performance specification

UN Manual of Tests and Criteria, Sub-section 38.3, Amendments to the 5 th edition, effective 2014 January 1 st

Design qualification and type approval of PV modules

3. ELECTRICAL PERFORMANCE PROPERTY TEST CONDITION PERFORMANCE 3. 1 Contact Resistance 1) Center Push 100mΩ Max

AIR-CONDITIONER SPLIT TYPE

Advanced Systems Tester 900AST

ENVIRONMENTAL EFFECTS ON COATINGS

How To Use The Vacon 0 Machinery

Alfa Laval Abatigo. Redefining adiabatic cooling

PWM-60 series IP67 TRC ELECTRONICS, INC

Eurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice

Redundancy Module QUINT-DIODE/40

PRODUCT SPECIFICATION

Heading FACT SHEET. Overview.

Würth Elektronik ibe Automotive solutions

Climate chamber with illumination

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

Compliance Test Results. of Independently Manufactured. Automotive Replacement Headlamps. To FMVSS 108. Study II. May 13, 2004

ELENCO PROVE ACCREDITATE - CATEGORIA: 0

DuroSite LED End-to-End Linear Fixture - NSF. for Indoor and Outdoor Industrial Applications

2KW CERAMIC HEATER DHCER20. User Manual

8146/5 Series Breaker Panelboards

Vibration Test for Large Lithium-ion Battery Assemblies on UN Transportation Manual of Tests & Criteria JARI

1. Introduction. 2. Components. 3. Optical Specifications. 4. Electric Specifications. 5. Dimension. 6. Operating Environment. 7.

ANSI Watthour Meter Testing & Certification Programs

READING DEVICE US-05

The entire document shall be read and understood before proceeding with a test. ISTA 3B Page 1 of 35

CLASSIFICATION NOTES

Technical. Specifications. fischer Rugged Flash Drive. New. Rugged Solution for Safe Data Storage in Harsh Environment

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

ETSI EN V3.0.1 ( )

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Series description: Wilo-Drain TC 40

Transcription:

ENVIRONMENTAL TESTING SERVICES Product and component performance verification

environmental testing State-of-the-art technology and increased demands for product and component reliability have intensified the need for advanced environmental testing. Vipac is a NATA accredited, ISO 17025 compliant, fully independent testing laboratory. Our Environmental Testing Centres of Excellence offer a broad range of vibration, pressure and climatic testing capabilities. We test to a wide range of international, industry and client specific standards and provide services to many market sectors including: Motor vehicle Automotive components Rail Aerospace electronic equipment Defence electronic equipment Medical devices Consumer and electronic devices (mobile phones, radio systems etc.) Industrial components (controllers, actuators, etc.) Packaging (pharmaceutical, food and beverage, consumer products etc.) Vipac offers a variety of test facilities for a broad range of testing requirements including: Vibration and shock testing Combined temperature and vibration testing Temperature and humidity testing Water and dust ingress protection testing Driving sand and dust testing Salt corrosion testing Solar irradiation testing Drop testing Hardness testing Flammability testing Chemical resistance and exposure testing Structural load testing Testing to client specific requirements. environmental testing services 3

environmental testing Accelerated life testing enables faults to be discovered in a short amount of time helping to minimise failures in the field and costly recalls. It also helps with prediction of service life and maintenance intervals. Vipac is contracted by many companies to provide confidential testing services to a wide range of standards including: Other Tests High intensity acoustic tests up to 145dB Explosive de-compression tests Rain and moisture leakage tests Salt fog test Sand and dust penetration tests to most customer s requirements and for any product small parts up to container size Bounce tests for packaging and transport of goods. As well as testing to industry and regulatory standards, our experience and capabilities are employed by clients to develop testing regimes as part of their product development cycle. Vehicle and automotive component tests can be carried out to automotive standards such as those of Ford, Holden, Mitsubishi and Toyota. 4 environmental testing services

facilities Vipac have extensive environmental testing facilities including: Environmental chambers Twelve climatic chambers Volume 0.25m 3 to 56m 3 Temperature ranges -64 C to +130 C Relative humidity 5% to 98% Dust, Water Ingress and Salt Spray environmental chambers Three altitude chambers Vibration Seven shakers from 8 to 60kN Up to 50mm displacement Shock Five shock machines up to 1200G 901D light weight and medium weight shock Mechanical Three mechanical fatigue testers up to 100kN Conditions can be controlled to tight tolerances in Vipac s environmental chambers: The Environmental Test Chamber, measuring 14m long x 5.5m wide and 4.5m high, is certified to test through a temperature range from -5 C to +60 C and humidity from 40% to 95%. It incorporates a 30 lamp CSI solar simulator, allowing any sunlight condition to above 1120W/m 2 to be reproduced. Diurnal cycling can also be conducted. The High Temperature Chamber (2.2m x 2m x 2m) provides for testing from ambient to 250 C. The Balanced Temperature and Humidity Chamber (3m x 3m x 3m) allows testing from 20% to 95% relative humidity and from -80 C to +150 C. The Thermal Shock Chamber allows testing from -80 C to +220 C Various smaller chambers covering dry heat, humidity and temperature shock cycling for testing smaller products or parts.

testing technical specifications Climatic Testing Temperature range Humidity range -65 C to +180 C 10 to 99% RH Test articles Various Chambers around 1m 3 Chambers measuring up to 6m x 4m x 3m available Protection Testing IP testing Rain testing Corrosion testing Mechanical impact IP11 to IP68 with up to 8m immersion To MIL 810G Salt spray & other corrosives, 2m x 1.2m x 0.6m tank IK testing using vertical, pendulum and spring hammer Vibration Testing Electro-dynamic Up to 24kN, 5 to 5kHz, +/- 38mm displacement Other Testing Constant acceleration Up to 20G and a load of up to 50kg Hydraulic Mechanical Up to 60kN, 2-90Hz, 300mm displacement 2-8Hz, 25mm displacement, 1500kg, 2x1.2x1.2m table Mechanical strength (structural load) testing Multichannel, multiaxis, static and fatigue testing Up to 100kN (static) and 0.1 to 10Hz, 500mm displacement (fatigue) Bump, transport and loose load Solar irradiation testing Indoor solar simulator with maximum area 5m 2 variable up to 1200W/m 2 Pressure and Altitude Testing Pressure Altitude Pressure and vacuum Mechanical Shock Testing Vertical drop Up to 34MPa Up to 50,000 ft equivalent and 65 C Rapid and explosive decompression Chambers up to Ø1400mm x 2500mm Up to 20,000G, 0.2ms halfsine, 43m/s, <50kg, 300mm wide platform Up to 2000G and between 1ms and 20 ms halfsine, <125kg, 500mm wide platform Up to 350G and between 1ms and 30ms halfsine, <900kg, 1m wide platform Chemical resistance and exposure tests Electrical Noise Outdoor solar tracker with dual axis tracking mechanism with maximum area of 6m 2 Outdoor test rig facilities up to maximum of 12m 2 Various automotive, aerospace or domestic chemicals Electrical safety and energy performance testing Airborne noise monitoring and analysis Structure born noise monitoring and analysis Incline drop Underwater shock Incline up to 100G and between 5ms and 50ms halfsine, 4m x 2m x 1m typical capacity 200G, test items up to 200kg (MIL 901D Light Weight) 6 environmental testing services

environmental testing services Environmental Testing Australia Environmental Testing Laboratories Melbourne Adelaide Sydney Rail Medical Equipment Packaging Manufacturing Defence OFFICE LOCATIONS MARKETS Consumer Electronics Industrial Components Building Components Automotive Aerospace CONTACTS Geoff Peacock Sales Engineer BEng(Elec), DipEng(Mech), DipBus(Mgmt) PERTH OFFICES ALSO IN SINGAPORE & HONG KONG See back cover for contact details ADELAIDE MELBOURNE LAUNCESTON HOBART BRISBANE HUNTER VALLEY SYDNEY Jay Bagga Sales Executive MMgt(Marketing) Gregory R King Operations Manager BSc(Hons), MSc, CEng, MInstR, FIMechE, FCIBSE, MAIRAH environmental testing services 7

Melbourne Corporate Head Office t. +613 9647 9700 f. +613 9646 4370 e. melbourne@vipac.com.au Adelaide t. +618 8362 5445 f. +618 8362 0793 e. adelaide@vipac.com.au Brisbane t. +617 3377 0400 f. +617 3377 0499 e. brisbane@vipac.com.au Hobart t. +613 6244 5556 f. +613 6245 9200 e. tasmania@vipac.com.au Hong Kong t. +852 2528 9378 f. +852 2987 8217 e. hongkong@vipac.com.au Hunter Valley t. +612 4950 5833 f. +612 4950 4276 e. huntervalley@vipac.com.au Launceston t. +613 6343 2077 f. +613 6343 4849 e. tasmania@vipac.com.au Perth t. +618 9277 3335 f. +618 9277 3325 e. perth@vipac.com.au Singapore t. +65 6353 8711 f. +65 6353 4211 e. singapore@vipac.com.au Sydney t. +612 9422 4222 f. +612 9420 5911 e. sydney@vipac.com.au www.vipac.com.au