Cable Limiters. Increase System Reliability Decrease Downtime PRODUCT GUIDE



Similar documents
MERSEN. Safety & Reliability for Electrical Power

Operation and Maintenance manual. fusible shunt trip switch

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer

Short Circuit Current Calculations

Heating Cable. Construction

Engineering Series Ratings: Is It Practical?

The MC Cable Revolution is Gaining Ground REMKE

Protect your home and family with Advanced Technology from Cutler-Hammer

Circuit Protection. Copper Cable Limiters (600Vac) Copper/Aluminum Cable Limiters (250Vac)

Voltage Drop (Single-Phase)

ELECTRICAL INSPECTION BULLETIN (Effective )

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

CONDUCTOR SHORT-CIRCUIT PROTECTION

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Mission Critical Data Center Systems

KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES

How To Get A Power Line Extension

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Cable/Conduit Conversion

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

Introduction. Upon completion of Basics of Load Centers you should be able to: Explain the role of a load center in residential power distribution

Federal Wage System Job Grading Standards for Electric Power Controlling, Table of Contents

SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM

Multiple Meter Installation Amperes Per Position -Single Phase, Self-contained

Application of Four-Pole Circuit Breakers within Data Centers

CHAPTER 2 EXAMPLES AND TABLES

BASIC NEC CODE RULES AND DESIGN PRACTICE

Continuous Power... Continuous Protection

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Direction of current flow through conductor. Fig. 1 Magnetic field generated by current flow

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

Qualitative Analysis of Power Distribution Configurations for Data Centers

Solar Circuit Protection Application Guide. Complete and reliable solar circuit protection

East Central College HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Defining the Needs of Modern Data Center Power Systems, Low Voltage Circuit Breaker Application

ELECTRICAL SAFETY Information Bulletin

Arc Terminator Active Arc-Resistant Switchgear

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Cable Tray Selection-

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

USA: 866.LAWSON4U ( ) Canada: lawsonproducts.com. Electrical Industrial and Fleet Solutions

Unified requirements for systems with voltages above 1 kv up to 15 kv

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

Line Loss WSDOT Winter 2008 BZA

SINGLE FAMILY DWELLING ELECTRICAL SERVICES RATED 225 TO 600 AMPS

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

MOBILE HOME SERVICE REQUIREMENTS GAS

PRODUCT / APPLICATION INFORMATION

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

HIGH VOLTAGE SHORE CONNECTION

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

Atlanta Chapter IEEE Industry Applications Society

Tel.X Ni-Cd battery. The compact maintenance-free solution for telecom networks

Arc Fault Circuit Interrupters Frequently Asked Questions

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

Requirements for Electrical Installations

Reliability requires consulting engineers and end users to grasp design, maintenance basics. By Reza Tajali, P.E. Square D Power Systems Engineering

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Comparative study for cables and busbars

CITY OF LOS ANGELES CALIFORNIA

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

Addendum #2 Contract UK-11-13

BC Hydro. Electric Distribution System Cost of Service Study

UL 508A Industrial Control Panels Power Distribution and Control. Lunch & Learn Training Eaton Corporation. All rights reserved.

Construction Technologies Career Field Pathways and Course Structure

THE STABILOY BRAND ADVANTAGE UNLOCKING THE SECRETS OF ALUMINUM A LOOK AT THE ADVANTAGES OF ALUMINUM ALLOY OVER COPPER

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

ENERGY HYDRO POWER SOLUTIONS FOR ELECTRICAL POWER TRANSFER ELECTRICAL PROTECTION SEALING

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES

MCC Ratings. Voltage Rating

PLEASE NOTE. For more information concerning the history of these regulations, please see the Table of Regulations.

Extension Cord Safety Policy

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Chapter 9. Bonding and Grounding

MONTGOMERY COUNTY EXECUTIVE REGULATION Offices of the County Executive. 101 Monroe Street. Rockville, Maryland 20850

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

Primary and Secondary Electrical Distribution Systems

Low Voltage Transformer Through-Fault Protection: A System Approach

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

2012 CATALOG AEROSPACE VVIRE & CABLE INC. aerospacewire.com

Voltage Loss Formula s

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Self-Regulating Low Temperature Heating Cable

Secondary Unit Substations

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

POWER DISTRIBUTION. Power and Undercarpet Products POWER AND UNDERCARPET PRODUCTS. Chapter Summary

Transcription:

Limiters Increase System Reliability Decrease Downtime PRODUCT GUIDE

Mersen Limiters Increase system reliability and versatility with Mersen Limiters. Increase system reliability and versatility with Mersen Limiters designed for the protection of low voltage distribution networks, feeders and service entrance cables. Permitted by National Electric Code Article 230.82(1), cable limiters prevent service outages by isolating damaged cables ensuring continuity of customer power. Install Mersen cable limiters in underground power distribution systems found in commercial, industrial, and residential applications. limiters are designed for use in both radial and network type underground systems to reduce the hazards of unexpected downtime and maintenance. Mersen offers a full line of both 600VAC and 250VAC cable limiters, with the 600VAC product line being UL Listed for code compliance. Select the proper limiter for your application by choosing from seven available terminal combinations suitable for aluminum or copper wire sizes from 1 AWG up to 1000kcmil. Customer Benefits limiters offer users an inexpensive solution to prevent costly downtime. limiters isolate faulty cables and allow the remaining cables to keep your business up and running. Faulty cables can now be pulled and replaced during a scheduled or routine shutdown when power is not needed. Applications and Installation Three common cable limiter applications include: 1. Distribution network systems with three or more cables in parallel per phase Install cable limiters on each end of each cable to allow for isolation of damaged cables. The limiters remove damaged cables from the circuit to maintain service. 2. Commercial and residential applications with multiple customers fed from one transformer Install one cable limiter on the secondary of the utility transformer per cable run. Allow businesses and homes to maintain power if a fault may occur. 3. Secondary Ties Protect circuits that connect two power sources or power supply points to prevent vaporization of cables under short circuit faults.

Application #1 - Three or More Conductors per Phase For larger ampere rated systems it is common to use several smaller cables in parallel, instead of one large cable, to share a heavier load. For this application, cable limiters are installed on the secondary of the utility transformer and on the line side of the service entrance disconnect. It is important to install cable limiters on each end of each cable. In most cases the customer hired contractor is responsible for installing limiters at the utility transformer and on the line side of the service entrance disconnect at the building. If one cable experiences a fault, the faulty cable will be isolated from the network, allowing the remaining cables to maintain power to the system. The damaged cable can now be replaced during a scheduled shutdown when revenue gain or production is not at risk of downtime. Unexpected power loss can result in lost revenue. Industrial Application Example NEC Article 230.82(1) permits the installation of cable limiters on the supply side of the service entrance disconnect. Ensure system reliability, guarantee operation, reduce maintenance costs and prevent unexpected downtime. Benefit from using cable protection in all types of industries such as metal fabrication, wastewater, assembly, electronics, textile, oil and gas, pulp and paper, rubber, steel, aluminum, glass and chemical. Mersen cable limiters are designed to withstand harsh environments and will not deteriorate from elements such as age, moisture or environmental surroundings. Mersen limiters are self-contained and self-protecting. Various termination offerings accommodate all types of installations. OPEN Fault Utility Transformer Limiters Limiters Commercial Service Entrance Malls, strip malls, shopping centers, outlets, retail businesses, universities, government facilities, and office buildings are typical customers that benefit from the installation of cable limiters. Protect incoming power to the retail centers power distribution network. Construction work external to the facility is a major cause of damaged cables. Improperly marked dig sites, equipment malfunction and operator error can all result in potentially hazardous electrical faults. Protect commercial developments with cable limiters and prevent potential lost revenues to its tenants. Recommended Product: Amp-Trap CP

Application #2 - Secondary Ties Transformer Transformer NEC article 450.6(A)(3) states that any secondary tie, 600V or less nominal, shall be equipped with a protective device that will open under short-circuit conditions. Article 450.6(A) (3) permits the installation of a cable limiter as an acceptable method of meeting this requirement. Limiter A secondary tie is a point in a circuit where two power sources or power supply points are connected, such as the secondary of two transformers. For example, this could be two individual transformers or a bank of transformers operating as a unit. Overcurrent Protection Service Service Recommended Product: Amp-Trap CP Application #3 - Multiple Services Supplied by a Single Source Utility Transformer Multiple services such as residential developments, apartment buildings, and small commercial buildings consume lighter loads and are often fed from a single transformer. To prevent the entire neighborhood, apartment building or strip mall from experiencing an outage, cable limiters are installed on each cable run to each individual service. In the case of a cable fault, the faulty service will be isolated from the remaining customers. For this application only one cable limiter is required per cable run on the secondary of the utility transformer. Limiters Customer Customer Customer Customer Recommended Product: Amp-Trap CP and 2CL

Amp-Trap CP 600VAC Limiters Approved 600VAC limiters for heavy commercial and industrial applications. Ideal for multiple cable runs per phase. Increase reliability and prevent unexpected downtime. UL Listed, File E305297 600VAC, 200kA IR Superior short circuit protection sizes #2 1000kcmil Seven terminal combinations available Copper or Aluminum cable Optional heat shrink or molded rubber boots available Amp-Trap 2CL 250VAC Limiters Approved 250VAC limiters for light commercial and residential applications. Protect underground cable runs from thermal damage caused by short circuits. Mersen Certified 250VAC, 200kA IR Superior short circuit protection sizes #1 500kcmil Four terminal combinations available Copper or Aluminum Shorter in length than standard 600VAC rated cable limiters Installation information, including crimping tool recommendations, limiter performance characteristics and part numbers is available online at ep-us.mersen.com or by contacting your local sales representative.

Main production sites Industrial or commercial branch A WORLD LEADER in safety & reliability for electrical power A GLOBAL PLAYER Since its foundation in 1892, MERSEN has built an international reputation by creating subsidiaries on all continents. Today with industrial and commercial plants scattered in more than 30 countries, agencies and representatives in more than 70 countries and 250 commercial contacts throughout the world, MERSEN offers its customers everywhere reliable, high technology products and services backed by its expert technicians. BR-CL-002 PDF Mersen 2011 Mersen U.S.A. 374 Merrimac Street Newburyport, MA 01950 U.S.A. T : 978 462 6662 F : 978 462 0181 Mersen FRANCE 15 Rue Jacques de Vaucanson F-69720 Saint Bonnet de Mure France T : +33 (0)4 72 22 66 11 F : +33 (0)4 72 22 67 13 Mersen TORONTO 88 Horner Avenue Toronto, Ontario Canada M8Z 5Y3 T : 416 252 9371 F : 416 252 6572 Mersen SHANGHAI No.55-A6. Shu Shan Road Songjiang 201611 Shanghai Tel: +8621 67602388 ep-us.mersen.com