FCAP Array v3.0 Software: A New Tool to Analyze BD Cytometric Bead Array (CBA) Data. Monisha Sundarrajan, PhD BD Biosciences



Similar documents
Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and

Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose

Introduction to Flow Cytometry

Preparing BD Systems for Data Migration. Summary of the Upgrade Process on page 6. Copying User Data Files onto an Upgraded System on page 7

BD Cytometric Bead Array (CBA) Mouse/Rat Soluble Protein Master Buffer Kit

Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking

Technical Bulletin. Standardizing Application Setup Across Multiple Flow Cytometers Using BD FACSDiva Version 6 Software. Abstract

CyTOF2. Mass cytometry system. Unveil new cell types and function with high-parameter protein detection

Analyzing Samples for CD34 Enumeration Using the BD Stem Cell Enumeration Kit

BD FACSComp Software Tutorial

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer

BD Cytometric Bead Array (CBA) Human Inflammatory Cytokines Kit

COMPENSATION MIT Flow Cytometry Core Facility

APPLICATION INFORMATION

Immunophenotyping peripheral blood cells

BD FACSCalibur. The flow cytometer for your routine cell analysis needs

LEGENDplex Data Analysis Software

BD FACSVerse. Simply brilliant

High Throughput Assays for Mouse Metabolic Markers: Insulin, Leptin and Adiponectin

Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer

Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement

Technical Bulletin. An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers

BD FC Beads 8-Color Kit for BD OneFlow Assays

Getting Started with BD FACSDiva Software

Soft Flow Hungary. Soft Flow Hungary. RIÜNET: Innováció és gazdaságfejlesztés Gödöllő, december 8.

ELITE Custom Antibody Services

TaqMan Genotyper Software v1.0.1 TaqMan Genotyping Data Analysis Software

Windows OS Security/Critical Patch List for BD Workstations

Fluorescent Array Imaging Reader

Information security guidelines

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

INSTRUCTION Probemaker

Standard Operating Procedure

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Meso Scale Discovery. WINDOWS is a registered trademark of Microsoft Corporation

Instrument Characterization and Performance Tracking for Digital Flow Cytometers

Introduction to Flow Cytometry

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

Cytell Cell Imaging System

The Quanterix products referenced in this document are for research use only and are not for diagnostic or therapeutic procedures.

The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee

BD FACSCanto Flow Cytometer. Efficient Easy Powerful

BD CellQuest Pro Software Analysis Tutorial

a measurable difference

ArC Amine Reactive Compensation Bead Kit

Immunophenotyping Flow Cytometry Tutorial. Contents. Experimental Requirements...1. Data Storage...2. Voltage Adjustments...3. Compensation...

Simoa HD-1 Analyzer Troubleshooting Guide. USER Sep 2014 Software Version 1.3 Beta

Superior TrueMAB TM monoclonal antibodies for the recognition of proteins native epitopes

TruSeq Custom Amplicon v1.5

Three Rules for Compensation Controls

EdU Flow Cytometry Kit. User Manual

KMS-Specialist & Customized Biosimilar Service

ab Protein Sumoylation Assay Ultra Kit

Stem Cell Research Source. From Isolation to Culture and Analysis

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

SmartFlare RNA Detection Probes: Principles, protocols and troubleshooting

Data Analysis on the ABI PRISM 7700 Sequence Detection System: Setting Baselines and Thresholds. Overview. Data Analysis Tutorial

T-Cell Research. Novel multicolor flow cytometry tools for the study of CD4 + T-cell differentiation and plasticity

Human Luteinizing Hormone (LH) Custom Kit

PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required.

White Paper. BD Assurity Linc Software Security. Overview

Using FileMaker Pro with Microsoft Office

CFSE Cell Division Assay Kit

Establishing Optimum Baseline PMT Gains to Maximize Resolution on BD Biosciences Digital Flow Cytometers

BD FACSDiva Software Reference Manual

Automation of Cell Staining Technical Information Bulletin

Beckman Coulter DTX 880 Multimode Detector Bergen County Technical Schools Stem Cell Lab

Frequently Asked Questions (FAQ)

Secretion Assay Cell Screening Service Gel Microdrop

Advantages of the Alexa Fluor 488 secondary antibody conjugates

BD Cato Medication Workflow Solutions

BD StemFlow Human Pluripotent Stem Cell Sorting and Analysis Kit

Strategic Analysis of the U.S. Research Antibodies Market Presenting Opportunities for Market Share Gain

Application Note 10. Measurement of Cell Recovery. After Sorting with a Catcher-Tube-Based. Cell Sorter. Introduction

HuCAL Custom Monoclonal Antibodies

THE His Tag Antibody, mab, Mouse

Validated Cell-Based Assays for Rapid Screening and Functional Characterization of Therapeutic Monoclonal Antibodies

Bacterial Detection and Live/Dead Discrimination by Flow Cytometry

Standardization, Calibration and Quality Control

Introduction to flow cytometry

1.Gene Synthesis. 2.Peptide & Phospho-P. Assembly PCR. Design & Synthesis. Advantages. Specifications. Advantages

Software Getting Started Guide

Compass Software for Peggy User Guide

VersaCall s Performance Intelligence Software

imc FAMOS 6.3 visualization signal analysis data processing test reporting Comprehensive data analysis and documentation imc productive testing

BD Biosciences ELISA and ELISPOT Product List

Evalution the multiplexed analysis of biomarkers made fast and simple by MyCartis

Boundary-breaking acoustic focusing cytometry

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

imc FAMOS 6.3 visualization signal analysis data processing test reporting Comprehensive data analysis and documentation imc productive testing

Diagnosis of HIV-1 Infection. Estelle Piwowar-Manning HPTN Central Laboratory The Johns Hopkins University

Let the BD FACSAria II accompany your best performance ever

Welcome to the fully integrated autoimmune laboratory. Saves time by reducing hands-on functions NOVA Lite Barcoded IFA Slides

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

RPCI 004 v.002 Staining Procedure For all Directly Conjugated Reagents (Whole Blood Method)

EZValidation Online Tool. The easy way to apply guidelines. The EZValidation Online Tool. The implementation of new tests

QuantStudio 3D AnalysisSuite Software: Relative Quantification

How to operate the BD FACSCanto flow cytometer

Protein Analysis. -Detection and quantification. Toby M Holmes

Welcome to More Choice BD Analyte Specific Reagent (ASR) Catalog

Transcription:

FCAP Array v3.0 Software: A New Tool to Analyze BD Cytometric Bead Array (CBA) Data Monisha Sundarrajan, PhD BD Biosciences 23 13795 00

Agenda Introduction Overview of BD CBA bead based immunoassays FCAP Array v3.0 key features Live demonstration of data analysis in FCAP Array v3.0

Cellular communication and signaling Cytokines and Growth Factors Cell Signaling

Summary of Techniques for Measurement of Cytokines Soluble Proteins ELISA ELISPOT BD CBA Intracellular Proteins Flow Cytometry WB IHC BD CBA

BD CBA Assay Overview Analytes are bound by specific capture antibodies conjugated to beads with distinct fluorescent properties Based on an antibody pair, the same principle as a sandwich ELISA The reporter in the assay is a PE-labeled detection antibody Analyte concentrations are estimated by comparison with a standard curve

Bead Based Immunoassay Overview Advantages Analyze multiple cytokines simultaneously ( 30) Reduced sample volume requirements Reduced hands on time with parallel analysis of samples Wide dynamic range (fluorescence) Requires fewer sample dilutions High statistical relevance 300 beads measured per cytokine equivalent of 300 ELISA wells BD CBA is like doing multiple ELISAs at the same time by flow cytometry

Comparison with ELISA BD CBA Uses culture supernatant or serum/plasma High statistical relevance Can detect multiple cytokines simultaneously Fewer sample dilutions due to broad dynamic range Requires a flow cytometer and analysis software ELISA Uses culture supernatant or serum/plasma Must run samples at least in duplicate One cytokine per ELISA plate Requires multiple sample dilutions Relatively easy to perform and fairly inexpensive

The BD CBA Workflow Stain Acquire Analyze BD CBA Kits BD CBA Flex Sets BD FACSVerse BD LSRFortessa BD LSR II BD FACSCanto II BD FACSAria III BD FACSArray BD FACSCalibur FCAP Array v3 (Windows ) FCAP Array v1 (Mac )

BD CBA Reagent Configurations BD CBA Kits Preconfigured panels of 3 to 7 analytes Th1/Th2 Th1/Th2/Th17 Inflammatory Cytokines Anaphylatoxins Includes all reagents required to run the assay 80 tests per kit 2 color assay Red dye in beads PE reporter BD CBA Flex Sets Build your own multiplex Human Soluble Protein Mouse or Rat Soluble Protein Enhanced Sensitivity (>274 fg/ml) Cell Signaling Human Immunoglobulin Flex Set = Capture Beads, Detection Reagent, Standard (2 curves) 100 tests Master Buffer Kit = all buffers needed for assay 100 or 500 test sizes 3 color assay Two red dyes in beads PE reporter

Instrument Compatibility: BD CBA Kits 70 60 50 Count 40 30 20 10 0 10 1 10 2 10 3 10 4 10 5 CBA Red-A

Instrument Compatibility: BD CBA Flex Sets 10 5 BD CBA Flex Set - 30 plex CBA NIR-A 4 10 10 3 2 10 0-10 2 0 10 2 10 3 10 4 10 5 CBA Red-A

Tools to Simplify Data Acquisition bdbiosciences.com/cbasetup Download templates and instructions Instrument setup Data acquisition Assay instructions: either in BD CBA kit or flex set manuals

FCAP Array v3.0 Analysis Software Compatible with FCS 2.0 or 3.0 files from any flow cytometer Integrated workflow for the BD FACSVerse flow cytometer Windows 7, Vista, or XP compatible

Design View Identify location of data files Assign to standards and samples

Beads and Model Select the beads corresponding to analytes in your experiment from the bead library Download a bead library file from bdbiosciences.com/cbasetup

Instrument Settings Verify scatter, clustering, and reporter parameters Assign beads to clusters

Standards and QC Assign concentration levels to the standard curves Manual entry or dilution profile calculator

Standard Curves Review standard curves Options: force through zero, axis scale (lin/log), curve type, weighting, fitting accuracy, colors

Results View raw data by analyte or by sample Chart options for visualization and export Bar chart, 3D bar chart, polar chart

Additional Features Manual clustering available in instances when the automatic algorithm cannot identify all bead clusters Debris filtering available for cases when debris is causing the automatic algorithm to fail Summary reports available in PDF Raw data export to a spreadsheet Export standard curve and chart images as JPG, BMP, or PNG

Summary BD CBA reagents are available in two formats BD CBA kits: preconfigured panels of 7 analytes BD CBA flex sets: mix and match, up to 30 analytes Flex sets also available in Enhanced Sensitivity format Assay range: 274 to 200,000 fg/ml Compatibility with BD FACS brand flow cytometers New FCAP Array v3.0 analysis software with intuitive workflow and enhanced features

Acknowledgment BD Biosciences Trent Colville, Senior Product Manager, Marketing Soft Flow Hungary György Lustyik, PhD, President Zoltán Mike, Lead Developer For Research Use Only. Not for use in diagnostic or therapeutic procedures. Cy is a trademark of Amersham Biosciences Corp. FCAP Array is a trademark of Soft Flow Hungary Ltd. Mac is a registered trademark of Apple Computer, Inc. Windows and Vista are registered trademarks of Microsoft Corporation. BD, BD Logo and all other trademarks are property of Becton, Dickinson and Company. 2011 BD