Thermometer in stainless steel with capillary and switch contacts



Similar documents
Bimetal thermometer Model 52, industrial series

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

2.12. page Products for Explosion hazardous Environment

T R A N S F O R M E R A C C E S S O R I E S SAM THERMOMETERS

Plastic tube flowmeters Series PT/PS

Safety at a high level!

Threaded Resistance Thermometers Model TR10-D, Miniature Design

VDL 53 - Vacuum drying oven for flammable solvents

Digital display DA 48

Inductive sensor NI10-M18-Y1X-H1141

79 GAUGE / THERMOMETER H N O

OLI. Oil level indicator

Flow switches Series AD/VH

Turbine Flow Sensor Series VTR

Stainless steel process fittings

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

How To Use A Ds340 (Dsp)

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

System 8. ü ( System 8

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches.

ISO/VDMA Actuators. Engineering GREAT Solutions

SITRANS F flowmeters SITRANS F M

B-Series Temperature Switches

8146/5 Series Breaker Panelboards

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION TOR REED SWITCH

Self-operated Temperature Regulators Temperature Regulator Type 1u

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Cylinders DIN ISO 6431 and VDMA

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

3/2-way Solenoid Valve, direct-acting, NC or NO

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Electrical switch contacts

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Hose and Tube Fittings Series 1-3

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

COMBIMASS. Technical Data COMBIMASS eco-bio +

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * Thermostat for CH 12/18

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

SEISMIC VELOCITY TRANSDUCER T1-40

servo-controlled 3-WaY vacuum solenoid valves WiTH

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Cylinders Series 40. Double acting, cushioned, magnetic ø (DIN/ISO 6431)

Mobrey Hydrastep and Hydratect

Cable Plug acc. to DIN EN , Form A

Technical data sheet TDS0070

Scraper Passage Indicator. Electrical Indicator. Features

RM/55401/M, Roundline cylinder Magnetic piston, double acting

Switches SWITCHES SWITCHES

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

Solenoid Valve Island Type 3965

Electro-pneumatic control valves

Givare NC-SRS 280 och 880

Mini USB and USB 2.0-IP67 Connector System

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Operating Instructions

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

Inductive sensors. Compact, fast, reliable. Edition 2013

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Compact pressure switch Flameproof enclosure Ex d Model PCA

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal T [] C

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

RTD Temperature Probe for the Food/Pharmaceutical Industry

Terminal Boxes Series 8146

Relative pressure transmitter type 520

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

OPTIMASS 6000 Technical Datasheet

Bypass level indicator With magnetic display Model BNA

HMI Components. Series. Indicator Pushbutton Illuminated pushbutton. Machinery and Automation Building technology Panel building.

Technical Data. Dimensions

Worcester DS/DM Series UltraSwitch Switch box

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Mechanical pressure switches

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Working Pressure up to 630 bar / 9135 PSI

How To Fit A Portman Door Leaf

Electronic Pressure Switch EDS 300

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Technical Data. Dimensions

Vario-Series Accessories

Transcription:

Design Type Case diameter Thermometer in and switch contacts 7308 = back flange for wall mounting 7312 = front flange for panel mounting 7310 = mounting bracket for wall mounting Dim 100 mm or 160 mm Accuracy Class 1,0% DIN EN 13190 Case Mounting Temperature element Working temperature Capillary Stem Length of stem Connection Working pressure Stainless steel with bayonet type bezel white dial of aluminium. Laminated safety glass. Back flange, front flange or mounting bracket Inert gas expansion system 100% of range by permanent measuring The endvalue can be excided 20% by short time Capillary of stainless steel (dim Ø2 mm) Ø 6, 8, 10 or 12 mm of stainless steel Stem length from 70 mm to 300 mm Type 1 = Plain stem without thread Type 2 = Male nut Type 3 = Union nut Type 4 = Compression fitting on stem Type 6 = Compression fitting on capillary Max pressure rating without thermowell = 25 bar Ingress protection IP 65 per EN 60529 Switch contacts Switch functions Electrical connection Optional extras Sliding contacts type 811, magnetic snap-action contacts type 821 or inductive contacts type 831. One, two or three switch contacts adjustable over the full extent of the scale range. Single or double function, see table next page Junction box at side Scale range in C+F (dual scale) Case with liquid damping (not by contact type 811) Version per ATEX Ex II 2 GD c TX Contacts with separate circuits Changeover contacts Temperature range -40+60 C -30+50 C 0+60 C 0+80 C 0+120 C 0+160 C 0+200 C 0+250 C 0+300 C 0+400 C 0+500 C 0+600 C

Magnetic snap-action contact type 821 Magnetic snap-action contact. Power supply max 250 VAC. Maximum load 30W, 50 VA, Current ratings max 1,0 A, Maximum load max 20W, 20 VA with liquid damped case Contact point material silver-nickel alloy, hysteresis 2-4% of full scale range. Single contact Double contacts Triple 821.1 821.2 821.11 821.12 821.21 821.22 821.212 1 x max 1 x min 2 x max min - max max - min 2 x min 2 max 1 min by rising and falling and breakes Sliding contact type 811 Sliding contact. Power supply max 250 VAC. Maximum load 10W, 18 VA, Current ratings max 0,7 A (type 811 can not be delivered with liquid damped case) Contact point material silver-nickel alloy, hysteresis 2-4% of full scale range. Single contact Double contacts Triple 811.1 811.2 811.11 811.12 811.21 811.22 811.212 1 x max 1 x min 2 x max min - max max - min 2 x min 2 max 1 min by rising and falling and breakes

Inductive contact type 831 Inductive contact type 831 is used in conditions with extremely swift changes or in explosion hazardous areas type Ex. Contact point material silver-nickel alloy, hysteresis 0,5% of full scale range. The inductive contact must be connected to a control unit which provide a low voltage to the contact. The control unit operates together with the inductive contact for functions as making or breaking the circuit. See datasheet E 03.12.01 Single contact Double contacts Trippel 831.1 831.2 831.11 831.12 831.21 831.22 831.xxx On special request 1 x max 1 x min 2 x max min - max max - min 2 x min Case with back flange type 7308 Type Case dim b1 c d d1 d2 d3 D1 D2 7308 100 88 94 6, 8, 10, 12 116 132 4,8 101 99 7308 160 88 124 6, 8, 10, 12 178 196 5,8 161 159

Case with front flange type 7312 Case dim b1 c d d1 d2 d3 D1 D2 100 88 94 6, 8, 10, 12 116 132 4,8 101 99 160 88 124 6, 8, 10, 12 178 196 5,8 161 159 Case with mounting bracket type 7310

Connection and stem Connection typ 1 Plain stem without thread Immersion length L1 and Connection typ 2 Male nut Connection typ 3 Union nut Connection typ 4 Compression fitting on stem Connection typ 6.1 Compression fitting on capillary Connection typ 6.2 Compression fitting on capillary with spiral protection hose Connection typ 6.3 Compression fitting on capillary on spiral protection hose