TROUBLESHOOTING PRELIMINARY



Similar documents
Essential Electrical Concepts

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:

Troubleshooting accelerometer installations

4 LEAD DEDICATED SINGLE PHASE LIMA MAC GENERATOR MODELS 250MSL1185 AND 250MSL1152

Rutland 913 Windcharger Fault Finding Guide

SPA BUILDERS LX-10 STANDARD TROUBLESHOOTING APPROACH

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

The full wave rectifier consists of two diodes and a resister as shown in Figure

Power Supplies. 1.0 Power Supply Basics. Module

Single-Phase AC Synchronous Generator

AC Direct Off-Line Power Supplies

Model RI ICE Pack Impressed Current Electronic Package the remedy for Mag headaches Typical Applications:

Battery Chargers. Revised 8/00 Form Number FORM NO / BATTERY CHARGER SERVICE MANUAL / PARTS LIST - 45

ALTERNATOR & REGULATOR - HITACHI

Properties of electrical signals

ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

ANALOG AND DIGITAL METERS ANALOG VS. DIGITAL METERS VOLTMETERS ANALOG AND DIGITAL

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

4 DEDICATED SINGLE PHASE LIMA MAC GENERATOR LIGHT TOWER DUTY MODELS 250MSL1278 AND 250MSL1299 SERVICE PROCEDURE ELECTRICAL COMPONENT TESTING

Troubleshooting And Repairing ATX Power Supply

R438 A.V.R. Installation and maintenance R 438. This manual is to be given to. the end user T10. Armature 6- Field X2 Z1 X1 Z2 E+ E- 0V

TROUBLESHOOTING GUIDE

Use your troubleshooting superpowers for good Application Note

Inverter / Charger Installation General Operations and AC and DC Connections

A.V.R. R250. Installation and maintenance R250 0V E+ E- VOLT STAB FREQ. & L.A.M. CONFIG. 50Hz. 47.5Hz. 57Hz LAM 1 13% 2 25% OFF LAM OFF 9

VOLTAGE REGULATOR AND PARALLEL OPERATION

BSNL TTA Question Paper-Instruments and Measurement Specialization 2007

Trouble Shooting Guide

6. Diagnostics for A/C System Malfunction

6/14/02 Chapter 14: Use of Electrical Test Equipment 1/20

Help protect your home, possessions and family.

Welcome to Linear Controls Quarterly Training

601 International Ave. Washington, Missouri (636) (636) (FAX) M REV C

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Emergency Power System Services Industrial UPS, Batteries, Chargers, Inverters and Static Switches

Failure code manual. content

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Checking Capacitor Banks for Failed Capacitors

Tips for connecting 24-volt power

R448 & R448 V50 A.V.R.

t... - GENERATORS - / SWITCHABLE VOLTAGE TRAILER MOUNTED GENERATOR W b 0 WER PLANTS-Over OPERATION and MAINTENANCE INSTRUCTIONS 45 Years of Leadership

ST Style Generator. Owners/Operators Manual

= V peak 2 = 0.707V peak

Chapter 22 Further Electronics

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

FUEL-16, Troubleshooting Fuel Supply Problems

Diagnosing Body Electrical Problems

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Unified requirements for systems with voltages above 1 kv up to 15 kv

Experiment 2 Diode Applications: Rectifiers

CHAPTER 2B: DIODE AND APPLICATIONS. D.Wilcher

A/C-HEATER SYSTEM - AUTOMATIC

Current and voltage measuring relays

Pump Maintenance - Repair

Lab 3 Rectifier Circuits

Lecture - 4 Diode Rectifier Circuits

(3) Explosion proof. Designed to prevent ignition of any explosive gases or dust and dirt which may surround the motor.

Installation and Operation Guide for PD4000 Series Power Control Center

Federal Wage System Job Grading Standards for Electric Power Controlling, Table of Contents

NATIONAL CERTIFICATE (VOCATIONAL)

Owner s Manual. ULTRA-POWER II ACCU-POWER & ACCU-POWER ONBOARD Solid State Fully Automatic Chargers. Manual Number Edition Code 0493B0101A

Electrical Circuit Theory

BIOMEDICAL ENGINEERING TECHNICIAN SERIES

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Federal Wage System Job Grading Standard for Powered Support Systems Mechanic, Table of Contents

Development Of A Re-Training Programme For Electronics Technicians On Basic Electronics Troubleshooting And Repairs

70-Series CAN Power Management System

TIG INVERTER INSTRUCTION MANUAL

Troubleshooting Salt Generators

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Unit/Standard Number. High School Graduation Years 2010, 2011 and 2012

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Electrical Diagnostic Tools

UNIVERSITY OF WATERLOO ELECTRICAL & COMPUTER ENGINEERING DEPARTMENT ME269 ELECTROMECHANICAL DEVICES AND POWER PROCESSING.

Installation and Operation Guide for PD4100 Series Power Control Centers

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

12-Volt Negative Ground Installation Instructions

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

INSTALLATION & SERVICE MANUAL. Display Panel

REFURBISHMENT and VERIFICATION of the HEATHKIT TT 1 TUBE TESTER

Quickie Rhapsody Service Manual

Cathodic Protection Use On Tank Bottoms & Underground Piping In Power Generation Plants

Fig. 1 Analogue Multimeter Fig.2 Digital Multimeter

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

POWER SUPPLY MODEL XP-15. Instruction Manual ELENCO

Directions for use : Dosing chutes type DSX.

Test Code: 8094 / Version 1

DIODE CIRCUITS LABORATORY. Fig. 8.1a Fig 8.1b

Type SA-1 Generator Differential Relay

STEALTH I DC MANUAL TECH SUPPORT WEB BLACK UNIT IS 24/36 ONLY

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

TOYOTA STARTING SYSTEMS. General

Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

TV Trouble Shooting Manual

Transcription:

TROUBLESHOOTING PRELIMINARY To troubleshoot, one must first have a working knowledge of the individual parts and their relation to one another. Must have adequate hand tools Must have basic instrumentation: Accurate digital voltmeter with diode test mode for silicon units Clamp-on AC DC ammeter Voltage detectors Cell phone very useful Observe all safety precautions

RECTIFIER COMPONENTS Cabinet - protects the rectifier components from the elements Circuit Breaker - serves as an on - off switch and overload protection Transformer - reduces the line voltage to a useable level for the cathodic protection system and isolates the CP system from the incoming power Rectifier Stack - used to change A.C. to D.C. (Silicon) or (Selenium) Fuses - to protect the more expensive components (like Diodes, ACSS,etc. Meters - used to indicate D.C. Voltage and D.C. Current Shunts - used to accurately measure circuit current Arrestors - protects the rectifier from voltage and lightning surges

TROUBLESHOOTING - BASIC An adequate inspection and maintenance program will greatly reduce the possibility of rectifier failure. Rectifier failures do occur, however, and the field technician must know how to find and repair troubles quickly to reduce rectifier down time.

MAJOR CAUSES OF RECTIFIER FAILURES 1. NEGLECT 2. AGE 3. LIGHTNING

TROUBLESHOOTING PRECAUTIONS Turn the RECTIFIER and the MAIN DISCONNECT OFF! Be careful when testing a rectifier which is in operation. Safety first Consult the rectifier wiring diagram before troubleshooting Correct polarity must be observed when using DC instruments Rectifier should be in the OFF position before using an OHMETER Common sense prevails

TROUBLESHOOTING PROCEDURES Most rectifier troubles are simple and do not require extensive detailed troubleshooting procedures. The most common problems are: Faulty meters Loose terminals Blown Fuses Open ground bed leads Lighting damage

TROUBLESHOOTING MORE DIFFICULT PROBLEMS It is usually better to systematically isolate the rectifier components until the defective part is found. TROUBLESHOOTING IS THE PROCESS OF ELIMINATION!

CHECK The AC voltage across line side of circuit breaker (Points A-A) The AC voltage across load side of circuit breaker (Points B-B) This voltage should be the same as points A-A. The input change taps for loose connections (Point C) Adjust for the correct input voltage. The transformer secondary tap link bars for the presence of voltage (Points D-E) Voltage may be measured between any of the secondary taps If the circuit breaker trips, indicating a short circuit, the transformer can be isolated by removing the link bars. If the circuit breaker continues to trip, the transformer is shorted. If the circuit breaker holds, the short is not in the transformer. The AC voltage supplied to the rectifier stack (Points F-G) This voltage should be the same as points D-E. If the circuit breaker trips, isolate the stack by removing one of the DC leads. (Points H or J) If AC voltage is supplied to the stack, check the DC output voltage. (Points H-J) If DC voltage is present but is less than expected, stack may have an open circuit and is half-waving.

CHECK If the circuit breaker does not trip when a DC lead on the stack is removed, but does when it is connected, a short circuit is probably is the external ground-bed or structure leads. If DC voltage is present at the stack Points J-H, but not at the rectifier output. Check for loose connections or open leads between Points J-K or H-L. If DC voltage is present at the rectifier output terminals, but no current is flowing, there is an open in one of the external DC Leads. Meters may cause the rectifier to appear defective. Check meter with portable meters known to be accurate. Meter switches may be checked with an ohmmeter. If it is suspected that the choke is defective, it may be effectively taken from the circuit by placing a heavy jumper lead across the choke leads. Capacitors in an interference filter are individually fused. If fuse is blown, replace with a new fuse and turn the on again. Lighting arrestors in rectifier may be isolated by removing them from the circuit.

TROUBLESHOOTING TIPS Many rectifier problems are relatively obvious to the experienced technicians upon physical examination. The obvious should never be overlooked! Loose connections, signs of arcing, strange odors, etc., indicate troubles, which do not require elaborate test procedure to uncover.

SOME HELPFUL TROUBLESHOOTING TIPS TO FOLLOW 1. No output voltage or current present. A. Breaker Tripped (or Fuse Blown) 1. Steady overload, reduce output slightly. 2. Short circuit in some component. B. No AC Line Voltage C. Open Circuit 1. Check all connections 2. Check all diodes in silicon stacks D. Defective meters or meter switches Paragraph 11, Troubleshooting Procedure section of your guide.

SOME HELPFUL TROUBLESHOOTING TIPS TO FOLLOW E. Defective Transformer, good primary input, but no secondary output. 1. Secondary probably open. 2. Check DC resistance of windings with an ohmmeter. (a.) Secondary should have less than 1Ώ resistance. (b.) Primary should have 1-10Ώ resistance (c.) An open circuit is possible if resistance is extremely high. F. Circuit Breaker (or thermal overload protectors). If contacts do not close, repair or replace breaker.

SOME HELPFUL TROUBLESHOOTING TIPS TO FOLLOW 2. If maximum DC output voltage at rated DC current is half output. A. Check for proper AC input voltage. B. Check stacks for plates open circuit, this would make unit operate as a half-wave rectifier. C. Badly aged stacks. D. For 3Ø rectifiers, in addition to the above 1Ø rectifiers. (1.) Open circuit if, one AC line is considerably less than the other two. (2.) One of three stacks are more aged than the other two. E. Low line voltage.

SOME HELPFUL TROUBLESHOOTING TIPS TO FOLLOW 3. Variable Transformer Control Some rectifiers may be equipped with a variable transformer in lieu of the standard tap and link bar arrangement. The variable transformer will provide step-less, infinite control of the output of the rectifier.

TROUBLESHOOTING THE VARIABLE TRANSFORMER Troubleshooting the variable transformer will be the same as the procedure for the main transformer. A. AC input voltage should be checked across terminals one and four. B. Output AC voltage can be checked across terminals one and three. (Control knob should be at maximum rotation. C. Output voltage should be the same as Input voltage. D. If no AC voltage is present on the output terminals of the variable transformer, check for open winding, dirty or worn wiper brush.

TYPICAL SINGLE PHASE RECTIFIER

TYPICAL THREE PHASE RECTIFIER