Inverter Air Conditioning for Light Commercial Use



Similar documents
Inverter Air Conditioning for Light Commercial Use

Air Conditioning for Small and Medium-size Buildings

Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and

Air Conditioning For Large Buildings

york air-conditioning products Residential & VRF News 2015

FULL DC INVERTER SYSTEMS

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A

Unico Inverter. Unique and efficient.

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

Appendix - Controllers 179

HP switch LP switch Discharge thermo Comp. Surface thermo

2015 / 16. price list. Airconditioning systems

DUCTED AIR CONDITIONING SOLUTIONS

SALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units

LG Electronics AE Company, Commercial Air Conditioning

utopia Split Systems DC Inverter 7kW-14kW G8 5kW-25kW

Contents. Part 1 General Information Part 2 Outdoor Units Part 3 Installation Part 4 Troubleshooting 73

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Multi Air Conditioning System for Buildings

NEW 3-PIPE ECOi MF2 SERIES

Air Conditioners Technical Data

Pioneer in sustainability

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

innovative comfort solutions

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Models Utopia ES Utopia IVX Utopia DC Inverter Utopia Fixed Speed Utopia Centrifugal

FBQ. DC Duct Heat Pump or Cooling Only

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY

HEATER, AIR CONDITIONING AND VENTILATION

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

ECO-AIR AIR CONDITIONING

ECOCIAT. Domestic hot water heat recovery unit

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

SiBE D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

FTXS. Wall Mount Heat Pump or Cooling Only

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

Versati Air to Water Heat Pump

FTQ. Daikin Inverter Ducted Heat Pump

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C)

SiUS Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

Samsung Room Air Conditioning

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

CRAC Precision climate control units for data centres

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Glossary of Heating, Ventilation and Air Conditioning Terms

Residential and Light Commercial Air Conditioning Systems

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

LG Duct-Free Split Systems Product Overview. LG comfort solutions that you never thought possible

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

FHQ. Ceiling Suspended Heat Pump or Cooling Only

INVERTER IN-CEILING CASSETTE. Ideal for various applications including the lounge, family room, restaurants, hotels, offices and meeting rooms.

PRODUCT CATALOG. Indoor Units

Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit

Cooling kw Heating kw

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

VRF CATALOGUE HEAT PUMP & HEAT RECOVERY. for Europe. Variable Refrigerant Flow System

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Residential and Light Commercial Air Conditioning Systems

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

Models Monozone/Multizone (NH4/QH4) Summit (YH4) Big Flow (GH4/G4) New Air Exchanger (JX4)

Portable Air Conditioner

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS

PORTABLE AIR CONDITIONER

GREE, MAKING BETTER AIR CONDITIONERS

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg

PLA. Advancements in PLA series improve style and performance for ensured indoor comfort. 4-way Ceiling Cassette. Wide Airflow.

LG AIR CONDITIONERS 2014 Ducted Split System

AIR-CONDITIONER SPLIT TYPE

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

System. SERVICE MANUAL R410A MODEL : ARNU Series URNU Series

SiUS Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Operating Instructions Split System Air Conditioner

How to choose a heat pump and use it wisely

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

FCQ. Roundflow Cassette Heat Pump or Cooling Only

U-MATCH Air Conditioners. Service Manual. T1/R410a/50Hz


2 NOMENCLATURE 3 FUNCTION 4 PRODUCT DATA

Central Air Conditioner

Development and testing of a multi-type air conditioner without using AC inverters

technology innovation, comfort for your home. The perfect blend of

Screw Compressors ESM Fixed Speed & VS Variable Speed

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

WINDOW ROOM AIR CONDITIONER

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

SWIMMING POOL HEAT PUMP

LOCAL AIR-CONDITIONERS

Transcription:

Inverter Air Conditioning for Light Commercial Use

Index Introducing Light Commercial 4 SDI-Super Digital Inverter 6 DI-Digital Inverter 7 DI Big 8 SDI-Super Digital Inverter & DI-Digital Inverter Lineup 10 Indoor units Compact 4-Way Cassette (600 600) type 14 4-Way Cassette type 17 Slim Duct type 21 Standard Duct type 24 Concealed Duct High Static Pressure type 28 Ceiling type 30 High-Wall type 34 Twin, Triple & Double twin system 37 SDI-Super Digital Inverter & DI-Digital Inverter Controllers & Accessories 42 SPI 44 SPI Indoor units Appendix Outdoor unit drawings 50

3 SDI Super Digital Inverter DI Digital Inverter SPI Toshiba solutions Toshiba offers a solution for all applications: residential, light commercial and larger commercial buildings. For small commercial premises, products are designed to deliver top performance combined with energy efficiency. Superior comfort Toshiba s commitment to society drives a company-wide focus on attention to the details through every stage of the development process, from design to user field tests. Installations using our products and systems therefore feature a higher standard of indoor air quality, sound levels, energy savings, and environmental awareness. Toshiba can help you create a comfortable space while also caring for the environment.

4 Light Commercial The Toshiba Super Digital Inverter and Digital Inverter series air conditioners combine economy and ecology in a compact body. They feature state-of-the-art technology, flexible control, and easy installation to bring natural comfort and convenience to any business environment. A complete range of indoor units: Cassette, Ducted, Ceiling and High-Wall units Superior EER Very efficient energy consumption, Keeps down operating costs. EER of 4.52* achieved by Toshiba s unrivalled Super Digital Inverter technologies and newly developed components. *4HP outdoor unit, Heating ECO-driving DC twin rotary Super Digital Inverter / New 4-Way Cassette (EER) 5.0 4.0 3.0 2.0 1.0 0.0 3.46 3.68 4.52 3.96 2 HP 3 HP 4 HP 5 HP Digital Inverter / New 4-Way Cassette (EER) 5.0 4.0 3.0 2.0 1.0 0.0 3.21 3.02 3.31 2.80 2 HP 3 HP 4 HP 5 HP Vector-controlled inverter Vector IPDU control changes the motor current wave to a smooth sine pattern so that noise emitted from the drive units is greatly reduced. High efficiency heat-transfer (flat fin) Heat-transfer tube with improved heat-transfer coefficient. A low minimum speed of 10 rps has been achieved. This has further improved the operating efficiency when the load is low (the minimum in Series 2 was 15 rps). High power motor DC fan motor Highly Efficient DC Motor. Bat wing fan New development for high-pressure low-volume fan. Wide-flow grille Optimizing ventilation performance, Bringing out the full effect of fan and motor. DC twin rotary A low minimum speed of 10 rps has been achieved. Operation in Power Save Mode enables power peaks to be cut. Newly designed compression path More precise components Rotor with slit The structure and shape of each compressor component has been optimised. The area of the rotor magnet has been increased and a slit introduced to the design. These improvements have further Large-area magnet enhanced efficiency and reduced noise. Note: Actual component may vary considerably from specifications depending on product model.

5 R410A refrigerant An ozone layer depletion coefficient of zero has become absolutely essential for an advanced air conditioning system. Twin split System Fits with various size room and form - Combination : Same type and capacity of indoor units - Twin kit Line up Super Digital Inverter -15 C to 43 C Outdoor temp. range when cooling* Outdoor temp. range when heating* * Digital Inverter -20 C to 15 C -15 C to 15 C *Cooling : CDB, Heating: CWB Heating operation range Quiet operation Super Digital Inverter Low-noise design. If the outdoor temperature is 30 C or less, operates at under 45 db. It s possible to automatically operate the quiet operation mode below 35 C air temperature. Digital Inverter -20 C -15 C 0 C 15 C Operating temperature range Heater operation is possible starting from an outdoor temperature of -20 C creates a comfortable space even during cold winters, while cooling operation is possible at -15 C outdoor temperature. This enables wider applications and use of the system in colder regions. Pipes can be reused Super Digital Inverter & Digital Inverter series 4 systems eqipped with R410A refrigerant can use old piping designed for old R22 or R407c refrigerant in case of replacment. Self-Clean operation-continuing high performance for energy saving This enables the 4-Way Cassette type and Ceiling type to maintain energy efficiency at the time of purchase for a long time. Self-Clean Operation - The mechanism of the wash-off Water 1. The aqua resin coating prevents dirt from sticking to the fins. Oil/ Dirt Aqua resin coating 2. The condensation water flows and washes away dirt. 3. After washing, a drying operation suppresses the propagation of mold.

6 SDI Super Digital Inverter Latest technology: Newly developed DC twin-rotary compressor, Vector-controlled inverter, Larger propeller fan, High efficiency DC fan motor, High efficiency heat-transfer and New grille design has excellent efficiency, not only under rated EER conditions, but also during partial load which is the larger part of actual operating conditions. Low-noise design: If the outdoor temperature is 30 C or less, operates at under 45 db The industry s first magnetic-action control The new structure allows a huge reduction in energy loss. The balanced magnetic-action force to rise and the rotor s weight minimized the friction laid on the axis provides excellent operation efficiency. Current model New model Magnetic action Magnetic center Stator Rotor Rotor s weight Friction loss Reducing friction loss Outdoor temperature operating range in heating (Wider heating operation) Heater operation is possible starting from an outdoor temperature of -20 C, while cooling operation is possible at -15 C outdoor temperature. Creates a comfortable space even during cold winters. Frost protection 8 C operation for frost protection is possible for the combination with Super Digital Inverter. (4-Way and Slim Duct series 4) Sub cool path Improve reliability for smooth drainage. The outdoor unit of New Super Digital Inverter is equipped with Sub cool path Preventing freeze under a heat exchanger. (Only 3HP to 6HP) Compatible with pipes up to 75 meters long Enable the outdoor unit to be installed out of sight increases installation flexibility.

7 DI Digital Inverter Extremely lightweight and compact outdoor unit Lighter than the current model by 8 kg (11%) 4 HP 5 HP 1104ATP-E 1404ATP-E 68kg previous model:76kg -8kg Remarkable energy efficiency Industry s top-class energy-saving (Max.10%UP) Small compact size chassis Reduces installation spaces and enables a more efficient use of the site. Easy to install the outdoor units on a double-decked and easy to install on a wall. Current model New model Wide-Utility function Heater operation is possible starting from an outdoor temperature of -20 C, while cooling operation is possible at -15 C and up to 46 outdoor temperature. This enables wider applications and use of the system in colder regions. Outstandingly quiet operation & save operation setting Night operation make it possible to suppress the operation sound of the outdoor unit within the time which you desire. (12dB(A) reduction)* *5HP Outdoor unit, Heating. Save operation setting is available from 50% to 100% by 1% Quiet operation & save operation setting available for 2HP, 3HP, 4HP and 5HP Note: Night operation - Necessity to set the Lite-vision plus remote controller (RBC-AMS51E) Save operation - Necessity to set the Lite-vision plus remote controller (RBC-AMS51E), RBC-AMT32E Easy and safty operation for maintenance of the outdoor unit. Inspection window makes it easy to find switch that requires operation and reduces the risk of electrical shock. 2,3 HP 4,5 HP Inspection window Cover Maintenance Switch (2 tact switches) Maintenance light (6LED)

8 DIBIG DI Big proposes competitive cost systems solution for medium size applications like Shops and Small Office buildings. Simultaneous operation of 2, 3 or up to 4 indoor unit can be installed as twin, triple and double twin systems with single outdoor unit. Compact outdoor unit Small footprint in only 0.29 m2, Compact design in size (W 900mmx D 320mm) allows opportunity for more space saving. High efficiency EER/COP* performance DI Big is equipped with a new twin-rotary DC inverter compressor with high efficiency R410A refrigerant. A new technology twin-rotary DC compressor, 100W +100W output Highly-efficient DC fan motor, propeller fan for newly developed 3-row heat exchanger. *EER / COP = 3.21 / 3.85 ( With 4-way cassette twin system of 8HP), EER / COP = 2.81 / 3.61 ( With 4-way cassette twin system of 10HP) Screw connection for larger current Wider discharge port for less pressure loss Decreasing oil discharge for reliability Compact & higher efficiency motor 1.Rare metal magnet 2.Highly concentrated & optimized winding Larger displacement cylinder (55cm3/rev) Expanded operating temperature range Air conditioning system designing is easy with DI-BIG because of its expanded operation range. Heater operation is possible starting from an outdoor temperature of -20 C, while cooling operation is possible at -15 C and up to 46 outdoor temperature. This enables wider applications and use of the system in colder regions. DI BIG Outdoor temp. range when cooling* -15 C to 46 C Outdoor temp. range when heating* -20 C to 15 C Heating operation range *Cooling : CDB, Heating: CWB DI BIG -20 C -15 C 0 C 15 C Compatible with pipes up to 70 meters long with a maximum height difference of 30 meters height

9 4-way Cassette Type Duct Type Ceiling Type High-wall Type

10 Outdoor units combinations Super Digital Inverter 1-phase model Equivalent HP 1.5HP 1.7HP 2HP 3HP 4HP 5HP Standard model SP404ATP-E SP454ATP-E SP564ATP-E SP804ATP-E SP1104AT-E SP1404AT-E Light Anti-Corrosion protection model - - - - SP1104ATZ-E SP1404ATZ-E Heavy Anti-Corrosion protection model - - SP564ATJP-E SP804ATJP-E SP1104ATZG-E SP1404ATZG-E Compact 4-Way Cassette type Single SM404MUT-E SM454MUT-E SM564MUT-E N/A N/A N/A Twin N/A N/A N/A SM404MUT-E x 2 SM564MUT-E x 2 N/N 4-Way Cassette type Triple N/A N/A N/A N/A N/A N/A Single N/A N/A SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E Twin N/A N/A N/A N/A SM564UTP-E x 2 SM804UTP-E x 2 Slim Duct type Triple N/A NA N/A N/A NA N/A Single SM404SDT-E SM454SDT-E SM564SDT-E N/A N/A N/A Twin N/A N/A N/A SM404SDT-E x 2 SM564SDT-E x 2 N/A Standard Duct type Triple N/A N/A N/A N/A N/A N/A Single SM406BT-E, SM406BTP-E SM456BT-E, SM456BTP-E SM566BT-E, SM566BTP-E SM806BT-E, SM806BTP-E SM1106BT-E, SM1106BTP-E SM1406BT-E, SM1406BTP-E Twin N/A N/A N/A SM406BT-E x 2, SM406BTP-E x 2 SM566BT-E x 2, SM566BTP-E x 2 SM806BT-E x 2, SM806BTP-E x 2 Triple N/A N/A N/A N/A N/A N/A Ceiling type Single N/A N/A SM567CTP-E SM807CTP-E SM1107CTP-E SM1407CTP-E Twin N/A N/A N/A N/A SM567CTP-E x 2 SM807CTP-E x 2 Triple N/A N/A N/A N/A N/A N/A High-Wall type Single N/A N/A SM566KRT-E SM806KRT-E N/A N/A Twin N/A N/A N/A N/A SM566KRT-E x 2 SM806KRT-E x 2 Triple N/A N/A N/A N/A N/A N/A *1 Rated conditions Cooling : Indoor air temperature 27 o C DB / 19 o C WB, Outdoor air temperature 35 o C DB Heating : Indoor air temperature 20 o C DB, Outdoor air temperature 7 o C DB / 6 o C WB *2 Sound pressure levels measured in an anechoic chamber

11 Digital Inverter 1-phase model Equivalent HP 2HP 3HP 4HP 5HP 6HP Standard model SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E Light Anti-Corrosion protection model - - - - SM1603ATZ-E Heavy Anti-Corrosion protection model SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E Compact 4-Way Cassette type Single SM564MUT-E N/A N/A N/A N/A Twin N/A N/A SM564MUT-E x 2 N/A N/A 4-Way Cassette type Triple N/A N/A N/A N/A SM564MUT-E x 3 Single SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E SM1604UTP-E Twin N/A N/A SM564UTP-E x 2 SM804UTP-E x 2 SM804UTP-E x 2 Slim Duct type Triple N/A N/A N/A N/A SM564UTP-E x 3 Single SM564SDT-E N/A N/A N/A N/A Twin N/A N/A SM564SDT-E x 2 N/A N/A Standard Duct type Triple N/A N/A N/A N/A SM564SDT-E x 3 Single SM566BT-E, SM566BTP-E SM806BT-E, SM806BTP-E SM1106BT-E, SM1106BTP-E SM1406BT-E, SM1406BTP-E SM1606BT-E, SM1606BTP-E Twin N/A N/A SM566BT-E x 2, SM566BTP-E x 2 SM806BT-E x 2, SM806BTP-E x 2 SM806BT-E x 2, SM806BTP-E x 2 Triple N/A N/A N/A N/A SM566BT-E x 3, SM566BTP-E x 3 Ceiling type Single SM567CTP-E SM807CTP-E SM1107CTP-E SM1407CTP-E SM1607CTP-E Twin N/A N/A SM567CTP-E x 2 SM807CTP-E x 2 SM807CTP-E x 2 Triple N/A N/A N/A N/A SM567CTP-E x 3 High-Wall type Single SM566KRT-E SM806KRT-E N/A N/A N/A Twin N/A N/A SM566KRT-E x 2 SM806KRT-E x 2 SM806KRT-E x 2 Triple N/A N/A N/A N/A SM566KRT-E x 3 *1 Rated conditions Cooling : Indoor air temperature 27 o C DB / 19 o C WB, Outdoor air temperature 35 o C DB Heating : Indoor air temperature 20 o C DB, Outdoor air temperature 7 o C DB / 6 o C WB *2 Sound pressure levels measured in an anechoic chamber

12 Outdoor units combinations Super Digital Inverter 3-phase model Equivalent HP 4HP 5HP 6HP Standard model SP1104AT8-E SP1404AT8-E SP1604AT8-E 50Hz Light Anti-Corrosion protection model SP1104AT8Z-E SP1404AT8Z-E SP1604AT8Z-E Heavy Anti-Corrosion protection model SP1104AT8ZG-E SP1404AT8ZG-E SP1604AT8ZG-E Standard model SP1104AT7 SP1404AT7 SP1604AT7 60Hz Light Anti-Corrosion protection model SP1104AT7Z SP1404AT7Z SP1604AT7Z Heavy Anti-Corrosion protection model SP1104AT7ZG SP1404AT7ZG SP1604AT7ZG Compact 4-Way Cassette type Single N/A N/A N/A Twin SM564MUT-E x 2 N/A N/A 4-Way Cassette type Triple N/A N/A SM564MUT-E x 3 Double twin N/A N/A N/A Single SM1104UTP-E SM1404UTP-E SM1604UTP-E Twin SM564UTP-E x 2 SM804UTP-E x 2 SM804UTP-E x 2 Slim Duct type Triple N/A N/A SM564UTP-E x 3 Double twin N/A N/A N/A Single N/A N/A N/A Twin SM564SDT-E x 2 N/A N/A Standard Duct type Triple N/A N/A SM564SDT-E x 3 Double twin N/A N/A N/A Single SM1106BT-E, SM1106BTP-E SM1406BT-E, SM1406BTP-E SM1606BT-E, SM1606BTP-E Twin SM566BT-E x 2, SM566BTP-E x 2 SM806BT-E x 2, SM806BTP-E x 2 SM806BT-E x 2, SM806BTP-E x 2 Ceiling type Triple N/A N/A SM566BT-E x 3, SM566BTP-E x 3 Double twin N/A N/A N/A Single SM1107CTP-E SM1407CTP-E SM1607CTP-E Twin SM567CTP-E x 2 SM807CTP-E x 2 SM807CTP-E x 2 High-Wall type Triple N/A N/A SM567CTP-E x 3 Double twin N/A N/A N/A Single N/A N/A N/A Twin SM566KRT-E x 2 SM806KRT-E x 2 SM806KRT-E x 2 Triple N/A N/A SM566KRT-E x 3 Double twin *1 Rated conditions Cooling : Indoor air temperature 27 o C DB / 19 o C WB, Outdoor air temperature 35 o C DB Heating : Indoor air temperature 20 o C DB, Outdoor air temperature 7 o C DB / 6 o C WB *2 Sound pressure levels measured in an anechoic chamber N/A N/A N/A

13 Digital Inverter Big 3-phase model Equivalent HP 8HP 10HP Standard model SM2244AT8-E SM2804AT8-E 50Hz Light Anti-Corrosion protection model SM2244AT8Z-E SM2804AT8Z-E Heavy Anti-Corrosion protection model SM2244AT8ZG-E SM2804AT8ZG-E Standard model SM2244AT7 SM2804AT7 60Hz Light Anti-Corrosion protection model SM2244AT7Z SM2804AT7Z Heavy Anti-Corrosion protection model SM2244AT7ZG SM2804AT7ZG Compact 4-Way Cassette type Single N/A N/A Twin N/A N/A 4-Way Cassette type Triple N/A N/A Double twin SM564MUT-E x 4 N/A Single N/A N/A Twin SM1104UTP-E x 2 SM1404UTP-E x 2 Slim Duct type Triple SM804UTP-E x 3 SM804UTP-E x 3 Double twin SM564UTP-E x 4 SM804UTP-E x 4 Single N/A N/A Twin N/A N/A Standard Duct type Triple N/A N/A Double twin SM564SDT-E x 4 N/A Single N/A N/A Twin SM1106BT-E x 2, SM1106BTP-E x 2 SM1406BT-E x 2, SM1406BTP-E x 2 Concealed Duct High Static Pressure type Triple SM806BT-E x 3, SM806BTP-E x 3 SM806BT-E x 3, SM806BTP-E x 3 Double twin SM566BT-E x 4, SM566BTP-E x 4 SM806BT-E x 4, SM806BTP-E x 4 Single SM2242DT-E * SM2802DT-E * Twin N/A N/A Ceiling type Triple N/A N/A Double twin N/A N/A Single N/A N/A Twin SM1107CTP-E x 2 SM1407CTP-E x 2 High-Wall type Triple SM807CTP-E x 3 SM807CTP-E x 3 Double twin SM567CTP-E x 4 SM807CTP-E x 4 Single N/A N/A Twin N/A N/A Triple SM806KRT-E x 3 SM806KRT-E x 3 Double twin * : RAV-SM***2DT-E can be connected to RAV-SM***4AT8-E only. *1 Rated conditions Cooling : Indoor air temperature 27 o C DB / 19 o C WB, Outdoor air temperature 35 o C DB Heating : Indoor air temperature 20 o C DB, Outdoor air temperature 7 o C DB / 6 o C WB *2 Sound pressure levels measured in an anechoic chamber SM566KRT-E x 4 SM806KRT-E x 4

14 Compact 4-Way Cassette type Perfectly fit for 600 x 600 grid system ceiling Perfect for grid system ceiling This compact unit (575 x 575 mm) fits perfectly into ceilings and matches standard architectural modules, without the need to cut ceiling tiles. RAV-SM 4MUT-E Panel Designed for simple & easy installation and maintenance The slim flat stylish panel design is only 268 mm in height even when an electrical box is located inside the unit. Easy access to electrical box is achieved by simply removing the suction grill. Easy installation is also possible using the panel adjust pocket. Use the adjust pocket function for fine adjustments after installation. The drain up height is 850 mm. Available for ceilings up to 3.5 m in height. RBC-UM11PG(W)-E 3.5m Maximum height Compact 4-Way Cassette type Super Digital Inverter and Digital Inverter Comfort Operativity Installation Inverter Allows step-less regulation of the air-conditioner s power,which reduces energy consumption and improves comfort. Long-life Filter Built-in long-life filter makes maintenance easier. Filter Sign Automatic displays on the remote controller say when to perform maintenance for the indoor unit filter. Cooler Compatible with an Outdoor Temperature of -15 C Stable cooler operation is possible when the outdoor temperature is as low as -15 C. Auto-turn Louvre Air outlet grilles move automatically to fill every corner of the room with warm or cool air.. Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room. Limit Timer Uses a 168-hour timer with three modes - ON timer, OFF timer and Repeat OFF timer. Built-in Drain Pump The built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.) Automatic Air Volume control Depending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low. Dry Gradually dehumidifies. the room to create even greater comfort..

SDI-Super Digital Inverter Outdoor unit Standard model SP404ATP-E SP454ATP-E SP564ATP-E Light Anti-Corrosion protection model - - - Heavy Anti-Corrosion protection model - - SP564ATJP-E Indoor unit SM404MUT-E SM454MUT-E SM564MUT-E Cooling* 1 Heating* 1 Capacity kw 3.6 4.0 5.0 Range, min-max kw 1.5-4.0 1.5-4.5 1.2-5.6 Power consumption kw 1.00 1.19 1.56 EER (Energy Efficiency Ratio) Capacity 100% 3.60 3.36 3.21 Capacity 80% 3.95 3.94 3.45 Capacity 50% 4.47 4.82 4.03 Capacity kw 4.0 4.5 5.6 Range, min-max kw 1.5-5.0 1.5-5.6 0.9-7.4 Power consumption kw 0.97 1.16 1.54 COP (Coefficient of Performance) Performance data Capacity 100% 4.12 3.88 3.64 Capacity 80% 4.27 4.04 3.93 Capacity 50% 4.44 4.33 4.52 15 DI-Digital Inverter Outdoor unit Physical data Indoor unit SM404MUT-E SM454MUT-E SM564MUT-E Standard air flow (H/M/L) m 3 /h 660/552/468 660/552/468 798/672/546 Sound pressure level (H/M/L) db(a) 40/36/31 40/36/31 43/39/34 Sound power level (H/M/L) db(a) 55/51/46 55/51/46 58/54/49 Main unit dimensions (H/W/D) mm 268/575/575 268/575/575 268/575/575 Weight kg 17 17 17 Panel dimensions (H/W/D) mm 27/700/700 27/700/700 27/700/700 Panel weightl kg 3 3 3 Physical data Equivalent HP 1.5HP 1.7HP 2HP 2HP Outdoor unit Standard model SM564ATP-E Light Anti-Corrosion protection model - Heavy Anti-Corrosion protection model SM564ATJP-E Indoor unit SM564MUT-E Cooling* 1 Heating* 1 Capacity kw 5.0 Range, min-max kw 1.5-5.6 Power consumption kw 1.65 EER (Energy Efficiency Ratio) Capacity 100% 3.03 Capacity 80% 3.81 Capacity 50% 4.90 Capacity kw 5.3 Range, min-max kw 1.5-6.3 Power consumption kw 1.52 COP (Coefficient of Performance) Performance data Capacity 100% 3.49 Capacity 80% 3.93 Capacity 50% 4.91 Power supply 1-phase 50Hz 230V (220-240V) / 1-phase 60Hz 220V Standard model SP404ATP-E SP454ATP-E SP564ATP-E SM564ATP-E Light Anti-Corrosion protection model - - - - Heavy Anti-Corrosion protection model RAV-) - - SP564ATJP-E SM564ATJP-E Power supply 1-phase 50Hz 230V (220 240V) 1-phase 50Hz 230V (220 240V)/ 1-phase 60Hz 220V Compressor type DC twin rotary DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø12.7 / ø6.4 ø12.7 / ø6.4 ø12.7 / ø6.4 Min. pipe length m 5 5 5 5 Max. pipe total length m 30 30 50 30 Maximum height difference m 30 30 30 30 Outer dimensions (H/W/D) mm 550/780/290 550/780/290 550/780/290 550/780/290 Weight kg 40 40 44 40 Standard air flow (Fan unit) m 3 /h 2400 2400 2400 2400 Sound pressure level, Cooling/Heating* 2 db(a) 45/47 45/47 47/48 46/48 Sound power level, Cooling/Heating db(a) 62/64 62/64 63/64 63/65 Operating range, Cooling/Heating C -15~43 / -15~15-15~43 / -20~15-15~46 / -15~15

16 RAV-SM***4MUT-E Celling bottom surface Knockout square hole φ150 φ162 105 93 70 145.5 Celling bottom surface Electric parts box 235 105 235 575 Knockout for air intake φ100 29 207 175 149 64 200 Check port ( 450) 575 320.5 Refrigerant pipe connecting port (Gas side) Refrigerant pipe connecting port (Liquid side) 70 190.5 139.5 93 105 55 Wiring connection port 21 For branch duct knockout 158 142 square hole φ150 NOTE: As ABS is used for the drain discharge port of the main unit, the vinyl chloride paste cannot be used. Use the flexible hose (Band fix) included in the package. Hanging bolt pitch 525 Ceiling open dimension 595 to 660 Panel external dimension 700 142 64 368.5 Bottom face of ceiling 177 Hanging bolt pitch 525 510 Ceiling open dimension 595 to 660 Drain standing-up size Ceiling open dimension 595 to 660 Panel external dimension 700 214 105 256 Hanging bolt M10 or W3/8 procured locally Space required for installation and servicing 97.5 42 148 φ162 Drain pipe connecting port 1000 or more 1000 or more 120 63 134 145.5 220.5 268 27 Bottom face of ceiling Ceiling panel(sold separately) 1000 or more 15 or more Obstacle Ceiling open dimension 595 to 660 Indoor unit Model RAV- A B C D SM404MUT-E, SM454MUT-E, SM564MUT-E 268 70.5 12.7 6.4 15 or more 300 Stand-up 629.5 or less Stand-up 850 or less (Unit: mm) Options TCB-FF101URE2 Ceiling panel RBC-UM11PG(W)E

17 4-Way Cassette type The wide air flow in all direction Multi-louver individual control RAV-SM 4UTP-E Panel Wide flow louver type Individual louver control enables airflow to be chosen according to user preferences. The angles of each louver can be set individually in 3 different choices of swing patterns; Standard swing, Diagonally opposite swing and Turn-around swing (1) Standard swing (2) Diagonally opposite swing (3) Turn-around swing RBC-U31PGP(W)-E New Long-life pre-filter A new long-life pre-filter has a surface 1.5 times of current filters to improve Dust-collection performance. RBC-U31PGP(WS)-E Straight flow louver type Built-in condensate drain pump Easy installation RBC-U31PGS(W)-E* 300mm or less 850mm or less Light weight unit (24kg at 5HP) Easy panel installation, The panel is attached using the bolt that is already installed on the indoor unit. 210mm RBC-U31PGS(WS)-E* *European market only 4-Way Cassette type Super Digital Inverter and Digital Inverter Comfort Operativity Installation Inverter Allows step-less regulation of the air-conditioner s power,which reduces energy consumption and improves comfort. Long-life Filter Built-in long-life filter makes maintenance easier. Filter Sign Automatic displays on the remote controller say when to perform maintenance for the indoor unit filter. Cooler Compatible with an Outdoor Temperature of -15 C Stable cooler operation is possible when the outdoor temperature is as low as -15 C. Individual Louvre control Enables airflows to be chosen according to user preferences.. Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room. Limit Timer Uses a 168-hour timer with three modes - ON timer, OFF timer and Repeat OFF timer. Built-in Drain Pump The built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.) Auto-turn Louvre Air outlet grilles move automatically to fill every corner of the room with warm or cool air. Dry Gradually dehumidifies the room to create even greater comfort.. Automatic Air Volume control Depending on the difference between the room temperature and the set temperature, switches automatically between High, Low and Very Low..

18 SDI-Super Digital Inverter Out door unit Performance data Standard model SP564ATP-E SP804ATP-E SP1104AT-E SP1404AT-E Light Anti-Corrosion protection model - - SP1104ATZ-E SP1404ATZ-E Heavy Anti-Corrosion protection model SP564ATJP-E SP804ATJP-E SP1104ATZG-E SP1404ATZG-E Indoor unit SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E Capacity kw 5.3 7.1 10.0 12.5 Range, min-max kw 1.2-5.6 1.9-8.0 2.6-12.0 2.6-14.0 Cooling* 1 Power consumption kw 1.47 1.86 2.21 3.16 EER (Energy Efficiency Ratio) Capacity 100% 3.61 3.82 4.52 3.96 Capacity 80% 4.25 4.40 5.31 4.64 Capacity 50% 5.56 5.56 6.49 5.67 Capacity kw 5.6 8.0 11.2 14.0 Range, min-max kw 0.9-8.1 1.3-11.3 2.4-13.0 2.4-16.5 Heating* 1 Power consumption kw 1.21 1.91 2.34 3.21 COP (Coefficient of Performance) Capacity 100% 4.63 4.19 4.79 4.36 Capacity 80% 5.15 4.71 5.01 4.57 Capacity 50% 5.96 5.56 5.38 4.90 Power supply 1-phase 50Hz 230V (220 240V) / 1-phase 60Hz 220V DI-Digital Inverter Out door unit Performance data Standard model SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E Light Anti-Corrosion protection model - - - - SM1603ATZ-E Heavy Anti-Corrosion protection model SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E Indoor unit SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E SM1604UTP-E Capacity kw 5.0 6.7 10.0 12.0 14.0 Range, min-max kw 1.5-5.6 1.5-8.0 3.0-11.2 3.0-13.2 3.0-16.0 Cooling* 1 Power consumption kw 1.56 2.22 3.02 4.29 4.49 EER (Energy Efficiency Ratio) Capacity 100% 3.21 3.02 3.31 2.80 3.12 Capacity 80% 4.00 3.77 4.08 3.53 3.98 Capacity 50% 5.21 5.49 5.10 5.00 4.86 Heating* 1 Power supply Physical data Indoor unit SM564UTP-E SM804UTP-E SM1104UTP-E SM1404UTP-E SM1604UTP-E Standard air flow (H/M/L) m 3 /h 1050/870/780 1230/960/810 2010/1440/1170 2100/1440/1230 2130/1500/1260 Sound pressure level (H/M/L) db(a) 32/29/28 35/31/28 43/38/33 44/38/34 45/40/36 Sound power level (H/M/L) db(a) 47/44/43 50/46/43 58/53/48 59/53/49 60/55/51 Main unit dimensions (H/W/D) mm 256/840/840 256/840/840 319/840/840 319/840/840 319/840/840 Weight kg 20 20 24 24 24 Panel dimensions (H/W/D) mm 30/950/950 30/950/950 30/950/950 30/950/950 30/950/950 Panel weight kg 4.2 4.2 4.2 4.2 4.2 Physical data Equivalent HP 2HP 3HP 4HP 5HP 2HP 3HP 4HP 5HP 6HP Out door unit Capacity kw 5.3 7.7 11.2 12.8 16.0 Range, min-max kw 1.5-6.3 1.5-9.0 3.0-13.0 3.0-16.0 3.0-18.0 Power consumption kw 1.36 2.13 2.93 3.40 4.43 COP (Coefficient of Performance) Capacity 100% 3.90 3.62 3.82 3.76 3.61 Capacity 80% 4.37 4.22 4.23 4.30 4.59 Capacity 50% 5.41 5.50 5.19 5.12 4.91 1-phase 50Hz 230V (220 240V) / 1-phase 60Hz 220V 1-phase 50Hz 230V (220-240V) Standard model SP564ATP-E SP804ATP-E SP1104AT-E SP1404AT-E SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E Light Anti-Corrosion protection model - - SP1104ATZ-E SP1404ATZ-E - - - - SM1603ATZ-E Heavy Anti-Corrosion protection model SP564ATJP-E SP804ATJP-E SP1104ATZG-E SP1404ATZG-E SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E Power supply 1-phase 50Hz 230V (220 240V) 1-phase 50Hz 230V (220 240V) / 1-phase 60Hz 220V Compressor type DC twin rotary DC twin rotary 1-phase 50Hz 230V (220 240V) Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 ø12.7 / ø6.4 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 Standard / Min. pipe length m 7.5 / 5 7.5 / 5 7.5 / 3 7.5 / 3 7.5 / 5 7.5 / 5 7.5 / 5 7.5 / 5 7.5 / 5 Max. pipe total length m 50 50 75 75 30 30 50 50 50 Maximum height difference m 30 30 30 30 30 30 30 30 30 Outer dimensions (H/W/D) mm 550/780/290 890/900/320 1340/900/320 1340/900/320 550/780/290 550/780/290 890/900/320 890/900/320 1340/900/320 Weight kg 44 66 93 93 40 44 68 68 99 Standard air flow (Fan unit) m 3 /h 2400 3000 6060 6180 2400 2700 4080 4200 6180 Sound pressure level, Cooling/Heating * 2 db(a) 47/48 48/49 49/50 51/52 46/48 48/52 53/54 54/55 51/53 Sound power level, Cooling/Heating db(a) 63/64 64/65 66/67 68/69 63/65 65/69 70/71 70/71 68/70 Operating range, Cooling/Heating C -15~43 / -20~15-15~46 / -15~15-15~43 / -15~15

19 RAV-SM***4UTP-E Electric parts box Celling Ceiling bottom surface 187 155 Knockoutfor freshairintake intake φ100 Z Zview 61 28.5 32 57 64 Z Hanging bolt pitch Panel external dimension B Hanging bolt pitch Panel external dimension Hanging bolt M10 or (procured by locally) Drain pipe connection port (Material: PP) For branch duct Knockout square hole 860to910 910 Ceiling open dimension ension 860 910 Ceiling open dimension 860 to910 ension Refrigerant pipe connecting port (Liquid side) Refrigerant pipe connecting port (Gas ide) C D 300orless A Bottom faceofceiling Ceiling Stand-up 661orless Stand-up 850orless Bottom face of ceiling Ceiling Ceiling panel (sold separately) Drain Drain standing-up size For branch duct Knockout square hole Spacerequiredforinstallation installation and servicing and servicing 15 or more Bottom face of ceiling 1000 ormore 1000 orm more 15 or more m ore Take-in port of wiring Model RAV- A B SM564UTP-E SM804UTP-E 256 256 74 74 SM1104UTP-E, SM1404UTP-E, SM1604UTP-E 319 137 C D 12.7 6.4 15.9 9.5 15.9 9.5 1000 1000 or or more more (Unit:mm) Options TCB-FF101URE2 TCB-GFC1602UE Fresh air inlet box TCB-GB1602UE Air discharge direction kit TCB-BC1602UE Spacer for height adjustment Spacer for height adjustment TCB-SP1602UE Ceiling panel RBC-U31PGP(W)-E RBC-U31PGP(WS)-E Air discharge parts A Packing A Air discharge parts B Packing B Refrigerant piping side Drain piping side Air discharge parts C Packing B Air inlet grille

20 SDI-Super Digital Inverter Out door unit Standard model SP1104AT8-E SP1404AT8-E SP1604AT8-E 50Hz Light Anti-Corrosion protection model SP1104AT8Z-E SP1404AT8Z-E SP1604AT8Z-E 60Hz Heavy Anti-Corrosion protection model SP1104AT8ZG-E SP1404AT8ZG-E SP1604AT8ZG-E Standard model SP1104AT7 SP1404AT7 SP1604AT7 Light Anti-Corrosion protection model SP1104AT7Z SP1404AT7Z SP1604AT7Z Heavy Anti-Corrosion protection model SP1104AT7ZG SP1404AT7ZG SP1604AT7ZG Indoor unit SM1104UTP-E SM1404UTP-E SM1604UTP-E Cooling* 1 Heating* 1 Power supply Capacity kw 10.0 12.5 14.0 Range, min-max kw 2.6-12.0 2.6-14.0 2.6-16.0 Power consumption kw 2.37 3.46 4.49 EER (Energy Efficiency Ratio) Capacity 100% 4.22 3.61 3.12 Capacity 80% 4.79 4.10 3.53 Capacity 50% 5.88 5.43 5.07 Capacity kw 11.2 14.0 16.0 Range, min-max kw 2.4-15.6 2.4-18.0 2.4-19.0 Power consumption kw 2.42 3.42 4.30 COP (Coefficient of Performance) Performance data Capacity 100% 4.63 4.09 3.72 Capacity 80% 5.09 4.50 4.09 Capacity 50% 6.09 5.47 5.33 3-phase 50Hz 400V (380-415V) / 3-phase 60Hz 380V Physical data Indoor unit SM1104UTP-E SM1404UTP-E SM1604UTP-E Standard air flow (H/M/L) m 3 /h 2010/1440/1170 2100/1440/1230 2130/1500/1260 Sound pressure level (H/M/L) db(a) 43/38/33 44/38/34 45/40/36 Sound power level (H/M/L) db(a) 58/53/48 59/53/49 60/55/51 Main unit dimensions (H/W/D) mm 319/840/840 319/840/840 319/840/840 Weight kg 24 24 24 Panel dimensions (H/W/D) mm 30/950/950 30/950/950 30/950/950 Panel weightl kg 4.2 4.2 4.2 Physical data Equivalent HP 4HP 5HP 6HP Out door unit 50Hz 60Hz Power supply Compressor type Standard model SP1104AT8-E SP1404AT8-E SP1604AT8-E Light Anti-Corrosion protection model SP1104AT8Z-E SP1404AT8Z-E SP1604AT8Z-E Heavy Anti-Corrosion protection model SP1104AT8ZG-E SP1404AT8ZG-E SP1604AT8ZG-E Standard model SP1104AT7 SP1404AT7 SP1604AT7 Light Anti-Corrosion protection model SP1104AT7Z SP1404AT7Z SP1604AT7Z Heavy Anti-Corrosion protection model SP1104AT7ZG SP1404AT7ZG SP1604AT7ZG 3-phase 50Hz 400V (380-415V) / 3-phase 60Hz 380V DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 Standard / Min. pipe length m 7.5 / 3 7.5 / 3 7.5 / 3 Max. pipe total length m 75 75 75 Maximum height difference m 30 30 30 Outer dimensions (H/W/D) mm 1340/900/320 1340/900/320 1340/900/320 Weight kg 95 95 95 Standard air flow (Fan unit) m 3 /h 6060 6180 6180 Sound pressure level, Cooling/Heating* 2 db(a) 49/50 51/52 51/53 Sound power level, Cooling/Heating db(a) 66/67 68/69 68/70 Operating range, Cooling/Heating C -15~46 / -20~15

21 Slim Duct type Slim design for greater application flexibility Functional design Only 210 mm in height for greater application flexibility. RAV-SM 4SDT-E 4-step static pressure setup. Concealed installation within a ceiling void. Auxiliary fresh air intake available. 210mm 210mm Slim & quiet Quiet, powerful operation. Perfect comfort throughout the room and can be used with any style of air diffuser. Slim Duct type Super Digital Inverter and Digital Inverter Comfort Operativity Installation Inverter Allows step-less regulation of the air-conditioner s power,which reduces energy consumption and improves comfort. Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room. Filter Sign Automatic displays on the remote controller say when to perform maintenance for the indoor unit filter. Cooler Compatible with an Outdoor Temperature of -15 C Stable cooler operation is possible when the outdoor temperature is as low as -15 C. Automatic Air Volume control Depending on the difference between the room temperature and the set temperature, switches automatically between. High, Low and Very Low. Dry Gradually dehumidifies the room to create even greater comfort. Limit Timer Uses a 168-hour timer with three modes - ON timer, OFF timer and Repeat OFF timer. Built-in Drain Pump The built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.) Long-life Filter Built-in long-life filter makes maintenance easier...

22 SDI-Super Digital Inverter Outdoor unit DI-Digital Inverter Outdoor unit Standard model SM564ATP-E Light Anti-Corrosion protection model - Heavy Anti-Corrosion protection model SM564ATJP-E Indoor unit SM564SDT-E Cooling* 1 Heating* 1 Standard model SP404ATP-E SP454ATP-E SP564ATP-E Light Anti-Corrosion protection model - - - Heavy Anti-Corrosion protection model - - SP564ATJP-E Indoor unit SM404SDT-E SM454SDT-E SM564SDT-E Cooling* 1 Heating* 1 Power supply Capacity kw 3.6 4.0 5.0 Range, min-max kw 1.5-4.0 1.5-4.5 1.2-5.6 Power consumption kw 1.03 1.20 1.56 EER (Energy Efficiency Ratio) Capacity kw 5.0 Range, min-max kw 1.5-5.6 Power consumption kw 1.91 EER (Energy Efficiency Ratio) Capacity 100% 2.62 Capacity 80% 3.28 Capacity 50% 4.24 Capacity kw 5.3 Range, min-max kw 1.5-6.3 Power consumption kw 1.50 COP (Coefficient of Performance) Capacity 100% 3.50 3.33 3.21 Capacity 80% 3.83 3.91 3.45 Capacity 50% 4.34 4.77 4.03 Capacity kw 4.0 4.5 5.6 Range, min-max kw 1.5-5.0 1.5-5.6 0.9-7.4 Power consumption kw 1.00 1.15 1.44 COP (Coefficient of Performance) Performance data Capacity 100% 3.53 Capacity 80% 3.96 Capacity 50% 4.82 Performance data Capacity 100% 4.00 3.91 3.89 Capacity 80% 4.10 4.09 4.11 Capacity 50% 4.35 4.41 4.52 1-phase 50Hz 230V (220 240V) Power supply 1-phase 50Hz 230V (220 240V) / 1-phase 60Hz 220V Physical data Indoor unit SM404SDT-E SM454SDT-E SM564SDT-E Standard air flow (H/M/L) m 3 /h 690/600/522 690/600/522 780/678/582 External static pressure-standard (Upper-Lower) Pa 5-15-30-45 5-15-30-45 4-14-29-44 Sound pressure level-under air inlet db(a) 39/36/33 39/36/33 45/40/36 Sound pressure level-back air inlet db(a) 30/28/26 30/28/26 33/31/28 Sound power level (H/M/L) db(a) 54/51/48 54/51/48 60/55/54 Dimensions (H/W/D) mm 210/845/645 210/845/645 210/845/645 Weightl kg 22 22 22 Physical data Equivalent HP 1.5HP 1.7HP 2HP 2HP Standard model SP404ATP-E SP454ATP-E SP564ATP-E SM564ATP-E Outdoor unit Light Anti-Corrosion protection model - - - - Heavy Anti-Corrosion protection model RAV-) - - SP564ATJP-E SM564ATJP-E Power supply 1-phase 50Hz 230V (220 240V) 1-phase 50Hz 230V (220 240V) / 1-phase 60Hz 220V Compressor type DC twin rotary DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø12.7 / ø6.4 ø12.7 / ø6.4 ø12.7 / ø6.4 Standard / Min. pipe length m 7.5 / 5 7.5 / 5 7.5 / 5 7.5 / 5 Max. pipe total length m 30 30 50 30 Maximum height difference m 30 30 30 30 Outer dimensions (H/W/D) mm 550/780/290 550/780/290 550/780/290 550/780/290 Weight kg 40 40 44 40 Standard air flow (Fan unit) m 3 /h 2400 2400 2400 2400 Sound pressure level, Cooling/Heating* 2 db(a) 45/47 45/47 47/48 46/48 Sound power level, Cooling/Heating db(a) 62/64 62/64 63/64 63/65 Operating range, Cooling/Heating C -15~43 / -15~15-15~43 / -20~15-15~46 / -15~15

4-Ø4 23 RAV-SM**4SDT-E Ø92 80 168 21 (inside) 21 168 19 20 21 845 803 (inside) 21 511 67 57 645 210 103 31 Refrigerant piping 120 67 40 359 372 422 502 80 59 805 910 33 163 Fresh air inlet (knock-out hole) Hung-up plate Drain-up port (Unit:mm) Options TCB-FF101URE2

24 Standard Duct type Wide range of application opportunities Compact sizing Compact size especially in height (275 mm), new slimmer chassis offers wide range of installation opportunities to customer. RAV-SM 6BT-E RAV-SM 6BTP-E 275mm 275mm High static pressure Spigot shaped flange External static pressure can be raised as high as 120 Pa, so that all areas of the room can be reached for even temperature distribution, no matter how complex the layout. Built-in High-lift drain pump TCB-SF56C6BEP The flexible piping layout is made possible by an optionally available drain-pump kit that raises the drain piping up to 29 cm from the drain port. Flexible duct is accessible, Allows complete design flexibility TCB-SF80C6BEP TCB-SF160C6BEP Polygonal rooms Narrow rooms Rooms with fixtures and obstacles New spigot shaped flange as new accessories New spigot shaped flange has higher static pressure with optimized design, the static pressure drops only 20Pa from rectangle flange states. Maximum Static pressure will be 100Pa* with all models. (*static pressure with filter which included in, and intake from back ward) Standard Duct type Super Digital Inverter and Digital Inverter Comfort Operativity Installation Inverter Allows step-less regulation of the air-conditioner s power,which reduces energy consumption and improves comfort. Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room. Filter Sign Automatic displays on the remote controller say when to perform maintenance for the indoor unit filter. Cooler Compatible with an Outdoor Temperature of -15 C Stable cooler operation is possible when the outdoor temperature is as low as -15 C. Automatic Air Volume control Depending on the difference between the room temperature and the set temperature, switches automatically between. High, Low and Very Low. Dry Gradually dehumidifies the room to create even greater comfort. Limit Timer Uses a 168-hour timer with three modes - ON timer, OFF timer and Repeat OFF timer. Built-in Drain Pump The built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.) Long-life Filter Built-in long-life filter makes maintenance easier...

SDI-Super Digital Inverter Out door unit Indoor unit Standard model SP404ATP-E SP454ATP-E SP564ATP-E SP804ATP-E SP1104AT-E SP1404AT-E Light Anti-Corrosion protection model - - - - SP1104ATZ-E SP1404ATZ-E Heavy Anti-Corrosion protection model - - SP564ATJP-E SP804ATJP-E SP1104ATZG-E SP1404ATZG-E SM406BT-E, SM406BTP-E SM456BT-E, SM456BTP-E SM566BT-E, SM566BTP-E SM806BT-E, SM806BTP-E SM1106BT-E, SM1106BTP-E Performance data SM1406BT-E, SM1406BTP-E Capacity kw 3.6 4.0 5.0 7.1 10.0 12.5 25 Range, min-max kw 1.5-4.0 1.5-4.5 1.2-5.6 1.9-8.0 2.6-12.0 2.6-14.0 Cooling* 1 Power consumption kw 1.07 1.23 1.56 2.06 2.64 3.83 EER (Energy Efficiency Ratio) Capacity 100% 3.38 3.24 3.21 3.45 3.79 3.26 Capacity 80% 3.69 3.81 3.23 3.89 4.44 3.83 Capacity 50% 4.19 4.65 3.47 4.93 5.43 4.66 Capacity kw 4.0 4.5 5.6 8.0 11.2 14.0 Range, min-max kw 1.5-5.0 1.5-5.6 0.9-7.4 1.3-10.6 2.4-13.0 2.4-16.5 Heating* 1 Power consumption kw 1.04 1.24 1.55 2.21 2.77 3.67 COP (Coefficient of Performance) Capacity 100% 3.84 3.63 3.61 3.62 4.04 3.81 Capacity 80% 3.95 3.79 3.80 3.79 4.25 4.00 Capacity 50% 4.17 4.09 4.12 4.08 4.55 4.29 Power supply DI-Digital Inverter Out door unit Indoor unit Standard model SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E Light Anti-Corrosion protection model - - - - SM1603ATZ-E Heavy Anti-Corrosion protection model SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E SM566BT-E, SM566BTP-E SM806BT-E, SM806BTP-E 1-phase 50Hz 230V (220 240V) / 1-phase 60Hz 220V SM1106BT-E, SM1106BTP-E* SM1406BT-E, SM1406BTP-E Performance data SM1606BT-E, SM1606BTP-E Capacity kw 5.0 6.7 10.0 12.1 14.0 Range, min-max kw 1.5-5.6 1.5-7.4 3.0-11.2 3.0-13.2 3.0-16.0 Cooling* 1 Power consumption kw 1.83 2.38 3.14 4.42 5.13 EER (Energy Efficiency Ratio) Capacity 100% 2.73 2.82 3.18 2.74 2.73 Capacity 80% 3.42 3.53 3.92 3.46 3.48 Capacity 50% 4.39 5.08 4.90 4.92 4.24 Heating* 1 Power supply Physical data Indoor unit Physical data Equivalent HP 1.5HP 1.7HP 2HP 3HP 4HP 5HP 2HP 3HP 4HP 5HP 6HP Out door unit Capacity kw 5.3 7.7 11.2 12.8 16.0 Range, min-max kw 1.5-6.3 1.5-9.0 3.0-12.5 3.0-16.0 3.0-18.0 Power consumption kw 1.62 2.32 2.99 3.55 4.69 COP (Coefficient of Performance) Capacity 100% 3.27 3.32 3.75 3.61 3.41 Capacity 80% 3.69 3.87 4.15 4.11 4.04 Capacity 50% 4.57 5.07 5.09 4.89 4.32 SM406BT-E, SM406BTP-E 1-phase 50Hz 230V (220 240V) / 1-phase 60Hz 220V SM456BT-E, SM456BTP-E SM566BT-E, SM566BTP-E SM806BT-E, SM806BTP-E 1-phase 50Hz 230V (220 240V) SM1106BT-E, SM1106BTP-E SM1406BT-E, SM1406BTP-E SM1606BT-E, SM1606BTP-E Standard air flow (H/M/L) m 3 /h 798/630/480 798/630/480 798/630/480 1200/930/720 2100/1650/1260 2100/1650/1260 2100/1650/1260 External static pressure (factory setting) Pa 30 30 30 30 50 50 50 External static pressure-standard (Upper-Lower) Pa 30(120-30) 30(120-30) 50(120-30) Sound pressure level (H/M/L) db(a) 33/29/25 33/29/25 33/29/25 34/30/26 40/36/33 40/36/33 40/36/33 Sound power level (H/M/L) db(a) 48/44/40 48/44/40 48/44/40 49/45/41 55/51/48 55/51/48 55/51/48 Dimensions (H/W/D) mm 275/700/750 275/700/750 275/700/750 275/1000/750 275/1400/750 275/1400/750 275/1400/750 Weight kg 23 23 23 30 40 40 40 Standard model SP404ATP-E SP454ATP-E SP564ATP-E SP804ATP-E SP1104AT-E SP1404AT-E SM564ATP-E SM804ATP-E SM1104ATP-E SM1404ATP-E SM1603AT-E Light Anti-Corrosion protection model - - - - SP1104ATZ-E SP1404ATZ-E - - - - SM1603ATZ-E Heavy Anti-Corrosion protection model - - SP564ATJP-E SP804ATJP-E SP1104ATZG-E SP1404ATZG-E SM564ATJP-E SM804ATJP-E SM1104ATJP-E SM1404ATJP-E SM1603ATZG-E Power supply 1-phase 50Hz 230V (220 240V) 1-phase 50Hz 230V (220 240V) / 1-phase 60Hz 220V Compressor type DC twin rotary DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø12.7 / ø6.4 ø15.9 / ø9.5 ø12.7 / ø6.4 ø15.9 / ø9.5 Standard / Min. pipe length m 7.5 / 5 7.5 / 5 7.5 / 3 7.5 / 5 Max. pipe total length m 30 50 50 75 30 50 Maximum height difference m 30 30 30 30 30 30 1-phase 50Hz 230V (220 240V) Outer dimensions (H/W/D) mm 550/780/290 890/900/320 1340/900/320 550/780/290 890/900/320 1340/900/320 Weight kg 40 44 66 93 40 44 68 99 Standard air flow (Fan unit) m 3 /h 2400 3000 6060 6180 2400 2700 4080 4200 6180 Sound pressure level, Cooling/Heating* 2 db(a) 45/47 45/47 47/48 48/49 49/50 51/52 46/48 48/52 53/54 54/55 51/53 Sound power level, Cooling/Heating db(a) 62/64 62/64 63/64 64/65 66/67 68/69 63/65 65/69 70/71 70/71 68/70 Operating range, Cooling/Heating C -15~43 / -15~15-15~43 / -20~15-15~46 / -15~15-15~43 / -15~15

26 RAV-SM***6BT(P)-E Space required for installation and servicing Ceiling 100 or more Air outlet 25 25 D 700 or more Service door (Ceiling opening) Floor surface Refrigerant pipe connecting port (Liquid side) G 108 Refrigerant pipe connecting port (Gas side) F 355 345 117.5 5 or more anging Hanging olt bolt pitc pitcha A Unit Unit e ternal external dimensionb B ternal External dimensions of flangec C 2500 or more 275 70 or more E ( E for maintenance of air filter ) Flexible Fle i le drain hose ose (Accessory) (Accessor ) Drain pipe connecting port 1 100 1/100 or or more downward do n ard At the t e time of natural drainage 233 570 650 50 20 37 233 232 20 Wires ire s dra ing out drawing-out port 18 Under Under air air intake inta e typet pe Model RAV- SM406BT(P)*-E, SM406BT(P)-E, SM456BT(P)-E, SM456BT(P)*-E, SM566BT(P)-E SM566BT(P)*-E SM806BT(P)*-E SM806BT(P)-E SM1106BT(P)*-E, SM1106BT(P)-E, SM1406BT(P)-E, SM1406BT(P)*-E, SM1606BT(P)-E SM1606BT(P)*-E A B C D 765 1065 1465 700 1000 1400 640 940 1340 750 1050 1450 E 700 500 700 F G 12.7 6.4 12.7 6.4 15.9 9.5 D (Unit:mm) Options TCB-SF56C6BE TCB-SF80C6BE TCB-SF160C6BE TCB-SF56C6BE TCB-SF80C6BE Model TCB-SF56C6BE TCB-SF80C6BE TCB-SF160C6BE Compatible SM406BT(P)-E, SM406BT(P)*-E, SM456BT(P)-E, SM456BT(P)*-E, SM566BT(P)-E SM566BT(P)*-E SM806BT(P)-E SM806BT(P)*-E SM1106BT(P)-E, SM1106BT(P)*-E, SM1406BT(P)-E, SM1406BT(P)*-E SM1606BT(P)-E TCB-SF160C6BE (Unit:mm)

27 SDI-Super Digital Inverter Out door unit Standard model SP1104AT8-E SP1404AT8-E SP1604AT8-E 50Hz Light Anti-Corrosion protection model SP1104AT8Z-E SP1404AT8Z-E SP1604AT8Z-E 60Hz Indoor unit Cooling* 1 Heating* 1 Power supply Heavy Anti-Corrosion protection model SP1104AT8ZG-E SP1404AT8ZG-E SP1604AT8ZG-E Standard model SP1104AT7 SP1404AT7 SP1604AT7 Light Anti-Corrosion protection model SP1104AT7Z SP1404AT7Z SP1604AT7Z Heavy Anti-Corrosion protection model SP1104AT7ZG SP1404AT7ZG SP1604AT7ZG SM1106BT-E, SM1106BTP-E SM1406BT-E, SM1406BTP-E SM1606BT-E, SM1606BTP-E Capacity kw 10.0 12.5 14.0 Range, min-max kw 2.6-12.0 2.6-14.0 2.6-16.0 Power consumption kw 2.64 3.86 4.65 EER (Energy Efficiency Ratio) Capacity 100% 3.79 3.24 3.01 Capacity 80% 4.30 3.68 3.41 Capacity 50% 5.71 4.88 4.90 Capacity kw 11.2 14.0 16.0 Range, min-max kw 2.4-15.6 2.4-18.0 2.4-19.0 Power consumption kw 2.77 3.67 4.60 COP (Coefficient of Performance) Performance data Capacity 100% 4.04 3.81 3.48 Capacity 80% 4.44 4.18 3.82 Capacity 50% 5.33 5.09 4.98 3-phase 50Hz 400V (380-415V) / 3-phase 60Hz 380V Physical data Indoor unit SM1106BT-E, SM1106BTP-E SM1406BT-E, SM1406BTP-E SM1606BT-E, SM1606BTP-E Standard air flow (H/M/L) m 3 /h 2100/1650/1260 2100/1650/1260 2100/1650/1260 External static pressure (factory setting) Pa 50 50 50 External static pressure Pa 30-40-50-65-80-100-120 (7 steps) Sound pressure level (H/M/L) db(a) 40/36/33 40/36/33 40/36/33 Sound power level (H/M/L) db(a) 55/51/48 55/51/48 55/51/48 Dimensions (H/W/D) mm 275/1400/750 275/1400/750 275/1400/750 Weight kg 40 40 40 Physical data Equivalent HP 4HP 5HP 6HP Out door unit 50Hz 60Hz Power supply Compressor type Standard model SP1104AT8-E SP1404AT8-E SP1604AT8-E Light Anti-Corrosion protection model SP1104AT8Z-E SP1404AT8Z-E SP1604AT8Z-E Heavy Anti-Corrosion protection model SP1104AT8ZG-E SP1404AT8ZG-E SP1604AT8ZG-E Standard model SP1104AT7 SP1404AT7 SP1604AT7 Light Anti-Corrosion protection model SP1104AT7Z SP1404AT7Z SP1604AT7Z Heavy Anti-Corrosion protection model SP1104AT7ZG SP1404AT7ZG SP1604AT7ZG 3-phase 50Hz 400V (380-415V) / 3-phase 60Hz 380V DC twin rotary Connecting pipe dia., Gas/Liquid side mm ø15.9 / ø9.5 ø15.9 / ø9.5 ø15.9 / ø9.5 Standard / Min. pipe length m 7.5 / 3 7.5 / 3 7.5 / 3 Max. pipe total length m 75 75 75 Maximum height difference m 30 30 30 Outer dimensions (H/W/D) mm 1340/900/320 1340/900/320 1340/900/320 Weight kg 95 95 95 Standard air flow (Fan unit) m 3 /h 6060 6180 6180 Sound pressure level, Cooling/Heating* 2 db(a) 49/50 51/52 51/53 Sound power level, Cooling/Heating db(a) 66/67 68/69 68/70 Operating range, Cooling/Heating C -15~46 / -20~15

28 Concealed Duct High Static Pressure type Satisfies all your design needs Design flexibility Compatible with external static pressures up to 196 Pa. RAV-SM 2DT-E 3-steps-switchable static pressure Low Middle High External static pressure (Pa) 68.6 137.0 196.0 Large air volume, Duct high static pressure type is most suitable for the large rooms. Long-life filters fitted as standard. Can be equipped with the following options: high-efficiency filter (65, 90) drain pump kit. *Factory setting : 137Pa Construction characteristics The flexible duct is accessible. Constant temperature setting is possible in large rooms or factories. Easy service and installation. Enable to maintain the blower section from unit side for maintenance and repair. Drain pump kit is available as optional parts up to 330 mm from unit bottom. Enable to select auto restart operation (set from wired remote controller) Concealed Duct High Static Pressure type DI BIG Comfort Operativity Installation Inverter Allows step-less regulation of the air-conditioner s power,which reduces energy consumption and improves comfort. Hot Start When using the heater for preheating or defrosting, stops the indoor fan to prevent cold air from being blown into the room. Filter Sign Automatic displays on the remote controller say when to perform maintenance for the indoor unit filter. Cooler Compatible with an Outdoor Temperature of -15 C Stable cooler operation is possible when the outdoor temperature is as low as -15 C. Automatic Air Volume control Depending on the difference between the room temperature and the set temperature, switches automatically between. High, Low and Very Low. Dry Gradually dehumidifies the room to create even greater comfort. Limit Timer Uses a 168-hour timer with three modes - ON timer, OFF timer and Repeat OFF timer. Built-in Drain Pump The built-in drain pump makes draining easier. (In the ceiling cassette type, it is built in to the main unit.) Long-life Filter Built-in long-life filter makes maintenance easier...