Air-conditioning and climate-control technology



Similar documents
EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

HEATING, VENTILATION & AIR CONDITIONING

Top Technology for Industry, Agriculture, Business and Communities

How To Get A Passive House

Climotion ensures a better climate. Better comfort and lower costs in all buildings. Bosch Energy and Building Solutions

Refrigeration Compressed Air Dryer Buran Ultrapulse

Bring the fresh in. Dedicated Outside Air Systems

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

LG Electronics AE Company, Commercial Air Conditioning

Crowne Plaza Copenhagen Towers The world s greenest hotel

INFO HTK. Hybrid dry cooler. The reference for hybrid dry cooling ,000 kw

KNX for building and room automation simple and efficient

System solution for data centres

ROTEX gas hybrid heat pump. A strong team.

AIR DEHUMIDIFYING Condensation drying for industry and trade

air conditioners how to choose a cooling system

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

AQUACIAT2 HYBRID THE COMPACT DUAL-ENERGY SOLUTION HEAT PUMP & GAS BOILER. Cooling and heating capacities of 45 to 80 kw AVAILABLE 2 ND QUARTER OF 2014

Air-water systems for efficient air conditioning

Pool Dehumidification Basics

AIR CONDITIONING - ENERGY CONSUMPTION AND ENVIRONMENTAL QUALITY

Vitocaldens 222-F Compact Gas-Hybrid appliance

AdSORPTION CHILLER NAK

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

Screw Compressors ESM Fixed Speed & VS Variable Speed

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Half the cost Half the carbon

Using Time-of-Day Scheduling To Save Energy

Year project completed or estimated year of completion: October 2014

HVAC Processes. Lecture 7

Small-Scale Solar Heating and Cooling Systems

Important Safeguards

Lesson 36 Selection Of Air Conditioning Systems

SWIMMING POOL HEAT PUMP

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

IMMERSION MANAGEMENT SERVICE KG

Controlling Wrap-Around Heat Pipes for Systems with Strict Space Humidity Requirements. By Michael O. Davis, PE, November 2015

Air Diffusers for direct conditioning Type WDA/WDB

york air-conditioning products Residential & VRF News 2015

You make dreams a reality. We provide the efficient Air-Conditioning.

Material test chamber with mechanical convection

Samsung Room Air Conditioning

Defining Energy Efficiency

Incubator with mechanical convection

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Energy savings in the residential area are essential in

Heat-Pipe Heat Exchanger

Infrastructure & Cities Sector

How To Make Your House Breathe

Portable Compressors MOBILAIR M122 With the world-renowned SIGMA PROFILE Free air delivery 11.1 m³/min.

Sustainable construction criteria to evaluate the thermal indoor climate - further development of the BNB assessment tool and practical implementation

DAikin Altherma low temperature heat pump. end user leaflet

CoolTeg Plus Chilled Water (CW) version: AC-TCW

saving energy in comfort Factsheet Recair Enthalpy

More efficiency in hotels with HVAC, lighting and security

Dehumidifier D 850E. - Instruction manual version 02

L-ENZ The dryer for bulk solids

Smart Cities. Integrated approach for innovative technologies. 2nd Annual Conference of the ETP on. Budapest, 6th May 2011

Thermal Coupling Of Cooling and Heating Systems

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Horizontal ventilation units

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Energy Efficiency HOSPITALITY.

RosevilleProject. LoE _ 2 Glass Products. You can reduce your cooling energy usage by 25% or more. Here is the proof.

High-efficient gas boiler CompactGas

Nirvana. Cycling Refrigerated Dryers

Combi Unit Genius. The energy efficient Building Service Centre

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Comfosystems Systems with heat recovery for a comfortable indoor climate

New Trends in the Field of Automobile Air Conditioning

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Comfort and superior energy efficiency through intelligent home automation

Ingersoll Rand. Heat-Of-Compression Air Dryers

We have been working in an ideal climate for thirty years.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

EXPERTS IN SWITCHGEAR CABINET EQUIPMENT

Heating and cooling with wastewater

RECALDO CLASSICO The reliable induction trolley for Cook & Chill, Cook & Serve and Cook & Freeze

Optimising Energy Use in Cities through Smart Decision Support Systems

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Scaleroline Quality demands perfection.

Energy Saving Fact Sheet Air Conditioning

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance

Executive Order amending the Executive Order on the Publication of the Danish Building Regulations 2010 (BR10) 1)

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

GREEN FACTS. Marina Bay Sands

Transcription:

Air-conditioning and climate-control technology We create a good indoor climate.

IS A GOOD CLIMATE A LUXURY? Most people spend a large part of their lives in closed rooms. Where this is the case, outside air is locked out together with the inclement weather. Air conditioning is therefore installed where many people share a limited volume of air. For good reasons, because good room climate conditions are not a luxury but an essential fact of life, indispensable for performance and well-being. What are the characteristics of a good room climate? First of all a pleasant temperature to avoid sweating or shivering, but that alone is not enough! Most people are not aware of how important the right humidity of the air is for people. Excessively dry air irritates the mucous membranes. High humidity gives an oppressive feeling, even if the temperature is right. Apart from the condition of the air, its quality also plays an important role. For example, unpleasant smells and noxious substances (such as smoke and CO 2 ) may be present in any building. The only solution is to supply an appropriate proportion of fresh air to the rooms in order to reduce the concentrations to an acceptable level. Numerous requirements one solution Naturally, demands on air conditioning are as individual as a person s other needs. The building surroundings also play an important role. Menerga provides air conditioning system solutions for nearly every sector, whether for swimming pool halls, comfort units for private houses or industrial and commercial premises. A typical feature of all Menerga systems is the synergetic combination of long-established, partly forgotten energy-saving technologies with innovative developments pointing the way to the future for this entire business sector. The very best energy recycling This method of regenerative heat recovery in air conditioning units yields considerable advantages. Above all, a high temperature efficiency of more than 90 %. Heat recovery from return air, for example in department stores, banks and other high traffic buildings with high internal heat loads, often makes reheating of outside air unnecessary. Furthermore, with Resolair comfort air conditioning units cooling recovery is possible and some of the indoor air humidity can also be recovered a further plus point for comfort. Menerga fields of application: Museums / galeries Low-energy buildings Theaters Historical buildings Sports grounds Public swimming pool halls Private swimming pool halls Hotels / restaurants Schools / universities Hospitals Shopping centers Offices / commercial buildings Banks Industry Data centers 2 Heat recovery Heating Cooling Moisture recovery Free cooling Control and adjustment

Comfort air conditioning for industrial and commercial buildings as well There are units in the Resolair family that have been developed especially for utilisation in industrial and commercial premises and so all the advantages of regenerative heat recovery are also available for this important sector of air conditioning. Further advantages: in most cases major reconstruction is not required even for refurbishment. Installation can be carried out while production is running. The units can even handle large air volumes and require minimal space for installation. For a good partnership Whether for planners, architects, plumbers, plant operators or owners our full expertise is available to all customers. Our experience of more than 30 years and several smart utilities from our own development, such as the h,x-diagram (psychrometric chart) software or our configuration design programs, help you manage your daily tasks. Our service team will continue to support you with advice and active solutions even after installation is complete. Quality provides the basis Quality is as important to us as to our customers. The supply of equipment that operates without fault and can be optimally adjusted is a matter of course for us. You may assure yourself of our quality even before delivery, being our guest during factory trial runs. BENEFITS Temperature efficiency of more than 90 % Based on its high degree of efficiency the Resolair can also be used in the summer as a cooling recovery system The entire cross-section of the unit is utilised, therefore low reciprocal loss of head and compact design of the unit High cost advantage in the operating costs Immediately operational installations, factory trial run La Suisse Assurances in Lausanne, Switzerland IT center Passau University, Germany 3

District hospital in Mainkofen, Germany Music school in Gruenwald, Germany Resolair Type 68 with regenerative energy transformer and compressor refrigeration system. Control unit Easy to use input and function buttons permit individual adjustments. Supplemented with a modem and the Menerga interface, the comfort air conditioning unit can be monitored almost anywhere. Thermal energy accumulators The readily accessible thermal energy accumulators contain high capacity heat storage mass and are easily cleaned. They take up thermal energy very quickly and release it just as quickly to cold air. The temperature efficiency achieved is greater than 90 %. 4

That s how it works: Resolair regenerative energy transformer The unit contains two heat packets with highly sensitive accumulator mass, through which the outside and exhaust air are transported alternately. The accumulator mass is able to capture heat from a warm air flow very rapidly and redeliver this just as rapidly to a cold air flow. Due to the constant exchange of outside air and exhaust air in the accumulators, there is a high recovery of humidity. Cycle 1 In cycle 1 the motor-driven flap system channels the return air via accumulator 1 and heats this up. At the same time cold outside air flows through accumulator 2, in which it is heated up together with the heat stored in the previous cycle. Cycle 2 In cycle 2 the outside air is heated up using the heat stored in accumulator 1. The return air then heats up the cooled accumulator 2 and prepares the next cycle. Cycle 1 Cycle 2 For the removal of higher internal heat loads at high outside air temperatures the integrated compression refrigerating machine is switched on for series 66 and 68. return air, outside air, supply air, exhaust air Resolair units from series 65 are specifically used in industrial and commercial buildings. For this type of unit the motor-driven flap system is located in the center of the unit. The air flow is channelled through the flap system in 2 cycles. As a result of the alternating admission of the heat packets, the heat of the return air is almost completely transferred to the cold outside air. 5

Details Which Are Right Every Time! AIRFLOW TES FROM THE SMALLEST! Nominal airflow rate m 3 / h 4,000 3,600 3,200 2,800 2,400 2,000 1,600 1,200 800 400 0 62 04 01 62 08 01 62 11 01 62 16 01 62 21 01 62 28 01 62 38 01 66 08 01 66 11 01 66 16 01 66 21 01 66 28 01 66 38 01 Unit types Everything tailored to fit! Type 62 Resolair With regenerative energy transformer Type 66 Resolair With regenerative energy transformer and compressor refrigeration system Length Width Height Weight Type 62 04 01 1,690 410 730 250 Type 62 08 01 1,850 570 730 300 Type 62 11 01 2,010 570 1,050 400 Type 62 16 01 2,260 730 1,050 500 Type 62 21 01 2,260 890 1,370 650 Type 62 28 01 2,580 1,050 1,370 750 Length Width Height Weight Type 66 08 01 2,490 570 730 390 Type 66 11 01 2,490 570 1,050 470 Type 66 16 01 2,740 730 1,050 570 Type 66 21 01 2,900 890 1,370 760 Type 66 28 01 2,900 1,050 1,370 850 Type 66 38 01 3,220 1,050 1,690 1,030 Type 62 38 01 2,740 1,050 1,690 890 All dimensions in mm and approx. weights in kg 6

Airflow rates CAN WE OFFER you more? Nominal airflow rate m 3 / h 40,000 36,000 32,000 28,000 24,000 20,000 16,000 12,000 8,000 4,000 0 64 05 01 64 07 01 64 10 01 64 12 01 64 15 01 64 17 01 64 21 01 64 26 01 64 32 01 65 07 91 65 17 91 65 26 91 Unit types EveryTHING tailored to Fit! 65 36 91 68 05 01 68 07 01 68 10 01 68 12 01 68 15 01 68 17 01 68 21 01 68 26 01 68 32 01 Type 64 Resolair With regenerative energy transformer L W H w Type 64 05 01 4,180 1,050 1,410 1,400 Type 64 07 01 4,660 1,050 2,050 1,800 Type 64 10 01 4,660 1,370 2,050 2,350 Type 64 12 01 4,820 1,690 2,050 2,820 Type 64 15 01 4,820 2,010 2,050 3,200 Type 64 17 01 5,620 1,690 2,780 4,000 Type 64 21 01 5,620 2,010 2,800 4,500 Type 64 26 01 6,100 2,010 3,440 5,550 Type 64 32 01 6,900 2,010 4,080 6,150 Type 65.. 91 Resolair With regenerative energy transformer, industrial and commercial air conditioning L W H w Type 65 07 91 4,110 3,700 1,170 2,570 Type 65 17 91 5,390 4,340 1,470 4,550 Type 65 26 91 6,030 4,660 1,810 6,040 Type 65 36 91 6,030 4,980 2,130 8,040 Type 68 Resolair With regenerative energy transformer and compressor refrigeration system L W H w Type 68 05 01 4,980 1,050 1,490 1,830 Type 68 07 01 5,300 1,050 2,130 2,340 Type 68 10 01 5,460 1,370 2,130 2,940 Type 68 12 01 5,620 1,690 2,130 3,550 Type 68 15 01 5,620 2,010 2,130 4,050 Type 68 17 01 6,580 1,690 2,860 4,560 Type 68 21 01 6,740 2,010 2,890 5,260 Type 68 26 01 7,220 2,010 3,530 5,970 Type 68 32 01 7,860 2,010 4,170 6,770 L = Length, W = Width, H = Height, w = weight All dimensions in mm and approx. weights in kg 7

Menerga GmbH Gutenbergstraße 51 45473 Muelheim an der Ruhr Germany Phone +49 208 9981-0 Fax +49 208 9981-110 E-mail info@menerga.com For web links to the distribution centers in your area please see www.menerga.com Menerga is represented throughout Europe WBD00026 Resolair Type 62, 64, 65, 66 & 68 Subject to technical modifications 12/2010 Cover photo: Shutterstock / Natthawat Wongrat