xlogic App from Easy Electronic-Overview



Similar documents
Siemens AG LOGO! App V1.0.0 LOGO! Edition 03/2013. Manual. Answers for industry.

Ethernet Module Manual

Application example and brief instruction 04/2015. LOGO! App V3.0. LOGO! 8 and LOGO! 7

Setting Up the ZigBee Ethernet Gateway

LOGO! LOGO! App V.10. LOGO! app 1. Making basic settings and establishing a connection to LOGO! Using the device overview 3. Creating controls 4

Android App for SAP Business One. Z3moB1le App Version 1.00 Pagina 1 di 12.

Quick Note 026. Using the firewall of a Digi TransPort to redirect HTTP Traffic to a proxy server. Digi International Technical Support December 2011

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

SPC Connect Configuration Manual V1.0

IDDERO TOUCH PANELS. Video door phone configuration

BECKHOFF. Application Notes. BC9000: Getting Started Guide. For additional documentation, please visit.

Quick Installation Guide

Sophos Mobile Control User guide for Apple ios. Product version: 2 Document date: December 2011

SBBWU PROXY SETTING IT CENTRE How to Set a Proxy Server in All Major Internet Browsers for Windows

Connecting to a Soundweb TM. London Network

FC5A Modbus Communication Training

Getting Started. Table of Contents. Quick User Guide - English

Table Of Contents. 2. Index iii

STEP 7 MICRO/WIN TUTORIAL. Step-1: How to open Step 7 Micro/WIN

ADTVision (ios) Mobile Client Software User Manual (V1.6)

Network Load Balancing

Flexi Soft Ethernet IP: Implicit Messaging with a Omron PLC

P-3202H-Bb. G-PON VoIP IAD DEFAULT LOGIN DETAILS. Firmware v1.0 Edition 1, 09/2009. IP Address: Password: 1234

Grandstream Networks, Inc.

Aeroqual Connect and Cloud

FAQ Communication over IE

SKP16C62P Tutorial 1 Software Development Process using HEW. Renesas Technology America Inc.

Offsite Control - Android Quick Start Guide

The service note describes the basic steps to install a ip camera for the DVR670

IDDERO TOUCH PANELS. Video door phone configuration

Remote Access. Table Of Contents. Rev: 3.30, 8/03

Description of service Mobile Dialer App

Grandstream Networks, Inc.

TOSR-04-5 TOSR-10B/C. LazyBone. Smartphone Controlled Switch. User Manual

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

Using the WAGO PROFINET Coupler as Remote I/O with a Siemens S7 PLC

TOSR0X-D. USB/Wireless Timer Relay Module. User Manual. Tinysine 2013 Version 1.0

HANTZ + PARTNER The Upgrade Company!

7. Mobile Phone Support

WAP3205 v2. User s Guide. Quick Start Guide. Wireless N300 Access Point. Default Login Details. Version 1.00 Edition 2, 10/2015

Setting up the Swann HD IP cameras

BlackVue Cloud App Overview...3. Getting Started...6. Basic Menu Screens BlackVue Cloud BlackVue Wi-Fi Internal Memory...

TECHNICAL BULLETIN. Configuring Wireless Settings in an i-stat 1 Wireless Analyzer

HRG App for Android Devices. User Guide

The goal is to program the PLC and HMI to count with the following behaviors:

Using KEPServerEX OPC Server (Kepware)with the iologik E2210

Application Note No. 12

Fibaro Intercom for ipad

MXview ToGo Quick Installation Guide

ViewCam Mobile Monitoring. User Manual

SUPPORT GUIDE FOR USING WLAN AND UPNP

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

HC900 Hybrid Controller When you need more than just discrete control

Clock Link Installation Guide. Detailed brief on installing Clock Link

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

1 How configure S7 PLC in the configuration tool

Student BYOD - Olathe Public Schools

and installation Enable Choose Enable, that s OK. Port Port for Mobile monitor, default at 34599,if you want to remote view the DVR by

Movie Cube. User s Guide to Wireless Function

WAVES. MultiRack SETUP GUIDE V9.80

Wireless VoIP Phone User s Manual

ScreenBeam Configuration Utility (Windows 8.1/10) User Manual. Solutions for the Digital Life. Ver 1.2

IMPORTANT PRODUCT INFORMATION

ZEN-SOFT01-V3. Cat.No.W386-E1-03

OCS Training Workshop LAB14. Setup

How to Program a Commander or Scout to Connect to Pilot Software

Phone: Fax: Web: info@ctiautomation.net

How to... Access your University Staff on your Android device

WNMS Mobile Application

How to connect? I can't connect to the Internet? Why are certain web pages blocked?

TRILOGI 5.3 PLC Ladder Diagram Programmer and Simulator. A tutorial prepared for IE 575 by Dr. T.C. Chang. Use On-Line Help

How To Use An Ip Phone With A Sim Sim Sims 2 (Iphone) Or Ip Phone (Ip Phone) With A Microsoft Ip Phone 2 (Ipphone) With An Ipro (Ipro) Or Sims 1 (Ip

SysAid MDM User Guide for Android

Quick Installation Guide

HTML Code Generator V 1.0 For Simatic IT Modules CP IT, IT, IT

Software User Guide UG-461

Phone Network Gateway Android Application. User Guide

NETGEAR genie Apps. User Manual. 350 East Plumeria Drive San Jose, CA USA. August v1.0

Contents. 1 VPN Remote Access Service

Contents. ST9612 Model WIC Printer. Get the original printer s information. Edited 11/04/15

Introduction. - Please be sure to read and understand Precautions and Introductions in CX-Simulator Operation Manual and

ivms-4500 (Android) Mobile Client Software User Manual (V3.1)

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Configuring Network Load Balancing with Cerberus FTP Server

Procedure for updating Firmware of EZ4 W or ICC50 W

SubCue Analyzer Software - Introduction

DVR-4TL/8TL/16TL Setup Guide

Ethernet Gateway for SIMATIC MPI/ PROFIBUS Driver

Installing LearningBay Enterprise Part 2

Quick Start. Nighthawk X8 AC5300 Tri-Band WiFi Router Model R8500. Package Contents. NETGEAR, Inc. 350 East Plumeria Drive San Jose, CA USA

PROFINET IO Diagnostics 1

Thank you for purchasing the Mobile WiFi. This Mobile WiFi brings you a high speed wireless network connection.

The irnetbox Manager User Guide

Rockets Smartphone Configuration. Spring 2012 Edition

Access to remote DVR from IE USER S MANUAL CONTENT

Guide VIGIL X-View (360 Dewarping Plugin) Guide

Connecting and Power-Up 3 rd -Party IP Camera through EverFocus IP Sidekick

Setting Up groov Mobile Apps. Introduction. Setting Up groov Mobile Apps. Using the ios Mobile App

Saville QUICK USER GUIDE. AV/IT Solutions & Services

Transcription:

xlogicapp Ver.1.0.0

xlogic App from Easy Electronic-Overview The free of charge xlogic App enables you to monitor actual process values of your xlogic & x-messenger application with a Android smart phone via WLAN or Internet. It allows to switch digital signal(digital flag, outputs) and adjust analogue values (analog outputs, analog flags, REGs). Supported will be the WLAN connection to a Ethernet module via IP address typically or Dyn DNS-names which are used in the Internet. xlogic App in android smart phone: With your xlogic App you can...... define customized names. For fixed connections and pre-configured values you can define customized names. This helps if you want to connect to several xlogic/x-messenger devices and monitor different values. Device list with names

... read and change date and time settings. Furthermore you can read, manually change or synchronous date and time settings with the actual date/time of your mobile device. Date and time settings... Monitoring IO status and kinds of register s value The status of IOs, kinds of registers such as digital flag, analog flag, REGs are

... Switch ON/OFF the Bit type status, and change the WORD type register values. Digital output, digital flag status can be switched ON/OFF by button, and some registers value also can be changed via smart phone.

xlogic App from Easy Electronic-Description Features Connection via IP-Address and DynDNS-name Supports connection via Internet without fixed IP-Address User specific names for devices Read and set date and time in xlogic/x-messenger and synchronization with date and time of the mobile device Get firmware version of xlogic/x-messenger Monitoring IO status, counter and analog values. Control the Bit status in program, and change the values of registers in program. Step by step to success 1 Download of the EASY xlogic App for Android operating system now 2 select the CPU model and configure the registers for monitoring and controlling 1.Select Model selection menu

2.There are for series CPU are available, because they are all having the Ethernet function. In fact the Ethernet CPU or (Ethernet expansion module) need work in the server mode, because the xlogicapp only can work under client mode. 3.Input the PLC address, the default is 1, and then click the Set.. button to select the registers. 3 Device configuration The xlogic App supports connection via IP-Address and via DynDNS-name. If you want to use Internet then you have to enable Port forwarding as the same as the one set in the xlogic App.

In addition to the physical address you can give a user specific name for the target device for simple recognition. A special configuration in the xlogic/x-messenger program is not necessary. Select kind of used connection 1. Select kind of used connection IP-Address or DynDNS-name. 2. Open the Device IP List. 3. Press button ADD to add a new 2 device.

4. Configure user specific name and address of the device. 5. Listed devices in the Device IP List. Select a Target device

1. Open the sub menu by a long click on the device in the Device IP List. 2. Select Select as Target in the sub menu. 3. Save button to save the changes. 4. Back to former menu.

Note: xlogic App is work as client, so the Ethernet CPU or Ethernet expansion module must work as server. Ethernet CPU configuration software print screen as below:

Ethernet expansion module configuration software print screen as below:

WIFI CPU configuration

5. Indicator of the selected target device. 3 Check the connection The simplest way to check the connection is to read the firmware version of the connected xlogic/x-messenger. A special configuration in the xlogic/x-messenger program is not necessary. Firmware version 1. Select Menu Show FW Version.

2. Firmware version of the connected xlogic/x-messenger 4 Read and Set date and time A special configuration in the xlogicapp program is not necessary. Read and Set date and time

1. Select the menu Set Clock in the main menu. 2. Select date or time for manual changes. 3. Button Read to read and show the actual date and time of the connected xlogic/x-m essenger. 4. Button Current to get the actual date and time information of your mobile device. 5. Depending on the selection the date or time information is shown and with the buttons + and you can change date or time manually. 6. Button Save to set date and time in xlogic/x-messenger to the selected values.

7. Note: Change RUN/STOP mode in xlogic /x-messenger (xlogic/x-messenger must be in STOP mode). 8. Note: Result of the transfer. And click OK to RUN the CPU.

5SetCPURUN/STOP 1. Select the menu Device Run Status Operate in the main menu.

2.Device status: it is the current status of the connected xlogic/x-messenger. 3. Click Stop and Run button to operate the CPU status. 6 Show status information of the connected xlogic A special configuration in the xlogic/x-messenger program is not necessary. 1. In the main menu select Set Monitor Option.. 2. Select which type register to monitor.

3. Click enter to show status information and the update time 4. Scroll to see information outside of the screen. 5. Selection of the update time.

6. Selection of the status information shown in the status table. 7. Button Save to confirm the modifications and show the status table. There are following items can be monitored Items Inputs Symbol in program Outputs Digital Flags Cursor Keys M

AM Analog Inputs Analog Outputs Analog Flags REG Sms message input Sms message output 7 Control register There are five kinds of registers can be controlled.

Bit type Output, Digital Flag can be switched ON/OFF

Note: 1.Only one item can be switched ON or OFF, you can select via clicking. 2. The input pin of output and the flag must be keep no connection in the program, otherwise it cannot be switched on/off via clicking the switch. For example, at below program, the F1,Q1,Q2 can be controlled, but the Q12 and the F2 cannot be switched ON/OFF directly in the xlogic App anymore, because they are separately controlled by the Q1, and B013 in the program.

Word type registers value can be changed by xlogic App. They are AF, AQ,REG You can select one AF from the table,and click Set button, after set successfully, xlogic App will read the value and display on the Current value Set AQ value

You can select one AQ from the table,and click Set button, after set successfully, xlogic App will read the value and display on the Current value Set REG value

You can select one REG from the table,and click Set button, after set successfully, xlogic App will read the value and display on the Current value Note: 1.Only one register value can be changed you can select via clicking. 3. The input pin of AQ and the AF must be keep no connection in the program, otherwise its value cannot be changed. For example, at below program, the AF1,AQ12,AQ1,AQ2 can be controlled, but the AF3,AF4,AQ11 and AF2 cannot be changed directly in the xlogic App anymore, because they are separately controlled by the AF1, AQ12,B014 and B015 in the program. 4.The REG value is the current value of blocks, for example If you change the REG0 value, the ON/OFF threshold of B001 cannot be changed; if you change the REG1 value, the ON/OFF threshold of B002 also cannot be

changed; But, because we have used the reference function for B003, The ON threshold is equal to B001 current value, and the OFF threshold is equal to B002 current value, so when you changed the REG0 and REG1 value, the ON and OFF threshold of B003 can be changed indirectly. So if you want to change the set point value of some blocks, you can try to reference the Up/Down counters in the dialog box of the relative function blocks.