SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

Similar documents
Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency

Microsoft Technology Center: Philadelphia

CUSTOMER EXPERIENCE CENTER

Liebert : The Right Cooling For IT Environments. Precision Cooling For Business-Critical Continuity

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Protecting Our Information, Protecting Our Resources

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

DCIM Readiness on the Rise as Significant Data Center Capacity Remains Unused. A Research Report from the Experts in Business-Critical Continuity TM

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Power Management Strategies for High-Density IT Facilities and Systems. A White Paper from the Experts in Business-Critical Continuity TM

DataCenter.BZ. Background. Case Summary. & dark fiber solutions

Ten Steps to Increasing Data Center Efficiency and Availability through Infrastructure Monitoring

Revolutionizing Data Center Infrastructure Management

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Applying Proper Cable Management In IT Racks A Guide For Planning, Deployment And Growth

How To Improve Energy Efficiency In Data Center Management

Applying Data Center Infrastructure Management in Collocation Data Centers

The Trellis Dynamic Infrastructure Optimization Platform for Data Center Infrastructure Management (DCIM)

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Unified Infrastructure Monitoring, Access and Control

Protecting The Critical IT Infrastructure of the United States

How To Make A Data Center More Efficient

The Trellis Dynamic Infrastructure Optimization Platform

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

The Trellis Dynamic Infrastructure Optimization Platform for Data Center Infrastructure Management (DCIM)

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Future-Proof the Banking and Finance Data Center

Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

How To Run A Data Center Efficiently

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

RagingWire Enterprise Solutions

The Four Trends Driving the Future of Data Center Infrastructure Design and Management

Liebert CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

IT White Paper IP TELEPHONY AND RELIABILITY: PROTECTING MISSION-CRITICAL PHONE SYSTEMS FROM POWER THREATS

Power Distribution Considerations for Data Center Racks

Scalable. Affordable. Flexible. Fast.

Virginia Tech. Background. Case Summary. Results

Energy Efficient Cooling Solutions for Data Centers

LIFECYCLE COSTING FOR DATA CENTERS: DETERMINING THE TRUE COSTS OF DATA CENTER COOLING

IT White Paper. N + 1 Become Too Many + 1?

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

Taking the Enterprise Data Center into the Cloud

Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

The Effect of Regular, Skilled Preventive Maintenance on Critical Power System Reliability

How To Run A Data Center Efficiently

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Zen Internet Case Study

Data Center Infrastructure Management: ERP for the Data Center Manager

Evaluating the Opportunity for DC Power in the Data Center

The Avocent Data Center Planner Real-World Insight for Smarter Data Center Management

Huawei Data Center Facility Integration Solution

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

Enabling an agile Data Centre in a (Fr)agile market

Seven Best Practices for Increasing Efficiency, Availability and Capacity: The Enterprise Data Center Design Guide

Technical Note: Comparing R407C and R410A as Alternatives for R22. A Technical Note from the Experts in Business-Critical Continuity

Energy Efficiency and Availability Management in Consolidated Data Centers

High-density modular data center making cloud easier. Frank Zheng Huawei

Precision Cooling for Business-Critical Continuity. Liebert PCW. Cool the Cloud

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

Enterprise Remote Monitoring

Effects of AC Ripple Current on VRLA Battery Life. A Technical Note from the Experts in Business-Critical Continuity

Liebert NXC from 10 to 200 kva

Secure, Remote Access for IT Infrastructure Management

What to Consider When Designing Next-Generation Data Centers

How To Save Energy On A Power Supply

Move beyond the expected.

Understanding the Promise of (DCIM)

Common mistakes in datacentre planning

Data Centre Outsourcing a Buyer s Guide

Data Center Trend: Distributed Power in the White Space

Common Access Card Application

Achieving a New Level of Data Center Performance

Data Center Infrastructure Management

The Pros and Cons of Modular Systems

Advantages and Efficient Use of Programmable Sockets. By Miguel Rascon AC Power Senior Product Manager

Reducing Data Center Energy Consumption

Smart Data Center Solutions

Power and Cooling Best Practices for IP Communications. A White Paper from the Experts in Business-Critical Continuity

Transcription:

SmartDesign Intelligent, Integrated Infrastructure For The Data Center Solutions For Business-Critical Continuity

Prepare Your Data Center For What s Next Efficiency. Availability. Capacity. Control. One Approach Studies from the Data Center Users Group reveal that efficiency, availability, capacity and control continue to be leading concerns within data centers. As a result, it is more important than ever for economic and business considerations to drive data center decision-making. Efficiency Saves The proper data center design can provide an organization with significant operating savings. Data center professionals are routinely reducing their energy costs by 30-50% or more, while simplifying the process of deploying and operating a facility. Availability Matters The 2011 National Study on Data Center Downtime reveals: The mean costs for any type of data center outage is $505,502 The average cost of a partial data center shutdown was $258,149 A full shutdown costs more than $680,000 Employing a data center design approach that delivers availability and capacity is one of the most effective ways of preventing outages and disruption, saving a company from a loss of goodwill, revenue and productivity. Pulling It All Together The combination of expertise, technologies and systems need to come together to achieve your goals. Ensuring availability and capacity does not mean sacrificing efficiency or control. Data center designers are discovering and applying proven models to cutting energy costs. The SmartDesign approach from Emerson Network Power helps you deploy and utilize effective configurations that eliminate these challenges, while saving money and maintaining performance. With the SmartDesign approach, you can be prepared for what s next: Deploy innovative systems that utilize highly efficient cooling, UPS, power distribution, rack/enclosures and infrastructure management Leverage industry best practices to ensure that your data center is operating optimally and cost effectively Take advantage of Emerson Network Power local data center design expertise, service and support to help plan, deploy, maintain and expand your data center Reduce energy costs by up to 50% with a SmartDesign approach. 2

Leverage the advantages of an integrated infrastructure Economical Ensures availability and reduces downtime costs through effective designs and configurations Extends data center life Saves CAPEX by applying innovative technologies Efficient Improves efficiency more than 50% using innovative cooling systems Provides reliable, scalable power using advanced energy optimization features Improves availability using designs and configurations matched to needs Design Simplified Provides integration for critical systems Reduces expensive renovation and construction costs Incorporates local service and support experts to improve configuration, installation, preventive maintenance and repair Controllable Directs cooling units to work together, eliminates conflicts to save energy Streamlines IT planning to optimize space/capacity utilization Identifies concerns; addresses problems before they create issues Monitors power, temperature, humidity, and air flow while ensuring efficient operating levels improving efficiency and availability Intelligent, integrated infrastructure for the data center Smart Solutions help you cost-effectively achieve and manage levels of density, availability and efficiency. Design 3

Industry-Best Practices Put into Action Emerson Network Power and the SmartDesign approach simplify the complex environment of data centers by bringing together the most comprehensive power, precision cooling, monitoring and management technologies, as well as providing industry-best practices to deliver infrastructures that overcome challenges in efficiency, availability and capacity. The seven best practices to improved optimization include: Technology Solutions A High availability, high efficiency UPS Systems B Flexible and scalable power distribution and switching C Room and row-based precision cooling D Aisle Containment for higher efficiency A 1 2 3 4 Maximize the return temperature at the cooling units to improve capacity and efficiency Match cooling capacity with IT loads Utilize cooling designs that reduce energy consumption Select the power system that optimizes your availability and efficiency E Innovative DCIM technologies 5 Design for flexibility using scalable architectures that minimize footprint 6 Enable performance-enhancing data center infrastructure management, monitoring and control 7 Leverage local data center design expertise and technical assistance Read more about these best practices in our white paper, Seven Best Practices for Increasing Efficiency, Availability and Capacity: The Data Center Design Guide 4

C E B E B D E C E C 5

SmartDesign Approach Ensures A Better Infrastructure Support and Design Expertise from Emerson Network Power SmartDesign configurations start by leveraging our four decades of data center expertise. Local data center infrastructure specialists, supported by the industry s largest service organization, work in tandem with industry planners, engineers and contractors to meet customer requirements. These experts collaboratively assess each situation, recommend the best option and deliver it effectively and efficiently. Innovative Technologies and Systems from Emerson Network Power The SmartDesign approach uses the industry s most reliable and comprehensive product offering to deliver critical availability, scalability, intelligence and capacity, while ensuring the highest efficiency. Cooling Energy-efficient, scalable precision cooling and control systems Widest array of high-density cooling systems enable energy efficient operation, improved capacity and reduced footprint Intelligent cold aisle containment systems improve energy efficiency and capacity Fluid, air and refrigerant economizers maximize free cooling Power Wide range of large power UPS systems offer scalability, efficiency and reliability Power configurations which can be designed for every availability and redundancy situation Robust power distribution systems provide flexible, intelligent and reliable power from the utility to inside the rack DCIM and Support Comprehensive line of infrastructure management solutions provide visibility and control, to improve uptime and efficiency Largest and most highly trained local service and support team ensures systems uptime and improved performance A local data center infrastructure specialist will assist you in the proper selection and configuration of these innovative technologies, to ensure you obtain the optimum design for your needs. SmartDesign approach is ideal for any room-based data center project. 6

Demonstrated Success The SmartDesign Approach Ensures Optimal Performance DataCenter.BZ Critical need: Support DataCenter.BZ s data center expansion with an ultra-high-density power and cooling infrastructure optimized for efficiency and flexibility without compromising its 2(N+1) high-availability operational commitment. Results: Substantial gains in power and cooling capacity enabled DataCenter.BZ to continue providing data center customers with 500 watts per square foot of power across a 32,000-square-foot raised floor along with ultra-highdensity cabinet power deployments some up to 90 kw (50 kw in standard racks) Cooling infrastructure achieved a facility-wide PUE of 1.25 or less Projected to achieve LEED Certification from the United States Green Building Counsel (USGBC) 100 percent site availability since completion of initial carrier-neutral data center provisioning in 2007 2(N+1) redundancy maintained on all critical power and cooling infrastructure Cyber Development Critical need: Support Cyber Development Group International s data center expansion efforts with an enterprise infrastructure optimized for efficiency and flexibility, while ensuring availability demands dictated by cash-backed, zero-downtime SLAs. Results: Increased efficiency by 12 and 30%, respectively, through enhanced perimeter and row-based cooling technologies Achieved availability levels in excess of six-nines (99.9999 % uptime), resulting in zero unplanned downtime over a 12-month period Reduced total energy bill by an average of 14% by implementing a new design using supplemental cooling, cold aisle containment and innovative cooling strategies (on the perimeter and in the row) Achieved on-target PUE, earning the facility the title of Most Energy Efficient Data Center in the Chicago Metropolitan Area Sarasota County Critical need: A data center design that would effectively and efficiently use the technologies and best practices available today to provide high availability, scalable capacity and an efficient operation. Results: Reduced data center equipment needs by 20% through an intelligent, integrated design approach. Minimized IT footprint by incorporating server virtualization along with innovative power and cooling technologies. Eliminated additional single points of failure using a comprehensive N+1 power design Reduced cooling costs and improved reliability with management and control systems that direct units to work together, eliminating conflicts I don t see this data center working without our SmartDesign infrastructure. Rene LeBlanc, Manager, Data Center Operations, Go Daddy 7

SmartDesign Reference Scenarios: Applied to Meet Your Goals Our Reference Scenario Guides are designed to give you a glimpse of the virtually limitless possibilities of the SmartDesign Approach. 1100kW Tier 2 With Air Economization In this scenario, cooling is configured around four large capacity 400kW Liebert CW units with air economization, partial cold aisle containment and Liebert icom controls. Electrical design is a Tier 2 using the 500kVA Liebert NXL UPS in 3+1 redundant plan; with six Liebert PPC PDUs, Liebert MB modular busway and Liebert MPX rack PDUs. Benefits: Reduces floor space usage 34% Saves $5 MM in CapEx Lowers energy bill by $60,000 per year Ensures maximum uptime for Tier 2 UPS operates at 97% efficiency, 80% of the time, generating energy savings of over $37k per year Lowers installation and maintenance costs, while providing for fast and easy reconfigurations Design Capacity: 1100kW Tier: 2 Mechanical, 2 Electrical single bus Facility Size (s/f): 4,307 RF / 3,223 DC / 1,752 ER Number of Racks: 90 Containment: Partial, doors only Average Rack Density: 12kW/rack Economization: Air-side Raised Floor: 36 PUE (total / cooling): 1.28 / 1.18 UPS Efficiency: 97.4% via efficiency mode Redundancy: N+1 Emerson Network Power Equipment: (4) Liebert CW 400kW (4) Liebert NXL 500kVA UPS (6) Liebert PPC PDU Liebert MB Busway (90) DCF Optimized Racks (90) Liebert MPX rack PDU ASCO ATS Liebert Nform Albér Battery Monitoring Avocent Data Center Planner tt Premium Base Mechanical Tier 2, Electrical Tier 4 This SmartDesign Cost Savings (vs. Base) Cost Advantage Total Annual Energy Cost $377,676 $317,564 $60,112 16% 5 Year OpEx $1,888,380 $1,587,820 $300,560 16% 5 Year TCO $20,770,517 $15,445,480 $5,325,037 26% 8 * TCO is fully burdened with building and related costs

1100kW Tier 3 With High Density In this scenario, the innovative, high efficiency Liebert XDR rear door heat exchangers are partnered with base-cooling using Liebert CW units to save both operating expenses and space. We pair this with an equally efficient power design using Liebert NXL 1100kVA UPS in a Tier 3, 2N configuration. Benefits: Reduces raised floor space by 60% Lowers racks needed by 62% Reduces energy costs 44% with heat neutralizing rack coolers Provides highly-scalable cooling options Utilizes efficient double conversion UPS with near unity PF The tier 3 design protects against most all downtime while being concurrently maintainable Design Capacity: 1100kW Tier: 2 Mechanical, 4 Electrical Dual bus Facility Size (s/f): 2,609 RF / 1,701 DC / (2) 1,446 ER Number of Racks: 56 Average Rack Density: 20kW/rack Raised Floor: 36 Economization: Fluid-side PUE (energy / cooling): 1.26 / 1.16 UPS Efficiency: 97.4% via efficiency mode Redundancy: 2N Emerson Network Power Equipment: (2) Liebert CW 114kW (56) Liebert XDR (8) Liebert XDP (12) Liebert PPC PDU (12) Liebert FDC PDU (2) Liebert NXL 1100kW UPS (112) Liebert MPX Rack PDU (56) DCF Optimized Racks ASCO ATS Liebert Nform Albér Battery Monitoring Avocent Data Center Planner tt Premium Base Mechanical Tier 2, Electrical Tier 4 This SmartDesign Cost Savings (vs. Base) Cost Advantage Total Annual Energy Cost $377,676 $232,681 $144,995 38% 5 Year OpEx $1,888,380 $1,163,405 $724,975 38% 5 Year TCO $20,770,517 $16,408,453 $4,362,064 21% * TCO is fully burdened with building and related costs 9

SmartDesign Approach: For Medium or Large Data Centers A SmartDesign approach is available to fit the needs of your data center. Look for a reference design that fits your IT load, availability requirements and efficiency target. Visit www.smartsolutionsdesigns.com and view more examples. 180kW Tier 2 With Row-Based Cooling, Room-Based Power IT Load: 180kW Tier 2 Opex Savings: $67,000/yr TCO Savings: $196,000 over 5 years PUE: 1.27 500kW Tier 2 With High Efficiency Refrigerant Economization IT Load: 500kW Tier 2/ 4 power Opex Savings: $170,000/yr TCO Savings: $379,000 over 5 years PUE: 1.29 1300kW Tier 4 With High Efficiency Refrigerant Economization IT Load: 1300kW Tier 4 Opex Savings: $420,000/yr TCO Savings: $953,000 over 5 years PUE: 1.28 * TCO based on infrastructure technologies CAPex and Opex 10

Text Get Started with the SmartDesign Approach Today Efficiency Throughout the Planning and Operation Phases With the SmartDesign approach, you ensure efficiency across the lifecycle of the data center. As your infrastructure partner, we provide the on-going support that keeps your data center operating at peak levels of performance. Field engineering is available 24x7. Professional assessment services are offered to ensure continual performance adjustments and improvements. Management and Planning Streamline operations with comprehensive management controls Lower long-term operational costs with proactive maintenance programs Design & Deployment Simplify configuration and implementation Reduce the time required for system design and deployment Reduce space and capital requirements Operation Reduce energy costs with efficient technologies Decrease downtime costs through high availability configurations Increase productivity through greater efficiencies Visit www.liebert.com, under Smart Solutions, to explore new scenario references that depict additional ways to apply SmartDesign configurations. Contact Your Local Data Center Infrastructure Specialist to Get Started Today Whether you are building a new data center, expanding your current environment or renovating an older installation, we can help you create, implement and operate an infrastructure solution that meets your needs. Schedule a discussion with your Emerson Network Power representative to begin developing a SmartDesign infrastructure for you. To find out more about the SmartDesign approach and view more Reference Scenarios, visit www.liebert.com 11

Emerson Network Power, a business of Emerson (NYSE:EMR), delivers software, hardware and services that maximize availability, capacity and efficiency for data centers, healthcare and industrial facilities. A trusted industry leader in smart infrastructure technologies, Emerson Network Power provides innovative data center infrastructure management solutions that bridge the gap between IT and facility management and deliver efficiency and uncompromised availability regardless of capacity demands. Our solutions are supported globally by local Emerson Network Power service technicians. Learn more about Emerson Network Power products and services at www.emersonnetworkpower.com Emerson Network Power Liebert Corporation World Headquarters 1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio 43229 United States Of America 800 877 9222 Phone (U.S. & Canada Only) 614 888 0246 Phone (Outside U.S.) 614 841 6022 FAX Contact@EmersonNetworkPower.com Emerson Network Power Caribbean and Latin America Office United States of America +1-954-984-3452 Phone Ask.Cala@Emerson.com Emerson Network Power European Headquarters Office Italy +39 049 9719 111 Phone +39 049 5841 257 FAX Marketing.EMEA@EmersonNetworkPower.com Emerson Network Power Asia Pacific Office Phillipines +63 2 687 6615 +63 2 730 9572 FAX Marketing.AP@Emerson.com liebert.com 24 x 7 Tech Support 800 222 5877 Phone 614 841 6755 (outside U.S.) While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 2012 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. Emerson Network Power. The global leader in enabling Business-Critical Continuity. All names referred to are trademarks or registered trademarks of their respective owners. Liebert is a registered trademark of the Liebert Corporation. SL-11500 (R02/12) Printed in USA EmersonNetworkPower.com AC Power Embedded Computing Outside Plant Outside Plant Connectivity Embedded Power Power Switching & Controls Power Switching & Controls DC Power Infrastructure Management & Monitoring Precision Cooling Precision Cooling Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 2012 Emerson Electric Co.