LIGHTNING DETECTION IMPROVEMENT FALLS BROUGHT TO ESKOM S TRANSMISSION LINE DESIGN AND FAULT ANALYSIS



Similar documents
ANN Based Fault Classifier and Fault Locator for Double Circuit Transmission Line

Ultrasound Condition Monitoring

Power products and systems. Intelligent solutions for power distribution Zone concept

SES Training & Certification Programs Welcome to the SES Grounding, EMI and Lightning Academy

Telecommunication Line Protectors

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

J W Spencer School of Electrical Engineering, Electronics and Computer Science

Management Systems 10 Electrical Safety Audit 14 PPE 20 Arc Mitigation 22 Hazard Assessment 26

POSITIVE POLARITY: MISCLASSIFICATION BETWEEN INTRACLOUD AND CLOUD-TO- GROUND DISCHARGES IN THE SOUTHERN AFRICAN LIGHTNING DETECTION NETWORK

EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID

Engineering innovation

REDUCING UNCERTAINTY IN SOLAR ENERGY ESTIMATES

Bourns Resistive Products

Overhead lines in Ireland

Solar Input Data for PV Energy Modeling

Eldorado-Ivanpah Transmission Project WELCOME To Southern California Edison Company s Eldorado-Ivanpah Transmission Project OPEN HOUSE

Substation Grounding Study Specification

Reduction of Lightning Caused Interruptions on Electric Power Systems Reduction Des Compures Dues a la Faudre Dans Les Reseaux

SAFETY LIFE-CYCLE HOW TO IMPLEMENT A

Study of Lightning Damage Risk Assessment Method for Power Grid

Sensitivity Analysis of Safety Measures for Railway Tunnel Fire Accident

Power System review W I L L I A M V. T O R R E A P R I L 1 0,

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

Study to Determine the Limit of Integrating Intermittent Renewable (wind and solar) Resources onto Pakistan's National Grid

Alberta Reliability Standard Cyber Security Configuration Change Management and Vulnerability Assessments CIP-010-AB-1

NETWORK OUTPUT MEASURES METHODOLOGY Authors: National Grid, SP Transmission Limited, Scottish Hydro Electric Transmission Limited

ESCOM BY G.KALINDE SUBSTATIONS ENGINEER

Overhead lines Asset Management in the Belgian network. S. GERMAIN K. VAN DAM B. RISSE JF. GOFFINET Elia Belgium

EVALUATION OF ON-SITE DIELECTRIC RESPONSE METHODS FOR NON- DESTRUCTIVE TESTING OF WATER TREED MV XLPE CABLES

Comparison between Gas- and Air Insulated Network Concepts with the Life Cycle Cost Method

2012 San Francisco Colloquium

Transient and Lightning Protection for the Water Industries

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

INTEGRATED EVENT MANAGEMENT

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

Assessment of the Technical Issues relating to Significant Amounts of EHV Underground Cable in the All-island Electricity Transmission System

Reducing human error in revenue management decision-making

Accident Bulletin 2/2012 (An update to Accident Bulletin 3/2011) Aerospatiale SA 315B LAMA helicopter

Title: IEC WT 01 vs. IEC Development of a new standard and innovations in certification of Wind Turbines. mike.woebbeking@gl-group.

How To Monitor Water Penetration In A Cable Screen

Generation Interconnection Feasibility Study Report-Web Version. PJM Generation Interconnection Request Queue Position Z1-055

Operational perspective on the Electricity Distribution Industry (EDI) turnaround

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012

Strength and Durability for Life CORROSION CONTROL. The Effect of Overhead AC Power Lines Paralleling Ductile Iron Pipelines

Respecting the environment

Climate Change Long Term Trends and their Implications for Emergency Management August 2011

High Voltage Electrical Equipment Failure Diagnosis. Presented by: Spencer Tang & Terence Ng T&T Inspection & Engineering Sdn Bhd

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

Web application security: automated scanning versus manual penetration testing.

Brochure Introducing HVDC

Control Development and Modeling for Flexible DC Grids in Modelica

OHMIC MEASUREMENTS: THE HISTORY AND THE FACTS

(2) Words and expressions used and not defined in these regulations but defined in the Act shall have the meaning assigned to them in the Act.

Testing Low Power Designs with Power-Aware Test Manage Manufacturing Test Power Issues with DFTMAX and TetraMAX

Sandia National Laboratories New Mexico Wind Resource Assessment Lee Ranch

The Canadian Lightning Detection Network Novel Approaches for Performance Measurement and Network Management

Kresimir Bakic, CIGRE & ELES, Slovenia

EUROPASS DIPLOMA SUPPLEMENT

IRP 2010 Energy Forecast Revision 2 Report

A. 5MWp SPV Plant at Khimsar, Rajasthan. B. 5MWp SPV Plant Installed Technologies. D. 5MWp SPV Plant Challenges. E. 5MWp SPV Plant - Performance

Cathodic Protection. Remote Monitoring of Cathodic Protection on a Gas Distribution Network

Estimating AC Mitigation Requirements for Pipelines Installed in High Voltage AC Corridors: Fault Conditions

South African Distribution Code

Wildfires pose an on-going. Integrating LiDAR with Wildfire Risk Analysis for Electric Utilities. By Jason Amadori & David Buckley

Simulation électromagnétique 3D et câblage, exemples dans l'automobile et aéronautique :

Technology Solutions for NERC CIP Compliance June 25, 2015

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters

ENGINEERING REPORT. XYZ Corporation 100 Anyplace Drive Chicago, Illinois 60613

Technical Guidance Note 287. Third-party guidance for working near National Grid Electricity Transmission equipment

Integrating Renewable Electricity on the Grid. A Report by the APS Panel on Public Affairs

The Bulk Way UHV DC the new dimension of efficiency in HVDC transmission Answers for energy.

Electricity Price Comparison. Namibia Manufacturers Association (NMA)

Electrical Resistance Resistance (R)

Monitoring, diagnostics, and cable services

The Status of the Wind Power Market in Egypt. Dr. Walid El-Khattam Ain Shams University (Cairo, Egypt) The Egyptian Electricity Regulator (EgyptERA)

City Of Ottawa High Voltage Substation Inspection, Maintenance Rev July 17 and Testing, ROPEC Page 1

System Protection Schemes in Eastern Denmark

Test & Data Management Software

Experimental Verification of Advanced Voltage Control for Penetration of PV in Distribution System with IT Sectionalizing Switches

SAMPLE OF THE STUDY MATERIAL PART OF CHAPTER 3. Symmetrical Components & Faults Calculations

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Nuclear Power Plant Electrical Power Supply System Requirements

Value of storage in providing balancing services for electricity generation systems with high wind penetration

FERC Order 1000 Transmission Planning and Cost Allocation. FRCC Board Briefing June 28, 2012

Intelligent power superhighways

City of Vernon Request for Expressions of Interest and Information (RFI)

Design and testing of polymer-housed surge arresters with special emphasize on seismic stresses and selection of specific creepage in costal areas.

Towards an Enhanced Telluric Compensation Methodology

THE LIGHTNING PROTECTION INTERNATIONAL STANDARD

Outline Intrusion Detection CS 239 Security for Networks and System Software June 3, 2002

Studienkomitee C4 System Technical Performance

SANS : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation

EA Technology (UK) EA Technology (UK) NEDL (UK)

INTERNATIONAL STANDARD

DS 600. A contact free flux gate based current measurement sensor 600A rms

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Weather-readiness assessment model for Utilities. Shy Muralidharan Global Product Manager Energy Solutions Schneider Electric

Grid connection of near shore wind farms

Estimation of electrical losses in Network Rail Electrification Systems

Transcription:

LIGHTNING DETECTION IMPROVEMENT FALLS BROUGHT TO ESKOM S TRANSMISSION LINE DESIGN AND FAULT ANALYSIS Luthando Peter Faith Mokhonoana Eskom Trans Africa Projects, Midrand Johannesburg South Africa 1 INTRODUCTION Lightning contributes around 24% to Eskom Transmission s total transmission line faults. Measures have been taken over the past decades to combat this effect of lightning on the performance of high voltage transmission lines and these measures are usually taken after the lines have been constructed and operational for a certain period. From a design perspective, accurate prediction of lightning faults expected for new lines is ideal as this will enable designers to design accordingly. 2 Lightning Activity in South Africa The figure below highlights lightning activity patterns in the recent years. (SALDN lightning statistics since Nov 2005) Total 65 million strokes Average per annum = 24,7 million strokes Summer season 06/07 (Oct to Apr) 21,5 million strokes Eskom s previous lightning detection system was LPATS (Lightning Position and Tracking System) and was decommissioned a couple of years ago to give way to a new lightning detection system, FALLS (Fault Analysis and Lightning Location System)[1]. This paper shares how FALLS has been used in specific investigations to improve fault diagnostics and informing the utility about whether certain faults were due to lightning or not. Looking into the future, perhaps the possibility of being able to download the actual lightning waveform from FALLS for specific strokes of interest which could help with investigations and simulations further. Figure 1: Annual lightning stroke count SA [2] The ground flash density map shown below shows the various areas and their ground flash densities. This map is being used in the overhead line design process to perform lightning performance analysis.

zone around it, so that efforts may be concentrated in the study area, LPATS could not perform this task. It also could not assist much at the design stages, where a more accurate ground flash density of the area being traversed by the overhead line was needed. Issues around ability to execute detailed statistical analyses with regards to the stroke magnitudes and frequency in certain areas also were becoming a major challenge. 3.2 FALLS Figure 2: Ground Flash Density map 3 Lightning Detection Networks used by Eskom - History and Current 3.1 LPATS Eskom was using LPATS and it had served the utility well over the years. Investigations relating to lightning incidents on overhead transmission lines could be done and concluded with the assistance of LPATS, in terms of verifying whether there was a storm in a particular area and what the magnitude of the lightning incident was. LPATS assisted in developing a flash density map to a certain degree. With advances in technology, questions got asked about its location accuracy and detection efficiency. When applied to lightning incident investigations, there were concerns also about its efficiency relating to successful investigation and diagnosis of lightning incidents on the transmission network. There were times where LPATS would not pickup lightning activity in certain areas where there was lightning activity that was witnessed. This was more pronounced when a specific area needed to be analyzed, with a buffer The most recent acquisition by Eskom with regards to Lightning Location Systems is FALLS and it has already brought about noticeable advantages. Such advantages are its ability to perform regional, small area exposure, gridded exposure and reliability analyses, where through the use of buffer zones, areas of concern can be studied further. Statistical data for the lightning strokes is also made available for further analysis. The ability to create assets with FALLS has allowed not only investigation of possible lightning impact on existing assets, but as part of new transmission line design, designers are able to investigate various routes and the lightning activity in those routes. 4 Application of FALLS in Overhead Line (OHL) Design 4.1 Route Selection Prior to the design of an OHL, decisions have to be taken about the route that the OHL will traverse. There are a number of factors that are considered in the process. When a corridor is finally decided on following the environmental impact assessments outcome, 2 or 3 specific routes within that corridor (which can be 2-5 km

wide) will be chosen. This is where line designers also have a significant input with regards to a better route for the line. A number of issues are looked at, ranging from bend points (which increase the cost of a line if too many), Industrial activities (pollution levels) as well as lightning activity in the area. Since FALLS was introduced, it is used to zoom into the various routes that are tabled as possible choices and from the various analyses (Regional, Small Area Exposure and Reliabity analyses) lightning activity of each of the routes can be thoroughly studied. By so doing, designers will be able to predict lightning activity in the various routes and select the one that will have fewer problems (or require less intervention as far as mitigatory measures against lightning are concerned). This consequently has a huge impact on ensuring that minimization of lightning related faults on the transmission line gets done upfront, instead of during the operating life of the plant, which could be very costly, not only to Eskom but to its clients also. 4.2 Lightning Performance analysis during design Prior to the use of FALLS, information regarding lightning activity at an area was based on the ground flash density map and the utility s fault records. Use of FALLS allows designers to look into various areas of the line route and using the strokes density, areas with high lightning activity can be studied better and predict what the expected performance of lines will be with the use of Tools such as T-Flash. This ensures that traverse very high lightning prone areas with high ground flash densities can be designed incorporating solutions to mitigate against lightning faults. This practice is better than only identifying problem areas during the operational phase of the line as mitigatory measures may be more costly. 4.3 Asset Management Existing Lines The aim of asset management is to ensure that plant performs its task as per its design specifications. Part of asset management is performance management, which looks at the above and addresses any deviations from the set performance targets by the asset. Utilities spend millions of rands on performance management programs for their assets. 4.3.1. Fault Correlation When a fault has occurred on a line, it must be classified, either as a Bird, Fire, Lightning or design related fault, amongst other categories. Faults that are suspected to have been caused by lightning were usually difficult to prove and if there were storms or lightning seen in that area before the fault, it was automatically assumed that lightning was the cause. The concern with misdiagnosis is that the utility winds up spending its resources on causes that may not necessarily improve the performance of the asset. The use of FALLS is also to confirm lightning activity at a specific area, at a specific time, known as fault correlation. The example below illustrates a case where FALLS was used for fault correlation. A specific 275kV Eskom line was identified as having continuous lightning related faults and towards the end of 2005 a study was commissioned to look at possible use of TLSA s to improve this line s performance [3]. The TLSA were installed end of 2005 and a review of the line s performance was done in 2009 to check the effectiveness of the solutions.

Eskom s newly acquired FALLS was used as means of correlating first and foremost the faults experienced during the period after the TLSA installation and also, as an estimate of possibly how many more faults could have occurred should the TLSA not been installed. Figure 3 below shows the lightning performance of the line in question until the end of 2005. General Performance Review as part of asset management The performance review was carried out in 2 parts; one part looked at general overall lightning performance of the line and compared the current overall performance of the line with what was predicted i.e. 1.212 faults/100km/annum [4]. The second part looked at fault correlation with the use of FALLS in investigating these faults and checked whether they occurred within the area where the TLSA were installed and whether the TLSA were effective or not. Figure 4 below shows one of the FALLS correlation analysis that was done. Figure 3: Annual line lightning faults per 100km Figure 4 below shows the general performance of the line since the installation of the TLSA. It should be noted that these faults are generally reported faults without the use of a lightning location system to verify their authenticity. Figure 5: April 2006 lightning Activity Looking at the line s lightning performance prior and after the installation of the TLSA i.e. from 2006 until 2008, their average showed an improvement of 61%. This value is without verification with the use of the lightning location system. Figure 4: General performance of the line before and after TLSA installation (per 100km/annum) This improvement shows the effectiveness of the installation already by

the virtue of this drop in lightning related faults on this line. Performance Improvement review with the use of FALLS as part of Asset management The incidents that were categorized as lightning related by the grid are referred to as cases below. The 2006 FALLS correlation shows for case 1 that there was no correlation and this would imply that according to FALLS this fault didn t take place. While the correlation for case 2 correlated a -31 ka nearby stroke close to tower 200. Whether it was high enough to cause an induced flashover on a 275kV line was questionable. The 2007 FALLS correlation for case 1 is a -13kA close to tower 240 and its magnitude was too low to cause an induced flashover on a 275kV line as this tower s measured tower footing resistance was 12 ohms which is low to have made the tower to have an induced flashover from a stroke of such a magnitude. Case 2 was correlated with a nearby stroke of -19kA stroke in the region of tower 243 which also had a very low tower footing resistance of close to 5 Ohms and could not have caused an induced flashover on this tower. 2008 FALLS Correlated case 1 to a -52kA nearby stroke which was assumed could have caused an induced flashover. Case 2 was correlated to a -71kA nearby stroke close to tower 140 which also could have caused an induced flashover as this region also doesn t have TLSA. Case 3 was also correlated to a -13kA nearby stroke which would have been too low to cause an induced flashover to any of the structures in its vicinity. According to FALLS correlation, the line s performance improvement is 83% instead of the reported 61%. 4.3.2 Lightning Performance Improvement Mitigation as part of Asset management Lightning performance improvement, as already discussed above, could also be done through the use of Transmission Line Surge Arresters, as done on the line studied above. The use of FALLS on this line s performance review has allowed the designers to be able to review whether the selection of the ratings of the TLSA installed on this line was correct or not. FALLS could avail all the various current magnitudes that the line s buffer zone was subjected to in order to be able to check the energy capabilities of the TLSA and hence being able to review whether the design assumptions during the development of the mitigation strategy were realistic or not. 4 CONCLUDING REMARKS AND RECOMMENDATIONS FALLS has, within a very short time period of application in Eskom shown positive benefits as the paper has shown above. Its use in the route selection process, design stages of transmission lines and the investigations of performance of already existing lines is becoming more effective. As users of the tool, there are opportunities that have been identified for improvement of the tool in areas such as following: A more automated means of generating Stroke Density Maps for ease of exporting to T-Flash for area analysis

Ability for the sensors to capture the actual lightning waveforms, so as to be able to do detailed incident investigations with representative waveforms, not generic ones. REFERENCES [1] FALLS Client User Guide version 3.2 August 2004 [2] R. Evert, Lightning Information Application in Eskom Distribution, March 2008, SALDN User Group, Eskom, South Africa [3] F. Mokhonoana, L Peter Review of Lightning Performance Improvement Project Results: A Case Study from South Africa CIGRE 2009, [4] L. Peter, Use of Line Surge Arresters to improve Lightning performance of a 275kV line: A South African Pre-Engineering Case Study, ICLP 2006, Kanazawa