Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate



Similar documents
Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

ANALYTICAL METHODS INTERNATIONAL QUALITY SYSTEMS

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Development of validated RP- HPLC method for estimation of rivaroxaban in pharmaceutical formulation

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Anion chromatography using on-line recycled eluents

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

Guidance for Industry

INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND BIO-SCIENCE

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

What is Eluent Generation?

Analytical Test Method Validation Report Template

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Determination of Calcium and Magnesium in Brine

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

How To Test For Contamination In Large Volume Water

Dissolved and precipitated oxalate

Analytical Methods for Cleaning Validation

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Transfer of a USP method for prednisolone from normal phase HPLC to SFC using the Agilent 1260 Infinity Hybrid SFC/UHPLC System Saving time and costs

International Journal of Pharma and Bio Sciences V1(2)2010

International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

GUIDELINES FOR THE VALIDATION OF ANALYTICAL METHODS FOR ACTIVE CONSTITUENT, AGRICULTURAL AND VETERINARY CHEMICAL PRODUCTS.

Dionex IonPac AS19-4µm

All the prepared formulations were subjected for following. evaluation parameters and obtained results were showed in Tables 6.3 &

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

Research for leachables of nuclear grade cation exchange resin

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

ICH Topic Q 2 (R1) Validation of Analytical Procedures: Text and Methodology. Step 5

Enhanced Organic Precursor Removals Using Aged Filter Media Page 1. Enhanced Organic Precursor Removals Using Aged Filter Media

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Articaine & Epinephrine Injection according to USP method

Tamsulosin Hydrochloride Capsules

Implementing New USP Chapters for Analytical Method Validation

A Complete Solution for Method Linearity in HPLC and UHPLC

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

NUTC R304. Use of Absorption Mechanisms to Decrease Heavy Metal Mobility

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

NITRIC OXIDE and NITROGEN DIOXIDE 6014

SUCRALOSE. White to off-white, practically odourless crystalline powder

Design of Experiments for Analytical Method Development and Validation

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

High Performance Thin Layer Chromatographic Method for Estimation of Cefprozil in Tablet Dosage Form

for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC)

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

S olid Ph ase Extraction (SP E) Method:

Vitamin C quantification using reversed-phase ion-pairing HPLC

Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method)

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

VALIDATION OF HPLC METHOD FOR DETERMINATION OF DOCOSAHEXAENOIC ACID (DHA) IN MULIIVITAMIN CAPSULE DIAH WIDOWATI*, ROS SUMARNY, ESTI MUMPUNI

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

Automation of Sample Preparation in Ion Chromatography

The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection

Journal of Chemical and Pharmaceutical Research

Overview. Purpose. Methods. Results

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

TEST REPORT: SIEVERS M-SERIES PERFORMANCE SPECIFICATIONS

LACHAT METHOD NUMBER D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately g CN/L g CN/L. 09e

Analytical Test Report

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

4.1 Stoichiometry. 3 Basic Steps. 4. Stoichiometry. Stoichiometry. Butane Lighter 2C 4 H O 2 10H 2 O + 8CO 2

Carolina s Solution Preparation Manual

AMINO ACID ANALYSIS By High Performance Capillary Electrophoresis

IC-MS and LC-MS Determination of Ionic Liquids, Counterions, and Impurities

Assay Development and Method Validation Essentials

Applying Statistics Recommended by Regulatory Documents

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Amino Acid Analyzer L-8900

ALS TRIBOLOGY Engine Coolant Reference Guide

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

MOISTURE (Karl Fischer, Buffered)

QUALANOD SPECIFICATIONS UPDATE SHEET Nº 9 Edition page 1/5 COLD SEALING PROCESS

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

Determination of Caffeine in Beverages HPLC-1

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Center for Drug Evaluation and Research (CDER) Reviewer Guidance' Validation of Chromatographic Methods. November 1994 CMC 3

Chemical analysis service, Turner s Green Technology Group

Validation and Calibration. Definitions and Terminology

Using the AS Automated Sampler in the Simultaneous, Sequential, and Concentrate Modes

Technique of Monitoring Dioxins in Flue Gas from MSW Incinerators using Dioxin Precursor Analyzer

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

ERDOSTEINE - MONOGRAPH.

Validating Methods using Waters Empower TM 2 Method. Validation. Manager

Transcription:

Cantaurus, Vol. 7, 5-8, May 1999 McPherson College Division of Science and Technology Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate Janet Bowen ABSTRACT Sulfate is used in the Pharmaceutical Industry to seal the surface of type one glass and is readily water-soluble. The widely used method for detection of Sulfate is a qualitative test based on a precipitation. New separation and detection capabilities now in use will allow the industry to use Ion Chromatography (IC) to quantitate residual sulfate at sub-ppm levels. The method presented is robust and linear from 125% to 25% of 1ppm sulfate. Keywords: Ion Chromatography, Anion Suppressor, Conductivity detector INTRODUCTION Pharmaceutical companies utilize type 1 glass in the production of many of their drug products. This glass is sometimes treated with ammonium sulfate to seal the pores of the glass and prevent leaching of the materials within the glass into the solution. Prior to being filled with a drug product, the glass is processed by flushing with water. This process is to remove coatings and foreign materials. To assure the glass is clean enough for a drug product, it is tested for residual contaminants. The current test method used by the majority of pharmaceutical companies is the one referenced in the United States Pharmacopoeia (USP). The USP method is based on a precipitation reaction and is subjective (clarity of solution) and is a qualitative test. One cannot quantitate, "no more turbid than the blank". A quantitative analytical method used for detection of low levels of sulfur derivatives is desirable for testing the effectiveness of the glass washing process in the production of pharmaceuticals. This would provide results that could be used to calculate what the affects would be on unbuffered product. Some pharmaceutical products have excipients (sodium chloride) that contain known levels of sulfur contaminants and degradants while others do not. It is those products that do not contain sulfur derivatives that are of a major concern. Those products that do not contain some type of buffer, if filled in glass that contains sulfur residual, could experience changes to the compound. Changes include; ph shift, increased degradants, and precipitants (particulate matter). MATERIALS AND METHODS This study will involve the evaluation of the detection of Sulfate by ION Chromatography, to determine whether it will detect sulfate in the range of 1ppm or less and be suitable for use in a commercial laboratory environment. This IC method will be evaluated to determine if it will detect the sulfate ion, and provide reproducible/ validatable results. Materials Ion Chromatography Mobile Phase - Isocratic 1.8 mm Sodium Carbonate 1.7 mm Sodium Bicarbonate Regeneration Solution - 43.2 mn Phosphoric Acid Column DIONEX IonPac AS9-SC (250 x 4 mm) Detector Alltech 350 Conductivity Suppressor: Anion MicroMembrane Suppressor - AMMS-II Regenerating solution Pump - Waters Model 510 HPLC 0-6000 psi Mobile Phase pump - Spectra SYSTEM model P1500, by Thermo Separation Auto Sampler - Spectra System model AS3000 by Thermo Separation products Flow Rate 1.5 ml/min for nominal conditions both solutions Sample injection 100µ L Data was collected, processed, and printed using a PIONEX 50 MHz 486 PC, loaded with OS/2 for the operating system and PC1000 ver. 2.5 software for data analysis. All chromatograms were obtained at room temperature, and the temperature control in the unit was turned off. The target retention time is approximately 10 minutes, as listed in the DIONEX PRODUCT SELECTION GUIDE for determination of the anion, Sulfate. This retention time, during analysis, ranged from 10 to 14 minutes, depending upon the flow rate and concentrations of mobile phase and regeneration solution. Reagents and Solutions All reagents were analytical grade. All mixtures were prepared using high-purity deionized water. Water was prepared using a Milli-Q system (Millipore, Bedford, MA) and filtered through a 0.2 µm membrane filter. Deionizer readout at the time of preparation was NLT 18Ωcm. Mobile phase and regeneration solutions were

6 Cantaurus degassed under vacuum with stirring for NLT 15 minutes. A stock solution was prepared at a concentration of 200ppm SO 4, from NaSO 4. Dilutions were made from this stock solution for Linearity, Level of Detection, Robustness, and Level of Quantitation analysis. Separate solutions were prepared for the accuracy/recovery analysis. The following series of test will show that the method is acceptable to be used in the pharmaceutical industry. The pharmaceutical industry is required to Validate or certify the method will provided the required results accurately and repeatedly. The validation will consist of testing for, Linearity, Robustness, Limit of Detection, Limit of Quantitation and Accuracy /Recovery. Accuracy of the analytical procedure expresses the closeness of agreement between the value which is accepted either as a conventional true value or an accepted reference value and the value found. Sometimes termed trueness. Accuracy for the test will demonstrated by adding known amounts of analyte to sample or placebo formulation representing approximately75%, 100% and 125% of the total theoretical concentration of the analyte. The analysis will be performed in triplicate at each interval. The target average recoveries should be 98% to 102% of the theoretical concentration at each interval tested. The RSD should be <2%. The Linearity of an analytical procedure is its ability (within a given range) to obtain test results which are directly proportional to the concentration (amount) of analyte in the sample. To determine method linearity, at least 5 sample or standard solutions ranging from approximately 50% to 150% of the working concentration should be analyzed. The test results should be linear with respect to the concentration of the analyte with a correlation coefficient of not less than 0.99. The detection limit of an individual analytical procedure is the lowest amount of analyte in a sample which can be detected but not necessarily quantitated as an exact value. To establish the LOD, sequential dilution and analysis of samples of a known concentration. The LOD is the lowest concentration of analyte which gives a signal to noise ratio of not less than three. The limit of Quantitation of an individual analytical procedure is the lowest amount of analyte in a sample which can be quantitatively determined with suitable precision and accuracy. The Quantitation limit is a parameter of quantitative assays for low levels of compounds. Samples will be prepared to contain target concentrations of approximately 0.05%, 0.1% and 0.5% of the analyte and tested in triplicate. The robustness of an analytical procedure is a measure of its capacity to remain unaffected by small, but deliberate variations in method parameters and provides an indication of its reliability during normal usage. The solution concentrations will be shifted by 1%, the flow rates will be adjusted by ± 2 tenths. RESULTS The IC Suppressed conductivity method used in this experiment for the detection of SO 4 produced the following results. TABLE 1. Linearity/LOQ/LOD - tests were performed under nominal conditions (flow rate 1.5mL/min; regeneration solution 43.2 mn; mobile at phase Na 2 CO 1. 7mM and NaHCO 3 1. 8 mm, Linearity results Correlation coefficient = 0.990668 Y-intercept = 0.10002 Target conc ppm Calc Conc Ppm Avg. Resp % RSD 1.25 1.2019 2657570 4.0 1.0 0.9118 2016187 1.07 0.75 0.7608 1682374 2.41 0.50 0.5958 1311337 6.49 0.25 0.2785 612955 10.96 TABLE 2. ACCURACY/RECOVERY - tests were performed under nominal conditions (flow rate 1.5mL/min; regeneration solution 43.2 mn; mobile at phase Na 2 CO 1. 7mM and NaHCO 3 1. 8 mm, a the specified % of 1ppm. Sample chromatograms; See Figure 1 for 75%, Figure 2 for 100%, Figure 3 for 125%. Prep % RSD % Recovery A 125 0.21 153 B 125 0.88 195 C 125 0.97 153 A 100 1.51 222 B 100 0.58 208 C 100 0.29 180 A 75 0.48 226 B 75 0.89 302 C 75 0.49 224 TABLE 3. Robustness - each test required variations in sections of the methodology (the most efficient/accurate results were obtained from the slower flow rate at nominal solution concentrations). (RRT = Relative Retention Time; REC = Recovery) Where indicated, mobile phase (MP) is Na 2 CO 3 and NaHCO 3 regeneration solution (RS) H 3 PO 4. Data in table 3 are averages of three replicate injections. For Sample chromatograms, see figure 4 - MP @ 1.7/1.6 and RS @ 42.78; figure 5 -MP @ 1.9/1.8 and RS @ 43.63, figure 6 - flow @ 1.7ml/min, figure 7 - flow @ 1.3 ml/min. Method change RRT %RSD %REC

Low Levels of Sulfate Bowen 7 Method change RRT %RSD %REC All at nominal 11.862 1.07 91.8 Flow@1.7mL/ 10.499 1.38 89.0 min Sol at nominal Flow@1.3mL/ 13.73 10.0 94.9 min Sol at nominal Solutions @ 12.319 1.66 104 MP 1.7/1.6 mm and RS 42.78 mn Solutions @ MP 1.9/1.7 mm and RS 42.78 mn 14.273 0.216 104 Figure 2. Accuracy/Recovery test = 100% of a 1ppm Figure 3. Accuracy/ Recovery test - 125% of 1 ppm Figure 4. MP @ 1.7,1.6, and 42.7mN. Flow rate was at 1.5 ml/min. DISCUSSION Figure 1. Accuracy/Recovery test = 75% of a 1ppm The purpose of this project was to determine whether the stated method was capable of producing results in the range of 1 ppm of sulfate. The data collected show that the method is accurate, reproducible and validatible. Although results collected during the robustness showed variations, the statistics show the tests are acceptable, and these variations could be managed procedurally. The results collected during the Accuracy/Recovery study indicate that there could have been a solution preparation error resulting in recovery of greater than 100%. This test should be repeated.

8 Cantaurus Figure 5. MP @ 1.9,1.8, and 43.63. Flow rate was at 1.5 ml/min. Figure 7. MP @ 1.8,1.7mM, and 43.2mN. Flow rate was at 1.3 ml/min. to reduce the flow rate, because of the high % RSD calculated during that portion of testing. ACKNOWLEDGEMENTS A great thanks to all those who assisted in helping make this happen, and especially to those individuals and organizations listed: Mark Phillips, Mark Nauchtigal, Heather Meredith, Abbott Labs (HPD Mcpherson) LITERATURE CITED Analytical Chemistry,Vol.68, No.24, December 15,1996 Analytical Chemistry, Vol.67, No.20, October 15,1995 Figure 6 - MP @ 1.8,1.7mM, and 43.2mN. Flow rate was at 1.7 ml/min. The results collected during the Linearity study indicate the method is linear from 125% to 25% of 1ppm SO 4 from a 200 ppm SO 4 stock solution. The method appears to have an LOQ/LOD of @ 0.25ppm SO 4, although with slight adjustments in the sensitivity of the instrument lower quantities could possibly be detected accurately. The method has proven robust with modifications to increased/decreased flow rate, increase/decrease mobile phase concentration, and increase/decrease regeneration solution concentration. To optimize the method, an increase in flow to 1.7 or greater, and a lower concentration of mobile phase/regeneration solution could be implemented. It is not recommended Analytical Chemistry, Vol.67, No.13, July 1, 1995 Analytical Chemistry, Vol.67, No.5, March 1,1995 LC-GC Vol 6 No. 6 Standard Practice for Liquid Chromatography Terms and Relationships ed. Jan.15, 1992 American Laboratory, Vol. 30 Number 21: Ion Chromatography: A historical perspective, pg.56-62. Modern HPLC Method Development - LCResources inc. Walnut Creed, CA.

Skoog-Holler-Nieman: Principles Of Instrumental Analysis 5 th ed. Sample Chromatograms Low Levels of Sulfate Bowen 9