http://www.homebrewpower.co.uk Building A Battery Bank



Similar documents
HM-W536 Install Guide

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

13 Watt PORTABLE SOLAR POWER KIT

Conventional Fire Detection and Extinguishant Control System Specification

Using battery test equipment with asset management software. Megger is a registered trademark

Inverter / Charger Installation General Operations and AC and DC Connections

PowerGem Pro Uninterruptible Power Supply

How To Use A Power Supply Unit (Upu)

Table of Contents TO OPERATE THE 12.0 VOLT POWER PACK: THIS OPERATES ONLY OFF THE UNIT S RECHARGEABLE BATTERY, NOT OFF YOUR VEHICLE S BATTERY.

Online UPS. PowerWalker VFI 1000R/1U

If you accidentally get battery acid on your skin, flush it with lots of water

Memcom Emergency Telephone

CB200W Water Leak Detection Panel Application Guide

EKOS Cart. Instructions for Use

PV (photovoltaic) Basics There are generally two types of PV systems. The first and easiest (though the least flexible) is a grid tie system where

Manual. Solar Fountain Mobile Phone Charger

Instruction manual. Electrobloc EBL 100-2

SPECIFICATIONS. Recommended Battery sizes (Maintenance) AUTOMOTIVE CCA CCA MARINE MCA MCA DEEP CYCLE 17 55Ah 17 80Ah

UPS Applications and VRLA Battery Sizing

User s Manual AURORA 1.2K/2.2K

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Home Solar Kit Owner s Manual. Model: HS

BE SAFE AND SECURE. Landmark Security... giving you peace of mind.

Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation

car + boat Box Contents x2 x _DC16_CAR_BOAT_OPSMAN.indd 1 29/7/08 15:27:01

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Model 1756 Test Lead Kit

875 Dearborn Drive Columbus, Ohio Tel: (614) Fax: (614)

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

User s Manual Before using the inverter, you need to read and save the safety instructions.

User Manual 使 用 者 指 南. Aputure Manufacturing Authority

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Factors to Consider When Developing an Evacuation Plan

Contact Center CC-165 INSTALLATION & USER'S GUIDE

Charge Regulator SCR 12 Marine

12V/15.0A SLA Battery Charger Specification

8 coil stator 11 coil stator

10000HXL31/15000HXL31/20000HXL31

Mobile Data Power Model: MDP-25

What is a multimeter?

Switch Mode, Automatic, Lead Acid Battery Charger 3 Stage (IUoU)

The Quest for Energy Efficiency. A White Paper from the experts in Business-Critical Continuity

Emergency Response. Prepared for Fire Service, Law Enforcement, Emergency Medical, and Professional Towing Personnel by American Honda Motor Co., Inc.

conventional system operation

rpsa FIRE PROTECTION ENGINEERS

magnetronic GmbH Kreuzhofstr München Tel.: 089/ Fax: 089/ Battery control system DCC 6000

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

Self Monitoring Power Supply (BPSM)

Height w/o Terminals (in)

Specification Requirements DBL 700MX and 1000MX Series UPS

3 WATT LED SPOTLIGHT Model No. SLM

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

4KVA/5KVA Parallel Installation Guide

Carefree Sealed Lead Acid (SLA) MSDS

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

BATTERY SERVICE. This Automotive Series BATTERY SERVICE has been developed by. Kevin R. Sullivan. Professor of Automotive Technology Skyline College

AJ s Technical Tips: Designing a Small Solar PV System Part IV; Selecting Wires for the System

GSM Gate Opener GSM Remote Switch RTU5015 User Manual

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

AUTODIALLER / QUICKDIALLER - SA132

Installation Instructions for Alarm Module Kit A043F059

How To Plan Out An Array Of Solar Panels

TRADE PRODUCTS Electronic systems for recreational vehicles Supplying controlling indicating

1. Components. The first component needed is one or more Solar Panels. They supply the electricity and charge the batteries.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

AMP Power Series Connectors

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

400 Amp Rechargeable Jump Start System RAC-HP082

Input module, input/output module

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

BATTERY BASICS. This Automotive Series 12-volt Lead Acid BATTERY BASICS has been developed by. Kevin R. Sullivan

SIT Sports. Safety Tracking System Manual WRC 2015

Residential Gateway (RG) Battery Backup

Battery Power Inverters

Shunt lock function 3066

LOOK to us because we re. Advice for your domestic security. nsi.org.uk

Voice Over IP Digital Phone Concerns with Security and Fire Alarm Communications Systems

CUTES Solar Power System

HI400. Owner s Guide

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Backup Sump Pump Systems. 1 NEXT

The Basics of Solar Power for Producing Electricity An excellent place to start for those just beginning. The basics of solar power: 1000 W/m²

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Electroluminescent (EL) Parallel Panels

Ontario Electrical Safety Code 25 th Edition/ 2012

Home Solar Kit Owner s Manual. Model: HS

Product Specification instalert Rapid Messenger Variable Message Sign

Using your LED Plus keypad

DE1600 DSA E-Series iscsi Disk Arrays. Installation Manual

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

Single Day Alarm Clock with. Bluetooth and USB Play-through

Harris County, Texas. Extra Low Energy LED DC Cabinet System Alternative Energy System

Manual for Fire Suppression & Methane Detection System

Charger Output AC Ripple Voltage and the affect on VRLA batteries

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

3000W Power Inverter

Transcription:

http://www.homebrewpower.co.uk Building A Battery Bank

Batteries! In this section I will try and explain some do s and don ts of selecting / obtaining your batteries, which in my opinion are going to be the most important part of your system, after all, they are going to store the fruits of your labour Electricity) Please note, the batteries you use are ultimately going to make or break your homebrew system, if at all possible, get the best you can possibly afford! The batteries to use are ones that are maintenance free (SLA or Sealed Lead Acid) they should be Deep Cycle batteries designed for deep discharge i.e. Marine batteries, Golf cart batteries or Electric vehicle batteries. Try and avoid if possible car / van batteries, they are Wet batteries, not designed for deep cycle charging & discharging plus they Gas when being charged, the gas is extremely flammable and ventilation will be required if you opt for these types of batteries, you have been warned! The best batteries I could recommend would be the USA brand called Hawker SLA s, they out rate any battery I know of and everyone raves about them, me included. They are however expensive but below I am listing you some suggestions for obtaining batteries that are in good condition for a good price or in my case for free! Battery Sources 1. Commercial fire alarm panels 2. Central battery systems for emergency lighting systems 3. Uninterrupted power supply units 4. Golf courses (With electric golfing carts) Further battery sourcing information You will have good luck contacting the likes of commercial electrical contracting companies, look in the yellow pages for ones near to you, ask to speak to one of their Electrical Engineers, tell them a little about what you are doing and ask them if they have any batteries coming out from upcoming 2

refurbishments or contract jobs they currently have secured. Companies like this have to pay to dispose of batteries and will be more than happy to drop them off for you as and when they come across some, which no doubt will be sooner rather than later! Any large commercial company with sizable premises will require to have their batteries for Fire alarm, UPS, Emergency lighting systems replaced at least once every 3 years, these batteries will have been properly maintained, charged at the optimum rates and more than likely never deep discharged in there short life, this means tip top batteries for free! Any further questions you have on batteries molesmail@gmail.com I will do my best to help you out. 3

My Homebrew battery bank All the batteries you see above in my battery bank where acquired for nothing; they are all in great condition and as new! Details: 16 x Hawker SBS 60 s @ 12VDC 60AH Deep cycle SLA s 10 x Yuasa s @ 12VDC 48AH Deep cycle SLA s All wired in parallel to provide 12VDC @ 1440AH 4

Choosing a battery bank operating voltage??????? I will not go into much detail on this subject as it is a massive debate amongst likeminded people, 12, 24 or 48VDC? Below are the pros and cons of each system, please choose your own to best suit your own needs. 12VDC System Current draw can be huge Safe to work on without risk of shock Voltage drop from batteries to inverter mean large cabling Vast amount of 12VDC accessories available for your system 24VDC System Better current draw than 12VDC system Safe to work on without risk of shock Better voltage drop characteristics than 12VDC system Only commercial wagon accessories available 48VDC System Lowest current draw compared with other systems Risk of electric shock when working on live system Lowest voltage drop characteristics Hard to source electrical accessories for 48VDC systems 5

A note on DC! DC stands for Direct Current it is a pure form of current that unlike AC Alternating Current does not fluctuate. When working on any electrical system, safety must be of paramount at all times but even more so with DC systems, if you where to get a shock from a DC system 48V and above, your muscles will react by seizing, just like a cramp, your muscles will contract and lock, the current will block out all signals from your brain which will render you unable to let go. I have been there and walked away, DO NOT under any circumstances take any chances, and my bet is you will not be as fortunate as I was. Electricity can and will KILL, please play safe. 6