BRANCH SOLUTION. Automatic fire extinguishing systems for paint spraying plants. Safe for certain.



Similar documents
BRANCH SOLUTION. Fire protection for wind turbines. Safe for certain

GAS EXTINGUISHING SYSTEMS INERT GAS EXTINGUISHING SYSTEMS. Argotec Liquid Argon Gas Extinguishing Technology (LAR)

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

Risk Engineering Guideline

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

Fire and Explosion Protection for Stationary Extraction Plants

Alarm and Detection/Suppression

How intelligent must an extinguishing solution be to keep fire virtual?

Conventional Fire Detection and Extinguishant Control System Specification

Winnipeg Fire Department Fire Prevention Branch

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

HEAVY-DUTY HAND CUTTING TORCHES AND ACCESSORIES. Page 1 Version no.: V

Control and Indicating Equipment

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

Maximum uptime and optimum fire safety for your data center

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

Maximum uptime and optimum fire safety for your data center

EXHIBIT A SCOPE OF WORK

Class A - Wood, paper, cloth, trash, plastics Solid combustible materials that are not metals. (Class A fires generally leave an Ash.

Safe Operating Procedure

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

INERGEN - EXTINGUISHING SYSTEMS

Early Fire Detection & Condition Monitoring

Spray Booth Guideline

FIRE SAFETY FOR OFFICE WORKERS

Automatic fire-extinguishing systems for commercial cooking

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Fire Safety Requirements for Child Care Centre

NMSU FIRE DEPARTMENT Commercial Kitchen Fire Suppression Worksheet

CO 2. fire extinguishing systems

GUIDELINES - Gas Inspection Regulations 1. Recommendations for camping site owners

On-Line Fire Extinguisher Training

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;

Notes. Material 1. Appropriate Flammable Liquids

Hydraulic control unit series

Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1

This is how you solve burning problems on forklift trucks and construction machines

Fire protection in archives and storage vaults

GUIDELINE FOR SAFETY IN THE HANDLING OF FLAMMABLE LIQUIDS

Compliance Schedules and Building Warrant of Fitness

Fire Protection on Site: The VdS Inspection Services

ENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

Static Spark Ignites Flammable Liquid during Portable Tank Filling Operation

Operating instructions

Natural Gas Emergencies

Important Ontario Fire Code Information for Building Owners in the City of Windsor

Gas Standards and Safety. Guidance Note GAS INSTALLATIONS SUPPLIED FROM BIOGAS FACILITIES - ACCEPTANCE REQUIREMENTS GAS ACT 2000

Welding, Brazing & Cutting Guidelines

FIRE EXTINGUISHER TRAINING

BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS

2014 Limited Plan Submittal Checklist

Fire Protection Options for Data Centres

ECHM Recommendations for Safety in multiplace medical hyperbaric chambers

1.0 Purpose Definitions Hot Work Operations. 5

FLA S FIRE SAFETY INITIATIVE

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No

A Practical Guide to Free Energy Devices

Industry Sector. Zug (Switzerland), May 26, 2010

ngenieros Ingenieros Asociados De Control S.L.

and Extinguisher Training

Guardian Fire Safety Solutions FIRE RISK CONTROL IN WELDING FUME EXTRACTION SYSTEMS

Ethanol Vehicle and Infrastructure Codes and Standards Citations

Fire Safety Log Book

WASTE Application Form - Dublin Waste to Energy SECTION J ACCIDENT PREVENTION & EMERGENCY RESPONSE

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

PLAN REVIEW GUIDE FOR FIRE ALARM

Firewall. Propane flame projector Safety instructions and operating manual

This leaflet provides information on

Vehicle Fire Suppression Systems COPY ONLY

Take care with oxygen Fire and explosion hazards in the use of oxygen

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Fire Extinguishers Water Extinguishers

READ FIRST. Confined Space Entry Procedure. San José State University Environmental Health and Safety. Confined Space Entry Procedure

COMITÉ EUROPÉEN DES ASSURANCES

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

FIRE SAFETY ONLINE TRAINING

Overview of Hotel Fire Safety Requirements

Fire Pump Plan Review March 2010

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

WORKING IN CONFINED SPACES GUIDELINES

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

Element D Services Plumbing

During Various Aluminum Fabricating Operations

CIBSE Guide M: Maintenance engineering and management Statutory compliance legislation and guidance

Annual Fire Safety Training Module

GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS

Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations

Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

FIRE RISK ASSESSMENT IN GERMANY - PROCEDURE, DATA, RESULTS -

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

Aspirating Smoke Detectors 420 Series Special environments require very early detection

ICC CODE CORNER 2012 IFC Code & Commentary

EFSN Training i Module Minutes

Guidance for Those Who Use and Store Gas Cylinders

SL280UHV SERIES GAS FURNACE WARNING

Transcription:

BRANCH SOLUTION Automatic fire extinguishing systems for paint spraying plants Safe for certain.

ISK IDENTIFYING With the extreme high degree of automation in painting technology, the risk of fire has also increased. If sources of ignition are not already detected in the origination phase and nipped in the bud, the result can be a devastating fire. The protection of human life and of facilities therefore necessitates the use of special fire protection systems, which are specially adapted to the respective process technology. Combustion of the spray mist at the powder gun or atomizer, especially with electrostatic painting processes. Coated parts which are poorly grounded or not grounded. Deposits of coating materials or paints in booths, filters or air scrubbers. Fire risks in painting technology: Use of flammable paints or coating materials. Formation of explosive concentrations of paint or coating materials.

BRANCH SOLUTION Reliable all-round fire protection The fire protection concept for paint spraying plants focuses on the extremely fast responding fire extinguishing system. It automatically detects acute fire hazards and fights fires at its incipient phase in several stages, depending on the respective combustion speed, with gaseous extinguishants or water spray. Parallel to the extinguishing process, it initiates important control actions, e.g. to interrupt the supply of power, paint, air or solvents, to switch off high voltage, machines, robots, conveyors and ventilation systems, to close fire doors and ventilation flaps and to activate the alarm organization. In order to develop a customized and effective fire protection concept, all conditions in the environment must be taken into account. SOLUTION MINIMAX PROVIDES RELIABLE FIRE PROTECTION The protection is suitable for: electrostatic powder-coating and wet painting systems systems with paint robots manual and automatic paint spraying plants paint ovens and exhaust zones ventilation ducts and paint recovery systems Inlet for workpieces of a powder coating booth Shuttle non-return valve block for extinguishant release into spraying equipment

HE COMPO FOR RELIABLE FIRE PROTECTION Painting processes in particular are subject to the formation of open flames and the rapid spread of fire. Therefore, optical radiation detectors are recommended for first line fire detection, since they can already detect sources of ignition. These fire detectors can be positioned to monitor especially hazardous zones or the painting plant in its entirety. In order to provide optimum protection for all applications, fire detectors of various types and sensitivities are used; these can also be adapted for specific types of applications. frequency. If the signals received by both channels correspond to the saved values, an alarm signal is sent to the fire detection control panel. Spark detectors Spark detectors are used for special applications, e.g. for monitoring of ducts. They are installed only in dark, closed systems. Their signal receiving circuitry is similar to that of the flame detector; however, they already respond to the slightest infrared radiation and send the converted signal without delay to the fire detection and control panel. 2-channel flame detector Both channels of this detector operate in different spectral ranges of infrared radiation. Possible signals are compared with the stored typical patterns of a hostile fire, e.g. radiation intensity or flicker Flame detector FMX35xx with air flushing device This detector is available in two variants, either as a nondelayed version for local protection or with a time delay for room protection. Each of them can also be obtained as an explosion-proof model. Spark detector FUX3001 The development and planning of fire extinguishing systems for paint spraying systems takes place in close cooperation with manufacturers and operators, and makes use of the large store of knowledge acquired by Minimax in the implementation of these and comparable systems over the course of decades.

NENTS BRANCH SOLUTION Detectors with advanced fiber optics attachments These are used for monitoring areas where flame detectors and spark detectors cannot be installed directly in the hazard zone due to limited space or in case of thermal or electromagnetic influences. Heat detector WMX1000 F 60/90 Push-button release These are installed for the manual activation of local protection and room protection systems along the escape routes. Fire detectors for explosion hazard zones The automatic detectors comply with Protection- Standard IP65 and therefore fulfill even under extreme conditions at the installation location the most important requirement for trouble-free operation. If the detectors are carried out as Protection-Standard Ex-I (inherent safety) they can be used in potentially explosive areas of zones 1 and 2, 21 and 22. These approvals correspond to the latest requirements for equipment in explosion hazard zones (ATEX). FMX3100 (Ex) L1 or FUX3200 L1 UEWA Heat detectors These are recommended as an additional safety measure, since they enable more extensive monitoring in combination with flame detectors. For example, adjoining zones can also be included. Push button release DMX Heat detector WMX 3111 FS with rigid or flexible sonsor

HE COMPO FOR RELIABLE FIRE PROTECTION Fire detection control panel analysis and control All important components of the automatic fire extinguishing systems for paint spraying plants, such as detectors, activating elements and alarm units, are connected with the fire detection and extinguishing control panel. In the event of an alarm, the fire detection and control panel registers and verifies the signals sent by the detectors, issues an alarm and activates the extinguishing system and the pre-programmed control functions. Therefore, the following features are extremely important for the protection of paint spraying plants from fire: Alarm analysis non-delayed (local protection) or after alarm analysis (room protection). Programmable safety circuits, e.g. 2-detector or 2-zone dependency Monitoring of the extinguishing system for operational reliability and extinguishant supplies. Control of the extinguishing system and the alarm units Fire detection and control panel FMZ 5000 The extinguishant control can be programmed individually: Use of extinguishant only during the detector response time also with set over-run time (e.g. in case of danger of re-ignition) Total flooding via pulse triggering of a cylinder system Total flooding via electronic extinguishant control of a low pressure system Control functions for Interruption of supply of powder, paint, air and solvents Shut-down of highvoltage lines, machines, conveyors and ventilation systems Closing of fire protection flaps and doors. The extinguishing system The Argotec extinguishing system, which uses carbon dioxide (CO 2 ), argon (Ar) or nitrogen (N 2 ) as extinguishants, provides for the optimum protection of paint spraying plants The gases extinguish the fire leaving no residue and therefore cause no subsequent damage. The extinguishants used reduce interruptions in operation to a minimum in the event that an room protection system is activated. If a local protection system is activated, interruptions in operation can even be prevented completely under certain circumstances. Minimax holds approvals for both the individual system components and the complete systems. In addition, Minimax is recognized as a manufacturer and installer of fire extinguishing systems by the Verband der Schadenversicherer e.v.

NENTS BRANCH SOLUTION The extinguishant is supplied to the protected area by means of a fixed pipe network with open nozzles. If it is necessary for fire protection reasons to release the extinguishant via paint spraying system components, the extinguishant is supplied via hoses. The extinguishants The extinguishing effect of the gaseous extinguishants is due to the fast displacement of oxygen from the source of the fire, which smothers the fire suddenly. Since they not only extinguish the fire leaving no residue, but also do not conduct electricity, they are especially suitable for the protection of electrostatic paint spraying plants. The gaseous extinguishants are provided in compressed gas cylinders, the number of which can be adapted to the required quantity of extinguishant. The advantage of carbon dioxide over argon and nitrogen is that it is stored liquefied under pressure and therefore requires very little storage space. The extinguishing process Both in automatic detection, e.g. via flame detectors, and in manual activation, the fire detection and extinguishing control panel provides for the initiation and control of the extinguishing process. An acoustic alarm announces the flooding. If necessary for organizational reasons, the actual extinguishing process does not begin until after a specified pre-warning time has expired. The extinguishing gas is fed into the flooding zone via the pipe network, after which it emerges from the nozzles to displace the oxygen from the source of the fire. Booth extinguishing systems In addition to the fire extinguishing installations described above for paint spraying areas, total flooding systems should be provided for the protection of painting and powder-coating booths. These systems fulfill all the requirements for protecting the entire booth including corresponding areas. For this application Minimax also offers customized and economical system solutions. For some protection concepts, the Minifog fine spray extinguishing system can be used for room protection as an alternative to the Argotec extinguishing system. Extinguishant cylinders for gun- and filter protection Cylinder bank for cabin extinguishing system

DVANTAGE OUR COMPETENCE Fire extinguishing systems for painting technology an important factor in the overall fire protection concept Despite the importance of a fire extinguishing system, it can of course only be part of a comprehensive fire protection concept. For optimum protection of the entire area, planning must be preceded by a risk analysis and evaluation. In order to implement a comprehensive fire protection concept, Minimax offers a complete fire protection program: from fire extinguishers to fire and gas detection systems, sprinkler systems and stationary fire extinguishing systems with gaseous extinguishants and structural fire protection. Competent advice and special engineering allow us to find an individual solution for every problem, at a price that is affordable. Approved, recognized and, often for good reasons, provided Minimax fire extinguishing installations for paint spraying systems consist of tried and tested VdS-approved system components that can be adapted for the individual facilities. The following European standards require the use of extinguishing systems: Wet paint spraying systems: EN 50176 Automatic electrostatic spraying installations for flammable liquid spraying material EN 12215 Spray booths for application of organic liquid coating materials Powder-coating systems: EN 50177 Automatic electrostatic spraying installations for flammable coating powder EN 12981 Spray booths for application of organic powder coating material In Germany the design of booth protection systems (total flooding) and local protection systems is regulated by the Verband der Schadenversicherer e.v. in the directive VdS 2093. In addition, the BG safety regulation BGI 764 Electrostatic Spraying prescribes the installation of extinguishing systems in electrostatic painting facilities. 24-hour service and maintenance The Minimax fire protection service is available 24 hours a day in case of emergency. Experienced service technicians provide fast, reliable and competent assistance. Minimax service does not end with the final inspection of the fire extinguishing system and introduction to it. A maintenance contract with Minimax puts the burden of responsibility on us and reduces your work load. Because only regular maintenance and repairs by competent specialists can ensure the constant operational readiness of the extinguishing system. Minimax GmbH & Co. KG Industriestrasse 10/12 D-23840 Bad Oldesloe Phone: +49 (0) 45 31 8 03-0 Fax: +49 (0) 45 31 8 03-2 48 E-mail: info@minimax.de www.minimax.de Nr. S 89201 AL10e_01/ 04.04/3/04.04/ HMB Printed in Germany For detailed information, please refer to the Minimax product sheets.