Monitoring FibreCAT CX systems with ServerView Operations Manager



Similar documents
ServerView Inventory Manager

Installation ServerView ESXi CIM Provider V6.12

ServerView Integration Pack for Microsoft SCCM

English ETERNUS CS800 S3. Backup Exec OST Guide

ServerView System Monitor

Monitoring of VMware-based PRIMERGY Servers with ServerView

User Guide - English. ServerView Suite. DeskView and ServerView Integration Pack for Microsoft SCCM

Administrator and User Guide - English. StorMan Monitor V6.0. ReadMe. Edition February 2015

Setting Up a Unisphere Management Station for the VNX Series P/N Revision A01 January 5, 2010

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)

ServerView Suite ServerView Operations Manager V5.0

ServerView Event Manager

ServerView Operations Manager V7.10

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

EMC CLARiiON PRO Storage System Performance Management Pack Guide for Operations Manager Published: 04/14/2011

ServerView Agents V7.10 for Windows

eg Enterprise v5.2 Clariion SAN storage system eg Enterprise v5.6

Deploying SAP on Microsoft SQL Server 2008 Environments Using the Hitachi Virtual Storage Platform

ServerView Online Diagnostics

SiI3132 SATARAID5 Quick Installation Guide (Windows version)

How To Install Outlook Addin On A 32 Bit Computer

EMC Navisphere Manager ADMINISTRATOR S GUIDE P/N REV A12

FUJITSU Software ServerView Suite ServerView Installation Manager

Enterprise Manager. Version 6.2. Installation Guide

Getting started with 2c8 plugin for Microsoft Sharepoint Server 2010

Fibre Channel HBA and VM Migration

Direct Attached Storage

Overview of ServerView Windows Agent This chapter explains overview of ServerView Windows Agent, and system requirements.

How To Use Visualsan On A Server With A Memory Card (For A Non-Procedure)

StarWind iscsi SAN & NAS: Configuring HA Storage for Hyper-V October 2012

User Management in ServerView 6.30

Server Sentinel Monitored Server

Foglight. Managing Storage in Virtual Environments Installation and Configuration Guide

BusinessObjects Enterprise XI Release 2

Technical Notes P/N Rev 01

Migrating MSDE to Microsoft SQL 2008 R2 Express


HP StorageWorks Command View EVA user guide

Configuring and Monitoring Hitachi SAN Servers

Nimsoft Monitor. dns_response Guide. v1.6 series

Enterprise Manager. Version 6.2. Administrator s Guide

Organization Name National Institutional Facilitation Technologies (Pvt.) Ltd. Business Division Name Information Security Solutions (NIFTeTRUST)

The Evolved Office APPLICATION PLATFORM REQUIREMENTS. Release: 16.0

XenClient Enterprise Synchronizer Installation Guide

AX4 5 Series Software Overview

SAS 9.3 Foundation for Microsoft Windows

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

Using SMI-S for Management Automation of StarWind iscsi SAN V8 beta in System Center Virtual Machine Manager 2012 R2


LifeSize Control Installation Guide

TANDBERG MANAGEMENT SUITE 10.0

Integration Guide. Microsoft Active Directory Rights Management Services (AD RMS) Microsoft Windows Server 2008

Studio 5.0 User s Guide

Matisse Installation Guide for MS Windows. 10th Edition

Section 1: Preface Introduction... 1 Users... 1 Assumptions... 2 Other Resources... 2 Conventions... 2 Icons... 2 Text... 2

This document details the following four steps in setting up a Web Server (aka Internet Information Services -IIS) on Windows XP:

Network Monitoring. SAN Discovery and Topology Mapping. Device Discovery. Send documentation comments to

Deploying Windows Streaming Media Servers NLB Cluster and metasan

SMART Vantage. Installation guide

StarWind iscsi SAN & NAS: Configuring HA Shared Storage for Scale- Out File Servers in Windows Server 2012 January 2013

Sentinel Protection Installer Version (Windows) ReadMe

CA Nimsoft Monitor. snmptd Guide. v3.0 series

ServerView Operations Manager V7.10

INSTALLATION GUIDE. AXIS Camera Station

VMware for Bosch VMS. en Software Manual

Package Contents. D-Link DSN-3200/3400 Installation Guide. DSN-3200/3400 xstack Storage Area Network (SAN) Array. CD-ROM with User Guide.

Compuprint 4247 Serial Matrix Printers

Bosch Video Management System High availability with VMware

Change Manager 5.0 Installation Guide

Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide

INSTALLING MICROSOFT SQL SERVER AND CONFIGURING REPORTING SERVICES

StarWind Virtual SAN Installation and Configuration of Hyper-Converged 2 Nodes with Hyper-V Cluster

Secure Agent Quick Start for Windows

StarWind SMI-S Agent: Storage Provider for SCVMM April 2012

Monitoring the Network

StarWind iscsi SAN & NAS: Configuring HA File Server on Windows Server 2012 for SMB NAS January 2013

Supplement I.B: Installing and Configuring JDK 1.6

DP-313 Wireless Print Server

RSA Security Analytics

Core Protection for Virtual Machines 1

Installing Management Applications on VNX for File

Package Contents. D-Link DSN-3200/3400 Installation Guide. DSN-3200/3400 xstack Storage Area Network (SAN) Array. CD-ROM with User Guide.

Guide to Installing BBL Crystal MIND on Windows 7

Exclaimer Alias Manager for Exchange Deployment Guide - Exclaimer Alias Manager for Exchange Outlook Add-In

StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability storage with Windows Server 2003 and 2008

IBM TSM for SharePoint 6.1 VSS Backup and Restore Solution Guide IBM System Storage DS6000 & DS8000 with DocAve

Installing the Microsoft Network Driver Interface

Using SQL Reporting Services with Amicus

Crystal Reports Installation Guide

Migrating the ASAS Database Administrator s Notes

ION EEM 3.8 Server Preparation

StreamServe Persuasion SP4

October, Install/Uninstall Xerox Print Drivers & Apps Best Practices for Windows 8, 8.1, and 10 Customer Tip

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

Signiant Agent installation

InfoPrint 4247 Serial Matrix Printers. Remote Printer Management Utility For InfoPrint Serial Matrix Printers

StarWind iscsi SAN Software: Using with Citrix XenServer

AMD RAID Installation Guide

DUKANE Intelligent Assembly Solutions

Video Administration Backup and Restore Procedures

Transcription:

User Guide - English FUJITSU Software ServerView Suite Monitoring FibreCAT CX systems with ServerView Operations Manager Edition May 2009

Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Feel free to send us your comments by e-mail to manuals@ts.fujitsu.com. Certified documentation according to DIN EN ISO 9001:2000 To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2000. cognitas. Gesellschaft für Technik-Dokumentation mbh www.cognitas.de Copyright and Trademarks Copyright 2009 Fujitsu Technology Solutions GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.

Contents 1 Monitoring FibreCAT CX systems with ServerView Operations Manager....................... 5 1.1 Preparing for FibreCAT CX monitoring............. 6 1.1.1 Software requirements...................... 6 1.1.2 Installing the software....................... 8 1.1.3 Activities after installation..................... 9 1.2 Monitoring FibreCAT CX systems with the Operations Manager...................... 12 1.2.1 Integrating FibreCAT CX in ServerView alarm management.. 12 1.2.2 Showing FibreCAT CX systems in the Operations Manager server list............................ 13 1.2.3 Showing detailed information on the FibreCAT CX system...................... 15 Index.................................... 25 FibreCAT CX

1 Monitoring FibreCAT CX systems with ServerView Operations Manager FibreCAT CX is an extensive Fibre Channel storage system that can be used both as a directly connected system and in Storage Area Network (SAN) environments. The advanced software functions permit uninterrupted operation with the very highest levels of availability and at the same time offer disaster protection. FibreCAT CX is versatile and can be deployed flexibly in distributed, multivendor environments and in computer centers. Upgrading capacity is a simple operation that can be performed online. The ServerView Operations Manager (referred to simply as the Operations Manager below) allows you to monitor FibreCAT CX storage subsystems (referred to simply as FibreCAT CX below) and to query detailed information on the individual FibreCAT CX systems. This document describes the preparations required to monitor FibreCAT CX systems with the Operations Manager: see Preparing for FibreCAT CX monitoring. how to use the Operations Manager to monitor FibreCAT CX systems and query detailed information on the FibreCAT CX systems: see Monitoring FibreCAT CX systems with the Operations Manager. FibreCAT CX 5

... preparations Monitoring with the Operations Manager 1.1 Preparing for FibreCAT CX monitoring To be able to monitor FibreCAT CX systems using the Operations Manager, a number of measures need to be implemented on the management server and on the individual FibreCAT CX systems. This section provides information on the following topics: Software requirements on the management server and the FibreCAT CX system. Installing the software on the management server and the FibreCAT CX system. Activities after installation. 1.1.1 Software requirements The following software requirements apply for monitoring FibreCAT CX systems with the Operations Manager. See Software required on the management server (Windows). Software required on the FibreCAT CX system. Software required on the management server (Windows) Microsoft Windows Server 2003 R2 SP2 The Windows SNMP services must be installed and configured. Sun Java Runtime Environment JRE ServerView S2 as of 4.50 or ServerView Operations Manager V4.70 ServerView Storage Manager (StorMan) Version 2.0 or later EMC SMI-S Provider Version 3.3.3 or later I Please note the version must be compatible with the version of ServerView Storage Manager (StorMan) used. The EMC SMI-S Provider is not supplied with the ServerView Storage Manager (StorMan). 6 FibreCAT CX

Monitoring with the Operations Manager... preparations Software required on the FibreCAT CX system Firmware: FLARE Version 19 or later MIB must be enabled (i.e. the SNMP service must be set up for both storage processors (RAID controllers)). You can set up the SNMP service for a storage processor either using Navisphere-CLI or under the Navisphere GUI. Proceed as follows for each storage processor (SP): Ê or Ê Enter the following command in Navisphere-CLI: naviseccli -h <SP-IP-addr> networkadmin -mib -enable Proceed as follows in the Navisphere GUI: 1. Double-click the FibreCAT CX system. 2. In the Navisphere Storage tree, navigate to the storage processor for which you wish to set up the SNMP service. 3. Right-click on this storage processor and then choose Properties from the context menu which then opens. The SP Properties dialog box opens. 4. In the Network tab, activate the enable processing of SNMP MIB read requests option. 5. Click OK to save your settings and close the dialog box. FibreCAT CX 7

... preparations Monitoring with the Operations Manager 1.1.2 Installing the software Proceed as follows: 1. Install the Sun Java Runtime Environment on your management server. You will find the software on the PRIMERGY ServerView Suite Software CD or you can download it at: http://support.ts.fujitsu.com/prim_supportcd/start.html 2. Install the ServerView Operations Manager on your management server. You will find the software on the PRIMERGY ServerView Suite Software CD or you can download it at: http://support.ts.fujitsu.com/prim_supportcd/start.html 3. Install ServerView Storage Manager (StorMan) on your management server. You will find the software on the PRIMERGY ServerView Suite Software CD or you can download it at: http://support.ts.fujitsu.com/prim_supportcd/start.html 4. Install EMC SMI-S Provider on your management server or on a server connected to the FibreCAT CX system via Fibre Channel: The software is available for downloading at: http://powerlink.emc.com Go to the page Support - Downloads and choose SMI-S Provider for Windows. 5. Check the Release Notice to see what combinations of versions are supported for the ServerView Operations Manager, ServerView Storage Manager (StorMan) and EMC SMI-S Provider. 6. Use the following commands to check the version and status of the Storage Manager (StorMan) installation on your management server: C:\Program Files\Fujitsu\StorMan\bin>storinfo and C:\Program Files\Fujitsu\StorMan\bin>storcheck 8 FibreCAT CX

Monitoring with the Operations Manager... preparations 1.1.3 Activities after installation After you have successfully installed the software, proceed as follows: 1. Refer to the README files for EMC SMI-S Provider and ServerView Storage Manager (StorMan) for information on any last-minute changes to these products. 2. Modify the configuration of the SMI-S Provider: a) In the configuration file.\emc\symcli\storbin\emcprovider.conf for the SMI-S Provider, change the line OslProv/com.emc.se.osls.osl.StorApi.database.discover = true to OslProv/com.emc.se.osls.osl.StorApi.database.discover = false I By default, the configuration file is located under: C:\Program Files. b) Restart the service CIM Object Manager - EMC_SMI_Provider to activate the modified configuration. 3. Ensure that the StorMan Service is started, since you will need to use Storage Manager (StorMan) commands in the following steps. 4. Add the name or the IP address of the server on which the EMC SMI-S Provider is running to the Storage Manager (StorMan) database: C:\Program Files\Fujitsu\StorMan\bin> storcfg cimom -add -name <name> bzw. C:\Program Files\Fujitsu\StorMan\bin> storcfg cimom -add -ip <ip> There are two different ways of proceeding from here: See The SMI-S Provider is connected to FibreCAT CX via Fibre Channel. See The SMI-S Provider is connected to FibreCAT CX via an IP connection. FibreCAT CX 9

... preparations Monitoring with the Operations Manager The SMI-S Provider is connected to FibreCAT CX via Fibre Channel Proceed as follows: 1. Ensure that at least one LUN (virtual hard disk) is assigned to the server. 2. Check whether the SMI-S Provider has been started: C:\Program Files\Fujitsu\StorMan\bin> storcfg cimom -show 3. Start detection of the FibreCAT CX systems connected via Fibre Channel in the CIM server: C:\Program Files\Fujitsu\StorMan\bin> storcfg cimom -showr 4. Check whether the CIM server has detected the FibreCAT CX system connected via Fibre Channel: C:\Program Files\Fujitsu\StorMan\bin> storcfg system -show I Start detection of any FibreCAT systems added subsequently in the CIM server as follows: C:\Program Files\Fujitsu\StorMan\bin> storcfg cimom -discover 10 FibreCAT CX

Monitoring with the Operations Manager... preparations The SMI-S Provider is connected to FibreCAT CX via an IP connection Proceed as follows: 1. Check whether the SMI-S Provider has been started: C:\Program Files\Fujitsu\StorMan\bin> storcfg cimom -show 2. Add the storage processors (SPs) of the FibreCAT CX system to the repository of the SMI-S Provider: C:\Program Files\Fujitsu\StorMan\bin> storemc -hostname <SMI-S Server> -add -sp <SPA>,<SPB> -cxuser <user> -cxpwd <pwd> I For -hostname, you must specify the same name in the storemc command as you specified in the storcfg cimom command ), in other words the server on which the EMC SMI-S Provider is installed. (see Activities after installation, step 4). 3. Check whether the CIM server has detected the FibreCAT CX system: C:\Program Files\Fujitsu\StorMan\bin> storcfg system -show I Add its storage processors to the repository of the SMI-S Provider to allow the CIM server to detect any further FibreCAT CX systems. This is done in the same way as described under step 2. FibreCAT CX 11

Server list Monitoring with the Operations Manager 1.2 Monitoring FibreCAT CX systems with the Operations Manager With FibreCAT CX systems, the ServerView Storage Manager (StorMan) software provides the necessary information to the ServerView Operations Manager to allow the information to be displayed in ServerView. A special storage subsystem icon indicates FibreCAT CX systems in the server list. 1.2.1 Integrating FibreCAT CX in ServerView alarm management In order to allow SNMP traps from the FibreCAT CX system to be passed to the Operations Manager, you must configure the Event Monitor using the Navisphere software. I You can specify what events are forwarded by specifying the error severity/error category. It is even possible to select individual events. 12 FibreCAT CX

Monitoring with the Operations Manager Server list 1.2.2 Showing FibreCAT CX systems in the Operations Manager server list This completes all preparations for monitoring FibreCAT CX systems using the ServerView Operations Manager. To add a FibreCAT CX system to the server list, add both storage processors for this system to the server list: 1. Open the Server Browser window in the Operations Manager. 2. Add the first storage processor to the server list: a) Enter the address of the first storage processor in the Server Address tab. b) Click the Search button. c) Leave the remaining default settings unchanged. d) Confirm your entries by clicking Apply. 3. Add the second storage processor to the server list: a) Enter the IP address of the second storage processor. b) Click the Search button. c) Change the name of the second storage processor. I It is necessary to change the name of the second storage processor because all objects configured for the server list must have unique names. d) Leave the remaining default settings unchanged. e) Confirm your entries by clicking Apply. FibreCAT CX 13

Server list Monitoring with the Operations Manager The FibreCAT CX system is then shown as follows in the server list: 14 FibreCAT CX

Monitoring with the Operations Manager Details 1.2.3 Showing detailed information on the FibreCAT CX system You query information on a FibreCAT CX system by clicking one of the two storage processors for the FibreCAT CX system you require in the ServerList window. This opens the SV - Storage window, where you can view the Status Overview. I Note that when FibreCAT CX systems are displayed in the ServerView Operations Manager, vendor-independent terminology is used which may not always correspond to the EMC naming conventions: EMC naming conventions Storage Processor Storage Pool Logical Volume ServerView naming conventions RAID Controller RAID Group LUN (Logical Unit Number) FibreCAT CX 15

Status Overview Monitoring with the Operations Manager Status Overview The Status Overview shows the status of the FibreCAT CX system along with the most important model-specific information. 16 FibreCAT CX

Monitoring with the Operations Manager System Information System Information Choose Configuration - System Information to show detailed information on the FibreCAT CX system. FibreCAT CX 17

Port List Monitoring with the Operations Manager Port List (RAID Controller) Choose Raid Controller - <RAID Controller-Name> - Port List to list information on the ports of a RAID controller (storage processor, in this case: SP_A). 18 FibreCAT CX

Monitoring with the Operations Manager Environmental Environmental Choose Enclosures - <physical hard disk> - Environmental to list information on the power supply units of the RAID controllers (storage processors) and the fans of a (physical) hard disk drive. FibreCAT CX 19

Disk Drive (Physical Disk) Monitoring with the Operations Manager Disk Drive (Physical Disk) Choose Enclosures - <physical hard disk> - Physical Disk to list information on a physical hard disk of a FibreCAT CX system. 20 FibreCAT CX

Monitoring with the Operations Manager Virtual Disks Virtual Disks (CLARiiON RAID Groups) Choose Storage Pools - Overview to list information on a virtual hard disk drive (RAID group, logical volume). FibreCAT CX 21

Storage Volumes Monitoring with the Operations Manager Storage Volumes (CLARiiON LUNs) Choose Storage Pools - Storage Volumes to list information on the individual storage LUNs (storage volumes) of the FibreCAT CX system. 22 FibreCAT CX

Monitoring with the Operations Manager Host mapping Host mapping Storage Pools - Host mapping shows how the managed servers are assigned to the storage volumes. FibreCAT CX 23

Index A activities after installation 9 alarm management ServerView 12 C CLARiiON LUNs 22 D detailed information (FibreCAT CX system) 17 Disk Drive (Physical Disk) 20, 21 E EMC SMI-S Provider, see SMI-S Provider Environmental 19 F fans (FibreCAT CX system) 19 FibreCAT CX monitoring preparations 6 software requirements 6 FibreCAT CX system detailed information 17 Disk Drive (Physical Disk) 20, 21 Environmental 19 Host mapping 23 information on fans and power supply 19 information on LUN host mapping 23 information on physical hard disk 20, 21 information on storage volumes 22 integrating in alarm management 12 model-specific information 16 Port List 18 port-specific information 18 server list 13 showing detailed information 15 software requirements 7 Status Overview 16 Storage Volumes 22 System Information 17 H Host mapping 23 I information on host mapping (FibreCAT CX system) 23 information on physical hard disk FibreCAT CX system 20, 21 information on storage volumes FibreCAT CX system 22 install software 8 L Logical Volume 15 LUN (Logical Unit Number) 15 LUN host mapping see host mapping M management server software requirements 6 model-specific information FibreCAT CX system 16 monitoring (FibreCAT CX) preparations 6 P Port List 18 port-specific information FibreCAT CX system 18 power supply FibreCAT CX system 19 FibreCAT CX 25

Index preparations FibreCAT CX monitoring 6 R RAID Controller 15, 18, 19 see also storage processor RAID Group 15 W WWN, see WWPN WWPN 23 S server list FibreCAT CX system 13 ServerView alarm management 12 ServerView Storage Manager (StorMan) 12 SMI-S Provider configuration file 9 connected via Fibre Channel 10 connected via IP connection 11 software installation 8 software requirements FibreCAT CX system 7 management server 6 Status Overview 16 Storage Manager see ServerView Storage Manager (StorMan) storage pool 15 Storage Processor 15 storage processor 15 see also RAID controller Storage Volumes 22 StorMan 12 System Information 17 26 FibreCAT CX