Technical slides SIMATIC S7-1200 Basic Controller in the TIA Portal Frei verwendbar / Siemens AG 2015. Alle Rechte vorbehalten. www.siemens.com/s7-1200
SIMATIC Controller S7-1200 Efficient engineering + Security Integrated. + Diagnostics + Technology Integrated + High performance + Safety Integrated + Innovative design and easy to use + Frei verwendbar / Siemens AG 2015. Alle Rechte vorbehalten. Seite 2
Design and handling S7-1200 CPU Digital inputs Analog inputs Optional memory extension Modular board concept Integrated HSCs & PTOs/PWMs Removable connectors Digital outputs (DC or relay) PROFINET interface (1 or 2 ports) S7-1200: Modular. Powerful Frei verwendbar / Siemens AG 2015. Alle Rechte vorbehalten. Seite 3
Design and handling S7-1200 CPU - setup Current connection Slot for a memory card below the upper cover flap Plug-in terminal block for user wiring (behind the cover flaps) Status LEDs for the integrated I/O PROFINET connection (on the bottom of the CPU) Frei verwendbar / Siemens AG 2015. Alle Rechte vorbehalten. Seite 4
Design and handling Set-up and extension options - maximum CM/CP CPU SM 1 board CPU 1211C CPU 1212C CPU 1214C / 1215C / 1217C S7-1200: variable extension and set-up options for differing requirements Frei verwendbar / Siemens AG 2015. Alle Rechte vorbehalten. Seite 5
Design and handling Extension module assembly Installation Configuration 1. Remove backplane bus cover 1. Loosen the bus connector 2. Insert SM into standard contact by pushing the bolt to mounting rails the right 3. Guide the SM to the adjacent module 4. Lock the standard rail mounting clamp 5. Guide the bracket for the bus connector contact to the left towards the adjacent module 2. Move SM right onto standard mounting rail 3. Unlock standard mounting rail clamp 4. SM out of standard mounting rail Frei verwendbar / Siemens AG 2015. Alle Rechte vorbehalten. Seite 6
Design and handling CPU 17 Versions incl. failsafe CPU 1211C DC/DC/DC DC/DC/RLY AC/DC/RLY CPU 1212C DC/DC/DC DC/DC/RLY AC/DC/RLY CPU 1214C DC/DC/DC DC/DC/RLY AC/DC/RLY CPU 1215C DC/DC/DC DC/DC/RLY AC/DC/RLY CPU 1217C DC/DC/DC S7-1200: variable extension and set-up options for differing requirements Frei verwendbar / Siemens AG 2015. Alle Rechte vorbehalten. Seite 7
Design and handling CPU dimensions CPU 1211C 100 150 CPU 1212C 100 90 CPU 1214C 10 00 110 CPU 1215C 100 130 CPU 1217C DC/DC/DC 100 150 S7-1200: variable extension and set-up options for differing requirements Frei verwendbar / Siemens AG 2015. Alle Rechte vorbehalten. Seite 8
Design and handling Optional CPU functional enhancements using boards Board type SB 1221 SB 1222 SB 1223 SB 1231 AI SB 1231 RTD SB 1231 TC SB 1232 AQ CB 1241 BB 1297 Characteristics 4 DI, DC 5V, HSC with up to 200 khz available for use 4 DI, DC 24V, HSC with up to 200 khz available for use 4 DQ DC 5V, 0.1 A, PWM with up to 200 khz, PTO with up to 100 khz available for use 4 DQ DC 24V, 0.1 A, PWM with up to 200 khz, PTO with up to 100 khz available for use 2 DI, DC 5V, 2 DQ DC 5V, 0.1 A, HSC with up to 200 khz, PWM with up to 200 khz, PTO with up to 100 khz available for use 2 DI, DC 24V, 2 DQ DC 24V, 0.1 A, HSC with up to 200 khz, PWM with up to 200 khz, PTO with up to 100 khz available for use 2 DI, DC 24V, 2 DQ DC 24V, 0.1 A 1 AI, ±10VDC (12 bit) or 0 20 ma 1 AI RTD, PT 100 and PT1000 1 AI thermal elements type J or K 1 AO, ±10VDC (12 bit) or 0 20 ma (11 bit) RS485 communication board Battery board for real-time clock long-term buffering (without CR1025 battery) Frei verwendbar / Siemens AG 2015. Alle Rechte vorbehalten. Seite 9
Design and handling SIMATIC S7-1200 with FW4.1 SIMATIC S7-1200 CPU CPU type 1211C 1212C 1214C 1214FC 1215C 1215FC 1217C PROFINET Ports Work memory / int. load memory 50 KB 1MB 75KB 1MB 100kB 4MB 125kB 4MB 125 kb 4MB 150 kb 4MB 150 kb 4MB Bit performance 85 ns 85 ns 85 ns 85 ns 85 ns 85 ns 85 ns Connection resources 38 38 38 38 38 38 38 Integrated Digital I/O 6/4 8/6 14/10 14/10 14/10 14/10 14/10 Integrated Analog I/O 2/- 2/- 2/- 2/- 2/2 2/2 2/2 High-Speed Counter 6 6 6 6 6 6 6 Frei verwendbar / Siemens AG 2015. Alle Rechte vorbehalten. Seite 10
Design and handling How does the S7-1200 CPU use the SIMATIC memory card? Program card acting as a CPU memory. Loss of all project and program data upon removal of a program card from the CPU. Replacement and extension of the CPU-internal load memory Transfer card For transfer of project and program data into the CPU- internal load memory Removal following data transfer CPU works with the data saved in your memory. For duplication of project and program data in multiple CPUs load Creation of a transfer card or program card with TIA Portal on a PC with an SD card slot Frei verwendbar / Siemens AG 2015. Alle Rechte vorbehalten. Seite 11
Design and handling SIMATIC S7-1200 accessories Accessory part PM1207 Power supply Battery board CSM 1277 Compact Switch Module Details Inputs: 120/230 V AC 50/60 Hz, 1.2 A / 0.7 A Outputs: 24 V DC / 2.5 A for real-time clock long-term buffering (without CR1025 battery) 4 x RJ45 jacks 10/100 MBit/s Digital SIM 1274 input simulator Analog input simulator Extension cable Potentiometer for direct entry of analog value for 2-row station configuration, 2 m Frei verwendbar / Siemens AG 2015. Alle Rechte vorbehalten. Seite 12
SIMATIC S7-1200 Security Integrated - Increased copy protection Linkage of individual blocks to the serial number for the memory card or CPU Protection from unauthorized copying of program blocks with STEP 7 Protection from unauthorized duplication of the configuration on the memory card Protection from unauthorized reproduction of executable programs Frei verwendbar / Siemens AG 2015. Alle Rechte vorbehalten. Seite 13
SIMATIC S7-1200 Security Integrated - Dynamic copy protection with mandatory password As of V4.1 Copy protection with different methods for providing a target serial number: Static linkage: direct configuration of a target serial number (from memory card or CPU) for program blocks Dynamic linkage: automatic detection of a target serial number with linkage to this target serial number during the download on the CPU or memory card Advantages: Both cases involve linkage of the block to a special HW serial number for the CPU or the memory card A block with dynamic linkage in the TIA Portal project is not tied to a certain serial number but is protected via an additional password for copy protection (from STEP 7 V13 SP1) Automatic serial number configuration and simple linkage for machine manufacturers Simple mass download with copy protection for authorized person only Project TIA Portal Program block with static linkage Target serial number: 12345678 Download with check of the serial number by the controller S7 Controller Program blocks with active copy protection 12345678 Program blocks with dynamic linkage Automatic detection Download with automatic integration of the serial number by the TIA Portal Frei verwendbar / Siemens AG 2015. Alle Rechte vorbehalten. Seite 14
SIMATIC S7-1200 Security Integrated - Increased manipulation protection Improved protection from manipulation of the communication with access to the controller by digital checksums Protection from network attacks such as infiltration of fake / recorded network communication (replay attacks) Protected transfer for passwords upon authentication Detection of manipulated firmware updates through digital signatures Protection of communication from unauthorized manipulations for maximum system availability Frei verwendbar / Siemens AG 2015. Alle Rechte vorbehalten. Seite 15
SIMATIC HMI portfolio Efficient to a new level Page 16 V1.0
SIMATIC HMI Basic Panels 2 nd Generation Basic Excellence Top Highlights at a Glance First choice for + simple applications High-resolution + wide-screen display 64.000 colors Innovative graphical + user interface USB interface for auxiliary Equipment and simple Backup/ Restore + Consistent functionality + across all display sizes Page 17 V1.0
SIMATIC HMI Basic Panels 2 nd Generation Beauty is simplicity Innovative Functionality at an Attractive Price Feature / function Efficient engineering with the new WinCC V13 (TIA Portal) Perfect interplay with new SIMATIC controllers, especially S7-1200 High-resolution display: Wide-screen, 64.000 colors, 4-12, innovative graphical user interface Easy logging with USB Benefit Reduction of engineering time: ONE engineering framework for all automation applications Reduction of engineering and system test costs through rapid project engineering Innovative panel technology for easy automation ti solutions Innovative presentation of applications Reduced commissioning expenditures Easy process monitoring Page 18 V1.0
SIMATIC HMI Comfort Panels Page 19 V1.0
SIMATIC HMI Comfort Panels Consistent functionality of all Comfort Panels Archives, scripts, Internet Explorer, PDF/Excel/Word viewer, Media Player, F(x) functions, system diagnostics viewer, All Comfort Panels offer the same high-end functionality over all display sizes. Page 20 V1.0
SIMATIC HMI Comfort Panels Consistent functionality of all Comfort Panels Key devices from 4 up to 15 Operating concept of the keyboard known of mobile phones Green LED at every function key Easier handling of slide-in labels Optimal feedback by embossed function keys Page 21 V1.0
SIMATIC HMI Comfort Panels Integrated functionality of all Comfort Panels Interfaces available for: PROFIBUS / MPI PROFINET / Ethernet USB host (flash drive, mouse, keyboard,...) USB client (transfer) Audio Various communication possibilities by standardized interfaces Page 22 V1.0
SIMATIC HMI Comfort Panels Aluminum front-side casings Robust hardware by a durable aluminum front-side casings starting with the 7-inch model Page 23 V1.0
SIMATIC HMI Comfort Panels Widescreen Display High definition and contrast 16 million colors Viewing angle up to 170 (vertical/horizontal) Brightness up to 400 cd/m² Long lifespan due to LED backlight Widescreen displays for detailed display, high ease of use and best readability www.siemens.com/simatic-hmi-widescreen Page 24 V1.0
SIMATIC Comfort Panels Dimmable LED backlighting LED backlight is dimmable during the running application in the control panel by the screensaver via PROFIenergy Reduced energy costs due to lower current consumption, longer lifespan and additional areas of application (e.g.: in shipbuilding) Page 25 V1.0
SIMATIC HMI Comfort Panels Maximum data security during a power failure Data slot for archives and other data Maximum data security for archives in RDB format in the case of a power loss by using a 2 GB SIMATIC HMI Memory Card. * 1 Energy reserves of the Comfort Panels provide protection against data losses and close RDB archives reliably in the case of a power failure. Inexpensive preservation of all data without using an additional battery. * 1 To secure the preservation of single, not yet archived data by 100% it is recommended to use an interruptible-free power supply. Page 26 V1.0
SIMATIC HMI Comfort Panels Innovative service concept System slot for automatic backup Automatic backup of all process relevant data on a 2 GB SIMATIC HMI Memory Card. The backup is made at the same time with the change of the respective data. No manual actions required. Fast device exchange and commissioning by inserting the card into the target device possible: Insert card confirm message done Automatic backup and fast device exchange by an innovative servicing concept. Page 27 V1.0
SIMATIC HMI Comfort Panels Touch device mounting positions Installation in landscape format or portrait format All Comfort panel touch devices can be operated in portrait or landscape mode, depending on application requirements and available space. Page 28 V1.0
SIMATIC HMI Comfort Panels Printer Expansion of the already supported standard printers PDF print (print as a PDF file) HTML print (print as an HTML file) PostScript print (print via any postscript-compatible printer) Application example: http://support.automation.siemens.com/ww/view/de/58205602 http://support.automation.siemens.com/ww/view/en/58205602 Printer driver: http://support.automation.siemens.com/ww/view/de/11376409 t t ti i /WW/ i /d /11376409 http://support.automation.siemens.com/ww/view/en/11376409 Printout of process data without printer specific printer drivers or into a file format. Page 29 V1.0
SIMATIC HMI Comfort Panels Other highlights Camera Control for the connection of IP cameras Buffered real-time clock with automatic synchronization Transfer via standard cable (Ethernet, USB, etc.) Device configuration (IP, PN, etc.) via engineering OS update via storage medium Innovative features for commissioning, operating and maintenance Page 30 V1.0
Mobile Panels 2nd Generation the next level of mobile HMI devices Unique emergency button + PROFINET / PROFIsafe + Compact connetivity + Performance like a Comfort Panel + Sturdy and brilliant at once + Page 33 V1.0
Mobile Panels 2nd Generation more power, comfort, flexibility and quality! message The second generation of SIMATIC HMI Mobile Panels convinces with its ease-of-use, performance and quality. The highlights are a brilliant widescreen display, exceptionally easy engineering and the unique illuminated emergency stop button. Mobile Panels 2nd Generation - Power and Safety in your hands User-friendly KTP900(F) Mobile Connection box -advanced Wall bracket Comfortable in your hands Bright and brilliant display Style editor proposal Flexibel -standard Non-Safety or Safety version panalysis security elements Connection cable KTP700(F) Mobile Diverse connectivity variants -compact Safe and secure TÜV certificated to SIL3 / PL e 3-step enabling switch Emergency button or stop switch Page 34 V1.0
Mobile Panels 2nd Generation Operational area for mobile HMI Mobile Panels offer a direct access and optimal visual contact to the process! Benefits: Industries: High flexibility Integr. Safety Ergonomically Sturdy warehouse/ Logistics Packaging Machine building Automotive Operating area: Service Setup mode Troubleshooting Secure operating Page 35 V1.0
Mobile Panels 2nd Generation mobiles controlling and monitoring still efficient and secure Feature / Function central engineering-tool TIA Portal (WinCC) with innovative style-editor rugged and brilliant at once: Widescreen, 16 mio. colors, 7 und 9 devices new connection boxes for direct installation at the control cabinet illuminated emergency button evaluation per software (PROFIsafe) or classic via wiring Kundennutzen efficient engineering g for all HMI tasks, even with your own individual design high quality for every industry detailed presentation of complex pictures of process Economically priced connection possibilities for small machines with minor spot offers flexible in use and evaluation of security method Page 36 V1.0
Extreme Operating Page 37 V1.0
New Challenges for HMI Panels Page 38 V1.0